L3Harris HP-01 User manual

NARDA
Safety
Test
Solutions
S.r.l. Socio Unico
Sales & Support:
Via Rimini, 22
20142 - Milano (MI)
Tel.: +39 02 581881
Fax: +39 02 58188273
Manufacturing Plant:
Via Benessea, 29/B
17035 - Cisano sul Neva (SV)
Tel.: +39 0182 58641
Fax: +39 0182 586400
http://www.narda-sts.it
SERIAL NUMBER OF THE INSTRUMENT
You can find the Serial Number on the upper side panel of the instrument.
The Serial Number is in the form: 000XY00000.
The first three digits and the two letters are the Serial Number prefix, the last five
digits are the Serial Number suffix. The prefix is the same for identical instruments,
it changes only when a configuration change is made to the instrument.
The suffix is different for each instrument
Document HP01EN-10707-1.05 – Copyright © NARDA 2021
User’s Manual
HP-01
MAGNETOMETER
FIELD ANALYZER
From DC up to 1000 Hz

II Note and symbols
NOTE:
® Names and Logo are registered trademarks of Narda Safety Test Solutions GmbH and L3 Communications Holdings, Inc. –
Trade names are trademarks of the owners.
If the instrument is used in any other way than as described in this User’s Manual, it
may become unsafe.
Before using this product, the related documentation must be read with great care and fully understood to
familiarize with all the safety prescriptions.
To ensure the correct use and the maximum safety level, the User shall know all the instructions and
recommendations contained in this document.
This product is a Safety Class III instrument according to IEC classification and has
been designed to meet the requirements of EN61010-1 (Safety Requirements for
Electrical Equipment for Measurement, Control and Laboratory Use).
In accordance with the IEC classification, the battery charger of this product meets requirements Safety Class II
and Installation Category II (having double insulation and able to carry out mono-phase power supply
operations)..
It complies with the requirements of Pollution Class II (usually only non-conductive pollution). However,
occasionally it may become temporarily conductive due to condense on it.
The information contained in this document is subject to change without notice.
KEY TO THE ELECTRIC AND SAFETY SYMBOLS:
You now own a high-quality instrument that will give you many years of reliable service.
Nevertheless, even this product will eventually become obsolete. When that time comes,
please remember that electronic equipment must be disposed of in accordance with local
regulations. This product conforms to the WEEE Directive of the European Union
(2002/96/EC) and belongs to Category 9 (Monitoring and Control Instruments). You can
return the instrument to us free of charge for proper environment friendly disposal. You can
obtain further information from your local Narda Sales Partner or by visiting our website at
www.narda-sts.it .
Warning, danger of electric shock
Earth
Read carefully the Operating Manual and its
instructions, pay attention to the safety symbols.
Unit Earth Connection
Earth Protection
Equipotential
KEY TO THE SYMBOLS USED IN THIS DOCUMENT:
The DANGER sign draws attention to a serious risk to a person’s safety,
which, if not avoided, will result in death or serious injury. All the
precautions must be fully understood and applied before proceeding.
The WARNING sign indicates a hazardous situation, which, if not avoided,
could result in death or serious injury. All the precautions must be fully
understood and applied before proceeding.
The CAUTION sign indicates a hazardous situation, which, if not avoided,
could result in minor or moderate injury.
The NOTICE sign draws attention to a potential risk of damage to the
apparatus or loss of data.
The NOTE sign draws attention to important information.

