Lasermet I-EXTRACT User manual

I-Extract Instruction Manual
CEB00XXX-53-000 Issue 2 30 January 2020
LASERMET
I-EXTRACT
INSTRUCTION MANUAL
FUME EXTRACTION SYSTEM
Issue 2

I-Extract Instruction Manual
CEB00XXX-53-000 Page 2 of 11 Issue 2 30 January 2020
LASERMET I-EXTRACT
Instruction Manual
Contents
1 Safety Warnings .................................................................................................................. 3
2 Concept ............................................................................................................................... 4
3 Assembly ............................................................................................................................. 5
4 Filter .................................................................................................................................... 6
4.1 Replacement Schedule ................................................................................................ 6
4.2 Filter Change ............................................................................................................... 6
4.3 Pre-Filter Change ......................................................................................................... 7
4.4 HEPA Filter Change ...................................................................................................... 8
5 Specifications ...................................................................................................................... 9
6 Warranty ........................................................................................................................... 10
7 Contact Details .................................................................................................................. 11

I-Extract Instruction Manual
CEB00XXX-53-000 Page 3 of 11 Issue 2 30 January 2020
1 Safety Warnings
This device is intended to be used as part of a safety system which may be used to protect personnel
and equipment from possible injury, damage, or loss.
As such it must be installed and wired according to these instructions and tested by suitably qualified
persons. No attempt may be made to tamper with the parts, open them, or use them outside of the
parameters contained herein.
The units are only designed to be fixed to surfaces using their inbuilt fixing holes. They must not
come into contact with each other or any other moving part when in use. The parts should never be
subject to impact or mechanical strain.
Safety switches should never be defeated or bypassed. It is imperative that all steps are taken to
ensure that any spare actuators are made unavailable, such that they cannot be used to defeat the
switch or reduce the protection offered by the system in any way.

I-Extract Instruction Manual
CEB00XXX-53-000 Page 4 of 11 Issue 2 30 January 2020
2 Concept
I-Extract is Lasermet’s fume extraction system specifically designed for the extraction and filtration
of gases and emissions created by lasers during laser welding, laser cutting and laser cladding
processes.
Designed as an integrated part of Lasermet’s “Laser Castle” laser safety cabin, the I-Extract has
ample power to extract the appropriate volume of emitted gases produced in the cabin.
The specific CFM (cubic feet per minute) figures are available for specific cabins.
A powerful, three phase electric motor powers the extraction fan.
The overall enclosure is manufactured using galvanised sheet metal with a powder coated finish.
Lasermet provides a full range of laser interlock equipment including control systems, interlock
switches, illuminated warning signs, laser shutters, door locks, external power supplies etc. which
can be connected to provide a complete laser interlock system. Full support, design and installation
is available from Lasermet, please contact us for any queries. Contact details are given at the end of
this manual.
Filters
One HEPA Filter (High-efficiency
particulate arrestance) individually
tested to EN1822:2009 H3, and two
further filters tested to EN779:2012
Filter Class M6.
Approvals
I-Extract
High Efficiency Laser Fume Extraction System
– complete unit

I-Extract Instruction Manual
CEB00XXX-53-000 Page 5 of 11 Issue 2 30 January 2020
3 Assembly
1) Lift, position and secure filter section
2) Lift, position and secure fan assembly and silencer. Use mastic sealer between flanges.

I-Extract Instruction Manual
CEB00XXX-53-000 Page 6 of 11 Issue 2 30 January 2020
4 Filter
The Lasermet filter assembly has two-stage filtration.
1) EN779 Class M6 Pre-Filter 50mm deep
Ordering information Lasermet Part Number LMFP-50
2) EN1822 Class H13 HEPA Filter Cell 292mm deep
Ordering information Lasermet Part Number LMFH-292
4.1 Replacement Schedule
It is recommended that the differential pressure is monitored across each filter stage and the filters
replaced when the first of the following occurs:
1) The M6 reaches final pressure drop 250Pa. The H13 reaches final pressure drop 600Pa
2) Each filter reaches 2.5 times its initial pressure drop.
3) The pre-filter has been installed for 1 year, the final filter 3 years.
4.2 Filter Change
To remove the filter cells, it is necessary to remove the filter access doors. These are secured by
hand knobs so no tools should be required to remove them.
It is recommended the person carrying out the filter change wears appropriate protective
equipment e.g. overalls, dust mask, gloves.
Note: The fan should be isolated from power while the filter change is carried out.

