pass & seymour rt12 User manual

Setting the initial time Delay
1. Press the Menu/Raise button ONCE to see the current Delay setting.
The factory setting for the Delay is 5 minutes, the minimum setting.
2. To change the setting, press the
Select/Save (middle) button.
3. Press the Menu/Raise button. The time
increases 5 minutes each time you press
the Raise button, until the time reaches
1 hour (100 ). After 1 hour, the time
increases 15 minutes each time you press
the button, until it reaches 12 hours
(1200), then it goes back to 5 minutes
(5:00). You can go backwards at any point
to reduce the time, using the ower
button.
4. When the desired time shows in the
display, press the Select/Save button to
save the setting and exit the programming
mode.
Setting the Sound
1. Press the Menu/Raise button TWICE to see the current Sound setting.
2. To change the setting, press the Select/Save (middle) button.
3. Press the Menu/Raise button to turn ON the warning and keypress sounds.
Press the ower button to turn OFF the warning and keypress sounds.
4. When the desired setting shows in the display, press the Select/Save button
to save the setting and exit the programming mode.
Setting the Flash
1. Press the Menu/Raise button THREE times to see the current Flash
setting. If a fan is connected to the switch, Flash should be Off.
2. To change the setting, press the Select/Save (middle) button.
3. Press the Menu/Raise button to turn ON the warning flash. Press the
ower button to turn OFF the warning flash.
4. When the desired setting shows in the display, press the Select/Save button
to save the setting and exit the programming mode.
5:00
10:00
15:00
... to
55:00
100
115
130
145
200
215
... to
1200
}
minutes
in 5-minute
increments
hours &
minutes
in 15-minute
increments
}
TR UBLESH TING
To test the time switch:
The pilot light behind the ON/OFF button should be ON when the switch is OFF
and OFF should appear in the display. Press the ON/OFF button. The connected
light or fan comes ON. The display shows the amount of time that the switch will
remain ON.
The connected light or fan should turn OFF in the number of minutes indicated
by the display. You can turn it OFF sooner by pressing the ON/OFF button again.
Light or fan will not turn N (pilot light is visible):
Press ON/OFF button. The connected light or fan should turn ON. If not:
• Press and hold the button a second longer.
• Check the light bulb and/or motor switch on the fan mechanism.
• Turn OFF power to the circuit then check wire connections.
Light or fan will not turn N (no pilot light or display is visible):
• Shade the switch from external light to make sure that the pilot light and
display are not ON.
• Make certain that the circuit breaker is ON and functioning.
• Turn OFF power to the circuit then check wire connections.
• Call 800.223.4185 for technical support.
Light or fan will not turn FF:
• Press the ON/OFF button. If the connected light or fan does not turn OFF,
press the button and hold it a second longer.
• Turn OFF power to the circuit then check wire connections.
www.passandseymour.com
RT12
Time Switch
Programmable Countdown
Installation Instructions
SPECIFICATI NS
Voltage..................................120VAC,60Hz
oad
Single Pole Circuit . . . . . . . . . . . . . . . . . . . . . . .0–600 Watt
Incandescent or fluorescent lamp or 1/6HP fan motor
Time Delay . . . . . . . . . . . . . . . . . . . . . . .5 minutes to 12 hours
Environment
Operating Temperature . . . . . . . .32° to 104°F (0° to 40°C)
Humidity . . . . . . . . . . . . . . . . . . . .95% RH, non-condensing
Tools Needed:
Insulated Screwdriver
Wire Strippers
Please read all instructions before installing
Alpha-numeric CD display
ON/OFF button with
pilot light
Call 800.223.4185 for Technical Support
P.O. Box 4822, Syracuse, NY 13221-4822
Technical Support: 800.223.4185 • www.passandseymour.com
340804 Rev. B 08105
Limited FIVE YEAR Warranty
Pass & Seymour/ egrand will remedy any defect in workmanship or material in Pass & Seymour/ egrand
products which may develop under proper and normal use within five years from the date of purchase by a
consumer:
(1) by repair or replacement, or, at Pass & Seymour/ egrand’s option, (2) by return of an amount equal to the
consumer’s purchase price. Such remedy is IN IEU OF ANY AND A EXPRESSED OR IMP IED WARRANTIES OF
MERCHANTABI ITY OR FITNESS FOR A PARTICU AR PURPOSE. Such remedy by Pass & Seymour/ egrand does
not include or cover cost of labor for removal or reinstallation of the product. A OTHER FURTHER E EMENTS
OF DAMAGE (INCIDENTA OR CONSEQUENTIA DAMAGES) FOR BREACH OF ANY AND A EXPRESSED OR
IMP IED WARRANTIES INC UDING WARRANTIES OF MERCHANTABI ITY OR FITNESS FOR A PARTICU AR
PURPOSE ARE EXC UDED HEREBY. (Some states do not allow disclaimer or exclusion or limitation of incidental
or consequential damages, so the above disclaimers and limitation or exclusion may not apply to you.) ANY
IMP IED WARRANTIES INC UDING WHERE REQUIRED WARRANTIES OF MERCHANTABI ITY OR FITNESS FOR
A PARTICU AR PURPOSE SHA BE IMITED TO THE FIVE YEAR PERIOD SET FORTH ABOVE. (Some states do
not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.)
