King Pigeon S270 User manual

S270/S271
User Manual
Ver 3.4.1
Date Issued: 2020-08-18
King Pigeon Hi-Tech. Co., Ltd.
www.iot-solution.com
4G Cellular
IoT M2M RTU

Page 2 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
Table of contents
1. Brief introduction...................................................................................................................................................6
2.Safety Directions.....................................................................................................................................................7
3. Standard Packing List............................................................................................................................................. 7
4. Mainly Features and Specifications....................................................................................................................... 8
4. 1Mainly Features............................................................................................................................................ 8
4. 2 Specifications............................................................................................................................................... 8
5. Physical Layout and Installation Diagram.............................................................................................................. 9
5.1 Control Unit size............................................................................................................................................9
5.2 LED Indicator Definition.............................................................................................................................. 10
5.3 Interface Definition..................................................................................................................................... 11
6. Settings & Operation............................................................................................................................................14
6.1 Start to Configure........................................................................................................................................15
6.2 Setting Self-checking...................................................................................................................................17
6.3 Configurator software interface and running.............................................................................................. 18
Basic Settings.....................................................................................................................................19
Number Settings................................................................................................................................20
Output Settings................................................................................................................................. 21
Incoming Control Settings..................................................................................................................23
DIN Trigger Settings........................................................................................................................... 23
DIN/AIN Alarm Settings..................................................................................................................... 25
AIN Trigger Settings........................................................................................................................... 25
Timer Settings....................................................................................................................................27
Logic Trigger Settings......................................................................................................................... 28
Network Settings............................................................................................................................... 28
Historical Record................................................................................................................................30
7. Example Of Applications...................................................................................................................................... 31
7.1 Device working self-checking...................................................................................................................... 31
7.2 Device connect analog transducer.............................................................................................................. 33
7.3 Cloud configuration, wechat notify application...........................................................................................37
8. Device SMS Command and SMS APP...................................................................................................................38
9. Device GPRS/3G/4G Communication Protocol.................................................................................................... 42
9.1 Device Networks Topology.......................................................................................................................... 42
9.2 Communication Networks...........................................................................................................................42
S270/S271 RTU I/O Register List and Function Code..........................................................................43

Page 3 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
9.3 Message communication sequence............................................................................................................ 45
9.4 King Pigeon IoT RTU Protocol/ Definition Protocol......................................................................................45
9.5 Modbus TCP Protocol..................................................................................................................................46
9.6 Modbus RTU Over TCP................................................................................................................................ 46
9.7 Modbus RTU over TCP Communication Application....................................................................................47
10. MQTT................................................................................................................................................................. 50
11. Upgrade Firmware............................................................................................................................................. 53
12. Cellular Module Upgrade.................................................................................................................................... 53
13. Warranty............................................................................................................................................................ 53
[Warm Tips---Read Before Use]
With the rapid development of industrial Internet of things, it has been
widely used in various fields, but it involves a wide range of knowledge from sensor, intelligent instrument, gateway,
4G wireless communication, to cloud server, large screen display, app, etc
The professional knowledge of users has higher requirements, so please electronic engineers to install and
set.We suggest you be careful reading this article will help you quickly and successfully complete the product setup
and implementation of your application.
1. Working Principle
Taking a few minutes to understand the working principle of this product will help users quickly understand the
working principle of the device and clarify their ideas,and realize the function of these applications.
1) Device Working Principle
This device collects front-end sensor and meter data, and after logical processing and calculation, it is sent to the
mobile phone number set by the user via SMS or sent to the designated cloud server via the data network. The
cloud server identifies the device according to the unique number of the device The relationship between the
device and the user, while pushing cloud data to the APP or WeChat official account bound to the user.
This handbook has been designed as a guide to the installation and operation of S270~S271 GSM/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
Statements contained in the handbook are general guidelines only and in no way are designed to supersede the
instructions contained with other products.
We recommend that the advice of a registered electrician be sought before any Installation work commences.
King Pigeon Hi-Tech.Co., Ltd, its employees and distributors, accept no liability for any loss or damage including
consequential damage due to reliance on any material contained in this handbook.
King Pigeon Hi-Tech.Co., Ltd, its employees and distributors, accept no liability for GSM Network upgrading or SIMCard
upgrading due to the technology specifications contained in this handbook.

