19 • 3/16 KPRO Manual 20
PASO 10 PROCEDIMIENTO PARA CAMBIO DE FILTRO
STEP 10 FILTER CHANGING PROCEDURES
A. Sediment and Carbon: Turn Filter Pac/
R/O module ball valve to off position. Turn
tank ball valve off. Turn on R/O faucet
to help de-pressurize system. Unscrew
filter bowls by turning counter-clockwise.
Remove old filters and discard. Clean filter
bowls if needed in warm, soapy water. In-
sert new filters into appropriate filter bowls.
Make sure O-ring at top of filter bowl is
clean, lubricated and seated properly when
tightening. If changing the post filter, do so
now following the same procedure as the
pre-filters. Follow Step 7: System Start-Up
Procedures. Check for leaks and adjust as
necessary.
B. R/O Membrane: Turn R/O tank and water
supply off. Turn on R/O faucet to help de-
pressurize system. Disconnect white tube
going into membrane housing. Unscrew
end cap of membrane housing. Have a
towel and a bucket handy because some
water will pour out. Pull out old membrane
and clean membrane housing if necessary
with warm, soapy water. Insert new mem-
brane in the same direction as old mem-
brane. Push firmly up to properly seat R/O
membrane. Replace end cap and reconnect
white tube to membrane housing. Fol-
low Step 7: System Start-Up Procedures.
System should be sanitized each time
the membrane is changed. (See Recom-
mended Sanitizing Procedures). Test TDS
(Total Dissolved Solids) rejection rates and
be sure the rates are over 75%. A TDS
monitor is optional on some models and
included on others. If your unit did not come
with a monitor, you can order one or seek
advice from a local water treatment service
company. A new membrane should perform
between 90-98% TDS removal. Check for
leaks and adjust as necessary.
*Indicador de funcionamiento. Los sistemas de O/I contienen un tratamiento del componente
reemplazable que es esencial para la reducción efectiva de TDS (Total de Sólidos Disueltos). El
agua producida debe examinarse periódicamente para vericar que el sistema esté funcionando
apropiadamente. Para examinar el agua, puede llamar a la compañía que le instaló el sistema de
O/I o a un distribuidor autorizado. Si ninguna compañía está disponible en su área, puede enviar
una muestra de agua a AmeriFlow™, donde en forma gratuita realizarán una prueba de TDS del
agua de su sistema de O/I. Adicionalmente, puede comprarle al fabricante un monitor de la calidad
del agua, que le permitirá comprobar el agua producida en su propia casa.
Para enviar muestras de agua para pruebas de TDS al fabricante, haga lo siguiente. Utilice dos
depósitos limpios, vierta aproximadamente ½ taza de agua del grifo en un depósito y en el otro
depósito vierta ½ taza de agua producida por O/I.
Para ordenar ltros de reemplazo o localizar un distribuidor en su área, llame a la fábrica:
AmeriFlow™ Water Systems Inc. (602) 275-4188.
A. Sedimento y Carbono: Gire la válvula bola
a la posición de cerrado del módulo de
Filtro Pac/R/O. Cierre la válvula bola del
depósito. Abra el grifo de O/I para ayudar a
disminuir la presión del sistema. Desator-
nille la cubeta de filtro girando contrarreloj.
Remueva filtros viejos y deséchelos. Limpie
la cubeta de filtro, si fuese necesario,
con agua caliente y jabón. Inserte filtros
nuevos en la cubeta de filtros apropiada.
Asegúrese de que la junta O-ring de la
cubeta de filtro esté limpia, lubricada y
asentada apropiadamente cuando ajuste.
Si cambia el filtro fijo, hágalo siguiendo
el procedimiento de los pre-filtros. Siga
el Paso 7: Procedimientos de Inicio del
Sistema. Revise que no haya pérdidas y
ajuste como sea necesario.
B. Membrana O/I: Cierre el paso al depósito y
el suministro de agua de O/I. Encienda el
grifo para ayudar a disminuir la presión del
sistema. Desconecte el tubo blanco que
se dirige a la carcasa de la membrana.
