King Pigeon K6S User manual

The K6s is a new type fashion
designed access control system, it
supports dial to open the door with
free call charge, can remote open
the door for visitors, very suitable
for different office, villas and
public occasion.
User’s Manual
Ver 3.1
Date: 2018-04-10
Download APP
Apartment Intercom

1. Product Features
◆ Support 200 sets of numbers, each number can be set in the time period to control
the relay to open the door.
◆ A relay output is used to control the door open, relay close/open when there is
calling of incoming users, And it will automatically recovery after set time.
◆ After a user calls to control to open the door, it can send SMS to the user about its
action.
◆ 000~999 seconds, we can control the relay activity time, 000 indicates: the relay is
active for 0.5 seconds then recovery. 999 indicate: the relay can be activity until the
same number incomes again then recovery.
◆ SMS commands can be used to query the current state of the host (relay status and
GSM signal value).
◆ SMS can be regularly uploaded for the current state of the host to the first user
number.
◆ Use the clock on the module, each time the host sends SMS to itself to correct the
time.
2. Host Overview
Microphone
Relay, door indicator lamp
(relay close: on; relay open: off)
Signal lamp
GSM version: Slow flash means normal signal. Fast flash means
searching signal. No light means no signal.
3G version: When the signal is normal, the light goes out 1 time per
second. When there is no signal, the light is on 1 time per second.
Dialing key
Press to dial the first 5 user numbers. When it is connected, they can
communicate with each other and press # to open the door
Speaker

3. Internal Wiring Instructions
OUTX (white): The output of the relay is connected with the
electromagnetic switch, used to control the door.
PJ1 (red and black): External power supply, the use of 9~24VDC,
pay attention to distinguish between positive(red) and negative(black).
RST: Reset, jumper wire connection, and then boot, after 10 seconds,
disconnect, Restore factory settings (reset does not clear user’s number
information).
J4 (yellow): Connect to door switch.
4. Setup and Operation
This device is set up and operated by SMS. All of the following letters are uppercase letters.
Password factory default is 1234, "+" is not the message content,Such as equipment time command:
1234TEL13812345678#. Each instruction will receive the corresponding information or action of the
feedback from the device. If you do not receive feedback, indicate that the device did not receive the
instruction, please check whether the card is inserted and the card is valid.
◆ The equipment time calibration
Password + TEL + equipment number#
For the first time or when you want to change your phone card.
◆ Modify the password
Current password + P + new password
◆ Set the user number
Password + A + serial number# + user phone number# or
Password + A + serial number# + user phone number# + start time# + end time#
Serial number : 001~200;

Start time,End time:In this period of time, it can be called in to control the relay, The
Format :1701020304 (indicate: January 2, 2017 3 hours 4 minutes). Do not set the time to indicate
permanent authorization.
◆ Delete user number
Password + A + serial number##
◆ Query user number authorization time
Password + A + serial number#
◆ Query user number
Password + AL + serial number# + serial number#
Example: 1234AL001#009# (query user number of 001~009)
◆ Set allows any number of incoming to control relay
Password + ALL#
◆ Set only user number available of incoming to control relay (default)
Password + AUT#
◆ Set relay activity time
Password + GOT + the activity time#
activity time is 000~999, Unit: second
The activity time is set to 000 (default), which means that the user will automatically recovery when
the relay is activity for about 0.5 seconds;
The activity time is set to 999, which means that the relay is activity until the same number is called
in again.
◆ Set whether or not to return SMS after the relay close(on)
1) Set to return SMS to the first number and the incoming number after the relay close. (Default)
Password + GON11# + Content of SMS#