Page 4 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
2) Functional components of the overview
According to the type of transmitter and sensor supported by the equipment, select the appropriate
model, .Please refer to 1.6 technical parameter description to confirm whether the selected sensor is suitable and
wiring.
RTU device:
It is used to read the sensor data, and then perform the logical processing of the data. The processed data is
transmitted to the cloud platform server via SMS or 4G wireless network. At the same time, the RTU device also
accepts the instructions of the cloud platform server and performs logical processing,drive IO device.
Cloud server
To access the cloud platform, you need to set the server target address on the RTU device side, and then the RTU
device takes the initiative to initiate a connection, the cloud platform must also set the RTU device parameters to
receive the data sent by the RTU device.
After receiving the data, the cloud platform server processes the data according to the rules, stores it in the
database, and pushes it to the computer user or App users
Mobile phone/computer:
First, register an account in the cloud platform and bind the corresponding RTU device. After receiving the data
uploaded from the RTU device, the cloud platform can push it to the corresponding mobile phone app and
computer users after processing.Similarly, mobile app or the instructions sent by the computer will also be sent to
the cloud platform first, and then the cloud platform will be pushed to the RTU device.
2. Device setting step
This product involves front-end sensors, logic processing of equipment itself, cloud platform data management,
app and other parts,Therefore, understanding the setting sequence and steps of this product will help users quickly
and orderly set device parameters and access to cloud platform to realize various application functions of users
Step1: Hardware settings [set locally]
Set parameters according to the manual, IO input and output wiring specifications, logic judgment and control,
RS485 serial port expansion and application, equipment and configuration software and cloud platform server
communication parameter settings, etc.

Page 5 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
Step2: Cloud settings
Only by setting the relevant parameters of the device on the cloud platform can the relationship between the
device and the user be read, and the large screen display can be set content, cloud platform voice alarm,
equipment and video monitoring Association, cloud platform SMS alarm, cloud platform mailbox alarm, and
User management rights and other functions.
Step3: APP download and wechat settings(if need)
Step4: Test and complete the setup.
If you have any questions or settings fail, please read "S27x 4G RTU FAQ" or find the corresponding model in the
help center of http://www.iot-solution.com to find solutions.
【UPGRADE HISTORY】
DATE CONFIGURATOR
VERSION
FIRMWARE
VERSION Author DESCRIPTION
2018.12.21 V3.0 V3.0 KG
1.Modbus address and function code revised;
2.AIN/DIN alarm content setting revised;
3. Interlock event added.
2019.09.24 V3.01 V3.2 ZYH 1. Cellular default settings
2. Delete SDK function
2020.7.24 V3.2 V3.3 CJ
1. Add DIN1-3 low speed pulse counter
2. Add MQTT
3. Add "warm tips"
4. Add notes to user FAQs
5. Modify the configuration software
picture and Di, AI description
6.Fix some errors
2020.8.03 V3.4 V3.4 ZLF 1. Add IO internal schematic block diagram and wiring
2. Modify mqtt parameter settings
2020.8.18 V3.4.1 V3.4.1 CJ 1.Modify the preparation step error before
configuration
Model List
Model DIN AIN Relay TH SD Card Extend I/O tags/Mapping registers Port

Page 6 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
Boolean 16-Bit 32-Bit 64-Bit
S270 2 2 2 1 × × × × USB
S271 4 4 4 1 × × × ×
S272 8 6 4 1 8G 64 64 × × USB/RS485
S275 8 6 4 1 8G 64 128 64 64
Notice 1. Default version is GSM/GPRS module inside.
2. For 3G WCDMA, 4G LTE version, please tell our sales where would you like to use them.
1. Brief introduction
The Cellular IoT M2M RTU is an industrial class, high reliability, high stability, and programmable Remote Terminal
Unit (RTU). It embedded 32-Bit High Performance Microprocessor MCU, inbuilt industrial Cellular module. It
provides 4/2 digital inputs, 4/2 analog or PT100 Resistance Temperature Detector (RTD) inputs, 4/2 relay outputs, 1
ambient sensor input for monitoring onsite temperature and humidity. It can monitoring and operates the I/O

