KeriSystems KDC-8 User manual

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
KDC-8Quick Start Guide
Keri Systems KDC-8 Eight-Door Concentrator places four controllers into one cabinet, reducing
the amount of space needed to mount four controllers. The concentrator is designed to fit in a
standard IT server/telecom rack, but can easily be wall mounted. There are knock-outs around the
outside of concentrator’s enclosure for cable routing.
1.0 Unit Specifications
• Height – 15 inches (plus 0.25 inches for the cover)
• Width – 17 inches (plus 0.25 inches for the cover)
• Depth – 6.5 inches (plus 0.25 inches for the cover)
• Weight – 19 pounds (including controllers and satellite boards, NOT including cabling)
• Power Requirements – 12 VDC @ 3 A for the concentrator cabinet, including four, two-door
controllers.
NOTE: Separately powered door lock power requirements depend upon the door locks being used.
Please ensure sufficient power is provided to support all door locks connected to the cabinet.
Figure 1: 8-Door Concentrator Enclosure
2.0 Mounting the Cabinet
There are three methods of cabinet mounting.
1. wall mounting through the rear of the cabinet
2. wall mounting using the rack brackets
3. rack mounting to a standard IT Server/Telecom rack

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 2 of 24
Quick Start GuideKDC-8
2.1 Through the Cabinet Mounting
The easiest mounting method is wall mounting through mounting holes within the cabinet. There
are three key-hole screw slots and three screw through-holes for secure mounting. Have an assistant
hold the unit in the desired mounting place and mark the mounting locations, see Figure 2 (if there
are controllers in the cabinet, please remove them before mounting the enclosure). Drill pilot holes
in the marked locations and then install the unit.
Note: When fully loaded, the unit weighs 19 pounds (before cabling). Mount the unit securely
against the wall using molly-bolts or by securing at least two mounting screws to a wall stud.
Figure 2: Through-the-Cabinet Mounting Dimensions

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
KDC-8Quick Start Guide
2.2 Bracket Wall Mounting
Attach the brackets to the rear of the cabinet sides (see Figure 3). Have an assistant hold the unit in
the desired mounting place and mark the mounting locations. Drill pilot holes in the marked
locations.
Figure 3: Attaching the Brackets to the Enclosure for Wall Mounting

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 4 of 24
Quick Start GuideKDC-8
Have an assistant hold the unit in the desired mounting place and mark the mounting locations (see
Figure 4). Drill pilot holes in the marked locations and then install the unit.
Note: When fully loaded, the unit weighs 19 pounds (before cabling). Mount the unit securely
against the wall using molly-bolts or by securing at least two mounting screws to a wall stud.
Figure 4: Wall Mounting the Enclosure Using the Brackets

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
KDC-8Quick Start Guide
2.3 Rack Mounting
The cabinet is designed to be installed in a standard IT Server/Telecom rack using the two rack-
mount brackets. Attach the brackets to the sides of the cabinet (see Figure 5).
Figure 5: Attaching the Brackets to the Enclosure for Rack Mounting

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 6 of 24
Quick Start GuideKDC-8
Have an assistant hold the cabinet in the desired mounting place on the rack and secure the cabinet
using the rack mount screws (see Figure 6 and Figure 7 – a generic rack configuration is shown,
your rack may be slightly different).
Figure 6: Attaching the Unit to the Rack - Top View
Figure 7: Attaching the Unit to the Rack - Front View

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
KDC-8Quick Start Guide
3.0 Configuration and Wiring
It takes a lot of cabling to support all eight doors in the cabinet. Knockouts are provided on all four
sides, cabinet providing maximum flexibility for routing cables.
Cabinet configuration is kept simple. The only jumpers of which to be aware are the external door
lock power jumpers, and there are two front-cover LED cables.
3.1 External Door Lock Relays
The 8-door cabinet is designed to allow the door lock relays to operate in two ways.
1. Non-powered/dry-contact for use with devices such as a gate operator or as a non-powered
general purpose output.
2. Powered through the lock relay common for electric door locks. The unit can use one power
supply to drive both the controllers and the lock relays, or have separate power supplies, one for
the controllers and one for the door lock relays.
Each door lock relay can be set according to your application: non-powered/dry-contact or powered
for an electric door lock.
NOTE: When providing power for door lock relays, Keri strongly recommends using two separate
power supplies. This isolates controller power from the transients that can be created on the lock
power line as the door relays kick on and off. This will reduce controller interference.
The factory default is to have the following jumpers set per Table 1, allowing the use of external
lock power through the relay common. Refer to Figure 8 on page 8 for jumper locations.
Jumpers listed in Table 1 must be removed for any controller/satellite board relays used in non-
powered/dry-contact mode or in non-powered, general purpose output mode.
Table 1: External Door Lock Power
Jumpers
Controller A-Door B-Door
Slot 1 J47 J44
Slot 2 J51 J50
Slot 3 J56 J55
Slot 4 J59 J58

