Keysight 16060A Operation manual

Keysight 16060A Transformer
Test Fixture
Operation and
Service Manual


Agilent 16060A Transformer T
est Fixture
Operation and Service Manual
Agilent Part No. 16060-90000
Printed in JAPAN March 2000

Notice
The information contained in this document is subject to change without notice
.
This document contains proprietary information which is protected by copyright. All rights are
reserved. No part of this document may be photocopied, reproduced, or translated to another
language without the prior written consent of the Agilent T
echnologies.
Agilent T
echnologies Japan, Ltd.
Component T
est PGU-Kobe
1-3-2, Murotani, Nishi-ku, Kobe-shi,
Hyogo
,651-2241 Japan
W
arranty
This Agilent T
echnologies instrument product is warranted against defects in material and
workmanship for aperiod of one year from the date of shipment, except that in the case of
certain components listed in this manual, the warranty shall be for the specied period. During
the warranty period, Agilent T
echnologies will, at its option, either repair or replace products
which prove to be defective
.
F
or warranty service or repair
,thisproduct must be returned to aservice facility designed by
Agilent T
echnologies
.The Buyer shall prepay shipping charges to Agilent T
echnologies and
Agilent T
echnologies shall pay shipping charges to return the product to the Buyer
.However
,
the Buyer shall pay all shipping charges
,duties
,andtaxes for products returned to Agilent
T
echnologies from another country
.
Agilent T
echnologies warrants that its software and rmware designed by Agilent T
echnologies
for use with an instrument will execute its programming instruction when property installed on
that instrument. Agilent T
echnologies does not warrant that the operation of the instrument,
or software
,orrmware will be uninterrupted or error free
.
Limitation of W
arranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate
maintenance by the Buyer, Buyer-supplied software or interfacing, unauthorized modication
or misuse, operation outside of the environmental specications for the product, or improper
site preparation or maintenance
.
No other warranty is expressed or implied. A
gilent Technologies specically disclaims the
implied warranties of merchantability and tness for a particular purpose
.
Certication
The Agilent T
echnologies certies that this product met its published specications at the
time of shipment from the factory
. Agilent T
echnologies further certies that its calibration
measurements are traceable to the United States National Institute of Standards and
Technology, to the extent allowed by the Institute's calibration facility, or to the calibration
facilities of other International Standards Organization members.

Exclusive Remedies
The remedies provided herein are the buyer's sole and exclusive remedies. Agilent Technologies
shall not be liable for any direct, indirect, special, incidental, or consequential damages,
whether based on contract, tort, or any other legal theory
.
Assistance
Product maintenance agreements and other customer assistance agreements are available for
Agilent Technologies products.
If you need assistance, contact your nearest Agilent T
echnologies Sales and Service Oce
.
A
ddresses are provided at the back of this manual.
c
Copyright 1991, 2000 Agilent Technologies Japan, Ltd.

Manual Printing History
The manual printing date and part number indicate its current edition. The printing date
changes when anew edition is printed. (Minor corrections and updates which are incorporated
at reprint do not cause the date to change.) The manual part number changes when extensive
technical changes are incorporated.
November 1991
:::::: :: :: :::::::::::::::::::
::
::
:::::
First Edition (part number: 16060-90000)
March 2000
:::::: :: :: :::::::::::::::::::
::
:::: :::::
Second Edition (part number: 16060-90000)
iv

Safety Summary
The following general safety precautions must be observed during all phases of operation,
service
,and repair of this instrument. F
ailure to comply with these precautions or with specic
W
ARNINGS
given elsewhere in this manual violates safety standards of design, manufacture,
and intended use of the instrument.
The A
gilent T
echnologies assumes no liability for the customer's failure to comply with these
requirements
.
Do NOT operate in an Explosive Atmosphere
Do
not
operate the instrument in the presence of ammable gasses or fumes
.Operation of any
electrical instrument in such an environment constitutes asafety hazard.
K
eep A
way from Live Circuits
Operating personnel must not remove instrument covers
.Component replacement and
internal adjustments must be made only by qualied maintenance personnel. Do not replace
components with the power cable connected. Under certain conditions
, dangerous voltages
may exist even with the power cable removed. T
oavoid injury
,always disconnect power and
discharge circuits before touching them.
Do NOT Service or A
djust While Alone
Do
not
attempt internal service or adjustment unless another person, capable of turning o
power and capable of rendering rst aid and resuscitation, is present.
Do NOT Substitute P
arts or Modify Instrument
Because of the danger of introducing additional hazards
,do
not
substitute parts or perform
unauthorized modications to the instrument. Return the instrument to aAgilent T
echnologies
Sales and Service Oce for service and repair to ensure the safety features are maintained.
Dangerous Procedure Warnings
W
arnings
,such as the example below
,precede
PO
TENTIALL
YD
ANGEROUS PROCEDURES
throughout this manual. Instructions contained in the
warnings
must be followed.
Warning
Dangerous voltages
,capable of causing death, are present in this
instrument. Use extreme caution when handling, testing, and adjusting
this instrument.
v