Page 7 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
ports by SMS, APP, Web Server, internet, timers and programmed inter-lock events automatically.
The Cellular IoT M2M RTU inbuilt TCP/IP protocol stack make it suitable for internet of things (IoT) applications, it
can be easily to operate by the provided cloud, app, and web server, or integrated to you IoT applications according
to the TCP/UDP protocol, or integrated to SCADA systems by standard Modbus TCP protocol, too. This is very useful
if you need remote control onsite devices with low cost solution.
The Cellular IoT M2M RTU is design for working in the harsh industrial application environment, widely used in a
variety of industrial automation, security monitoring system, automatically measurement and control system, BTS
monitoring, remote data acquisition, telemetrically systems, automatically control system. It can be used as a
remote switch, remote I/O, remote smart PLC, timer switches.
The Cellular IoT M2M RTU can be used as remote access control for BTS monitoring, the authorized users can open
the gate or turn on the machine with a free charge call at specified time, this is useful for daily maintenance to save
the time of traditional authorized.
Typically applications:
BTS Monitoring, Security Alarm System applications, Supervision and monitoring alarm systems, Automatic
monitoring system, Vending Machines security protection, Pumping Stations, Tanks, Oil or Water levels, Buildings
and Real Estate, Weather Stations, River Monitoring and Flood Control, Oil and gas pipelines, Corrosion protection,
Temperatures, water leakage applications, Wellheads, boat, vehicle, Energy saving, street lights control system,
Valve controls, Transformer stations, Unmanned machine rooms, Control room application, Automation System,
M2M, Access Control System, etc.
2.Safety Directions
Safe Startup
Do not use the unit when using GSM/3G/4G equipment is prohibited or might bring disturbance or
danger.
Interference
All wireless equipment might interfere network signals of the unit and influence its performance.
3. Standard Packing List
RTU X1; AC/DC Adaptor X1; GSM/3G/4G Antenna X1;User Manual X1; PC Configurator X1 .
Note: The package does not include any SIM card.
Optional: 35mm Standard DIN rail fixed Bracket

Page 8 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
4. Mainly Features and Specifications
4. 1Mainly Features
GSM/GPRS/3G/4G network communication, can be operated from anywhere, no distance limitation;
Wide range power supply 9~36VDC with over voltage and phase-reversal protection;
Embedded ARM Cortex -M4 32 Bit RISC Core, 168 MHz inside, RTOS system, reliable performance
with in-built watchdog;
2/4 digital inputs, compatibles dry and wet contact. Logic level: 0~0. 5V or short circuit treated as close,
+3~30V or open circuits treated as open. DI0-3 can be used as counter, sampling frequency is 1Mhz, DI1 can
be used as Arm/Disarm;
2/4 relay output (5A/30VDC,5A/250VAC), can auto control by timer, alarm-link and remote control by SMS,
cloud. The first DO can set time to control by authorize number;
1 temperature & humidity sensor input for monitoring onsite environment, the sensor model is AM2301,
Measures temperatures from -40-80°C,0.5°C accuracy, Relative Humidity from 0-99RH%, accuracy is 3%;
2/4 analog inputs, 12bits resolution, supports 0-5V, 0-20mA, 4-20mA output transducers;
Powerful SMS function: threshold high SMS alert, SMS set, SMS inquiry;
Inbuilt 1 DC output for external transducers to save wiring cost;
Automatically resend the data while communication interrupt or failure, and failure will alert by SMS text to
users;
Supports remotely restart the RTU, and configure& operate it by SMS commands remotely;
10 SMS Alert and auto dial numbers for receiving alarm message, can program to receive specified alarm
message. The authorized numbers also can dial to open the door or turn on/off machine with a free charge
call at the specified time;
Inbuilt inter-lock logic programmer and powerful timer program function;
Modular structure design, replace a module can upgrade the network from 2G to 3G/4G or 3G to 4G;
Support SMS, dial, GPRS, 3G , 4G network for alert, USB port for configuration and upgrade firmware;
Inbuilt large capacity rechargeable backup battery, alert when external power failure,standby time is 5 hours;
Support TCP/UDP,MQTT, Modbus TCP, Modbus RTU over TCP, King Pigeon IoT RTU protocol and data
transparent transmission function;
Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for
industrial applications in the field;
L140 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.
4. 2 Specifications
Item Reference Scope
DC
Power
supply
Standard
adapter:
DC
12V/2A
Range
9-36VDC

