P/N 501-415503-5-20 • REV 2.0 • ISS 08SEP11 1
KFP-CE4 Series Quick Operation Guide
If you hear the buzzer
Determine the cause of the buzzer
If the buzzer is sounding and the Fire Alarm LEDs are
flashing or steady, then it’s a fire alarm.
WARNING: Depending on your fire alarm system
configuration, the buzzer may be your first indication of a
fire alarm.
If the buzzer is sounding and the Fault LED is flashing,
then it’s a fault.
For a fire alarm
1. Determine the location of the fire
Check the location of the fire, indicated by the Zone
LEDs.
If Fire Alarm and Zone LEDs are flashing, the fire alarm
has been activated by a detector. If they are steady, the
fire alarm has been activated by a manual call point.
2. Verify the fire alarm
If necessary, investigate the location of the fire alarm to
confirm that the alarm is genuine.
Depending on the configuration of your fire and
evacuation alarm system, you may have up to ten
minutes to investigate the alarm before fire brigade
notification devices are activated.
3. Leave the building
Once the fire alarm has been confirmed, leave the
building and follow your company’s evacuation drill.
FAULT
FIRE ALARM
2 KFP-CE4 Series Quick Operation Guide
For a fault
WARNING: Never silence the buzzer without first
investigating the cause of the warning signal.
1. Silence the buzzer
To silence the buzzer, press Panel Silence.
The Panel Silence LED turns on and the buzzer stops.
New alarm or fault events will turn the buzzer back on.
2. Contact your maintenance contractor
Contact your maintenance contractor immediately to
investigate and repair the fault.
Activating an evacuation alarm
To activate an evacuation alarm in all evacuation areas,
press the All Sounders Start button and the Confirm
button.
To activate an evacuation alarm in a specific evacuation
area, press the corresponding Evacuation Area button
and the Confirm button.
The Evacuation Area LEDs are steady for evacuation
areas in alarm.
For more information
This document includes basic control panel operation
instructions to be followed in the event of a fire alarm or
fault indication. For detailed operation, refer to the
operation manual.
Maintenance information
Inspect and test the fire and evacuation alarm system in
accordance with all applicable requirements and
regulations.
For service contact
Name:
Address:
Telephone:
Copyright © 2011 UTC Fire & Security. All rights reserved.
ALL SOUNDERS
START
PANEL
SILENCE

Other manuals for KFP-CE4 Series

2

Popular Fire Alarm manuals by other brands

Bosch FPA-1000 Series manual

Bosch

Bosch FPA-1000 Series manual

MEDC SM87BG Technical manual

MEDC

MEDC SM87BG Technical manual

MORLEY-IAS DX CONNEXION product manual

MORLEY-IAS

MORLEY-IAS DX CONNEXION product manual

Fire-Lite Alarms MS-2 instructions

Fire-Lite Alarms

Fire-Lite Alarms MS-2 instructions

Schrack Seconet Integral MAP Quick user manual

Schrack Seconet

Schrack Seconet Integral MAP Quick user manual

Kentec Electronics Sigma A-CP Installation and operation manual

Kentec Electronics

Kentec Electronics Sigma A-CP Installation and operation manual

Teledata SF109 quick start guide

Teledata

Teledata SF109 quick start guide

LST Vds 245402 Specifications

LST

LST Vds 245402 Specifications

Ziton ZP755R-2 Installation sheet

Ziton

Ziton ZP755R-2 Installation sheet

Simplex InfoAlarm 4100U Operator's manual

Simplex

Simplex InfoAlarm 4100U Operator's manual

Ampac FireFinder II Series Installation & operation manual

Ampac

Ampac FireFinder II Series Installation & operation manual

Siemens AnalogPLUS DB1131A installation instructions

Siemens

Siemens AnalogPLUS DB1131A installation instructions

olympia electronics nsc BS-1632 manual

olympia electronics

olympia electronics nsc BS-1632 manual

Autocall Foundation Series installation guide

Autocall

Autocall Foundation Series installation guide

Cooper Notification RSS-24MCC installation instructions

Cooper Notification

Cooper Notification RSS-24MCC installation instructions

Global Fire Equipment ZEOS C manual

Global Fire Equipment

Global Fire Equipment ZEOS C manual

E2S GNExCP6B-PB instruction manual

E2S

E2S GNExCP6B-PB instruction manual

Simplex TrueAlarm 4008-9101 Installation, Programming and Operating Instructions

Simplex

Simplex TrueAlarm 4008-9101 Installation, Programming and Operating Instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.