Lacanche L2HM 900 User guide

L2HM 900 - L2HM 1000 - L2HM 1100 - L2HM 1200
L2HM 1300 - L2HM 1500 - L2HM 1600 - L2HM 1700
L2HM 1700 - L2HM 1800 - L2HM 2000 - L2HM 2100 - L2HM 2200 - L2HM 2400
LACANCHE KITCHEN RANGE
HOODS
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 1/28

TECHNICAL DATA SHEETS, MEASUREMENTS AND DIMENSIONS
—————————————————————————————————————————3
INSTALLER’S MANUAL 7
SITTING
—————————————————————————————————————————9
SETTING UP THE HOOD
—————————————————————————————————————————13
SETTING UP OF GROUPS
—————————————————————————————————————————17
INSTALLING THE EXTRACTOR HOOD EXTENSION
—————————————————————————————————————————20
INSTALLING MOUNTING CHANNEL COVERS
—————————————————————————————————————————22
USER’S MANUAL 23
USE
—————————————————————————————————————————25
CLEANING AND MAINTENANCE
—————————————————————————————————————————26
Note concerning the disposal of waste electrical and electronic equipment
—————————————————————————————————————————28
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 2/28

INSTALLER’S MANUAL
AB
L2HM 900 900 385
L2HM 1000 1000 485
L2HM 1100 1100 585
L2HM 1200 1200 685
L2HM 1300 1300 785
L2HM 1500 1500 985
L2HM 1600 1600 1085
L2HM 1700 1700 1185
L2HM 1800 1800 1285
L2HM 2000 2000 1485
L2HM 2200 2200 1685
L2HM 2400 2400 1885
TECHNICAL DATA SHEETS, MEASUREMENTS
AND DIMENSIONS
B
A
73.5~
80
Axe de sortie murale
Hotte LHM
Axe de sortie murale
Hotte LHME
Axe de sortie murale/centrale
Hotte LHM - LHME
Raccordement électrique
Hotte LHM - LHME
305 - Axe de sortie centrale
Hotte LHM
225 - Axe de sortie centrale
Hotte LHME
495
90
155165
L
15
750
725
650
596
2400
100
70
1820
890
580
0 à 240
40
930
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 3/28

INSTALLER’S MANUAL
LACANCHE KITCHEN RANGE HOODS
- Decorative single and double blower unit kitchen range hoods in canopy widths from 900 to 2 000 mm.
CAUTION :
Under no circumstances shall the distance between the exhaust hood and the wall or
ceiling exhaust opening exceed 9 metres.
Make sure that the support surface and fixings used are able to take the weight of
the hood.
Before drilling any holes, make sure that there are no electric cables, gas pipes or
other ducts or piping running through the wall (in the areas concerned).
As far as possible, it is advisable to mount the hood on a solid support surface.
- Stainless steel or black, white or color epoxy-coated shell.
- Adjustable duct cover.
- Single (L2HM 90-1100) or double blower units (other models), featuring.
- Max. sound levels of 52 dB(A) (at 1 m of unit).
- Top or side exhaust.
TECHNICAL DATA SHEETS, MEASUREMENTS
AND DIMENSIONS
Blowers Blower units Exhaust duct
diameter
L2HM 900 874 1 125 mm 327 m3/ 384 Pa
L2HM 1000 874 1 125 mm 327 m3/ 384 Pa
L2HM 1100 874 1 125 mm 327 m3/ 384 Pa
L2HM 1200 878 1 150 mm 627 m3/ 383 Pa
L2HM 1300 878 1 150 mm 627 m3/ 383 Pa
L2HM 1500 878 1 150 mm 627 m3/ 383 Pa
L2HM 1600 878 1 150 mm 627 m3/ 383 Pa
L2HM 1700 874 2 2 x 125 mm 654 m3/ 384 Pa
L2HM 1800 874 2 2 x 125 mm 654 m3/ 384 Pa
L2HM 2000 874 2 2 x 125 mm 654 m3/ 384 Pa
L2HM 2100 874 2 2 x 125 mm 654 m3/ 384 Pa
L2HM 2400 878 2 2 x 150 mm 1254 m3/ 383 Pa
L2HM 900 E 810 1 150 mm 576 m3/ 380 Pa
L2HM 1000 E 810 1 150 mm 576 m3/ 380 Pa
L2HM 1100 E 810 1 150 mm 576 m3/ 380 Pa
L2HM 1200 E 820 1 150 mm 655 m3/ 364 Pa
L2HM 1300 E 820 1 150 mm 655 m3/ 364 Pa
L2HM 1400 E 820 1 150 mm 655 m3/ 364 Pa
L2HM 1500 E 820 1 150 mm 655 m3/ 364 Pa
L2HM 1600 E 820 1 150 mm 655 m3/ 364 Pa
L2HM 1700 E 820 1 150 mm 655 m3/ 364 Pa
L2HM 1800 E 810 2 2 x 150 mm 1152 m3/ 380 Pa
L2HM 2000 E 810 2 2 x 150 mm 1152 m3/ 380 Pa
L2HM 2100 E 810 2 2 x 150 mm 1152 m3/ 380 Pa
L2HM 2400 E 820 2 2 x 150 mm 1310 m3/ 364 Pa
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 4/28