Contents III
Contents
Page
Safety requirements and instructions…..........…….....………
EC Declaration of Conformity ..........................………………...
VII
VIII
1 General information Page
1.1 Documentation......................................................….……….
1.2 Introduction ……………….....................………………………
1.3 Configuration and Standard accessories...............................
1.4 Optional accessories ..............................................……..
1.5 HP-01 Main specifications..................................………….
1.6 HP-01 panel...................................………..………………..
1-1
1-1
1-3
1-3
1-4
1-5
2 Installation and use Page
2.1 Introduction…………….........................................…...……..
2.2 Preliminary inspection…….............................……...………
2.3 Work Environment………..........................…………..………
2.4 To return for repair…..…..................................……...………
2.5 To clean the meter…….…..…….….................……...………
2.6 Power supply and battery recharging………………………....
2.7 HP-01 connected to a PC………………………………….……
2.8 HP-01 with 8053B ……..…….………………………………….
2.9 Battery management…………….…………………………..….
2.10 Avoiding measurement errors………………………………..
2-1
2-1
2-1
2-1
2-1
2-2
2-3
2-3
2-3
2-4
3 EHP-TS installation Page
3.1 Introduction…………………………………………………..….
3.2 Hardware requirements…………………………...………..….
3.3 Installing HP-TS Software………….………………..………..
3-1
3-1
3-2
4 HP-TS software Page
4.1 HP-TS Applications……………………………………….…….
4.2 HP01-TS Application …...……….........…………………..….
4.2.1 Main menu………………….…………………………….…….
4.2.2 TOT and XYZ modes …………………………………………
4.2.3 Minimized UI ………...…………………………………..……
4.2.4 Info toolbar ...…………………………………………………..
4.2.5 Zero ……….……………………………………………………
4.2.6 Span ….………………………………………………………..
4.2.7 Average ……….……………………………………………….
4.2.8 Wide band …………………………………………………….
4.3 Plot ………...……………………………………………………..
4.3.1 Scale ..………………………………………….………………
4.3.2 Save File .……………………………………………………...
4.3.3 Settings ……………………………………….……………….
4.4 Spectrum section ……………………………………………….
4.5 Waterfall ……………..…………………………………………...
4-1
4-2
4-2
4-4
4-4
4-5
4-5
4-6
4-6
4-7
4-8
4-9
4-9
4-10
4-11
4-13

IV Contents
5 Update Firmware Page
5.1 Update firmware…………..……………………………………..
5.2 To run the update software..…………………………………..
5.3 To transfer data …………………………………………………
5-1
5-1
5-1
6 Uninstalling software Page
6.1 Uninstalling HP-TS Software ………………………..………..
6-1
7 Uninstalling USB-OC Page
7.1 Uninstalling driver for USB-OC……………..……………..…..
7-1
8 Accessories Page
8.1 Introduction………………….………………………………......
8.1.1 Preliminary inspection……..…...…………………………….
8.1.2 Work environment….………………………………………....
8.1.3 Return for repair…………………………………………..…..
8.1.4 Cleaning…………………………………………………..……
8.1.5 Power supply and battery chargers…………………….…..
8.2 USB-OC Optical USB Converter………………………….......
8.2.1 Introduction…………………………………………………….
8.2.2 Installation…………………………………………………......
8-1
8-1
8-1
8-1
8-1
8-2
8-3
8-3
8-3
9 Communication protocol Page
9.1 Disclaimer………………………………………………………..
9.2 Protocol ………………………………………………………….
9.3 Leds behaviour ………………………………………………….
9.4 HP-01 COMMANDs…………………………………………….
9.4.1 Query Commands ……………………………………………
9.4.2 Setting COMMANDs………………………………………….
9.4.3 Analyzer reply………………………………………………….
9-1
9-1
9-2
9-3
9-4
9-10
9-12

Contents V
Figures
Figure
Page
1-1
1-2
3-1
3-2
3-3
3-4
3-5
3-6
3-7
3-8
4-1
4-2
4-3
4-4
4-5
4-6
4-7
4-8
4-9
4-10
4-11
4-12
4-13
4-14
4-15
4-16
4-17
4-18
4-19
4-20
4-21
4-22
4-23
4-24
4-25
5-1
5-2
5-3
5-4
5-5
5-6
5-7
5-8
Sensor position …………………………………….
Panel of the HP-01 …………….…………………..
Setup icon …………………………………………..
Run as administrator ………………………………
HP-TS Installation…………………………………..
Installation folder …………………………………..
Ready to install …………………………………….
Installing HP01-TS ………………………………..
Installation successful …………………………….
Reboot ………………………………………………
HP01-TS icons …………………………………….
Welcome logo ……………………………………..
HP01-TS main window .…….……………….……
Total and XYZ display ………………………….….
Minimized UI ……………………………………….
Info toolbar …………………………………………
Zero Gauss Chamber ……………………………..
Zeroing ……………………………………………..
Successful zeroing ......……………………………
Span selector ………………………………………
Averaging …………………………………………..
Plot graph ….…………………………………….….
Scale selector ………………………………………
Settings and Save buttons ………………………..
Save file …………………………………………….
Plot Total ……………………………………….……
Settings ……………………………………………..
Spectrum graph ……..……………………………..
Span selection …………………………………..….
Waterfall screen ……………………………………
OpenGL version warning ………………………….
Waterfall – 2D Graph …..………………………….
2D Marker …………………………………………..
Export tool …………………………………………..
Waterfall – 3D Graph ……………………………...
Update software icons ……………………………..
HP-01 Upgrading utility main window ..…….........
Switch HP-01 on …..……………………………….
Update firmware …..…………………………….…
Update firmware button ..……………………….…
Error message …..…………………………….……
Progressive bar …………………………………….
Flashing terminated ………………………………..
1-2
1-5
3-1
3-2
3-2
3-3
3-3
3-4
3-4
3-4
4-1
4-2
4-2
4-4
4-4
4-5
4-5
4-5
4-5
4-6
4-6
4-8
4-9
4-9
4-9
4-10
4-10
4-11
4-12
4-13
4-13
4-14
4-14
4-15
4-15
5-1
5-1
5-2
5-2
5-2
5-3
5-3
5-3