2) Set to return SMS to the first number, not to the incoming number after the relay close.
Password + GON10# + Content of SMS#
3) Set to return SMS to the incoming number, not to the first number after the relay close.
Password + GON01# + Content of SMS#
4) Set not to return SMS after the relay close.
Password + GON##
◆ Set whether or not to return SMS after the relay open(off)
1) Set to return SMS to the first number and the incoming number after the relay open. (Default)
Password + GOFF11# + Content of SMS#
2) Set to return SMS to the first number, not to the incoming number after the relay open.
Password + GOFF10# + Content of SMS#
3) Set to return SMS to the incoming number, not to the first number after the relay open.
Password + GOFF01# + Content of SMS#
4) Set not to return SMS after the relay open.
Password + GOFF##
◆ SMS control relay close(on)
Password + CC
◆ SMS control relay open(off)
Password + DD
◆ Query device status
Password + EE
◆ Set interval reporting time
Set the fixed interval to report the current state of the device to the first number:
Password + T# + Interval time#
Interval time : 000~999,unit: hour,Default 000, it means not to report.

◆ Query interval reporting time
Password + T#
◆ Query module IMEI code and firmware version number
Password + IMEI#
◆ Set not to dial next authorize umber after someone answering.(Default)
Password +COFF#
Press device button will call first 5 user numbers one by one, if anyone answered, then device will
not call next authorize number, and user can press "#" to open the door when talking.
◆ Set to continue dial next authorize number even someone answering, till press
"*" or "0~9" on the mobile phone.
Password +CON#
After answering, the device will continue to call next authorize number without pressing the key on
the phone. If press "#", then open the door and stop calling next one; Press "*" or "0~9" will not open
the door, and not call next authorize number.
◆ Set calling time
Password + COT + calling time
Calling time: 0~65536, unit: second, default 60, it means the calling will be hung up automatically
once the calling time arrives 60s; 0 means the calling will not be hung up automatically.
◆ Set relay output normal open (Default)
Password +NO
Normally the relay output keep open status, when opening the door, the relay output close.
◆ Set relay output normal close
Password +NC
Normally the relay output keep close status, when opening the door, the relay output open.

5. Schedule: SMS Instruction Set
Function SMS command Remarks
Equipment time calibration Password + TEL +
equipment number#
The first time or replace the phone
card. That needs it.
Modify password
Current password +P
+new password Default password: 1234
Set user number
Password + A + serial
number# + user number#
Serial number is 001~200; permanent
license
Set user number
Password + A + serial
number# +user number#
+ start time# + end time#
Can call into to control relay during
start time and end time.
Delete user number
Password + A + serial
number##
Query user number
authorization time
Password + A + serial
number#
Query user number Password + AL + xxx
+ yyy# xxx, yyy = 001~200, yyy>=xxx
Allow any number to control
relay Password + ALL#
Only user number to control
relay Password + AUT# Default
Set relay activity time
Password + GOT +
Activity time# Activity time: 000~999, unit: second
Return SMS after relay
close(on)
Password + GON + ab#
+ SMS content#
a, b=0 or 1; (a corresponds to the first
number; b corresponds to the number
of incoming calls; 0: not to return, 1: to
return)
Return SMS after relay
open(off)
Password + GOFF + ab#
+ SMS content#
Not to return SMS after relay
close(on) Password + GON##
Not to return SMS after relay
open(off) Password + GOFF##
Control the relay close(on) Password + CC
Control the relay open(off) Password + DD
Query device status
Password + EE
Set interval reporting time
Password + T# + Interval
time# Interval time: 000~999 unit: hour
Query interval reporting time Password + T#
Query IMEI and version Password + IMEI#
Set not call next authorize no.
after answering
Password +COFF#
Default; If someone answer, then not
call next authorize user
Set continue to call next
authorize no. even answering if
without press a key
Password +CON#
Press "#" on the phone to open the door
and stop calling;
Press "*" or "0~9" to stop calling, but
not open the door.
Set calling time Password +COT+ calling
time
Calling time: 0~65536, unit: second,
default 60
Set relay output normal open Password +NO
Set relay output normal close Password +NC
Table of contents
Other King Pigeon Intercom System manuals