Page 9 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
Power
consumption
Standby:12V/50mA;
Working
Max.:
12V/150mA
GSM
Frequency
850/900/1800/1900Mhz
3G/4G Optional: WCDMA/TDD-LTE/FDD-LTE
TCP/IP
stack
TCP,UDP
SIM interface Supporting 3V and 1.8V SIM Card
External
antenna
SMA
Antenna
interface,
50
Ohm,
Gain:
3dB
Serial Interfaces 1 USB Port
Protocols SMS, GPRS UDP,TCP, MQTT,Modbus RTU over TCP and King Pigeon RTU
protocol.
Digital Inputs
2/4 Digital input, NC/NO type, All can be used as Pulse Counters; DI0 as
a high-speed pulse counter, sampling frequency: 1MHz;
DI1~3 as a low-speed pulse counter, the anti-shake time can be set to
1~2000ms, the default is 1ms;
DI1 as arm and disarm function;
Isolation protection:2KVrms
Analog Inputs 2/4 Analog Inputs. 12 bit resolution, 0-5V or 0-20mA or 4-20mA;
Input resistance:>1M ohms
Temp.&Hum Inputs Temperature range: -40°C to +80°C, Humidity Range: 0~100%RH;
Relay Outputs 2/4, Rated: 5A/30VDC,5A/250VAC
Isolation
protection:2KVrms
Power Outputs 1 Port, for external device;
Backup
Battery
3.7V
900mAH
Temperature range -20-+70 °C
Humidity
range
Relative
humidity
95%
(condensation
free)
Exterior dimension 140mm*88mm*30mm
Net Weight 350g
5. Physical Layout and Installation Diagram&Wiring
5.1 Control Unit size

Page 10 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
5.2 LED Indicator Definition
LED Indicator Definition
Power RTU status indicator, LED ON when switched RTU on..
Cellular network indicator. When 2G register network, off 2 seconds, on 0.5s and
so on; When 3G 4G register network, on 2s, off 0.5s...Flicks quickly means data

Page 11 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
transmission.
Alarm Alarm Indicator, alarm will ON and flick. Normally is OFF;
Arm Arm/Disarmed Indicator, Arm is ON, disarmed is OFF.
Run RTU running status indicator, ON or OFF stands for RTU halted, flicks slowly stands for
RTU running.
5.3 Interface Definition
Backside Switch & Button Definition
SIM Card Slot For SIM Card Installation, only supports 1.8V/3V SIM Card
Power Switch For switch ON or OFF the RTU
Upgrade
Firmware Switch
For upgrade firmware purpose only. Only when upgrade new firmware version will use it,
otherwise keep it at Work Side all the time.
Power Connector Definition
DC IN+ External DC Power input port, Connect to 1.5A@9~36V DC power, positive electrode.
DC IN- External DC Power Input port, contact to negative electrode
DC Out+
Power source output port, positive electrode. Provides power from RTU to external
transducers or sensors or detectors. The output current should less than the power from
DC IN inputs. If adapter current is 2A, then suggest external transducer current to be less
than 1.5A
DC Out - Power source output port, Negative electrode.
DIP Switch Definition
SET/RUN
For setting the RTU Mode is in Configuration Mode or Run mode.
Switch it to upside is Set Mode, under this mode, the user can use PC Configurator via
USB cable to configure the RTU Parameters or Read Parameter settings.
Switch it to Downside is Run Mode, under this mode, the RTU is in Running mode.
Tips:
When device mode changed, need to switch off/on the device.
0/V/mA
The 1st channel of analog input type switch. If not use this channel then no matter is
upside or downside.
Switch it to upside stands for the 1st analog input should connect to 0~5V voltage output

Page 12 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
transducer.
Switch it to Downside stands for the 1st analog input should connect to 0~20mA or
4~20mA current output transducer.
Tips: The wrong side will cause device can't read the analog value.
1/V/mA~3/V/mA
The 2nd to 4th channel of analog input type switch. If not use this channel then no matter
is upside or downside.
Switch it to upside stands for the related analog input should connect to 0~5V voltage
output transducer.
Switch it to Downside stands for the related analog input should connect to 0~20mA or
4~20mA current output transducer.
Analog Input Definition
Analog inputs, Sampling frequency 200mS, 12bits resolution, supports 0-5V, 0-20mA, 4-20mA output
transducers, please refer to above mentioned DIP Switch Definition to connect the correct transducers.
0+/0- The 1st Channel Analog input. + stands for positive electrode, - stands for negative
electrode.
1+/1- ~3+/3- The 2nd ~4th Channel Analog input. + stands for positive electrode, - stands for negative
electrode.
Digital Input Definition
Dry contact or wet contact, sampling frequency 200mS . Logic level: 0~0. 5V or short circuit treated as close,
+3~30V or open circuits treated as open. One of the input can be used as counter, sampling frequency is
1Mhz,the second input can be used for Arm/Disarm.
0The 1st digital input, positive electrode.
1~3 The 2nd~4th digital input, positive electrode.
GND GND for digital inputs, negative electrode.
ATN Port Connector Definition
ATN GSM/3G/4G Antenna connector, 50Ohm, SMA male.
USB Port Connector Definition
USB USB port, for configuration and upgrading firmware and exporting historical data;
Temperature Humidity Sensor Port Definitions
T/H Temperature & Humidity sensor AM230x input. Measurement Range: Temperature:
-40°C to +80°C, Humidity: 0~100%RH.
Digital Solid Relay Output Connector Definition
Solid Relay inside for outputs, Rated Capacity: 5A/30VDC,5A/250VAC.
0+/0- The 1st Channel Solid Relay Output. + stands for positive electrode, - stands for negative
electrode.
1+/1- ~ 3+/3- The 2nd ~ 4th Channel Solid Relay Output. + stands for positive electrode, - stands for
negative electrode.

