ZS100 Presicion Approach Path Indicator
ZS100
1/7
Description:
Compliances: FAA L-881 Photometrics per FAA Advisory Circular 150/5345-28G
FAA AC 150/5390-2B Heliport Design Guide
Registered ISO 9001:2008
ICAO Annex 14, Volume II
HAPI is a modified PAPI system for use as visual slope guidance on heliports.
One HAPI system is for one helicopter approach path.
It is installed on the side opposite the approach, facing across the landing area.
Each HAPI system consists of two (2) HAPI units
Use Instruction:
The PAPI system is used to guide aircraft to approach the runway at an appropriate altitude.
The upper half of PAPI's beam is yellow, with green in the middle and red in the lower half. In
the visual range, different elevation lights in PAPI systems allow the aircraft to see different
colors at different altitudes. The pilot can judge and adjust the height of the plane by seeing
the color of the beam, making it at the right height. When the pilot saw the yellow ray means
to fly too high; when the pilot saw green said height at the right moment; when the pilot saw
the red light said flying too low, could hit obstacles.
Structure:
A single lamp unit consists of a lamp body and three stents. The lamp body is composed
mainly of top cover, front glass panel, box body, lens, color filter, light bulb and bracket, and
the lamp is always provided with optical element positioning and protection. The bracket
assembly consists of flanges, easy folds, long poles, screws, nuts and gaskets, which are used
to support the lamp body and control the height and elevation of the lamp body.
Installation diagram(mm)
Shanghai Lansing Electronics Co., Ltd Tel:+86 021-69172728 Fax:+86 021--69172728 ext 801 Web:www.lansinglight.com E-mail:sales@lansinglight.com Add: Building 6, No.
1028 Xinmiaosan Rd, Songjiang district Shanghai 201612
All rights reserved by Lansing, without the written authorization of the Lansing, any part thereof shall not be reproduced or transmitted in any form.
ZS100 Presicion Approach Path Indicator
ZS100
2/7
Main Parts:
1
lid
8
Lens
15
Lens mount
22
Connection
component B
2
Flat glass
9
Lens mount
16
Lens
23
Adjustable
screw
3
Lens cover
10
Light body
17
Lens cover
24
The fastening
screw
4
The tailgate
11
Filter holder
18
flange
25
Lens cover
5
The bulb
clip
12
Filter press
plate
19
Easy breaking
parts
26
clip
6
The light
bulb
13
Color filter
20
Extension rod
27
Flat glass
7
The light
bulb holder
14
Color filter
limit part
21
Connection
component A
28
The front panel
Shanghai Lansing Electronics Co., Ltd Tel:+86 021-69172728 Fax:+86 021--69172728 ext 801 Web:www.lansinglight.com E-mail:sales@lansinglight.com Add: Building 6, No.
1028 Xinmiaosan Rd, Songjiang district Shanghai 201612
All rights reserved by Lansing, without the written authorization of the Lansing, any part thereof shall not be reproduced or transmitted in any form.
ZS100 Presicion Approach Path Indicator
ZS100
3/7
Flange Mounting Dimension:
The installation of PAPI lamp unit is fixed on the precast concrete base. Anchor the flange to
the base with the anchor bolt embedded in the base. If the expansion bolts are used, the size
must be greater than M10 x 120. The fixed position is shown in the figure.
Height Setting:
According to the requirements of the base height of the optical axis of PAPI system, set a
benchmark horizontal line to meet this height requirement before the lamp body. Loosen the
connection bolt of PAPI lamp, adjust the three adjusting screw on the lamp, make the light axis
of the front part of the lamp body align with the base line. Fine-tune the screw and observe the
horizontal blisters in the lamp until the lamp body level is up.
Wiring Diagram:
The PAPI system USES 6.6A ac constant current source. If The electricity environment is 110V.
First connect 110V power transformer(or manual voltage regulator), than there is a spin
button,so you get from 0 to 6.6A constant current source as you want.(The power cable should
be protected by metal hose.)
Internal wiring:
Shanghai Lansing Electronics Co., Ltd Tel:+86 021-69172728 Fax:+86 021--69172728 ext 801 Web:www.lansinglight.com E-mail:sales@lansinglight.com Add: Building 6, No.
1028 Xinmiaosan Rd, Songjiang district Shanghai 201612
All rights reserved by Lansing, without the written authorization of the Lansing, any part thereof shall not be reproduced or transmitted in any form.
ZS100 Presicion Approach Path Indicator
ZS100
4/7
Elevation Adjustment and setting
There is a spin button at the top of manual voltage regulator,which a adjustable point (a white
core) to adjust the current that you need.Please reference the following picture.
For the Input site,there are little red spin button and black spin button,marked “ A” and
“X”.For the “A” button,please connect with the Live wire,and for the “X” button,please
connect with Null wire.For Output site,please connect with PAPI light.
Shanghai Lansing Electronics Co., Ltd Tel:+86 021-69172728 Fax:+86 021--69172728 ext 801 Web:www.lansinglight.com E-mail:sales@lansinglight.com Add: Building 6, No.
1028 Xinmiaosan Rd, Songjiang district Shanghai 201612
All rights reserved by Lansing, without the written authorization of the Lansing, any part thereof shall not be reproduced or transmitted in any form.
ZS100 Presicion Approach Path Indicator
ZS100
5/7
Please make sure the lamps is power off before replacing light bulbs
Replacement of bulb method: pinch the bulb at the end of the bulb, pull up the bulb, and
then pull the plug out. When installing a new light bulb, connect the plug connector first,
then the bulb will be pressed down until the bulb is in place. As shown below:
Replacement of color filter method:
Loosen two M4 tightening screws on the filter press and remove the clamp and screws,
Then take out the old filter and replace it with a new filter. Press the light bulb until it
comes in contact with this Remove the filter and press plate
Shanghai Lansing Electronics Co., Ltd Tel:+86 021-69172728 Fax:+86 021--69172728 ext 801 Web:www.lansinglight.com E-mail:sales@lansinglight.com Add: Building 6, No.
1028 Xinmiaosan Rd, Songjiang district Shanghai 201612
All rights reserved by Lansing, without the written authorization of the Lansing, any part thereof shall not be reproduced or transmitted in any form.
ZS100 Presicion Approach Path Indicator
ZS100
6/7
Schematic diagram for Changing the color filter
Consideration
Be careful when handling; Landing or collision will cause damage to the inner light bulb or
other optical parts of the product, and may result in scratches.
wet hand to touch the internal electrical equipment shall be strictly prohibited
environmental temperature -40 ° C ~ + 55 ° C;
Caution
1All the connections must be correct, otherwise it will damage the lights, please check the
mark and instruction carefully.
2The power supply is AC110 50HZ/60HZ, can’t use other powers, otherwise it will damage
the lights.
3The obstruction light need to be installed below lightning conductor or lightning protection
zone, in case light be struck by lightning.
4It’s normal if temperature rise while operating.
5Please do not open any part of lights while operating.
6The light is fully sealed, please do not install or dismantle unless you are professional. Once
operated inappropriately, our company will not guarantee the warranty.
Shanghai Lansing Electronics Co., Ltd Tel:+86 021-69172728 Fax:+86 021--69172728 ext 801 Web:www.lansinglight.com E-mail:sales@lansinglight.com Add: Building 6, No.
1028 Xinmiaosan Rd, Songjiang district Shanghai 201612
All rights reserved by Lansing, without the written authorization of the Lansing, any part thereof shall not be reproduced or transmitted in any form.
ZS100 Presicion Approach Path Indicator
ZS100
7/7
Quality assurance and responsiblity:
This product from normal use but no more than a year after installation within 12 months of shelf
life, or in the warranty period stipulated in the tender and bid, any defects in design, material or
process, the manufacturer will be responsible for free replacement. But manufacturer does not
assume the use of the light bulb attrition is damaged, and because of the unqualified installation,
maintenance method is not correct, improper operation, power supply system fault, watchung
caused by wrong operation and so on damage compensation. The compensation of the
manufacturer is limited to the precise approach to the channel indicator itself and does not
involve any other loss of the user.

