PAGE 2 MP-5312 I ChAmplifier Monitor Panel
AMPLIFIER MONITOR
AMPLIFIER OUTPUT LEVEL METER ( dB )
AMPLIFIER OUTPUT SIGNAL
8 97 11 12
4
32
1
OFF MAX
MONITOR VOLUME
7
56
3
4
8
AMPLIFIER SELECT
111
12
9
10
2
10654321
-13 -8 -3 0 3
Parts Identification
12
3
4
5
67
1. SPEAKER
Audio monitoring of selected amplifier output is monitored from this 1 watt speaker
2. MONITOR VOLUME KNOB
3. AMPLIFIER SELECT
The loudness of speaker volume is controlled from this 5 steps attenuator.
This knob is used to select the amplifier intended to be monitored.
4. LED BAR METER
The output level of the amplifier selected is monitored from the 5 segment LED bar meter. The meter indicates the
actual output level of amplifier regardless of the position of the monitor volume. The reference of the reading shall
be 0dB equivalent to 100V line output.
5. AMPLIFIER OUTPUT SIGNAL LED
6. DC SUPLLY CONNECTOR
These LED shall provide signal presence of all the amplifiers connected to the monitoring panel.
MP5312 shall require 24V DC supply for its operation. Kindly use recommended power supply (Kodio PS5424).
7. AMPLIFIER INPUT CONNECTOR
Polarity of amplifiers to be connected to MP5312 shall be observed as wrong connection shall cause your power
pack faulty.
MP-5312