Kobold TEA-R User manual

Operating Instructions
for
Room and Surface Thermostats
Model: TEA-R

TEA-R
page 2 TEA-R K06/0223
1. Contents
1.Contents ........................................................................................................ 2
2.Note .............................................................................................................. 3
3.Instrument Inspection .................................................................................... 3
4.Regulation Use ............................................................................................. 3
5.Operating Principle ........................................................................................ 4
5.1TEA-R .................................................................................................. 4
6.Mechanical Connection ................................................................................. 4
7.Electrical Connection .................................................................................... 5
7.1General ................................................................................................ 5
8.Technical Information .................................................................................... 6
9.Order Codes ................................................................................................. 6
10.Dimensions ................................................................................................... 6
11.Disposal ........................................................................................................ 7
12.EU Declaration of Conformance ................................................................... 8
Manufactured and sold by:
Kobold Messring GmbH
Nordring 22-24
D-65719 Hofheim
Tel.: +49(0)6192-2990
Fax: +49(0)6192-23398
E-Mail: [email protected]
Internet: www.kobold.com

TEA-R
TEA-R K06/0223 page 3
2. Note
Please read these operating instructions before unpacking and putting the unit
into operation. Follow the instructions precisely as described herein.
The instruction manuals on our website www.kobold.com are always for currently
manufactured version of our products. Due to technical changes, the instruction
manuals available online may not always correspond to the product version you
have purchased. If you need an instruction manual that corresponds to the
purchased product version, you can request it from us free of charge by email
([email protected]) in PDF format, specifying the relevant invoice number and
serial number. If you wish, the operating instructions can also be sent to you by
post in paper form against an applicable postage fee.
Operating instructions, data sheet, approvals and further information via the QR
code on the device or via www.kobold.com
The devices are only to be used, maintained and serviced by persons familiar
with these operating instructions and in accordance with local regulations
applying to Health & Safety and prevention of accidents.
When used in machines, the measuring unit should be used only when the
machines fulfil the EC-machine guidelines.
3. Instrument Inspection
All Instruments are inspected before shipping and sent out in perfect condition.
Should damage to a device be visible, we recommend a thorough inspection of
the delivery packaging. In case of damage, please inform your parcel service /
forwarding agent immediately, since they are responsible for damages during
transit.
Scope of delivery:
The standard delivery includes:
Room and Surface Thermostats model: TEA-R
4. Regulation Use
Any use of the Room and Surface Thermostats, model: TEA-R, which exceeds
the manufacturer’s specifications, may invalidate its warranty. Therefore, any
resulting damage is not the responsibility of the manufacturer. The user assumes
all risk for such usage.

TEA-R
page 4 TEA-R K06/0223
5. Operating Principle
5.1 TEA-R
The room thermostats are fitted with liquid-filled helix probes made out of copper
or stainless steel that act as temperature dependant pressure sensors. A change
in temperature causes a pressure change in the probe, which is transferred to a
switch by a bellow system or a diaphragm. A compression spring acts as a
counteracting force. The switching values are set by changing the initial stress of
the compression spring with a setpoint spindle.
Function
Heating
The adjusted rated value (scale value) is equal to the turn-off-value of the
heating. The turn-on-value is lower by the amount of the switching difference.
When a temperature rises on the adjusted value the contact 2-3 (or red-blue)
opens.
Cooling
The adjusted rated value (scale value) is equal to the turn-on-value of the cooling.
The turn-off-value is lower by the amount of the switching difference. When
temperature rises on the adjusted value the contact 1-2 (or red-white) closes.
6. Mechanical Connection
Remove all packing materials and transport retainers and ensure that no such
materials remain in the device.
Make sure that the maximum temperature of the device is not exceeded. (see
section Fehler! Verweisquelle konnte nicht gefunden werden. Fehler!
Verweisquelle konnte nicht gefunden werden.)
TEA-R
The room thermostats TEA-R is fastened by the housing holes to the lower
surface to an even surface.

TEA-R
TEA-R K06/0223 page 5
7. Electrical Connection
7.1 General
Warning! Make sure that the voltage values of your system
correspond with the voltage values of the measuring unit.
Attention! Make sure that the supply wires are de-energized.
TEA-R1
TEA-R3

TEA-R
page 6 TEA-R K06/0223
TEA-R2
8. Technical Information
Operating instructions, data sheet, approvals and further information via the QR
code on the device or via www.kobold.com
9. Order Codes
Operating instructions, data sheet, approvals and further information via the QR
code on the device or via www.kobold.com
10. Dimensions
Operating instructions, data sheet, approvals and further information via the QR
code on the device or via www.kobold.com

TEA-R
TEA-R K06/0223 page 7
11. Disposal
Note!
Avoid environmental damage caused by media-contaminated parts
Dispose of the device and packaging in an environmentally friendly
manner
Comply with applicable national and international disposal regulations and
environmental regulations.
Batteries
Batteries containing pollutants are marked with a sign consisting of a crossed-out
garbage can and the chemical symbol (Cd, Hg, Li or Pb) of the heavy metal that
is decisive for the classification as containing pollutants:
Cd1 Hg2 Pb3 Li4
1. „Cd" stands for cadmium
2. „Hg" stands for mercury
3. „Pb" stands for lead
4. „Li" stands for lithium
Electrical and electronic equipment

TEA-R
page 8 TEA-R K06/0223
12. EU Declaration of Conformance
We, KOBOLD Messring GmbH, Hofheim-Ts, Germany, declare under our sole
responsibility that the product:
Thermostat Model: TEA – R
to which this declaration relates is in conformity with the standards noted below:
EN 60730-1:2011 Automatic electrical controls for household and similar use -
Part 1: General requirements
EN 50581:2012 Technical documentation for the assessment of electrical
and electronic products with respect to the restriction of hazardous substances
Also, the following EU guidelines are fulfilled:
2014/30/EU EMC Directive
2014/35/EU Low Voltage Directive
2011/65/EU RoHS
Hofheim, 24 March 2020
H. Peters M. Wenzel
General Manager Proxy Holder
Table of contents
Other Kobold Thermostat manuals
Popular Thermostat manuals by other brands

MOB
MOB IT3575 user manual

nVent RAYCHEM
nVent RAYCHEM HWAT-T55 Operation manual

Unical
Unical KTsmart Instruction on Installation and Use

Olympia
Olympia HT 430-23A instruction manual

Dwyer Instruments
Dwyer Instruments TS2 Series Installation and operating instructions

Honeywell
Honeywell CT62A installation instructions