KS T40S-C Manual

A.FU E CARRIER Pull out to replace
fuse (a special 2A B 646 20mm x
5mm, this is not an ordinary fuse)
B.LCD DI PLAY
C. to G. BUTTON TO ET DAY, TIME,
PROGRAMME AND RANDOM
H.PU H ON/OFF WITCH Allows
unit to operate as ordinary light switch
activates even when lid is shut.
L.OVERRIDE WITCH
MAN = MANUAL MODE
AUTO = AUTOMATIC PROGRAMME
MODE
J. RE ET BUTTON
K.RED NEON FUNCTION
Before attempting any installation work
turn off the electrical supply at the mains
switch, fuse box or consumer unit and
for additional safety remove the fuse.
King hield security wall light switches
cannot be used with other electronic
products.
1.After installation, the internal back up
battery will need to be fully charged to
enable correct operation.
2.After the main supply is switched back
on, wait 5minutes and operate the
reset button and allow the internal
battery to charge for 45-60 minutes.
After this period follow the operating
instructions as normal.
3.DO NOT use in two-way systems with
dimmers or any other switch
containing electronic circuitry.
(common) terminal. Incorrect wiring
will often result in a blown fuse.
hould the switch remain in-operative
after correcting the error, replace the
fuse with the spare provided.
4.If the light operates correctly from one
switch in a two way circuit then the
wiring is incorrect. Re-check to find
error. Check that the wire connected to
the L2terminal of the two way switch
has been removed and reconnected to
the C (common) terminal.
5.If the digital display goes blank when
the other switch in a two way circuit
is operated, please refer to no. 4
above.
IF A PROBLEM ARISES SOME IME
AF ER INS ALLA ION
If loss of time and programmes set
occurs after the replacement of either a
blown fuse, blown bulb or power failure -
Press the RE ET button and reset the
correct time and day and re-programme
the required on and off times.
Every effort has been made to ensure
that the guidance information on this
sheet will enable the installation of the
security light switch to be carried out
safely and correctly.
ALWAYS REPLACE WITH A SPECIAL
2AMP BS646 FUSE. (THIS IS NOT AN
ORDINARY 2AMP FUSE)
PLEASE KEEP THESE
INSTRUCTIONS SAFE FOR FUTURE
REFERENCE
4. uitable for tungsten filament bulbs
40W to 400W maximum and most low
energy (CFL) 17W and above. Not
suitable for low voltage lighting or LED
lighting.
5.Not suitable in 3-way circuits.
NOTE
If using a metal backbox this should be
earthed.
YELLOW & GREEN EARTH MU T REMAIN
CONNECTED TO METAL BACK BOX
Before installing your ecurity Wall Light
witch in a two way circuit, it is first
necessary to determine which method of
wiring has been used in your home.
The primary reason for doing this is to
make sure that the switch is wired in
such a way that has a permanent live
feed at all times in order to power the
electronic timer.
1.TURN OFF THE MAIN UPPLY
2.Loosen the two switch plates from
the wall.
3.Do NOT disconnect any wires at this
stage.
4. tudy the existing wiring arrangement;
compare to the ‘before’ illustrations.
-If you find 3wires at each switch
(excluding the earth wire) see Diagram
3. If you find 5wires at one switch and
5wires at the other (excluding the
earth wire) see Diagram 5. After
establishing the appropriate wiring
method, install the security light switch
as per the corresponding ‘after’
illustration.
INSTALLATION/OPERATING
INSTRUCTIONS FOR
ELECTRONIC WALL SWITCH
TIMER - T40S-C
WIRING INSTRUCTIONS
WIRING INSTALLATION IN ONE
WAY SWITCHED CIRCUIT
WIRING INSTALLATION IN TWO
WAY SWITCHED CIRCUIT
Di gr m 1- Before
Issue no: 702641
Di gr m 2- After
The position of the override switch L
does not affect the operation.With cover
plate up, the red neon K is still visible,
enabling you to check at a glance
whether the light switch is in AUTO
(programme mode), in which case the
Neon K will come ON if programme is
on and OFF if programme is off, or in
MANUAL mode then it will flash.
