30W LED Fixture for Hazardous Location Lighting
120-240V - C1D2 - 3900 Lumens - Magnet Mount
Instruction Manual
•INSTALLATION SHOULD ONLY BECONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY
RELEVANT LOCAL BUILDING CODES.
•RISK OFFIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF FIXTURE'S ELECTRICAL
SYSTEMS. IFNOTQUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.
•BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
•MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE FIXTURE'S RATED VOLTAGE.
•TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP
OBJECTS. SUITABLE FOR DAMP LOCATIONS.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE. THE HAL-36-25W-LED-JB-1227-M MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL
CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.
WE STRONGLY ENCOURAGE ONLY ALICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS
PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET, CONSULT
AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE.
WARNING: MAKE SURE POWER ISTURNED OFF BEFORE STARTING THE INSTALLATION OR
PERFORMING ANY MAINTENANCE.
RISK OF FIRE/ELECTRIC SHOCK –DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING. RISK
OF PERSONAL INJURY –FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOTINSTALLED PROPERLY. RISK OF
BURN –ALLOW FIXTURE TO COOL BEFORE SERVICING.
Thank you for your purchase of the Larson Electronics HAL-36-25W-LED-JB-1227-M.
WARNING:
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CRITICAL SAFETY INSTRUCTIONS:
WARNING:
USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE. THIS LINE
CORD IS INTENDED TO ALLOW OPERATORS TO EXTEND POWER TO EQUIPMENT WHEN STATIONARY OUTLETS ARE NOT
READILY AVAILABLE.
IMPROPER USE OF THIS CORD, PLUG, AND RECEPTACLE CAN LEAD TO SERIOUS INJURIES OR DEATH TO
PERSONNEL.
PERIODIC INSPECTION OF THE CORD IS NECESSARY.
THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY ARE FOUND,
THE CORD MUST BE REPLACED BEFORE RESUMING USE.

HAL-36-25W-LED-JB-1227-M
Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 2of 4
WARNING
TO AVOIDTHE RISKOF FIRE,EXPLOSION OR ELECTRIC SHOCK, THIS PRODUCT SHOULD BE INSTALLED,
INSPECTEDAND MAINTAINEDBY A QUALIFIED ELECTRICIANONLY, IN ACCORDANCEWITHALL
APPLICABLEELECTRICAL CODES.
TO AVOIDELECTRIC SHOCK:
•BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
•PRODUCT MUST BE CONNECTED TO A WIRING SYSTEM WITH AN EQUIPMENT-GROUNDING
CONDUCTOR.
TO AVOID EXPLOSION:
•MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING.
•ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS
ATMOSPHERE.
•DO NOT OPERATE IN AMBIENT TEMPERATURES ABOVE THOSE INDICATED ON THE PRODUCT
NAMEPLATE.
•DO NOT OPERATE IF THE LENS, CORD, SEALS, HOUSING, RECEPTACLES, ETC. IS CRACKED OR
DAMAGED. IF SO, DISCONTINUE USE AND CONTACT MANUFACTURER FOR REPLACEMENT PARTS.
•ALL FASTENERS SHOULD BE PROPERLY SEATED.
WARNING:
USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE. WHEN EXTENSION
CORD IS CONNECTED TO A POWER SOURCE IN HAZARDOUS AREA, PLUG AND MATCHING RECEPTACLE
MUST BE SUITABLE FOR HAZARDOUS LOCATION INVOLVED. IMPROPER USE OF THIS DEVICE, ASSOCIATED
PLUG, RECEPTACLE, AND CORD CAN LEAD TO SERIOUS INJURIES OR DEATH TO PERSONNEL.
PERIODIC INSPECTION OF THE RECEPTACLE AND CORD IS NECESSARY.
THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY
ARE FOUND, THE CORD MUST BE REPLACED BEFORE RESUMING USE OF THE UNIT.
ELECTRICAL POWER SUPPLY MUST BE “OFF” BEFORE AND DURING INSTALLATION AND MAINTENANCE.
INSTALLATION AND MAINTENANCE PROCEDURE MUST BE PERFORMED BY A TRAINED AND COMPETENT
ELECTRICIAN.
IF ANY PARTS OF THE RECEPTACLE OR PLUG APPEAR TO BE MISSING, BROKEN, OR SHOW SIGNS OR
DAMAGE, DISCONTINUE USE IMMEDIATELY. REPLACE WITH THE PROPER REPLACEMENT PART(S) BEFORE
CONTINUING SERVICE.
Magnetic Warning
•PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN(S) BEFORE USE.
ELECTROMAGNETIC FIELDS INCLOSE PROXIMITY TOHEART PACEMAKER COULD CAUSE
PACEMAKER INTERFERENCE OR PACEMAKER FAILURE.
•KEEP FINGERS AWAY FROM MAGNET WHEN MOUNTING ASINJURY COULD OCCUR.
The HAL-36-25W-LED-JB-1227-M from Larson Electronics is a High Voltage Hazardous Location Magnetic Mount
Lighting Solution that is approved for Class I Division 2 environments and UL 1598 compliant for use in wet locations.
This powerful 35.88" long LED strip light produces 3,900 lumens, operates from 120 to 240V AC, and is suitable for a
variety of applications.
WIRING
These hazardous location LED lights are equipped with 5 feet of cord containing an explosion proof 5-15 plug rated at 15
amps. These lights operate from 120-240 volt AC current at 25 watts drawing 0.21 amps on 120 VAC and 0.11 amps on
240 VAC.
Standard pigtail(flying leads) wiring
We strongly encourage a licensed electrician install this product,in all locations especially in outdoor areas
where weatherproofing may be required. Universal voltage driver permits operation at 120V - 240V AC, 50 or 60Hz.