Safety Symbols
General denitions of safety symbols used on equipment or in manuals.
Instruction manual symbol: the product will be marked with this symbol when
it is necessary for the user to refer to the instruction manual in order to
protect against damage to the instrument.
Indicates dangerous voltage (terminals fed from the interior by voltage
exceeding 1000 volts must be so marked).
Protective ground terminal. F
or protection against electrical shock in case of
afault in the instrument. Used with wiring terminals to indicate the terminal
which must be connected to ground before operating equipment.
Low-noise or noiseless
,clean ground (earth) terminal. Used for a signal
common, as well as providing protection against electrical shock in case
of afault in the instrument. A terminal marked with this symbol must be
connected to ground in the manner described in the installation (Operation)
manual, and before operating the equipment.
Frame or chassis terminal. Aconnection to the frame (chassis) of the
equipment which normally includes all exposed metal structures
.
Alternating current (power line).
Direct current (power line).
Alternating or direct current (power line).
W
arning
denotes ahazard. It calls attention to aprocedure
,practice
,condition
or the like
,which, if not correctly performed or adhered to
,could result in
injury
or
death
to personnel.
Caution
sign denotes ahazard. It calls attention to aprocedure
,practice
,
condition or the like
,which, if not correctly performed or adhered to
,could
result
damage
to or
destruction
of part or all of the product.
Note
denotes important information. It calls attention to a procedure
, practice
,
condition or the like
,which is essential to highlight.
vi

Contents
1. General Information
Introduction ..................
..
..
..
.........1-1
Using the 16060A ................
..
..
..
........1-1
Product Description ................... ..
..
......1-1
A
ccessories Supplied ..................
..
..
.......1-1
Operating And Safety Precautions .................
..
..
.1-2
Operating ................
..
..
.............1-2
Service ................
..
..
..............1-2
Specications ..................
..
............1-3
Supplemental P
erformance Characteristics ..................1-3
2. Preparation for Use
Introduction ................
..
..
..
...........2-1
Initial Inspection ................... ............2-1
Environment Considerations ................... ......2-3
Operating and Storage ................
..
.........2-3
Connecting The T
est Fixture F
or Use .....................2-3
Repackaging the T
est Fixture .........................2-4
3. Operation
Introduction ..............
...................3-1
OPEN Correction ....... ....................... 3-2
Operation ......
..
......................... .3-3
How to Connect to A
utotransformer . ..
.................3-4
T
oDisconnect the Transformer Being Measured ..
..
...........3-4
How to Use the A:B Switch . ..
..
....................3-5
How to Extend the T
est Leads .... .................... 3-5
Internal Circuit of the 16060A ..................... .. .3-6
4. Service
Introduction ........
............
............. 4-1
Replaceable P
arts .... .. .. .. .................... 4-1
Contents-1

Figures
2-1. Product Overview ..................
..
..
..
.....2-2
2-2. Connecting the T
est Fixture ................. .. .. ...2-3
3-1. T
est Fixture F
eatures ...............
..
..
..
.......3-1
3-2. Making an OPEN ..................... .. ......3-2
3-3. Connecting aTransformer ....................... ..3-3
3-4. Connecting an A
utotransformer ..............
..
..
.....3-4
3-5. Internal Circuit of the 16060A ............... .. ......3-6
T
ables
1-1. Furnished A
ccessories .... ....................... 1-1
2-1. Contents ....
..
......................... ..2-2
3-1. Relationship Between the A:B Switch P
osition and Measurement P
arameters .3-5
4-1. Replaceable P
arts List ....................
.......4-1
Contents-2