VI Contents
6-1
6-2
6-3
6-4
7-1
7-2
7-3
7-4
8-1
Uninstall icon .………………………………………
Uninstalling HP01-TS ….………………………….
File remove confirmation request ………………..
Uninstallation successful …………………………..
Control panel ………………………………………..
Application installation ……………………………..
Uninstalling USB-OC…………………………….…
Uninstaller messages .…………………………….
USB-OC adapter ..…………………………….……
6-1
6-1
6-2
6-2
7-1
7-1
7-2
7-2
8-3
Tables
Table
Page
1-1
8-1
Technical Specifications of the HP-01….….........
USB-OC Technical Specifications …………….…
1-4
8-3

EC Conformity VII
SAFETY RECOMMENDATIONS AND INSTRUCTIONS
This product has been designed, produced and tested in Italy, and it left the factory in conditions fully
complying with the current safety standards. To maintain it in safe conditions and ensure correct use,
these general instructions must be fully understood and applied before the product is used.
•In case of devices permanently connected to the power supply, and lacking any fuses or other
devices of mains protection, the power line must be equipped with adequate protection
commensurate to the consumption of all the devices connected to it;
•Devices in Safety Class I, equipped with connection to the power mains by means of cord and plug,
can only be plugged into a socket equipped with a ground wire;
•Any interruption or loosening of the ground wire or of a connecting power cable, inside or outside the
device, will cause a potential risk for the safety of the personnel;
•Ground connections must not be interrupted;
•To prevent the possible danger of electrocution, do not remove any covers, panels or guards installed
on the device, and refer only to NARDA Service Centers if maintenance should be necessary;
•To maintain adequate protection from fire hazards, replace fuses only with others of the same type
and rating;
•Follow the safety regulations and any additional instructions in this manual to prevent accidents and
damages.
DANGER BY HIGH FORCES IN STATIC FIELDS
Danger: high static magnetic fields – as found, for example, around an MRI or NMR spectroscopy
magnet – will subject the USB connector or other ferromagnetic parts to strong forces.
To prevent injury from flying objects or whiplashing cables, be sure to hold these components securely
when you are around a strong magnet.

VIII Safety Consideration
Dichiarazione di Conformità
EC Declaration of Conformity
In accordo alla Decisione 768/2008/EC, conforme alle direttive EMC 2014/30/UE, Bassa Tensione 2014/35/UE e RoHS
2011/65/UE, ed anche alle norme ISO/IEC 17050-1 e 17050-2.
In accordance with the Decision 768/2008/EC, compliant to the Directives EMC 2014/30/EU, Low Voltage 2014/35/EU
and RoHS 2011/65/EU, also compliant to the ISO/IEC standard 17050-1 and 17050-2
Il costruttore
The manufacturer
narda Safety Test Solutions S.r.l. Socio Unico
Indirizzo
Address
Via Benessea, 29 / B
I-17035 Cisano sul Neva (SV) - Italy
sulla base delle seguenti norme europee armonizzate, applicate con esito positivo:
based on the following harmonized European Standards, successfully applied:
EMC - Emissioni:
EMC - Emission:
EN 61326-1 (2013)
EMC - Immunità:
EMC - Immunity:
EN 61326-1 (2013)
Sicurezza:
Safety:
EN 61010-1 (2010)
dichiara, sotto la propria responsabilità, che il prodotto:
declares, under its sole responsibility, that the product:
Descrizione
Description
MAGNETOMETRO – ANALIZZATORE DI CAMPO
MAGNETOMETER – FIELD ANALYZER
Modello
Model
HP-01
è conforme ai requisiti essenziali delle seguenti Direttive:
conforms with the essential requirements of the following Directives:
Bassa Tensione
Low Voltage
2014/35/EU
Compatibiltà Elettromagnetica
EMC
2014/30/EU
RoHS
RoHS
2011/65/EU
Cisano sul Neva, 03 May 2017 Egon Stocca
General Manager