INSTALLER’S MANUAL
TECHNICAL DATA SHEETS, MEASUREMENTS
AND DIMENSIONS
Directives :
Low Voltage : 2006/95/CEE
CEM : 2004/108/CEE
Connecting exhaust duct :
Attention: Cut exhaust duct(s) and make sure duct, when run through the hole in the base of the installed
hood protrudes far enough to be connected to the fan(s).
Electric connection :
Finish cable with an earthed 2-pole plug suitable for 230V/1N~/50Hz.
Hood must be earthed.
Power input :
- L2HM 900 - 1100 : 120 Watt when lit.
- L2HM 1101 à 1601 : 235 Watt when lit.
- L2HM 1701 à 2002 : 240 Watt when lit.
- L2HM 2102 à 2202 : 470 Watt when lit.
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 5/28


L2HM 900 - L2HM 1000 - L2HM 1100 - L2HM 1200
L2HM 1300 - L2HM 1500 - L2HM 1600 - L2HM 1700
L2HM 1700 - L2HM 1800 - L2HM 2000 - L2HM 2100 - L2HM 2200 - L2HM 2400
INSTALLER’S MANUAL
Appliances must be installed in a workmanlike manner in accordance with the instructions in this manual
and locally applicable regulations.
This manual will be handed over to the user after installation.
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 7/28


INSTALLER’S MANUAL
SITTING
Cautions :
The purchaser undertakes to install or arrange for his/her equipment to be installed in a workmanlike manner and in
accordance with the applicable regulations and standards.
Shipment-Packaging :
Carton packing crate on wooden palette
Unpack and check the appliance is in good condition. In case of damage, note any reservations on the
delivery note and confirm them within 48 hours by registered letter with confirmation of delivery to the
carrier.
Recommendations :
- Check hood overhead clearance.
- Install elbow over hood when mounting a complete range hood connected to a wall exit.
- Do not connect exhaust duct to central ventilation system or service duct.
- Choose shortest and straightest pathway for exhaust duct.
performance loss.
- Provide and install proper damper when connecting fan exhaust to wall exit.
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 9/28

INSTALLER’S MANUAL
SITTING
LACANCHE range hoods install horizontally at a minimum distance of :
- 65 cm over electrical range.
- 80 cm over gas range.
Make sure hood is installed perfectly horizontal and cannot dip forward.
Use aluminum duct and choose shortest and straightest pathway. Do not connect to smaller diameter duct,
use no roof caps or exhaust screens.
BAD MEDIUM GOOD
Attachment plate
Front
Plastic jack x 4
Extractor hood extension
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 10/28

INSTALLER’S MANUAL
Preparing the extractor hood :
1
2 - Loosen the screws holding the front of the hood (Item A 2)
3CREW-
1
A A A A
2
INSTALLATION
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 11/28

INSTALLER’S MANUAL
INSTALLATION
3 - Stand the extractor hood upright.
3 .
3
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 12/28

INSTALLER’S MANUAL
A length of the hood - 420 mm
2356
1799
!XISOFTHEHOOD
to position if back panel
Installing hood :
4.
2 - Positioning and securing the two brackets to hood (screw-type M5).
SETTING UP THE HOOD
4
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 13/28

INSTALLER’S MANUAL
SETTING UP THE HOOD
2356
1820
Axis of the hood
Attach the trim back the hood before
NOTE: If a back cover is used, install the back cover before mounting the hood. 5
5
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 14/28

INSTALLER’S MANUAL
6 and 7.
6 - To level by tightening or loosening the 2 screws 6532570 and 6535377.
7 - End of the hood to the wall plate by tightening the screws 6535377.
6532570 6535377
SETTING UP THE HOOD
6
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 15/28

INSTALLER’S MANUAL
MANDATORYATTACHMENTS
SETTING UP THE HOOD
7
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 16/28

INSTALLER’S MANUAL
SETTING UP OF GROUPS
8 and 9:
Remove glass center intake panel .
Loosen black side cover screws .
Loosen 8 screws .
Push blower unit(s) into cutout until they bottom with rotary switch facing forward and to the right.
Make sure locking lugs hold blower unit(s) securely in place.
Tighten screws item , and .
8
9
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 17/28

INSTALLER’S MANUAL
SETTING UP OF GROUPS
Setting up in the hood 10
Remove the 4 screws on media panels and drop media panels
Media panel
Prepare the extractor unit and use the locking brackets to position it/ item B 11 and 12 (see
«assembling the unit(s)» section)
10
11 12
B
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 18/28

INSTALLER’S MANUAL
SETTING UP OF GROUPS
Fasten the extractor unit(s) to the hood by
tightening the 4 screws on either side of the
13
(see «assembling the unit(s)» section).
14
15 .
13
14
15
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 19/28

INSTALLER’S MANUAL
INSTALLING THE EXTRACTOR HOOD EXTENSION
See rating of 250 from your ceiling and adjust the media hides sheath in boutonnièress provided for this
16 .
17 ).
16
17
Hottes - Ft 118a - GB - Rév 08 - Modifié le : 06/07/2015 20/28
This manual suits for next models
12
Table of contents
Other Lacanche Ventilation Hood manuals
Popular Ventilation Hood manuals by other brands

Broan
Broan Best IEX42 owner's manual

Electrolux
Electrolux ICON RH42PC60GS Installation, use & care guide

Zephyr
Zephyr ES1-E30AB Use, care and installation guide

Airone
Airone FENICE Series Instructions for using, maintaining and installing

Broan
Broan best IS502 instructions

inventum
inventum AKB9004RGT instruction manual