To ensure safety, all repairs to Pass & Seymour/ egrand products must be made by Pass & Seymour/ egrand or
under its specific direction. Procedure to obtain performance of any warranty obligation is as follows: (1) Contact
Pass & Seymour/ egrand, P.O. Box 4822, Syracuse, NY 13221 for instructions concerning return or repair;
2) return the product to Pass & Seymour/ egrand, postage paid, with your name and address and a written
description of the installation or use of the Pass & Seymour/ egrand product, and the observed defects or failure
to operate, or other claimed basis for dissatisfaction.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
http://waterheatertimer.org/Countdown-timer-horsepower-ratings.html#RT

PR GRAMMING
To program the time switch, you must access the programming buttons that are
located under the ON/OFF button. The wall switch cover plate must be removed
to gain access to the programming buttons.
1. Firmly grasp the side edges of the ock Bar
and gently pull it away from the switch face
until it clicks. Do NOT attempt to pull the
ock Bar off of the switch!
2. Push the ON/OFF button downward so that
it slides down approximately 1/2 inch to
expose the multi-function programming
buttons. The buttons are labeled from right
to left:
Menu/Raise: provides access to the
program items and shows their current
settings. With the first press it shows
Delay time, second shows Sound
setting, third shows Flash setting.
After an item is Selected, the Raise button
can increase the setting or change it from
Off to On. For the Delay setting, when you reach 1200 (12 hours),
pressing Raise brings the display around to 5:00 (5 minutes).
Select/Save: press this while a program item is displaying to change the
setting for the item. When the correct setting is in the display, press this
again to Save the setting for that item.
ower: After an item is Selected, the ower button can reduce the setting
or change it from On to Off. For the Delay setting, when you reach 5:00
(5 minutes), pressing ower brings the display to 1200 (12 hours).
4. Wire the time
switch.
Twist the existing
wires together with
the wire leads on
the time switch
as indicated in the
drawing. Cap them
securely using the
wire nuts provided.
See Fig 4.
• Connect the green
or non-insulated
(copper) GROUND
wire from the circuit
to the GROUND
terminal on the
RT12.
• Connect the power
wire from the circuit
(HOT) to the black
wire on the RT12.
• Connect the wire
to the lamp or fan
( OAD) to the red
wire on the RT12.
• Connect the NEUTRA wires from the circuit to the white wire on the RT12.
5. Put the RT12 in the wall box with the display positioned above the
N/ FF button.
Secure it to the wall box with the screws provided.
6. Restore power to the circuit.
Turn ON the breaker or replace the fuse.
7. Make any necessary programming changes.
See the Programming section for information.
8. Attach the new cover plate.
TOP
INDOORUSEONLY
L
L
Fig 4: Switch orientation, wire connections
and wall box assembly
WARNING
Disconnect power to the wall switch box by turning FF the circuit
breaker or removing the fuse for the circuit before installing the
RT12, replacing lamps, or doing any electrical work.
INSTALLATI N & WIRING
1. Prepare the switch box.
After the power is turned off at the circuit breaker
box, remove the existing wall plate and mounting
screws. Pull the old switch out from the wall box.