Desatornille la tapa de la carcasa de la
membrana. Tenga una toalla y una cubeta
a mano porque seguramente se derramará
algo de agua. Saque la membrana vieja y
limpie la carcasa de la membrana con agua
caliente y jabón, si fuera necesario. Inserte
la nueva membrana en la misma dirección
de la membrana vieja. Empuje firmemente
hacia arriba para asentar apropiadamente
la membrana de O/I. Remplace la tapa y
R/O MODEL
MODELO O/I
KR10
KR15
6mo. (mes)- 1yr. (año)
PRE SEDIMENT
PRE SEDIMENTO
P1 #136 -1110 -1
N/A
1 yr. • 1 año
PRE CARBON
PRE CARBONO
CB05 #135-1210-1
CB05 #135-1210-1
2-5 yrs. • 2-5 años
MEMBRANE
MEMBRANA
TFC-24 #138-124-1
TFC-24 #138-124-1
1 yr. • 1 año
M.A.P.™ CARBON
CARBONO M.A.P.™
N/A
CB-A #135-1210-2
1 yr. • 1 año
POST CARBON
CARBONO FIJO
CB #135-1210-2
CB #135-1210-2
* Performance indicator. The R/O system contains a replaceable treatment component criti-
cal for effective reduction of TDS (Total Dissolved Solids). The product water shall be tested
periodically to verify that the system is performing properly. Testing can be accomplished by
contacting the service company that installed your R/O system or an authorized dealer. If a
service company is not available in your area a water sample may be sent to AmeriFlow™ for
a free TDS test of your R/O water. Additionally a water quality monitor is available for purchase
from the manufacturer that will allow the product water to be tested at home.
To send water samples for TDS testing to the manufacturer do the following. Using 2 clean
containers put approximately ½ cup of tap water in one container and ½ cup of R/O product
water in the other container. Send both samples to the manufacturer along with your contact
information.
To order replacement filters or locate a source in your area call the factory: AmeriFlow™ Water
Systems Inc. (602) 275-4188.
below 75%. The rejection rate should be
tested periodically to insure optimal perfor-
mance. The membrane typically lasts 2-5
years depending on influent water quality
and hardness. See performance indicator
information listed below. *
D. Carbon Post-filter/Carbon M.A.P.™
Filter: These filters need to be changed at
least every 12 months to insure quality wa-
ter. Do not wait until taste is a problem.
LISTA DE REEMPLAZOS DE FILTRO •numero de partes •frecuencia de reempl azo
FILTER REPLACEMENT LIST •part numbers •replacement frequency
A. Pre-ltro de sedimento: Estos ltros son
los únicos que pueden inspeccionarse
visualmente. Cuando nuevos son blancos y
necesitará cambiar el ltro cuando su color
cambie a un tono oscuro con la suciedad y el
sedimento. Un suavizante de agua prolon-
gará la vida de los ltros. Contrólelos cada 6
meses, o con una frecuencia mayor si funcio-
nan en malas condiciones de agua.
B. Pre-ltro de carbono: Estos ltros deben
ser cambiados una vez al año. El cambio
de ltros es necesario para asegurar la vida
de la membrana y la calidad del agua. Se
recomienda utilizar ltros para carbono
con capacidad de bloqueo alto. No se re-
comienda utilizar ltros de carbono granular
porque al inicio desprenden carbono no de
manera excesiva, lo cual puede reducir la
vida del elemento de la membrana.
C. Membrana de O/I: La membrana de O/I es
un componente reemplazable que es esen-
cial para la reproducción efectiva de TSD
(Total de Sólidos Disueltos). La membrana de
O/I debe ser cambiada cuando la razón de
rechazo de TSD es menor al 75%. La razón
de rechazo debe ser medida periódicamente
para asegurar un funcionamiento óptimo.
Típicamente la membrana dura de 2 a 5 años
dependiendo de la crudeza y la calidad del
agua. Consulte la información del indicador
de funcionamiento en la parte inferior. *
D. Filtro Fijo de carbono/Filtro M.A.P.™ de
carbono: Estos ltros deben ser cambiados
al menos cada 12 meses para asegurar la
calidad del agua. No espere hasta que el
sabor sea el problema.