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 8 of 24
Quick Start GuideKDC-8
Figure 8: External Door Lock Power Jumpers

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
KDC-8Quick Start Guide
3.2 Cabinet Cover Power LED
The cabinet cover Power LED cable is connected at the factory. It is the left LED on the face of the
cabinet (see Figure 1 on page 1). Should the cable come free, connect the cable to J28 pins 1 and 2
with the RED wire connected to pin 1. Refer to Figure 9.
3.3 Cabinet Cover Data LED
The cabinet cover Data LED cable is connected at the factory. It is the right LED on the face of the
cabinet (see Figure 1 on page 1). Should the cable come free, connect the cable to J60 pins 1 and 2
with the RED wire connected to pin 1. Refer to Figure 9.
Figure 9: Power and Data Cover LED Cabling

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 10 of 24
Quick Start GuideKDC-8
3.4 Individual Controller Wiring Connections
Around the perimeter of the PCB is a ring of 32 connectors. Each connector on the four controllers/
satellite boards has a corresponding connector on the perimeter ring – eight connectors for each
controller/satellite board. Figure 10 shows the location of the connector set for each controller/
satellite board.
Figure 10: Connnector Set per Controller/Satellite Board

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
KDC-8Quick Start Guide
3.4.1 A-Reader, B-Reader (TB5 and TB6)
Controllers will either be Keri Proximity (PXL-500P - see Figure 11) or Wiegand (PXL-500W -
Figure 12). Make the wiring connections from the Reader to the appropriate connector accordingly:
A-Reader to TB5, B-Reader to TB6. Use Figure 10 on page 10 to locate the correct connector
locations for each controller.
Figure 11: Proximity A-Reader and B-Reader Connections (TB5 and TB6)
Figure 12: Wiegand A-Reader and B-Reader Connections (TB5 and TB6)

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 12 of 24
Quick Start GuideKDC-8
3.4.2 A-Door: Lock Relay, Alarm Relay Outputs (TB3)
Make the wiring connections for the A-Door Lock and Alarm Relays (TB3). Use Figure 10 on
page 10 to locate the correct connectors for each controller.
For the Lock Relay, power is applied to the common line. This provides flexibility, allowing you to
provide power to the lock depending upon the type of lock you have.
Figure 13: A-Door Lock Relay and Alarm Relay Connections (TB3)

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
KDC-8Quick Start Guide
3.4.3 B-Door: Lock Relay, Alarm Relay,
General Purpose Outputs 1 and 2 (TB7)
TB7 can serve one of two purposes depending upon the configuration of the controller’s satellite
board: as the B-Door Lock Relay and Alarm Relay OR as general purpose outputs 1 and 2. Make
the wiring connections for either Lock/Alarm Relay usage or for general purpose outputs (TB7).
Use Figure 10 on page 10 to locate the correct connectors for each controller.
For the Lock Relay, power is applied to the common line. This provides flexibility, allowing you to
provide power to the lock depending upon the type of lock you have.
NOTE: If the controller is configured for TB1 general purpose output 1 operation, the
corresponding door lock relay jumper may need to be removed (see Table 1 on page 7 for jumper
identification). Remove the jumper for non-powered/dry-contact operation; leave the jumper in
place for powered operation.
Figure 14: B-Door Lock Relay and Alarm Relay Connections
Figure 15: General Purpose Output 1 and 2 Connections (TB7)

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 14 of 24
Quick Start GuideKDC-8
3.4.4 A and B-Door Held Open Outputs,
General Purpose Outputs 3 and 4 (TB10)
TB10 can serve one of two purposes depending upon the configuration of the controller’s satellite
board: as the A and B Door Held Open Outputs OR as general purpose outputs 3 and 4. Make the
wiring connections for either Door Held Open Relay usage or for general purpose outputs as
required. Use Figure 10 on page 10 to locate the correct connectors for each controller.
Figure 16: A and B Door Held Open Outputs
Figure 17: General Purpose Outputs 3 and 4
NOTE: When wired correctly, all door held open outputs can provide voltage to drive an external
device.