2. Identify the type of circuit.
In a Single Pole Circuit (see Fig. 2), two single
wires connect to two screws on the existing
switch. A ground wire may also be present
and connected to a ground terminal on the old
switch. A neutral wire should also be present
in the wall box.
CAUTI N
For your safety: Connecting a proper ground to the time switch provides
protection against electrical shock in the event of certain fault conditions.
If a proper ground is not available, consult with a qualified
electrician before continuing installation.
nly connect the RT12 to a Single Pole Circuit. The RT12 is not suitable for
3-way switching. If the existing wiring does not match the description for a
Single Pole Circuit, you should consult with a qualified electrician.
3. Prepare the wires.
Tag the wires currently connected to the existing switch
so that they can be identified later. Disconnect the wires.
Make sure the insulation is stripped off the wires to expose
their copper cores to the length indicated by
the “Strip Gage” in Fig. 3 (approximately 1/2 inch).
www.passandseymour.com
Fig 2: Typical Single Pole
Switch Wiring
Fig 3: Wire
Stripping
DESCRIPTI N AND PERATI N
The RT12 is a time switch that turns OFF the connected light or fan (load) when
the selected time expires. While the switch is OFF the pilot light behind the
ON/OFF button illuminates and “OFF” appears in the display. When the switch
is ON, the display shows the amount of time the load will remain ON.
For times up to 59 minutes and 59 seconds, the display shows a blinking colon
between the minutes and seconds while the seconds count down continuously.
For times between 1 hour and 12 hours, the display shows a blinking colon
between the hours and minutes and the minutes portion of the display changes
only once a minute. See Fig. 1 for examples.
The RT12’s lighted alpha-numeric display is also used for programming
functions. With the programming functions, you can decide:
•Delay – the amount of time the switch remains ON with the initial press of
the ON/OFF button
•Sound – whether the switch beeps for each button press and every
5 seconds beginning one minute before it turns OFF
•Flash – if the lights flash to warn
you that they are going to turn OFF
in one minute
Manual N
When you press the ON/OFF button, it
activates the Delay timer. If you want to
keep the switch ON for a time different
from what is programmed, simply press
and hold the ON/OFF button until the
display shows the desired time. When you
let go of the button the switch turns ON.
Manual FF
While the switch is ON and the timer is
running, press the ON/OFF button to turn
OFF the connected load without delay.
Changing the amount of time
At any time, you can press and hold the
ON/OFF button for 1 second to restart the timer. It goes immediately to the
programmed Delay time; if you need a different amount of time, keep holding the
button for at least 2 seconds. Hold the button until the display shows the desired
time. Releasing the button starts the timer countdown.
Call 800.223.4185 for Technical Support
Minute
Countdown
Hour
Countdown
Fig. 1: Timer Countdown
The time-out period can be set for 5 minutes
to 12 hours. The time is displayed in two
different ways. For a countdown of less than
an hour, the display shows minutes:seconds.
The seconds count down continuously. If the
countdown is more than an hour, the display
shows hours:minutes, the colon flashes every
second and the display changes every minute.
Seconds
Elapsed
:01
:02
:03
www.passandseymour.comCall 800.223.4185 for Technical Support
340804_RevB_RT12_IS_Eng.qxd:340804_RevB_RT12 IS 9/6/07 10:57 AM Page 5

• Print: 2-sided
• Ink Color: Black
• Paper: White 16lb (60g/m sq)
• Final trim size: 16" (Wide) x 6" (High).
• Four (4) fold.
• Final folded size: 4" (Wide) x 6" (High).
TITLE B X PAGE NLY.
D N T MAKE FILM • D N T PRINT
Pass & Seymour
SYRACUSE, NY
Title:
RT12 Installation Instructions
Drawing #:
06249
Orig. Drawing Da e:
22 FEB 06
Rev. #:
1
SOWINSKI
31 Aug 07
12325
340804
HF
Scale: 1:1
Drawn by
Rev. Da e
AGI Job No.
Par No.
Proofed By
340804_RevB_RT12_IS_Eng.qxd:340804_RevB_RT12 IS 9/6/07 10:57 AM Page 9
Table of contents