INTRODUCTION
The VOTT meter is an ideal engine monitor, which displays data via the J1939 CAN Bus. The
meter utilizes a large LCD screen to simultaneously display DC volts, oil pressure, temperature
and tachometer. It provides accurate digital metering and user programmable alarms. When
alarm thresholds are exceeded, the built-in 85 dB alarm will sound and the aected display
reading will change to RED for the out-of-limit condition. Additionally, a new feature always for
user selectable baud-rate, 50k – 1000k bits/sec.
The meter is waterproof and rugged with a large color LCD display screen. The screen read-out
is divided into 4 display sections allowing the operator quick, and accurate assessment of engine
conditions.
DC volts are displayed from 9.5 – 33.0 VDC. Oil pressure is displayed from 0 – 99 PSI.
Additionally engine temp and RPM are displayed, 100 – 250 F and 0000 – 9999 RPM,
respectively.
The meter is powered by 12-24 VDC. Four levels of backlighting can be selected for optimal
performance. All set-up, calibration and alarm values are saved to non-volatile memory. The
system is complete with all necessary mounting hardware. The large LCD display draws only
0.08 amps at full brightness and only 0.02 in sleep mode. The meter comes with a 3 year
warranty.
ENGINE MONITOR
VOTT
MODEL: 023-4400-0
3 YEAR WARRANTY
INSTRUCTION MANUAL
File: VOTT_023-4400-0
Rev: B
Revised By: PSS/JRN
Date: 01-17-2017
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
1

I. WIRING
The VOTT comes with a 33 inch length six conductor
cable with a Deutsch Connector #DT04_ 6P attached.
The VOTT will operate from 9.5 to 33.0 VDC input. It
displays data via J1939 CAN Bus.
Meter Deutsch connector pin ID is
.
II. MOUNTING
The VOTT requires a 2-1/8” diameter round hole for
mounting. The meter comes with a aluminum U shaped
mounting bracket and #8-32 nuts and lock washers to
secure bracket.
See Figure 1. (FINGER TIGHTEN ONLY, DO NOT USE
TOOLS)
III. MENU NAVIGATION
1. Main Page
When the instrument is powered up it displays the “Main”
page. The “Main” page displays: ENGINE RPM,OIL PSI,
ENGINE TEMP F (OR C) and BATT VOLTS. Values are
displayed in GREEN if within acceptable alarm set limits or
RED if out of limits condition exists.
From MAIN PAGE display:
• Pressing the pkey for ½ second (longer than a quick
press but shorter than 2 seconds) will cause a white
ALARM bell symbol to be displayed and enable the
alarms.
• Pressing the qkey for ½ second (longer than a quick
press but shorter than 2 seconds) will disable the
alarms and remove the white alarm bell symbol.
• Press the “+” key momentarily while an alarm
condition exists will silence the audible and external
alarm as indicating by Red “X”
• Pressing the +key for ½ second (longer than a quick
press but shorter than 2 seconds) will increment the
backlight level through four dierent intensities.
ENGINE RPM
ENGINE TEMP F
OIL PSI
BATT VOLTS
2971 53
125 13.8
Pin Signal Wire Color
1 +9.5- 33.0 VDC Red
2 Power/Signal Ground Black
3 J1939+ Yellow
4 J1939 - Green
5 External buzzer 12
VDC alarm output +
White
6 External buzzer 12
VDC alarm output -
Blue
2-1/8” (55mm)
Hole
Spacing Nut (x2)
Bulkhead Gasket - Pre-Installed on
Rear of Panel
Clamping Nut (x2)
Lock
Washer (x2)
Mounting
Bracket
ENGINE RPM
ENGINE TEMP F
OIL PSI
BATT VOLTS
2971 53
125 13.8
ENGINE RPM
ENGINE TEMP F
OIL PSI
BATT VOLTS
2971 53
125 13.8
x
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
2