1
General Information
Introduction
The purpose of this manual is to enable you to use your 16060A Transformer T
est Fixture
eciently and condently
. This manual contains both general and specic information. T
ouse
the 16060A to perform a specic function (without having to read the entire manual), follow
the directions in \Using the 16060A".
Using the 16060A
T
o install the 16060A,turn to Chapter 2.
T
o operate the 16060A,turnto Chapter 3.
T
oorder replaceable parts for the 16060A,turn to \Replaceable P
arts" in Chapter 4.
Product Description
The 16060A has been designed to operate specically with Option 001 \A
dd N/M/DC-R
Measurement Function" of 4263A LCR Meter
.The 16060A provides aconvenient means of
measuring a transformer's self-inductance
,mutual inductance
,turns ratio
,and dc resistance in
the frequency range of dc to 100 kHz, as appropriate for each measurement.
A
ccessories Supplied
The following accessories are supplied with the 16060A:
Table 1-1. Furnished A
ccessories
Description Part Number Quantity
Operation and Service Manual P/N 16060-90000 1
Test Leads (black) P/N 16060-61601 2
Test Leads (red) P/N 16060-61602 2
General Information 1-1

Operating And Safety Precautions
Operating
Y
ou need observe only normal precautions when handling and operating the 16060A. Do not
exceed the operating input power
,voltage, and current level and signal type appropriate for
the instrument being used, refer to your instrument's operation manual.
Caution
Electrostatic discharge (
esd
)candamage the highly sensitive microcircuits in
your instrument. ESD damage is most likely to occur when the test xture
is being connected or disconnected. Protect the 16060A from ESD damage
by wearing agrounding strap that provides ahigh resistance path to ground.
Alternatively
,ground yourself to discharge any static charge build-up by
touching the outer shell of any grounded instrument chassis before touching
the test port connectors
.
Never touch atest port connector's center contact.
Use awork station equipped with an anti-static work surface
.
Service
The voltage levels in this xture do not warrant more than normal caution for operator safety
.
Nevertheless
,service should be performed only by qualied personnel.
1-2 General Information

Specications
This section lists the complete 16060A specications. These specications are the performance
standards and limits against which the 16060A is tested. When shipped from the factory
,the
16060A meets the following specications:
Measurement P
arameters
:::::::
:::: :::::::::::::::::::::
::
::
:::::::::::::::::
L, N, M, and DCR
Frequency Range
::::::
::
::
::::::::::::::::::::: ::::
::::::::::::::::::::: :: :: :::::
DC to 100 kHz
Applicable Instrument
::::
::
::
::
::::::::::::::::::::: ::::
:::::::::::::::
4263A with Option 001
W
eight
::::::
::
::
::::::::::::::::::::: ::::
::::::::::::::::::::: :: :: :::::::::::::::::::
::
:::: :
300 g
Operating T
emperature
:::
::
::
:::::::::::::::::::::
::
::
::
::::::::::::::::::::: ::::
:::::
0to 55
C
Operating Humidity
:::::: ::::
::::::::::::::::::::: :: :: :::::::::::::::::::
::
::
95% RH (@40
C)
Non-operating T
emperature
::::: :::::::::::::::::::
:::: :: :::::::::::::::::::
::
::
::
:
0
40 to 70
C
Non-operating Humidity
:::: :: :::::::::::::::::::::
::
:::::::::::::::::::::::
::
95% RH (@65
C)
Supplemental P
erformance Characteristics
This section gives supplemental performance characteristics
.Supplemental performance
characteristics are not specications
,but are typical characteristics included as additional
information for the operator. Supplemental performance characteristics are not guaranteed.
Cable Length
:::
:::::::::::::::::::::::::
::::::::::::::::::::::::: ::::::::::::::::::::::: ::
25 cm
Dimensions
::::::::::::::::::::::::::: :: ::::::::::::::::::
90 mm (
w
)
2
35 mm (
h
)
2
90 mm (
d
)
Applicable DUT Size
Diameter of DUT's terminals
:::::::::::::::::::::::::::::::::::::::::::::::::::
::::::::::
4mm
General Information 1-3


2
Preparation for Use
Introduction
This chapter explains how to install the 16060A Transformer T
est Fixture
.The topics covered
include initial inspection, ambient environmental considerations, connecting the test xture for
use
, and repackaging the test xture for shipping.
Initial Inspection
This xture has been carefully inspected electrically and mechanically before being shipped
from the factory
.It should be in perfect physical condition, no scratches
,dents or the like
,and
it should be in perfect electrical condition. V
erify this by carefully performing an incoming
inspection to check the test xture for signs of physical damage and missing contents
.If any
discrepancy is found, notify the carrier and Agilent T
echnologies
.Y
our Agilent T
echnologies
sales oce will arrange for repair and replacement without waiting for the claim to be settled.
1. Inspect the shipping container for damage
,and keep the shipping materials until the
inspection is completed.
2. V
erify that the shipping container contains everything shown in Figure 2-1 and listed in
T
able 2-1.
3. Inspect the exterior of the 16060A for any signs of damage
.
Preparation for Use 2-1

