LCN LCN-GTS6 User manual

1
Sensor-keypad with
The LCN-GT6 (LCN-GTS6) is a 6-key sensor-keypad for the T-Port.
The integrated temperature sensor can be used on
(Juni 2013) or after.
The sensor keys are each equipped with an additional status-LED and a blue background
light.
®
A corona - surrounding light with white LED´s, serves as
a decorative wall light (LCN-NUI required) and can be
switched as a decent orentation light, so that the LCN-
GT6 (LCN-GTS6) can also be operated in darkness.
The 6 capacitive working sensor keys are situated
behind a 5mm thick glass front. A soft touch to the
surface is enough to trigger off the functions. The
captions on the sensor keys can be carried out individual-
ly per inlay and can be changed anytime without difficulty.
6 keys and temperature sensor
LCN modules with 1706.. firmware
LCN-GTS6
®
Installation guide
LCN-GT6
®
A1
L1 A2 L2
A3
L3 A4 L4
A5
L5 A6 L6

2
Scope of delivery
LCN-GT6 (LCN-GTS6), mounting plate, 2 screws 3,2 x 15mm & inlay sheet (blank).
How it functions
The sensor keys of the LCN-GT6 (LCN-GTS6) react to a touch on the glass surface.
Depending on the duration of touch, an appropriate LCN-control command (Hit, LONG or
RELEASE) will be sent. When no changes are made to the default key settings, (see page 5:
Key mapping), the keys work on the A table according to their numbering.
There is the possibility to trigger off 2 additional keys, through touching two keys at
the same time. Key A1+A6=D7 and A2+A5=D8.
This kind of double touching is especially suitable for functions, that should not be
accidentally triggered. (central-off, switching the alarm system, etc)
The integrated temperature sensor supplies the measured values with a triggering from
0,1°C, and thanks to its adaptive average calculation, practically noiseless.
The 6 Status-LED´s in the sensor areas are individually controlled over the T-Port and
configured over the LCN-PRO (ON, OFF, BLINKING, FLICKERING).
An external power supply is needed when operating the key background LED´s and the
®
Corona -surrounding light (please order LCN-NUI seperately). The application of a
power supply is also meaningful with a brighter environment; It increases the brightness of
all the LED´s on the LCN-GT6 ( LCN-GTS6 ).
LCN-GTS6
®
Installation guide
LCN-GT6
®

3
The ,
background LED´s are controlled over the LED-command “GT-Brightness”. The bright-
®
ness of the corona -surrounding light and the O-Light is in several steps and the blue key-
background LED´s can be switched ON/OFF.
Installation
(An LCN-UPP with a high (dim-) load would falsify the measured value! )
Apart from that, the LCN-GT6 should not be installed near lights
. In this case it is
better to install an additional LCN-GRT !
The LCN-GT6 must not “wobble” on the wall, as this would
lead to false triggering. That is why when installing, the edges of the
cavity wall mounted box should be counter-sunk, or the flush mounted
box should not be surmounted on the wall, to guarantee a flawless
function of the LCN-GT6 (LCN-GTS6).
®
Corona -surrounding light O-Light (Orientation light) and the blue key-
Note:
Important:
When the temperature sensor is in use, no heat sources should be in the flushed
mounted box!
, other heat sources,
cooling devices, as these factors would falsify the temperature values
C
D
LCN-GTS6
®
Installation guide
LCN-GT6
®

5
A3
A1
A4
A2
A5 A6
A1
A2 A3
A2A1
Getting into operation
Requirements: LCN Bus module with firmware 1706.. (June 2013) or
after, if you do not use the integrated temperature sensor, even with
120C05 (December 2010) or after.
Settings: The
Key assigment (Key-Mapping):
According to customers wishes, larger keys can be assigned in the LCN-
PRO menu Ports . The assignments can
be comfortably chosen as graphics.
For example each line of 3 keys can be changed into 2 larger keys, see
the lower example. Important functions can be easily operated, without
losing the flexibility of many keys.
/T-Ports/Change mapping
LCN-GT6 (LCN-GTS6) will be automatically recognized
from the module and the temperature registered in the variable 3 - you
can check the value in the analogue status window of the LCN-PRO.
LCN-GTS6
®
Installation guide
LCN-GT6
®

