KDC-1023/1023S/122/122S
ADJUSTMENT
8
1.
IC10 (TDA7513) -The Tuner adjustment method
•When IC10 and its circumference are fixed, according to the
following order, it readjusts if needed.
•The adjustment item changes with parts to exchange. Please
refer to "Parts vs Adjustment item table".
1-1. VCO Coil Adjustment -- Adjustment of Tunning Voltage
Voltage Check Point : Vt-Check Land
(PWB Side_B, around D506)
Adjustment Coil : L507 (VCO Coil)
The adjustment method : VCO coil is turned and adjusted
according to the following tables.
M : AM Adjustment
For Your Information : The frequency of SET is only set up by
Pre-Set-Key in case this adjustment
①The appearance and the coil with which S-METER DC voltage
serves as the maximum are turned and adjusted
in the above-mentioned SG input.
➁By the above-mentioned adjustment method, same adjustment
is performed to both sides (1st&2nd MIX Coil).
TYPE Mode freq. Voltage Fig
E/M AM 1611kHz 5.5 ± 0.1(V) (C)
K AM 1700kHz 5.8 ± 0.1(V) (C)
J FM 90.0MHz 5.6 ± 0.1(V) (C)
W
(Wide Band)
FM 108.0MHz 7.2 ± 0.1(V) (C)
1-2. Adjustment of 1st & 2nd-MIX Coil
Voltage Check Point : S_METER-Check Land
(PWB Side_B, around W572)
Adjustment Coil : 1stIFT = L508 / 2ndIFT = L509
Setting of Signal Generator : Refer to the following tables
TYPE MODE freq. Mod. ANT Input Fig
K AM 1000kHz OFF 35dBuEMF (B),(C)
E,M,J,W AM 999kHz OFF 35dBuEMF (B),(C)
①The appearance and the coil with which S-METER DC voltage
serves as the maximum are turned and adjusted
in the above-mentioned SG input.
➁By the above-mentioned adjustment method, same adjustment
is performed to both sides (ANT&RF Coil).
1-3. Adjustment of FM_ANT&RF Coil
Voltage Check Point : S_METER-Check Land (PWB
Side_B, around W572)
Adjustment Coil : ANT_Coil = L505
RF_Coil = L506
Setting of Signal Generator
: Refer to the following tables.
TYPE MODE freq. Mod. ANT Input Fig
E/M FM 87.5MHz OFF 5 or 11dBuEMF (A),(C)
K FM 87.9MHz OFF 5 or 11dBuEMF (A),(C)
J FM 76.0MHz OFF 5 or 11dBuEMF (A),(C)
W
(Wide Band)
FM 65.0MHz OFF 5 or 11dBuEMF (A),(C)
1-4. Adjustment of STEREO (adjustment of 456k-VCO)
Adjust in TEST_MODE
•How to enter the test mode
While pressing on [ FM ] and [ PRESET 6 ] keys, reset the
unit.
•Adjustment method
Complete on condition that show "ALL OFF" when pressing
on [ PRESET 1 ] and [ PRESET 6 ] keys.
(Writing adjustment valve to the EEPROM.)
Effect of adjustment is in cofirmation of adjustment status at
[ PRESET 4 ] key.
•Display of [ PRESET 4 ]
Adjustment "OK" : 14seg model "E2P OK" 7seg model "EPO"
Adjustment "NG" : 14seg model "E2P ERR" 7seg model "EPE"
•Releasing the test mode
Reset mode only.
ACC off, Power off, Power down and Remove the panel
mode is not releasing.