Popular Measuring Instrument manuals by other brands

Fluke RUSKA 2482 user manual

Fluke

Fluke RUSKA 2482 user manual

Hesai Pandar128 user manual

Hesai

Hesai Pandar128 user manual

FlowLine LI25 Series instruction manual

FlowLine

FlowLine LI25 Series instruction manual

AstroAI GL-0801A user manual

AstroAI

AstroAI GL-0801A user manual

Triplett SoniChek PRO 3550 instruction manual

Triplett

Triplett SoniChek PRO 3550 instruction manual

Fluke 771 Calibration manual

Fluke

Fluke 771 Calibration manual

VXI VM2601 user manual

VXI

VXI VM2601 user manual

wtw pH 340/ION Instruction manuals

wtw

wtw pH 340/ION Instruction manuals

Fluke 772 instruction sheet

Fluke

Fluke 772 instruction sheet

General DT4208SD user manual

General

General DT4208SD user manual

Pfeiffer Vacuum PPT 200 operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum PPT 200 operating instructions

Omnitronic an-31 xl user manual

Omnitronic

Omnitronic an-31 xl user manual

IDS IDS-iSYS user manual

IDS

IDS IDS-iSYS user manual

Siemens SITRANS P300 quick start guide

Siemens

Siemens SITRANS P300 quick start guide

Hanna Instruments HI 718 quick start guide

Hanna Instruments

Hanna Instruments HI 718 quick start guide

AUDIOropa PROLOOP FSMplus Operation instructions

AUDIOropa

AUDIOropa PROLOOP FSMplus Operation instructions

Riken Keiki GX-8000 operating manual

Riken Keiki

Riken Keiki GX-8000 operating manual

VOLTCRAFT VC-585 operating instructions

VOLTCRAFT

VOLTCRAFT VC-585 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.