General Information 1-1
1 - General information
1.1 Documentation
The following documents are included in this Manual:
•A questionnaire to be sent to NARDA together with the apparatus
should service be required.
•A checklist of the Accessories included in the shipment.
This Manual includes description of HP-01 standard and optional
accessories.
1.2 Introduction
This section provides a general overview of HP-01 Magnetometer - Field
Analyzer.
HP-01 is a magnetic DC and low frequency isotropic field probe-analyzer. It
provides an advanced technology solution for field analysis in the DC to 1
kHz frequency range in an extremely high dynamic range. It includes X, Y
and Z axes simultaneous measurements with a powerful, built in, spectrum
analyzer.
HP-01 can be used either connected to 8053B, NBM-550 portable field
meters or PC.
HP-01 includes a non volatile memory which stores frequency and level
calibration tables and an internal optical repeater which allows connection
to external devices through the optical fibre.
Spectral analysis, obtained through DSP (Digital Signal Processor), is
performed on different frequency Span values and displayed on the PC
monitor.
Marker function is available to provide accurate field strength and
frequency measurement.
HP-01 is managed internally with a microprocessor that controls all the
main functions, from the battery charging to the serial communication with
the DSP unit.
The Magnetic field is picked up by three sensors on the X, Y and Z
orthogonal axes. A Digital/Analog conversion follows which transforms the
signal into numeric information processed by a Digital Signal Processing
unit.
HP-01 is housed in a small cylindrical housing. The bottom side panel
includes an optical fibre connector, extension rod screw, battery charger
connector, ON/OFF button and Status LEDs.
The magnetic sensor system is composed by three Hall effect elements,
positioned orthogonal to each other.
Document HP01EN-10707-1.05 - © NARDA 2021

1-2 General Information
The notch near the end of the tip marks the sensor position.
The orientation of the three axis is depicted onto the top panel.
Fig. 1-1 Sensor position

General Information 1-3
1.3 Configuration and
Standard Accessories
The HP-01 Set for NBM-550 and PC use, includes the following items:
•HP-01 Basic Unit;
•Zero-Gauss Chamber;
•AC/DC Converter with plug adapters;
•Cable, FO Duplex, RP-02, 10 m;
•USB-OC Optical Converter;
•Cable, FO Duplex, RP-02, 25 cm;
•Conical Tripod support;
•HP-01 / NBM Adapter
•Carrying Case 170/37;
•HP-TS Software, CD-ROM including User’s Manual;
•Cerfiticate of Calibration.
The HP-01 Set for 8053B and PC use, includes the following items
(available for Italy only):
•HP-01 Basic Unit;
•Zero-Gauss Chamber;
•AC/DC Converter with Italian plug adapters;
•Cable, FO Duplex, RP-02, 10m;
•USB-OC Optical Converter;
•Cable, FO Duplex, HFBR, 10m;
•Conical Tripod support;
•Carrying Case 170/37;
•HP-TS Software Media including User’s Manual;
•Cerfiticate of Calibration.
1.4 Optional Accessories
The following accessories may be ordered as options:
•Cable, FO Duplex, RP-02, 20m;
•Cable, FO Duplex, RP-02, 40m.
•100% Wooden tripod TR-03