2. Menu Tree:
Press *
A) Secured Access Pages
While in the Main page or Generator Hours page, a
Quick press of the *key brings up the Security Access
page and a default number 5000 is displayed in the
ACCESS CODE box.
Use the pand qkeys to scroll to the correct access
code and press “ACCEPT” to enter that number (default
ACCESS CODE is 1234). The longer you hold down
the p or q key, the faster the scrolling of numbers. False
entry results in Main Page being displayed. Entry of
correct access code unlocks the instrument and brings
up the following menu:
B) Category:
I.ALARMS
II.SETUP
III.DETAILS
IV.ABOUT
I. ALARMS Menu:
BATT VOLTS HI
BATT VOLTS LO
OIL PRESSURE HI
OIL PRESSURE LO
ENGINE TEMP. HI
ENGINE RPM HI
<-- BACK
Alarm Ranges:
Engine RPM: 0000 - 9999 is set to 1300 (whole
numbers only)
Oil Pressure: Low/High settable to 00 - 99 (whole
numbers only)
Engine Temp: High settable to 100 - 250
Battery Volts: Low/High settable to 9.0 - 33.0
II. SET UP:
ACCESS CODE
USE DEG C/BARS ( or use DEG F/PSI)
RESET MIN/MAX VALUES (see Details page)
<-- BACK
About
Down Accept Up Quit
ACCESS CODE
USE DEG C/BARS
RESET MIN/MAX VALUES
SET CAN BUS SPEED
< - - BACK
-ACCESS CODE SETTING
If no key has been pressed for 60 seconds from any of
the menus or submenus, the instrument will revert to
displaying the Main Page.
The ACCESS CODE is required to access alarm
settings, and instrument setup menus. Set the ACCESS
CODE to a number from 0000 to 9999 by using the p
and qkeys then press the + key to accept. The factory
default is set to 1234. For S/W: 2.1 or higher default is
set to 4321.
If the ACCESS CODE is ever forgotten, the instrument
can be reset back to factory default. Reset to “Factory
Defaults” by pressing and holding the pand qkeys
while applying DC power. Answer “Yes” by pressing key
labeled “Yes”. This will reset pasword to 1234. Caution:
Resetting to factory default will reset all alarm settings as
well.
-SET CAN BUS SPEED
Serial #’s starting with the letter ‘B’ can be adjusted to
various Can Bus Bit Rates: 50,125,250,500,1000 K Bits.
Units are factory set to 500K.
Alarms
Set Up
Details
About
Setup
Details
About
Down Accept Up Quit
Alarms
Set Up
Details
About
Setup
Details
About
Down Accept Up Quit
Batt. Volts HI
Batt. Volts LO
Oil Pressure HI
Oil Pressure LO
Engine TEMP HI
<-- BACK
Engine RPM HI
116.0
CHANGE
VALUE
DC VOLTS
About
Down Accept Up Quit
ACCESS CODE
USE DEG C/BARS
SET CAN BUS SPEED
< - - BACK
10500
CHANGE
VALUE
BIT RATE KB/S
RESET MIN/MAX VALUES
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
3

-PRESS ACCEPT
The Bit Rate can be changed by accessing the SET UP
category and selecting “SET CAN BUS SPEED” use Up/
Down arrows to set changes in VALUES.
Additional Information:
• Low Oil Pressure only updated if Rpm>100 (ie: engine
running)
• Battery Voltage limited to 99.9 (only 3 digits for display)
• Oil Pressure limited to 99 PSI (only 2 digits for display)
• Engine Temperature 32 deg F (0 deg C) minimum
(avoid negative numbers when in Deg C)
• MaxRpm only updated if Rpm > MaxRpm+10 (help prevent
exceeding max number of Flash writes)
• “LOST COMM” message displayed if no J1939 data
received for 10 or more seconds. Restore display on valid
data or any key
• A press of any button activates/restarts 5 minute alarm
“silence” timer
• Don’t allow INSTRUMENT hours to increment in Sleep
mode
SPECIFICATIONS
Power Supply: 9.50 to 33.00 VDC, @ 80mA
Operating Temperature: 32° to 122° F (0° to 50° C)
Size: 4.3” x 4.3” x 3.5” deep (110 x 110 x 89 mm)
Display Data:
Engine RPM: 0000-9999 ( or as provided by J1939)
On screen title “ENGINE RPM”
Oil Pressure: 0199 PSI (or as provided by J1939).
On screen title “OIL LSI” (factory default).User select-
able for Millibars or European standard. On Screen
“MBRS”.
Engine Temp:100-250° F ( or as provided by J1939)
On screen title “ ENGINE TEMP F” (factory default0.
User selectable for Centigrade, on screen title
”ENGINE TEMP C”
Battery Volts: 9.5 - 33.0 On screen title
”BATT VOLTS”. Displays “COMM LOSS” & red
dashes with loss of J1939 DATA. No alarm on COMM
LOSS.
Accuracy:
Battery Volts: As provided by J1939
Engine RPM : As provided by J1939
Engine Temperature: As provided by J1939
Oil Pressure: As provided by J1939
Alarms: Engine RPM, Low/High Oil Pressure, High Engine
Temp. and Low/High Battery Volts
Alarm Output: 12 VDC, 50 mA max.
III. DETAILS: Displays details page. SN, Min/Max,
Alarm Values, etc.
IV. ABOUT: Displays splash screen, SW version,
HW version and copyright information.
Back Back Back Quit
Kussmaul Electronics
VOTT ENGINE MONITOR
S/W= 20 H/W= XX
www.kussmaul.com
COPR. 2011,2016 Cruzpro LTD.
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
4

All products of Kussmaul Electronics Company Inc. are warranted to be free of
defects of material or workmanship. Liability is limited to repairing or replacing
at our factory, without charge, any material or defects which become apparent in
normal use within 3 years from the date the equipment was shipped. Equipment
is to be returned, shipping charges prepaid and will be returned, after repair, ship-
ping charges paid.
Kussmaul Electronics Company, Inc. shall have no liability for damages of any
kind to associated equipment arising from the installation and/or use of the Kuss-
maul Electronics Company, Inc. products. The purchaser, by the acceptance of
the equipment, assumes all liability for any damages which may result from its
installation, use or misuse, by the purchaser, his or its employees or others.
WARRANTY POLICY
DATE INSTALLED _______________________________________________________
INSTALLED BY _________________________________________________________
VEHICLE IDENTIFICATION _______________________________________________
VEHICLE OWNER _______________________________________________________
INSTALLATION RECORD
170 Cherry Avenue
West Sayville, NY 11796
www.kussmaul.com
Ph: 800-346-0857
Fax: 631-567-5826
5
Table of contents
Other KUSSMAUL Monitor manuals