Dynamics section
There are three modes of operation :
1) Hard Limit « HL ». Limiter will not allow peaking value set above set ‘TRESH’
value. If the signal level exceeds the set value the gain of the circuit is reduced by
the control side chain so that the level of the ouput signal equals the threshold set
value. Once the side chain has been activated, the gain is restored under the
control of the circuit time constants. The compression ratio of the Hard Limit
mode is typically greater than 100:1.
2) Soft Limit « SL ». Module operates as a compressor/limiter, giving increasing
compression with increasing signal over threshold. In this mode, the compression
ratio gradually increases from 1.5:1 for an input signal amplitude equal to the
threshold set level, reaching 100:1 for a signal 20dBs above the threshold level.
3) Noise Gate « GATE ». Module operates as a noise gate, reducing the noise floor
by 15dB. In this mode the threshold is 50dB below that marked on the control.
Signals below the threshold level set the path gain to -25dB. If the signal then
increases a defined amount above the threshold the path gain reverts to OdB.
This built in hysteresis prevents the gate switching indecisively for marginal signal
levels and is approximately lOdBs. The GATE ON/OFF switching time constants
are approximately 20mS to prevent audible 'Fourier' clicks.
4) THRESH. Sets the level at which the three circuit functions operate, with
modification explained in point (3).
5) « FAST » switch. Pressing the button decreases an internal time constant by 10:1.
This ratio is modified by the limiting mode selected, giving a resultant attack time
ratio, with and without « FAST » selected, of 4 :1 with HARD LIMIT selected and
10 :1 with SOFT LIMIT selected. With both FAST and HARD LIMIT selected, he
attack time is 250㎲.
6) «Arrow»switch. Allows the control sidechain of the circuit to activate the
adjacent channel's DYNAMICS module, allowing 2 modules to be grouped
together. The circuit is designed so that the highest control voltage of a group of
linked units controls the group
7) IN. When selected the dynamics module is operative. When deselected the
module may still activate the adjacent channel's control sidechain.
8) Limiting LED. This LED illuminates when there is a gain reduction through the
module of 3dB or more. En Gate mode, Led lights off when the signal level is
above the set threshold and gate opens.
Signal presence / Overload indicator :
Signal indicator is full wave rectified and the peak value of the input signal is stored. This
voltage is compared with the voltage on the signal threshold input (set to 0dB by
default) and if greater the SIG LED is turned on. Attack time = 2mS and release time =
1. 5 S approx.