1-4 General Information
1.5 HP-01 Main
specifications
When not differently specified the following specifications are referred to an
operating ambient temperature of 23°C and relative humidity 50%.
Table 1-1 Technical specifications of the HP-01 Magnetometer - Field Analyzer
Frequency range DC ÷ 1000 Hz
Measurement range
(1)
10 µT ÷ 60 mT
(lower range)
10 mT ÷ 10 T
(higher range)
10 µT ÷ 10 T
(advanced autoranging feature)
Overload 20 T
Dynamic range
(after zeroing)
120 dB
Resolution
(2)
100 nT
(lower range)
100 µT
(higher range)
Displayed average noise level
(3)
10 µT
Frequency flatness
(typ)
0.5 dB
(DC ÷ 1000 Hz)
Expanded Measurement Uncertainty
(4)
1%
Field sensor Triaxial orthogonal Hall effect devices
(temperature compensated)
Sensor area approx.: 0.6 x 0.6 mm
(higher range)
0.15 x 0.15 mm
(lower range)
Acquisition method Simultaneous triaxial acquisition
Spectrum analysis method Realtime Gapless
(5)
FFT
SPAN 20 Hz 30 Hz 100 Hz 1000 Hz
Frequency resolution 0.2 Hz 0.3 Hz 1 Hz 3 Hz
RBW
(-3 dB)
0.8 Hz 1.2 Hz 4 Hz 10 Hz
Reading update time < 350 ms
Start frequency User selectable within the whole range
Stop frequency User selectable within the whole range
Time domain analysis method DC to 1 Hz FIR filter 1 Hz (-3dB), reading updating time 67 ms
Calibration
(6)
internal E
2
PROM
Temperature and humidity meter -20 to +55 °C 0.01° resolution 5 to 95 % 0.1% resolution
Typical temperature deviation
@ 0 Hz referred to 23°C
0.05% / °C
Dimensions Sensor stick φ9 mm, L 143 mm
Main body φ43 mm, L 55 mm
Overall length 200 mm
Weight 100 g
Tripod support Threaded insert ¼”
Internal battery 3.7 V / 250 mAh Li-Ion, rechargeable
Operating time > 6 hours
Recharging time < 2.5 hours
External supply 10 ÷ 15 VDC, I = approx. 100 mA
Optical fiber connection Serial Optical Interface 115200 Baud
(7)
- RP02 connector
up to 40 m (USB-OC)
Firmware updating Through the optical link by USB or RS232
Self test Automatic at power on
Operating temperature -20 to +55 °C
Operating relative humidity
(8)
5 to 95 %
Charging temperature 0 to +40°C
Storage temperature -30 to +75°C
(1) For each single axis. Positive and negative at DC.
(2) At 20 Hz and 30 Hz SPA .
(3) After zeroing. DA L is frequency and SPA depending. The specified performance is referred to 0 Hz and SPA 20 Hz.
(4) At DC.
(5) Overlapping for SPA lower than 1000 Hz
(6) Recommended re-calibration interval 24 months
(7) 38400 Baud with 8053B
(8) Without condensation
Specifications are subject to change without notice

General Information 1-5
1.6 HP-01 Panel
Key:
1. Power-on LED
2. Battery charger connector
3. ON/OFF button
4. Fiber optic connector
5. Data LED
Fig. 1-2 Panel of HP-01

1-6 General Information
This page has been intentionally left blank

Installation and use 2-1
2 - Installation and use
2.1 Introduction
This section provides the information required for installing and using the
HP-01 Analyzer.
Information is included regarding initial inspection, power requirements,
interconnections, work environment, assembly, cleaning, storage and
shipment.
2.2 Preliminary
inspection
Inspect the packaging for any damage.
If the packaging or anti-shock material have been damaged, check
that the contents are complete and that the meter has not suffered
electric or mechanical damage.
Check that all the Accessories are there against the checklist found
with the apparatus.
Inform the carrier and NARDA of any damage that has occurred.
2.3 Work environment The work environment of the Accessories, must come within the following
conditions:
•Temperature
•Humidity
From -20°C to +55°C
5 to 95% relative
The meter must be stored in a clean and dry environment, free from acid
dusts and humidity.
The storage environment must come within the range of the following
conditions:
•Temperature
•Humidity
From -30°C to + 75°C
< 100% relative without condense
2.4 To return for repair When the meter needs to be returned to NARDA for repair, please
complete the questionnaire appended to this User’s Manual, filling in all the
data that will be useful for the service you have requested.
For reducing the period of time required for the repairs, it is necessary to be
as specific as possible in describing the problem. If the problem only occurs
in certain circumstances, please describe in detail how it happens.
If possible it is better to reuse the original packaging; making sure that the
apparatus is wrapped in thick paper or plastic.
Otherwise, use strong packaging by using a sufficient quantity of shock
absorbent material around all sides of the meter to ensure that it is compact
and does not move around inside the package.
In particular, take every precaution to protect the front panels.
Finish the package by sealing it up tightly.
Apply a FRAGILE label to the package to encourage greater care in its
handling.
Nowadays there are restrictions on the shipment of hazardous materials,
eg. some types of lithium batteries.
Please, check the proper, safe, shipping mode, with the help of your
courier, in the case the product is equipped with batteries.
2.5 To clean the meter
Use a dry, clean and non-abrasive cloth for cleaning the meter.
Do not use solvents, acids, turpentine, acetone or other similar
products for cleaning the meter in order to avoid damaging it.
Document HP01EN-10707-1.05 - © NARDA 2021