4
1. Insert guiding pins at an
angle from the bottom
2. engage to the bottom
corners in a slanted
movement
3. press the LCN-GT6 towards
the wall, lock slides on the side
When installing, firstly join the T-port cable to the connected UP(x) module
onto the wall.
At the bottom area, the LCN-GT6 must be hooked into the corners of the
mounting frame and pressed towards the wall. Through pushing in the
plastic slider on the side, the LCN-GT6 is locked firmly onto the mounting
frame.
LCN-GT6 (LCN-GTS6) Installation:
LCN-GTS6
®
Installation guide
LCN-GT6
®
IG1
LCN
ISSENDORFF
Oben
adjusting the
mounting frame
green:
help for insertion
and then screw

6
Inscription
You will find the inscription software GT-Designer on our
homepage LCN.de in the download area, for creating captions
on your GT-inlays. The inlay must be cut to 61mm * 75mm.
Standard 80g printing paper is appropriate and easy to handle.
Semi-transparent paper/plastic sheet is even better for ideal
luminance of the status LED´s
Inserting the inlay into the key-sensor
Pull the plastic slide to the side (outwards) at the rear of the
key-sensor. Insert the inscripted inlay at the bottom side of the
LCN-GT6 (LCN-GTS6) into the groove until it resists.
Tip: If you cut off the corners of the inlay around 2 mm, it will
make it easier for inserting the inlay into the groove. When
changing the paper, remove the LCN-GT6 (LCN-GTS6) from
the wall.
LCN-GTS6
®
Installation guide
LCN-GT6
®
locked!
unlocked!

7
Brightness / power supply LCN-NUI
The application of a power supply LCN-NUI is required
®
when the blue background light and/or the Corona
surrounding lights are being used. Apart from that, the
red status LED´s will light up brighter, that is important
with direct sunlight or when a reading precision is desired
from a long distance.
The power supply LCN-NUI is connected to the I-Port of
any module with year of manufacture 2013 or later, and
supplies the T-Port over the module.
The brightness of the status-LED´s, as well as the
®
Corona surrounding-light, can be reduced for the night
operation with the command LED control/LED
brightness.
Captions for the keys using ordinary paper and operation
without an LCN-NUI, make the LED´s harder to
recognise by direct exposure to light. In this case use
plastic sheets or an LCN-NUI.
LCN-GTS6
®
Installation guide
LCN-GT6
®
optional
A1
L1
A2
L2
A3
L3
A4
L4
A5
L5
A6
L6
LED`s for
®
Corona -Light
LED for O-Light

ISSENDORFF KG, D-31157 Sarstedt
LCN-GT6 GB 05/2015
8
Technical information and images are non binding. Changes are reserved.
Technical hotline: +49 5066 998844 or www.LCN.de
Technical data
Connection
power supply
LCN-connection: sliding contacts to connect to the mounting frame
Function
keys: 6 capacitive sensor areas behind 5mm glass with
the functions Hit / LONG / BREAK
LED´s: 6 LED´s for displaying LCN status messages
functions: OFF / BLINKS / FLICKERS / ON, 2 brightnesses
key background LED´s (blue), funktions: OFF / ON
®
white corona -LED´s controllable over
command ”GT brightness”, adjustable in steps
temperature sensor: measurement range
Installation
dimensions (W x H x D): 90mm x 90mm x 12,5mm (5mm glass thickness ® LCN-GT6)
75mm x 75mm x 10,5mm (3mm glass thickness ® LCN-GTS6)
operating temperature: -10°C to +50°C
air humidity: max. 80% rel., non condensing
environmental conditions: use as stationary installation according to VDE632, VDE637
protection art: IP 20
installation: installation over a flush mounted box
: over the T-Port (optionally with LCN-NUI)
-10°C to +50°C, triggering 0,1°C
accuracy type 0,3°C from +15°C to +30°C
LCN-GTS6
®
Installation guide
LCN-GT6
®