manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Labgear
  6. •
  7. Media Converter
  8. •
  9. Labgear MRX700 User manual

Labgear MRX700 User manual

Introduction
The MRX700 converts the SCART output from
a set top box to an RF2 output which will power
DigiLink eyes allowing viewing and control
from TV sets around the home.
With an additional RF output for your main TV
and optional SCART loop-through.
Compatible with old and new Sky™, Sky+™
and Sky+HD™ boxes* also compatible with
Freesat™/Freeview™ receivers & PVRs.
• Comes with two IR transmitters for control of
up to two devices (connected via the SCART IN)
• RF2 DC output 9VDC, 100mA to power DigiLinks
• RF2 output suitable for distribution via
DigiLink compatible ampliers.
• RF IN allows aerial and CATV signal distribution
• Fully compatible with new and existing TV
distribution systems
• Allows the use of existing RF Link devices used to
distribute Sky™ signals and control remotely Sky™receivers
Please Note: Older Sky boxes with RF2 outputs
can be connected via the MRX700 RF input
and additional STB(s) via the SCART.
Newer Sky boxes with no RF output will need
to be connected via the LabLink SCART input.
MRX700 - DigiLink SCART to RF Converter Kit
compatible with new Sky™/Freesat™/Freeview™ receivers & PVRs
For further information or any queries please contact
Customer Careline: 08457 573 479
(Local rate – UK only)
www.labgear.co.uk
Waste electrical products should not
be disposed of with household waste.
Please recycle where facilities exist.
Check with your Local Authority for
recycling advice.
© Philex Electronic Ltd. 2014 V1.1
Labgear Reserve the right to modify their designs or specications, In the light of future developments, without
prior notice. Performance gures quoted are typical and subject to normal manufacturing and service tolerances
General Safety Precautions
• To prevent re or shock hazard, do not
expose this device to rain or moisture.
• This product is for indoor use only
• Do not expose the product to extreme heat
• Do not use the product close to water.
• Do not open this unit it contains no user
serviceable parts. Refer servicing to
qualied personnel only.
• This device should be operated using only
the power supply included with it or one
with an identical rating.
• Do not overload wall outlets and extension
cords as this can result in the risk of re or
electrical shock.
Care
To clean wipe gently with a soft non- abra-
sive cloth. The cloth can be slightly moist-
ened with a diluted mild detergent solution
providing the aerial is rst switched o and
disconnected from the power supply.
41
Specications and Safety Precautions
17
8
2
3
4
6
1
5
7
8
2
9
4
6
9
5
10
10
AV Input - SCART Socket for audio and
video signal input.
AV Output - SCART Socket for audio and
video signal by-pass output
Power Switch - Turns power ON/OFF.
Power Display Window - Red LED indicates
power ON/OFF
IR Socket - Connection for IR transmitters.
RF2 output - 1. Modulated AV signal combined
with RF IN signal - also provides DC 9V/100mA
(max.) to power DigiLink
RF1 Output - Modulated AV signal combined with
RF IN signal output from this port
RF IN Port - Input for aerial / CATV signals with
0~5dB bandwidth gain.
DC Input - Connection for 9VDC/600mA power adaptor.
IR Transmitters- Placed over IR sensors of STBs to
transmit remote control signal from remote location
1
7
8
2
3
4
6
9
5
10
Modulator
Standard: PAL G / I
Frequency: UHF 470 - 860MHz
Output Level: 72±4 dBµV
Gain: 0-5dB (RF in to RF out)
Sound system: Mono
Power Supply Input: 110-220V~50/60Hz, 0.25A
Power Supply Output: 9V𝌂600mA
Video input: 1.0Vp-p/75Ω
Audio input: 1.0Vp-p/600Ω
DC output (RF2): 9VDC/100mA (max.)
A/V Connector: SCART sockets
RF Connector: F type
Dimensions: 116mm x 78mm x 35mm
Weight: 115g
IR Transmitter
Connector: 3.5mm Socket
Peak wavelength: 940nm
View Angle: 40˚
Cable length: 800mm
Specications
Installation InstructionsInstallation Instructions
3
2
MAIN
TV
TV
TV
DigiLink
Sky+HD Receiver
TV
I/O Port
Dish IN
DigiLink compatible
amplier with bypass
DigiLink
DigiLink
DigiLink
IR Transmitter
attaches to front of
STB over sensor
RF2 signal
plus aerial
signal
RF1
OUT
RF2
OUT
RF IN
Note: DigiLinks and leads
shown are not supplied
Connection Guide
8 Pin Dip switch Settings
CH. Switch status ON=“1” OFF=”O”
CH. Frequency 1 2 3 4 5 6 7 8
21 471.25 X 1 0 0 0 0 0 0
22 479.25 X 1 0 0 0 0 0 1
23 487.25 X 1 0 0 0 0 1 0
24 495.25 X 1 0 0 0 0 1 1
25 503.25 X 1 0 0 0 1 0 0
26 511.25 X 1 0 0 0 1 0 1
27 519.25 X 1 0 0 0 1 1 0
28 527.25 X 1 0 0 0 1 1 1
29 535.25 X 1 0 0 1 0 0 0
30 543.25 X 1 0 0 1 0 0 1
31 551.25 X 1 0 0 1 0 1 0
32 559.25 X 1 0 0 1 0 1 1
33 567.25 X 1 0 0 1 1 0 0
34 575.25 X 1 0 0 1 1 0 1
35 583.25 X 1 0 0 1 1 1 0
36 591.25 X 1 0 0 1 1 1 1
37 599.25 X 1 0 1 0 0 0 0
38 607.25 X 1 0 1 0 0 0 1
39 615.25 X 1 0 1 0 0 1 0
40 623.25 X 1 0 1 0 0 1 1
41 631.25 X 1 0 1 0 1 0 0
42 639.25 X 1 0 1 0 1 0 1
43 647.25 X 1 0 1 0 1 1 0
44 655.25 X 1 0 1 0 1 1 1
45 663.25 X 1 0 1 1 0 0 0
46 671.25 X 1 0 1 1 0 0 1
47 679.25 X 1 0 1 1 0 1 0
48 687.25 X 1 0 1 1 0 1 1
49 695.25 X 1 0 1 1 1 0 0
50 703.25 X 1 0 1 1 1 0 1
51 711.25 X 1 0 1 1 1 1 0
52 719.25 X 1 0 1 1 1 1 1
53 727.25 X 1 1 0 0 0 0 0
54 735.25 X 1 1 0 0 0 0 1
55 743.25 X 1 1 0 0 0 1 0
56 751.25 X 1 1 0 0 0 1 1
57 759.25 X 1 1 0 0 1 0 0
58 767.25 X 1 1 0 0 1 0 1
59 775.25 X 1 1 0 0 110
60 783.25 X 1 1 0 0 1 1 1
61 791.25 X 1 1 0 1 0 0 0
62 799.25 X 1 1 0 1 0 0 1
63 807.25 X 1 1 0 1 0 1 0
64 815.25 X 1 1 0 1 0 1 1
65 823.25 X 1 1 0 1 1 0 0
66 831.25 X 1 1 0 1 1 0 1
67 839.25 X 1 1 0 1 1 1 0
68 847.25 X 1 1 0 1 1 1 1
69 855.25 X 1 1 1 0 0 0 0
NOTE: “X” Set to1 for Video In or 0 for Test Bars
Channel Selection
Use the dip switch on the base of the MRX700
to select a channel between 21 and 59 (see table
to the right). You need to select a channel that is
not used by your local transmitter or adjacent to
it. Also avoid Ch 60-69 which is used for some 4G
mobile phone transmissions.
To check your local transmitter channels go to:
www.digitaluk.co.uk/coveragechecker/
enter your postcode and check “Detailed view”
the channels are listed here. Pick a channel that is
3 to 4 (but not 5*) away from any of the channels
listed for your transmitter.
*Avoid multiples of 5 as these can be eected by harmonics
Please Note:
A DigiLink compatible distribution amplier
is required for multiple room systems.
A DigiLink device is required at each TV
location (not supplied).
Additional remote controls may be required.
This example shows a new Sky+HD™ box
connected via the SCART input. Older Sky™
boxes with RF2 outputs can be connected
via the MRX700 RF input and an
additional STB(s) via the SCART.