Page 13 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
S27X wiring diagram
AI internal interface principle block diagram
DI internal interface Principle block diagram :
DO internal interface Principle block diagram :
S27X Wiring:

Page 14 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
6. Settings & Operation
The GSM SMS GPRS 3G 4G Cellular IoT M2M RTU is user-friendly design. The user can setup it or export historic
data by the PC Configuration through USB cable, and upgrade firmware by USB port. The GSM SMS GPRS 3G 4G
Cellular IoT M2M RTU also can be configured some basically parameters by SMS Commands, please refer to SMS

Page 15 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
Command App or SMS Command List.
Tips!
When using an IoT card, it does not support sending and receiving SMS and voice dialing alarm functions, so there is no need to set the
content related to SMS; at the same time, when the device need access to the cloud platform server, please disable the SMS alarm and
dialing function, otherwise the device will frequent offline due to sending and receiving SMS and dialing
Below is the steps to setup the parameters by PC Configuration, please follow it step by step.
6.1 Start to Configure
Step1: Install the Configurator
Download from www.iot-solution.com or scan the QR code card in the package, then installs it on the
computer.
Step2: Connection
Please insert the SIM Card, and install the GSM/3G/4G Antenna.
Step3: Switch the DIP Switch to Setup Mode. (Before Power On the RTU)
Switch it to upside is Set Mode, under this mode, the user can use PC Configurator via USB cable to
configure the RTU Parameters or Read Parameter settings.
Notice:
Please switch it to Downside after you finished the configurations. Otherwise, the RTU cannot work properly. The Downside is
Run Mode, under this mode; the RTU is in Running mode.
Step4: Connect the Gateway to the PC by USB Cable. And connect the external DC Power to DC Power Ports,
Power on, and switch on the device, see below:
Step5: Install USB Drvier
Install the USB Driver to the computer from www.iot-solution.com. When successful, it can be found out at
the device manager of the XP or Windows 7 or Win8/Win10, please see the below photo. Also, the driver for
different OS can be downloaded from Silicon Laboratories, Inc. http://www.silabs.com , the model is
CP210x.

Page 16 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
Step6: Run the Configurator (Compatible with Windows XP/7/8/10)
Tips: In some computer, it required download net framework 4.0 while installation, then please click “Yes” to go to
Microsoft website to download this service pack.
Please click to run it. Enter the password, default is 1234. Then you can enter the configuration
page as below:
Notice:
If display the below windows, then means the RTU connect to the PC failure. The reasons are below:
1) USB Driver installation failure;
2) USB Cable connection is disconnected;
3) The DIP Switch in RUN mode, not in SET mode;
4) The Upgrade Firmware Switch at Load side, not at Work side.

Page 17 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
5) Power Switch switched off or DC Power Connection is disconnected.
Step7: Choose the correct "COM port" in device manager above, enter the password(default is 1234),click the
"OK" to connect and start to program
Details please check the picture as below:
Tips: If not connect successfully, will not enter into next step. Pls check if USB connect well, or COM port and
password correct or not.
Then select what SIM card do you use.
6.2 Setting Self-checking
Phenomenon Possible Reason
Can't enter software
1. USB Driver installation failure;
2. COM Port not correct or USB driver installation failure;
3. Device not enter into setting mode:
1) Only power light on, that means the Upgrade Firmware Switch at Load side,
not at Work side. Solution: Switch the power switch to OFF---->
Upgrade switch to Work side----> Power switch to ON.
2) Signal light flicks, that means device in working mode. Maybe had not
rebooted the device after switch mode switch to Set.
(In setting mode, Power light normal ON, Run light flicks, other lights Off.)
After switching panel on,
only Power light on, panel
can't work
1. The Upgrade Firmware Switch at Load side, not at Work side.
Solution: Switch the power switch to OFF---->Upgrade switch to Work side---->
Power switch to ON;
2. SD card fall out from the slot. Solution: Shake panel to listen if there is voice or