HAL-36-25W-LED-JB-1227-M
Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 3of 4
Warning: Check product label for correct input voltage!
Attach supply line wires to the appropriate light fixture wires as shown
in thediagram
Secure each pair of wires according to the diagram. Utilize a junction box or
similar device and take precautionary steps for weatherproofing all
connections if installed in a location where water may come in contact with the
unit. Ensure the unit is properly grounded and that wiring is done according to
all local and national electrical/building codes.
Exp Cord Cap
Position device near work area for operation. Run cable to nearby power
source. Insert and twist-lock explosion-proof plug into a compatible receptacle within
the hazardous environment. See plug operation below.
PLUG OPERATION
Electrical connection between plug and compatible receptacle is accomplished
after plug fully inserts into receptacle and rotated clockwise.
1. Lift receptacle door and locate polarization on mating plug pin and
receptacle face. Insert plug straight all the way into receptacle until it
cannot go further.
2. Rotate plug clockwise limit (37º), this closes internal contacts and
completes circuit. This also mechanically locks plug into receptacle so it
cannot be pulled out.
3. To remove plug, push plug inward and turn to counterclockwise, pull plug
straight out.
MOUNTING
The HAL-36-25W-LED-JB-1227-M is equipped with two 200 lb magnets spaced evenly along the length of the light. The
magnets allow for quick and secure mounting on flat, magnetic surfaces. The entire assembly weighs 2.5 lbs and measures
35.88 inches in length, and 2.68 inches wide and 1.69 inches deep, making it ideal for mounting in areas where space is
limited and a low profile fixture more readily installed.
VERSATILITY
The HAL-36-25W-LED-JB-1227-M is ETL approved for Class I Division 2 groups A, B, C and D locations. This unit carries
an IP54 water resistant rating ensuring protection against limited ingress from dusts, dirt, and basic protection against light
water spray landing directly on the fixture. This light is ideal for indoor or outdoor applications and industrial operations with
hazardous location classification where dusty or wet conditions are commonly encountered.
MAINTENANCE
Caution: To avoidpersonal injury, disconnect power to the light and allow the unit to cool downbeforeperforming
maintenance.
Warning:No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will voidthe warranty.
1. Perform visual,mechanical and electrical inspections on a regular basis.We recommend routine checks to be
made on a yearly basis. Frequency of use and environment shoulddetermine this. It is recommendedto follow
an Electrical Preventive Maintenance Program as described in NFPA 70B: Recommendedpractice for
Electrical Equipment.
2. The lens should be cleaned periodically as neededto ensure continued photometric performance. Clean the
lens with a damp, non-abrasive,lint-free cloth. If not sufficient, use mild soapor a liquid cleaner.
3. Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or contamination (i.e.
excessivedust build-up). Clean with a non-abrasive clothif needed.
4. Do not operate if the lens is cracked or damaged. All fasteners shouldbe properly seated.

HAL-36-25W-LED-JB-1227-M
Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 4of 4
USE AND CARE
Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment.
Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of
children when not in use.Inspect for good working condition prior to storage and before re-use.
REPLACEMENT PARTS
The HAL-36-25W-LED-JB-1227-M is designed to provide years of reliable performance. Should the need for
replacement parts arise, please contact Larson Electronics.
THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS.
SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT
SALES@LARSONELECTRONICS.COM OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE.
PLEASE VISIT LARSONELECTRONICS.COM FOR WARRANTY AND RETURN INFORMATION.
Table of contents
Other Larson Electronics Rack & Stand manuals

Larson Electronics
Larson Electronics TPM-LEDLB-32E User manual

Larson Electronics
Larson Electronics ALU-TP-W-58 User manual

Larson Electronics
Larson Electronics EPF-LPSM Series User manual

Larson Electronics
Larson Electronics GLS-PMK User manual

Larson Electronics
Larson Electronics ALU-TP-58-PHRT User manual

Larson Electronics
Larson Electronics PTB-1-WHT User manual
Popular Rack & Stand manuals by other brands

Next Level Racing
Next Level Racing GT Lite instruction manual

Wayfair
Wayfair Durand 103.5 Cm Rolling Clothes Racks manual

Unicol
Unicol WB0 instructions

Catalyst
Catalyst 63607147 Instruction booklet

SportRack
SportRack SR2901B manual

System Sensor
System Sensor SMB600 Installation and maintenance instructions