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
KDC-8Quick Start Guide
3.4.5 A-Door: Status Switch, Request to Exit, Auxiliary Request to Exit,
Global Unlock Inputs (TB4)
Make the wiring connections for the A-Door Status Switch and Request to Exit inputs (TB4). Use
Figure 10 on page 10 to locate the correct connectors for each controller.
On the master controller, the final input on TB4 can serve one of two purposes. It can either act as
an Auxiliary Request to Exit for the A-Door or as a Global Unlock for the access control system.
For the master controller, determine if your site requires a Global Unlock input or if you need the
Auxiliary Request to Exit input, and make the appropriate wiring connection.
For all other controllers, the final input can only be used as an Auxiliary Request to Exit for the A-
Door. Make the Auxiliary Request to Exit connection if required.
Figure 18: A-Door: Status Switch, Request to Exit, Auxiliary Request to Exit, Global Unlock
Inputs (TB4)

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 16 of 24
Quick Start GuideKDC-8
3.4.6 B-Door: Status Switch, Request to Exit, Auxiliary Request to Exit,
General Purpose Input 4 (TB8)
Make the wiring connections for the B-Door Status Switch, Request to Exit, and Auxiliary Request
to Exit inputs (TB8). Make the general purpose input 4 connection if required. Use Figure 10 on
page 10 to locate the correct connectors for each controller.
Figure 19: B-Door: Status Switch, Request to Exit, Auxiliary Request to Exit,
General Purpose Input 4 (TB8)

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
KDC-8Quick Start Guide
3.4.7 General Purpose Inputs 5, 6, 7, 8 (TB9)
Make the general purpose input 5, 6, 7, and 8 connections if required (TB9). Use Figure 10 on
page 10 to locate the correct connectors for each controller.
Figure 20: General Purpose Inputs 5, 6, 7, and 8

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 18 of 24
Quick Start GuideKDC-8
3.5 RS-485 Network
J1 and J8 allow you to daisy-chain the RS-485 access control network (see Figure 21). Connect the
incoming RS-485 line to J1 and connect the outgoing RS-485 line to J8 (see Figure 22).
Figure 21: Location of RS-485 Network Connectors
Figure 22: RS-485 In/Out Lines

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
KDC-8Quick Start Guide
3.6 External Door Lock Power
J43 provides the external door lock power (see Figure 23). Connect the line from the power supply
to J43 (see Figure 24). Power can be from an independent power supply or can be daisy-chained
from the controller/cabinet power supply (Section 3.7 on page 20). Power is provided to the relays
through the lock relay common line.
NOTE: When providing power for door lock relays, Keri strongly recommends using two separate
power supplies. This isolates controller power from the transients that can be created as the door
relays kick on and off.
Figure 23: Location of Lock Power Connector
Figure 24: Lock Power Wiring

Eight-Door Concentrator
2305 Bering Drive 01959-001 Rev. 1.1
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: http://www.kerisys.com E-mail: sales@kerisys.com Page 20 of 24
Quick Start GuideKDC-8
3.7 Cabinet Power
J21 provides power to the controllers (see Figure 25). Connect the line from the controller power
supply to J21 (see Figure 26).
Figure 25: Location of Controller Power Connector
Figure 26: Controller Power Wiring
Table of contents
Other KeriSystems Controllers manuals
Popular Controllers manuals by other brands

Extron electronics
Extron electronics MLC 104 IP PLUS quick start guide

Dometic
Dometic RTX1000 Accessory Installation Manual

Emerson
Emerson Fisherr 4660 instruction manual

Jflow controls
Jflow controls JFER Series manual

Computec
Computec CDD6 user manual

Grundfos
Grundfos EPC 300 Installation and operating instructions

iSMA CONTROLLI
iSMA CONTROLLI iSMA-B-MAC36NL user manual

SMC Networks
SMC Networks E-MY2B Series Operation manual

AUTOFLAME
AUTOFLAME Mk8 MM End user guide

American Dynamics
American Dynamics ADTT16E Touch Tracker installation instructions

Honeywell
Honeywell HR 40 Installation and operating instructions

Skov
Skov DOL 534 user manual