To access the controls again, grip the
cover plate with forefinger and thumb
either side and ease cover forward.
In the event of a light bulb “blowing” the
light switch will fail to operate. Always
disconnect power before replacing the
bulb by pulling the fuse carrier ’A’ until
the fuse is fully visible. It may be
necessary to replace the fuse if the
switch does not operate when the carrier
is pushed back into position following
bulb replacement. There is a slot in the
base of the carrier which allows the old
fuse to be pushed upwards and removed.
In order to ensure that the set
programmes do not overlap, it is
advisable to plan beforehand, using the
table below.
e.g. First programme will be set to come
on at 8.10pm until 11.06pm everyday.
1.If the digital display remains blank,
press the RE ET button. Also, check
that the light bulb has not blown.
2.If the light switch will not switch on
or off in a one way circuit, check that
the screws which fix the security light
switch to the wall box have not been
over tightened.
3.If the light will not switch on or off
from either switch in a two way circuit -
(If the above does not solve this
problem) the wiring may be incorrect,
and requires re-checking. Check that
the wire connected to the L2terminal
of the two way switch has been
removed and reconnected to the C
CHANGING A LIGHT BULB
PROGRAMME PLANNER
ON
TIME
OFF
TIME
MO
TU
WE
TH FR A U
e.g PROG 1
20.10
23.06
X
X
X
X X X X
PROG No 2
PROG No 3
PROG No 4
PROG No 5
PROG No 6
TROUBLESHOOTING
PROBLEMS & SOLUTIONS
A
B
C
D
E
H
L
J
G
F
K
IMPORTANT
This unit should be installed to current
IEE wiring regulations if in doubt consult
a qualified electrician.
Rated Voltage: 230V, AC 50Hz
Load: Max 400W–Min 40W + most
Low Energy (CFL) 17W &
above, not suitable for LED
lighting
Integral 2amp fuse
TECHNICAL DATA
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
sales@gre enbro ok.co .uk
W W W. G R E E N B R O O K . C O . U K
T40S Instructions July 2011:T40S FINAL WORKING INSTRUC copy 3/8/11 13:12 Pag 1

To access controls, with thumb and
forefinger on either side, ease cover
forward. With tip of ballpoint pen, press
reset button J to clear memory. Press and
hold down TIME button C continuously.
Press DAY button D until present-day is
displayed.Press HR and MIN buttons E
and F until correct time is set using a
24-hour clock.Release TIME button C.
E.g. L.C.D.display
B showing current
time is 3.15pm on
Wednesday.
NOTE
Continued pressure on any of the
DAY,HR,MIN buttons whilst TIME button
is depressed will advance the display
rapidly.
There are a maximum of 6 ON and 6
OFF times available. Each ON/OFF time
can be used individually on any day(s)
throughout the week, OR can be set to
repeat on one of the following
combination of days: to run a
programme, override switch L must be in
the auto position.
MO TU WE TH FR A U (days of the week);
MO TU WE TH FR (weekdays);
A U (weekends)
MO TU WE TH FR A (workdays only);
If you wish to switch light automatically
every day of the week at 20:10 (8:10pm)
and OFF at 23:06 (11:06pm).
STEP 1
Press the PROG button G and release.
The colon in the
centre will flash
The first time can be entered:
STEP 2
Press DAY button D until required day or
combination of days is displayed. In the
above case, press until ALL THE DAY
appear on the top.
STEP 3
Press HR button E until 20 shows:
STEP 4
Press MIN button F until 10 minutes
are set:
STEP 5
Press PROG button G so that the
first OFF time can be entered:
STEP 6
Press HR button E until 23 shows:
STEP 7
Press MIN button F until 06 minutes
are set:
STEP 8
Up to 6 ON and 6 OFF programmes are
available and it is not necessary to use
them all. Press TIME button C to revert
back to clock.
If you wish to have a second programme
which switches your light on at 18:00
hours (6.00pm) and off at 22.30 hours
(10.30pm) every saturday and sunday
only.