2-2 Installation and use
2.6 Power supply and
battery recharging
HP-01 has an internal rechargeable Li-Ion battery that can be recharged
with the battery charger supplied with it.
Make a full charging cycle before using the Analyzer for longest battery
operation time.
ALWAYS connect the battery charger to the power supply BEFORE
connecting it to the HP-01.
The battery charger has an internal protective circuit that will limit the
output of current if there is any load when connecting to the mains.
Battery charger:
output: DC, 10 - 15 V, ~ 100 mA
Connector:
+
-
In order to safeguard the features of the batteries, it is crucial to have
a complete recharge before storing them for periods longer than 4
months. Therefore, it is warmly suggested recharging the batteries at
least every 4 months even though the device has not been used.
The minimum voltage level for operation is about 3.25V. The batteries
must be recharged for lower voltages. Below such voltage the
analyzer will turn OFF automatically.
The time required for recharging the batteries is about 2.5 hours.
When the recharge is complete, this is indicated by the Led of the HP-
01, with a rapidly blinking Green light.
To take measurements ALWAYS remove the battery charger from the
HP-01 Analyzer otherwise the system does not work.
The battery status is reported by the HP-01 control program
When charging is in progress the connection to the probe is not available.

Installation and use 2-3
2.7 HP-01 connected
to a PC
Using the HP-TS software spectrum analysis can be displayed on a PC
Switch the unit on with a short key press of the Power button to set
the probe for communication with HP-TS pc software.
2.8 HP-01 with
8053B
HP-01 is linked to 8053B via the fiber optic link.
Switch the unit on with a short key press of the Power button, wait 2
seconds and press the key a second time until the ON LED lights up
to set the probe for communication with 8053B.
Please, see 8053B Manual for further details
2.9 Battery
management
The battery autonomy of the Analyzer depends on its mode of operation.
It is designed to be more than 6 hours.

2-4 Installation and use
2.10 Avoiding
measurement errors
We recommend that the probe be set up a long way from metal objects or
masses to avoid disturbance of the magnetic field.
The support must be amagnetic to perform correct measurements.
Using an unsuitable support could influence the measurements and,
therefore, determine incorrect results. We recommend always using
the amagnetic extension support supplied with HP-01 for supporting
the Analyzer.
The intensity of the measured field mainly depends on its
currents
and the geometry of the system under examination as well as the
distance between the conductors/magnets and the measurement
points. In the vicinity of cables, the reading of the field value may be
very high and vary with the location of the probe.

HP01-TS software 3-1
3 – HP01-TS installation
3.1 Introduction
HP01-TS is a useful software tool developed for remote PC control, through
fibre optic link, of HP family Magnetometers and field analyzers.
By means of the USB-OC optical to USB converter, HP-01 can be
connected to a PC USB port.
If needed, the selected COM port should be assigned to the application
software (see cap.5 HP01-TS applications).
HP01-TS software requires an analyzer is connected to PC in order to run.
The HP01-TS installation program automatically installs the driver for USB
optical converter.
3.2 Hardware
requirements
Minimum requirements:
•Processor: Pentium or equivalent
•256 MB RAM
•At least 64 MB of free space on hard disk
•1 free USB port
•Windows Operating systemXP/Vista/Win7/Win8.1/Win10
The User might have the need of administrator privileges to install the
software in Windows Vista, Windows 7, Windows 8.1 and Windows
10. For further information, please see the next paragraph.
The new releases can be downloaded directly from the narda website.
http://www.narda-sts.it
1
Document HP01EN-10707-1.05 - © NARDA 2021

3-2 HP01-TS software
3.3 Installing HP01-TS
Software
Before connecting the Magnetic field analyzer to PC the HP01-TS software
installation should be performed:
Double click on the file “HP01-TS Setup.exe” included on Software Media
Fig. 3-1 Setup icon
The User must have administrator privileges to install the HP01-TS
software in Windows Vista, Windows 7, Windows 8.1 and Windows 10;
right click on the program .exe file and click on “Run as administrator”
to temporarily run the program or application as an administrator until
close it (Windows 7 also allows to mark an application so that it
always runs with administrator rights).
Fig. 3-2 Run as administrator
Follow set-up program instructions
Fig.3-3 HP01-TS installation
Table of contents