Popular Media Converter manuals by other brands

C&C TECHNIC Smart View VSS-814PF user manual

C&C TECHNIC

C&C TECHNIC Smart View VSS-814PF user manual

austriamicrosystems AS5043 Operation manual

austriamicrosystems

austriamicrosystems AS5043 Operation manual

Matrox 6150 Encoder user guide

Matrox

Matrox 6150 Encoder user guide

Kaiser Baas KBA03052 user guide

Kaiser Baas

Kaiser Baas KBA03052 user guide

Emotiva Little Ego user manual

Emotiva

Emotiva Little Ego user manual

Dometic SMP 301 installation manual

Dometic

Dometic SMP 301 installation manual

CYP CM-388 Operation manual

CYP

CYP CM-388 Operation manual

Cadenceberge CAD-HV-HE04 product manual

Cadenceberge

Cadenceberge CAD-HV-HE04 product manual

Teradek beam user guide

Teradek

Teradek beam user guide

Sunricher SR-2102B(WP) manual

Sunricher

Sunricher SR-2102B(WP) manual

DEVA Broadcast DB9009-TX Maintenance and operation instruction manual

DEVA Broadcast

DEVA Broadcast DB9009-TX Maintenance and operation instruction manual

Linear Technology DC257 Demo Manual

Linear Technology

Linear Technology DC257 Demo Manual

Avenview SPLIT-HDM2-T4K-2 manual

Avenview

Avenview SPLIT-HDM2-T4K-2 manual

QSI Quantum Electric Q1a Operation manual

QSI

QSI Quantum Electric Q1a Operation manual

Gilson SP-245 operating manual

Gilson

Gilson SP-245 operating manual

RME Audio ADI-8 DS user guide

RME Audio

RME Audio ADI-8 DS user guide

Ground Zero GZCV 2.0HL owner's manual

Ground Zero

Ground Zero GZCV 2.0HL owner's manual

Goepel Easy CON-1000Base-T1 manual

Goepel

Goepel Easy CON-1000Base-T1 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.