STEP 1
Press PROG button G and previous ON
setting will appear. Keep pressing PROG
G until you have stepped through all the
previous ON/OFF settings and until you
come to the first display, which has 4
dashes:
STEP 2
Press DAY button D until only A
and U appear:
STEP 3&4
Press HR and MIN buttons E and F to
set required ON time (zeros must be
entered):
STEP 5
Press PROG button G to set OFF time:
STEP 6
Press DAY button D until both A and
U appear as above:
STEP 7
Press HR and MIN buttons E and F to
set required off time:
STEP 8
Press TIME C to revert back to CLOCK.
IMPORTANT NOTE:
Ensure the day(s) selected in the
programme ON mode matches day(s)
selected into the programme OFF mode.
Once programming is completed, the
lamp can be switched on and off at
varying times on a daily basis if
RANDOM FUNCTION is selected.
imply press DAY D and HR E buttons
simultaneously. The word TIMER will
flash to show RANDOM mode is
activated. To cancel RANDOM, press
DAY D and HR E simultaneously again
and the word TIMER will disappear.
NOTE: The random feature works by
randomly shifting the ON/OFF times of
your set programmes between 2and 30
minutes at each operation.
Press PROG G and on each occasion all
previously set ON and OFF times will be
displayed. Any alterations can be made
by pressing button D, E and F as
appropriate. Blank ON/OFF times will
have 4dashes instead of numbers. New
programmes can be entered by following
steps 1to 8in example 1.
During those occasions when you are at
home early and you do not want your
security light switch to operate as
programmed, slide switch L so that MAN
shows for manual only operation. The
pre-set programmes are still stored. The
switch can operate only via push switch
H. The red neon K will flash.To recall
automatic programme (i.e. to activate
switch to pre-set programmes) slide
OVERRIDE switch L so that AUTO
shows. Neon light K will come ON if
programme is on and OFF if programme
is off.
When all settings have been completed,
close the front cover plate until it clicks
into position, concealing the operating
controls. The room light(s) can be turned
ON and OFF by simply pressing the top
front cover once, or by operating the
switch at the other end of a 2-way circuit.
PROGRAMMING LIGHT SWITCH
SETTING A PROGRAMME
REVIEWING SET
PROGRAMMES
MANUAL ON/OFF OPERATION
RANDOM FUNCTION
AUTOMATIC OR MANUAL
CONTROL - OVERRIDE SWITCH
EXAMPLE 1
TIMER _ _ : _ _
ON
A U
TIMER _ _ : _ _
ON
A U
TIMER 18 : 00
ON
A U
TIMER 22:30
OFF
MO TU WE TH FR A U
TIMER 20 :__
ON
MO TU WE TH FR A U
TIMER 20 : 10
ON
MO TU WE TH FR A U
TIMER - - : - -
OFF
MO TU WE TH FR A U
TIMER 23 : 06
OFF
WE
15.15
MO TU WE TH FR A U
TIMER _ _ : _ _
ON
EXAMPLE 2
WIRING INSTALLATION FOR
5&3WIRE ARRANGEMENT
3Wires in both switches
Timer installed at live
wire end only
Di gr m 3- Before
Di gr m 5- Before
Di gr m 4- After
Di gr m 6- After
Di gr m 7- After
YELLOW & GREEN EARTHS MUST REMAIN
CONNECTED TO METAL BOX
5&3wire arrangement
Yellow & Green earths must
remain connected to
metal box
Light switch timer at 3wire end
Yellow & Green earths must
remain connected to
metal box
C
Light switch timer at 5wire end
Yellow & Green earths must
remain connected to
metal box
1. Ensure light fitting(s) being controlled
have bulb(s) fitted, otherwise light switch
will not function.
2. After installation is complete, reconnect
power at the mains (remembering to
replace fuse if removed for safety
reasons). The red neon K and the L.C.D.
display B will now be flashing. (Allow
internal battery to charge for 45 minutes).
SETTING PRESENT
DAY & TIME
MO TU WE TH FR A U
TIMER 23 : - -
OFF
T40S Instructions July 2011:T40S FINAL WORKING INSTRUC copy 3/8/11 13:12 Pag 2