Page 18 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
not;
3. In upgrade mode, use upgrade tool erased the firmware.
Can't enter into working
mode
1. The Upgrade Firmware Switch at Load side, not at Work side.
Solution: Switch the power switch to OFF---->Upgrade switch to Work side---->
Power switch to ON;
2. Device in setting mode. Solution: Switch device OFF---->Mode switch to
"Run"---->Switch the device on.
Can't find COM Port
1. Have not installed driver;
2. PC system problem cause driver installation failure, can't support Apple OS
system.
3.Check USB line, and try other common driver software such as "Drive TheLife".
In working mode, the
device not response the
Modbus command
Have not set the device ID. Solution: In setting mode, set device ID---->Switch the
device to Run mode.
After switching panel on,
not running according to
parameter setting
After parameter setting,forget to click "Save" button in every page.
Solution: Back to Set mode---->Click "Save" Button after setting one
page---->After all page set successfully, click "Save Setting" in the menu.
Terms usually used by Cellular IoT M2M RTU
Cellular IoT RTU, Modbus RTU, Modbus Slave, Modbus RTU Over TCP, Modbus TCP, Arm, Disarm...
6.3 Configurator software interface and running
Save : Click it to save all of the PC Configurator parameters to the RTU;
Load Configuration file: Click it to load additional configuration file to the Configurator;
Export Configuration file: Click it to save the present configuration parameters as a profile for next RTU

Page 19 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
configurating or backup the parameter settings.
Tips: The load and export configuration file is very useful while you need to program bulks of RTU with similar parameters.
After programmed the first unit then you can export profile to save it, for the second RTU then you can load profile directly to save
you time.
Factory Reset: Click it to recovery the parameters to factory defaults.
Notice:
1. After setting or revising parameter, need to click the "Save" button of this page, then click "Save Settings" in menu for
saving parameters in device
2. Before S270/S271 export configuration, need to read Slaves configuration details first, to avoid Slaves information missing.
3.Easy way to revise parameter: Open parameter setting page---->Click "Read" button to get device current value
---->Revise and click "Save" button---->Click the "Save Settings" button in the menu.
4. Switch the device mode to "Run" as below, otherwise it will not work;
5. Reboot the device, switch the Power Switch to OFF, then switch it to ON, the device will enter into normal
running mode after that
Basic Settings
Reminder:
1.Please click the "Read" for previous parameter before starting to set.
2.When accessing the cloud platform, the [Automatic report item] and [Alarm SMS setting] items may not be set.

Page 20 of 57 King Pigeon Hi-Tech. Co., Ltd. Ver 3.0
GSM
/SMS/GPRS/3G/4G
Cellular IoT M2M RTU
Modify Password: This is for modifying the RTU’s Password, default is 1234.
Synchronous device time: This is to setup the RTU’s time for daily report or other timers. After click Write
the RTU Time, the RTU will be synchronous the same time as the PC. If connect to King Pigeon Cloud
Server, no need this step.
Device ID: Non-necessary. This is mainly for monitoring center to identify the RTU;
If communicate via Modbus protocol, device ID only can be 1~247.
Device description: This is the description of the RTU, e.g.: installation address,
usage instructions and so on.
Add Timestamp to Alarm SMS: Tick it stands for while alarm occurrence, the Alarm SMS
will include the RTU’S current time information at the SMS Content.
Arm automatically when Power On: Tick it stands for once the RTU powered up, the RTU
will enter into Arm Mode automatically.
Auto Arm after Disarmed: Fill the timeout to enter into Armed Mode automatically after
disarmed operation. This is useful for security protection applications.
Tips:
Arm: Under this mode, any alarm occurrence will send SMS and dial the authorized numbers immediately. And execute the
programmed I/O outputs.
Disarmed: Under this mode, alarm occurrence will not send SMS & dial the authorized numbers.
Timer Reporting SMS Content Settings: Tick the related items to add its value/status to the
Timer report SMS contents.
Alarm SMS Content Settings: Ticks the related items to add its value/status to the Alarm
SMS Contents.
Number Settings(If access the cloud platform, no need to set)
This is to setup the Authorized User Telephone Numbers to receive the Alarm SMS or dial. Tick it stands for
while the related event alarm occurrence will send SMS to this number.
Other manuals for S270
1
This manual suits for next models
1
Table of contents
Other King Pigeon Intercom System manuals