5
Thank You for purchasing a Kenmore water heater. Properly
installed and maintained, it should give you years of trouble
free service. If you should decide that you want the new water
heaterprofessionallyinstalled bySearscall 1-800-4-MY-HOME®.
They will arrange for prompt, quality installation by Sears
authorized contractors.
AbbreviationsFoundIn ThisInstruction Manual:
• CSA - Canadian Standards Association
• ANSI - American National Standards Institute
• NFPA - National Fire Protection Association
• ASME - American Society of Mechanical Engineers
• GAMA - Gas Appliance Manufacturers Association
• This gas-fired water heater is design certified by CSA
INTERNATIONAL under American National Standard/CSA
Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1
(current edition).
• Read the “Safety Precautions” section, page 3 of this manual
first and then the entire manual carefully. If you don’t follow
the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS BODILY INJURY AND/OR
PROPERTYDAMAGE.
This manual contains instructions for the installation,
operation, and maintenance of the gas-fired water heater. It
also contains warnings through out the manual that you must
read and be aware of. All warnings and all instructions are
essential to the proper operation of the water heater and
your safety. Since we cannot put everything on the first few
pages,READ THEENTIREMANUALBEFOREATTEMPTING
TOINSTALLOROPERATETHEWATERHEATER.
• The installation must conform with these instructions and
the local code authority having jurisdiction. In the absence of
local codes, installations shall comply with the following:
In the United States: The National Fuel Gas Code ANSI
Z223.1/NFPA 54. This publication is available from the
Canadian StandardsAssociation, 8501 East Pleasant Valley
Rd, Cleveland Ohio 44131, or The National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269.
• If after reading this manual you have any questions or do not
understand any portion of the instructions, call the Sears
Service Center.
• Carefully plan the place where you are going to put the water
heater. Correct combustion, vent action, and vent pipe
installation are very important in preventing death from
possible carbon monoxide poisoning and fires. See
figure 1.
Examine the location to ensure the water heater complies
with the Facts to Consider About the Location section in this
manual.
• For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation
procedures. Instructions may be obtained from your local
dealer, wholesaler, public utilities or California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.
• Massachusetts Code requires this water heater to be
installed in accordance with Massachusetts 248-CMR 2.00:
State Plumbing Code and 248-CMR 5.00.
• Complies with SCAQMD rule #1121 and districts having
equivalent NOx requirements.
CUSTOMER RESPONSIBILITIES
PRODUCT SPECIFICATIONS
RECOVERYRECOVERY
RECOVERYRECOVERY
RECOVERY MINIMUMMINIMUM
MINIMUMMINIMUM
MINIMUM DIMENSIONSDIMENSIONS
DIMENSIONSDIMENSIONS
DIMENSIONS
TT
TT
TANKANK
ANKANK
ANK TYPETYPE
TYPETYPE
TYPE INPUTINPUT
INPUTINPUT
INPUT RARA
RARA
RATE GTE G
TE GTE G
TE GALAL
ALAL
ALSS
SS
S..
..
.VENT PIPEVENT PIPE
VENT PIPEVENT PIPE
VENT PIPE DIAMETERDIAMETER
DIAMETERDIAMETER
DIAMETER IN INCHES (mm)IN INCHES (mm)
IN INCHES (mm)IN INCHES (mm)
IN INCHES (mm)
MODELMODEL
MODELMODEL
MODEL CAPCAP
CAPCAP
CAPAA
AA
ACITYCITY
CITYCITY
CITY OFOF
OFOF
OF RARA
RARA
RATETE
TETE
TE PER HOURPER HOUR
PER HOURPER HOUR
PER HOUR INCHESINCHES
INCHESINCHES
INCHES INCHESINCHES
INCHESINCHES
INCHES HEIGHT TOHEIGHT TO
HEIGHT TOHEIGHT TO
HEIGHT TO
NUMBERNUMBER
NUMBERNUMBER
NUMBER IN GIN G
IN GIN G
IN GALAL
ALAL
ALS (LS (L
S (LS (L
S (LTRS)TRS)
TRS)TRS)
TRS) GASGAS
GASGAS
GAS (Btu/hr)(Btu/hr)
(Btu/hr)(Btu/hr)
(Btu/hr) @ 90°F RISE@ 90°F RISE
@ 90°F RISE@ 90°F RISE
@ 90°F RISE (mm)(mm)
(mm)(mm)
(mm) (mm)(mm)
(mm)(mm)
(mm) JACKET TOJACKET TO
JACKET TOJACKET TO
JACKET TOP
153.336162 30 (114) NATURAL 32,000 30.6 3" (76) or 4" (102) 181/2" (470) 433/4" (1,111)
153.336262 40 (151) NATURAL 35,500 35.4 3" (76) or 4" (102) 20"(508) 47 1/4"(1,200)
153.336362 30 (114) NATURAL 35,500 34.9 3” (76) 16”(406) 57 1/2”(1,461)
153.336466 40 (151) NATURAL 35,500 35.4 3" (76) 181/2" (470) 551/2" (1,410)
153.336566 50 (189) NATURAL 35,500 35.4 3" (76) 20"(508) 56 1/2”(1,435)
153.336762 30 (114) PROPANE 35,500 34.9 3" (76) 16" (406) 571/2” (1,461)
153.336862 40 (151) PROPANE 35,500 35.4 3" (76) 181/2" (470) 551/2”(1,410)
153.336962 50 (189) PROPANE 35,500 35.4 3" (76) 20"(508) 56 1/2”(1,435)