Figure 2-1. Product Overview
T
able 2-1. Contents
Description Agilent P
art Number Quantity
1
Transform T
est Fixture 16060-60001
1
1
2
T
est Lead (black) 16060-61601 2
3
T
est Lead (red) 16060-61602 2
4
Operation and Service Manual
2
16060-90000 1
1
Agilent internal-only part number
.
2
Operation and Service Manual is not shown in Figure 2-1 .
2-2 Preparation for Use

Environment Considerations
Operating and Storage
The 16060A should be operated within an ambient temperature range of 0
Cto 55
Cand
relative humidity up to 95% at 40
C(non-condensing).
The 16060A may be stored within a temperature range of
0
40
Cto +70
,and at arelative
humidity of up to 95% at +65
C(non-condensing).
Connecting The T
est Fixture For Use
Figure 2-2. Connecting the T
est Fixture
Preparation for Use 2-3

Repackaging the Test Fixture
If shipping to aAgilent T
echnologies service center is required, the test xture should be
repackaged using the original factory packaging materials.
Alteratively
,comparable packaging materials may be used. Wrap the test xture in heavy
paper and pack in anti-static plastic packing material. Use sucient shock absorbing material
on all sides of the 16060A to provide a thick, rm cushion and to prevent movement during
shipping. Seal the shipping container securely and mark it
FRA
GILE
.
2-4 Preparation for Use

3
Operation
Introduction
This chapter describes the features of the 16060A (Figure 3-1), and describes how to connect
atransformer to the test xture (Figure 3-3 and Figure 3-4), how to set the A:B switch for
dierent measurements, how to physically extend the measurement distance from the 4263A
using cables and test leads
, and describes the internal circuit of the 16060A.
F
or instructions on how to measure transformer parameters
,see the
4263A Operation Manual
.
Figure 3-1. T
est Fixture F
eatures
1.
Four terminal pair BNC terminals
.
These terminals are connected to the UNKNOWN
terminals of the 4263A .
2.
A:B Switch.
Switch A:B changes the connection between terminal \A" and terminal \B" to
select the transformer parameter to be measured.
3.
COMMON terminals.
These terminals are connected using test leads to the common (low)
terminals of the transformer to be measured as shown in Figure 3-3 and Figure 3-4.
Operation 3-1

4.
Aterminal.
T
erminal A is connected using a test lead to one of the high terminals of the
transformer under test as shown in Figure 3-3 and Figure 3-4.
5.
Bterminal.
T
erminal B is connected using atest lead to the other high terminal of the
transformer under test as shown in Figure 3-3 and Figure 3-4.
OPEN Correction
The 16060A has inherent stray capacitance that adds an error term which decreases
measurement accuracy
.T
ocancel these residual eects and thus minimize measurement error
,
use the measuring instrument's OPEN correction capability
.The procedure is described in
the instrument's operation manual. T
omake an OPEN setup for this procedure
,connect the
center conductors of \A" and \B" together by clipping the respective alligator clips together
,
and separate them from the likewise connected center conductors of the COMMON terminals
.
Figure 3-2 illustrates an OPEN connection setup
.
Figure 3-2. Making an OPEN
Note
The eects of the 4263A SHORT correction depend on the measurement
parameters.F
or more information on the SHORT correction function,
see
the
4263A Operation Manual
.
3-2 Operation
Table of contents
Popular Transformer manuals by other brands

MGE UPS Systems
MGE UPS Systems 12 kVA Installation and user manual

CyberPower
CyberPower OL5KSTF Installation and operation manual

ambiance
ambiance HC-669 Installation and safety instructions

Eaton
Eaton Ulusoy Maintenance, Operation, Installation and Instruction Manual

Yamaha
Yamaha ST15 owner's manual

Arteche
Arteche DDB Series user manual

Bender
Bender WS Series Wiring diagram

Intermatic
Intermatic PX Series Installation, operation & service manual

Pittway
Pittway System Sensor SP100ADA Series Installation and maintenance instructions

Palmer
Palmer PLI-03 quick start guide

Acrel
Acrel AKH-0.66L35D Installation and operation manual

Data Video
Data Video DAC-80 quick start guide