I-Extract Instruction Manual
CEB00XXX-53-000 Page 7 of 11 Issue 2 30 January 2020
4.3 Pre-Filter Change
1) Remove lower access door.
2) Pull out the old filter from the filter slide section and dispose of according to local
regulations.
3) Check brush seal is in good condition and does not need replacing/reapplying.
4) Refit access door and tighten hand knobs until tight. Check door seal is good.

I-Extract Instruction Manual
CEB00XXX-53-000 Page 8 of 11 Issue 2 30 January 2020
4.4 HEPA Filter Change
1) Remove upper access door.
2) Release the filter by dropping the lever arms of
the clamps as shown.
3) Pull out the old filter from the filter section and
dispose of according to local regulations.
4) Insert new filter taking care to respect any airflow
indication arrow. The filter seal should face
upwards to seal against the filter housing sealing
face.
5) Clamp the new filter by pulling the lever arm of
the cambars into the vertical position.
6) Refit access door and tighten hand knobs until
tight.
7) Check door seal is good.

I-Extract Instruction Manual
CEB00XXX-53-000 Page 9 of 11 Issue 2 30 January 2020
5 Specifications
Duty 1200m³/hr or 706CFM @ 2788Pa (max)
Fan Type CF1 Fan
Fan Motor (UK/EU) 1.1kW 400V / 3ph / 50Hz
2885RPM direct drive motor
Duty 1200m³/hr or 706CFM @ 2940Pa (max)
Fan Motor (US) 2.2kW 460V / 3ph / 60Hz
3443RPM direct drive motor
Housing
Frame Galvanised sheet metal
Finish Powder coated
Gasket EPDM, continuous Ø15mm
Filtration
System comprises 1xH13 (16m²) + 2xM6 (2.9m² Filters)
Test Standard:H13 Individually tested to EN1822:2009
Type HEPA Filter (High-efficiency particulate arrestance)
Media Glass fibre
Separator Hot-melt beads
Sealant Polyurethane (2k sealant)
Filter Class according to EN1822:2009: H13
MPPS Efficiency H13:>99.95%, H14:> 99.995%.
Maximum Pressure Drop 600Pa
Nominal Drop 250Pa
Temperature / Humidity 70°C / 100% RH
Dimensions
Size 289W x 595H x 292D mm
Area 0.16m²
Air Flow 1300m³/min
Volume 0.06m³
Filter Weight 8.5kg
High-efficiency Compact Filter x 2 (M6)
Frame Water resistant cardboard
Media Wet-laid glass fibre paper
Separator Hot melt adhesive
Sealant Polyurethane
Filter Class EN779:2012 Filter Class M6
Temperature 70°C
Humidity 100% RH
Size 592W x 592H x 96D mm
Area 9.3m²
Air Flow 2900m³/min
Volume 0.04m³
Weight 4kg
Pressure Drop 70Pa
Recommended Final Pressure Drop 350 Pa
Economical Change Point 250 Pa

I-Extract Instruction Manual
CEB00XXX-53-000 Page 10 of 11 Issue 2 30 January 2020
Dimensions
Dimensions are approximate. Values given as ‘typical’ are average values measured across a number
of samples and are not guaranteed. Lasermet reserve the right to alter any specification without
prior notice.
6 Warranty
Lasermet provide a 12-month warranty for defects in materials and manufacture, from the date of
installation or delivery. Installations completed by Lasermet are covered against defects in
workmanship for 12 months.
All filters in the fume extraction system must be replaced with Lasermet filters in accordance with
the specification in this manual.
Damage or defects caused by other factors are not covered. For example, industrial contamination,
incorrect cleaning, storm damage. Consequential loss is not covered under warranty. Compensation
for indirect or direct loss or damage is expressly excluded. Rectification of the defects or a
replacement does not initiate a new warranty period.
For all deliveries, payments and other legal transactions, English law takes precedence for any
litigation.

I-Extract Instruction Manual
CEB00XXX-53-000 Page 11 of 11 Issue 2 30 January 2020
7 Contact Details
Lasermet provide a full range of laser interlock equipment including interlock switches, illuminated
warning signs, laser shutters, entry keypads with built-in fail-safe override timer, door locks, external
power supplies etc. which can be interconnected to provide a complete system. We also supply
equipment and consultancy covering all aspects of laser safety. Full support, design, and installation
is available from Lasermet, please contact us for any queries.
For sales and technical support:
Lasermet Ltd.
Lasermet House,
137 Hankinson Road,
Bournemouth
BH9 1HR
United Kingdom.
Tel: +44 (0) 1202 770740
Fax: +44 (0) 1202 770730
Website: www.lasermet.com
Lasermet Inc.
10N Martingale Road, Suite 400,
Schaumburg, Illinois 60173
United States.
Tel: 847 466 1475
Website: www.lasermet.com
Table of contents