manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LDT
  6. •
  7. Recording Equipment
  8. •
  9. LDT HSI-88-G User manual

LDT HSI-88-G User manual

L
ittfinski
D
aten
T
echnik
(LDT)
Operating Instruction
High Speed Interface
HSI-88 for the s88-
feedback bus
from the Digital-Professional-Series !
HSI-88-G
Part-No.:
030313
>> finished module in a case <<
⇒
Extremely fast (9600-baud) galvanic separated
connection through the serial port (RS232) of the
Personal Computer (PC).
⇒
3 feedback lines triple the reading speed of the s88
feedback bus.
⇒
3 feedback lines will also ease the grouping and
installation of the feedback modules below your
model railway panel.
This product is not a toy! Not suitable for children under 14 years of age! The kit
contains small parts, which should be kept away from children under 3! Improper
use will imply danger or injuring due to sharp edges and tips! Please store this
instruction carefully.
CE Part-No.:
24 02 66
Introduction / Safety Information:
You have purchased the High Speed Interface HSI-88 for the s88
feedback bus. The HSI-88 is a high quality product, which is
supplied within the
Digital-Professional-Series
of Littfinski
DatenTechnik (LDT).
We wish you having a good time using this product.
•Please read the following instructions carefully. Warranty will
expire due to damages caused by disregarding the operating
instructions. LDT will also not be liable for any consequential
damages caused by improper use or installation.
The finished modules in a case come with 24 month warranty.
Connecting the Interface to your digital
control center and Personal Computer
(PC):
•Attention: Please switch off your model railway by
disconnecting the transformers from AC-current, and
switch off your PC before starting the installation of the
unit.
Voltage (14 to 18V AC from any model railroad transformer) will
be supplied via clamp KL1 to the interface HSI-88.
If you use the HSI-88 on a 3L system (Märklin tracks with center
conductor) you can use feedback modules which switch to
ground connection.
In this case please pay special attention to the correct
connection of the supply cables “brown” (system ground)
and “yellow”.
The input of clamp KL1 is marked accordingly.
If your model railway software supports the HSI-88 you need a
second free serial port on your PC. This port will be mostly
indicated as COM-Port.
Use the supplied computer cable to connect the Interface HSI-
88 via the free serial port with your PC.
KL1
s88 Rückmeldebus
s88 feedback bus
LEFTMIDDLERIGHT
High Speed Interface 88
HSI-88
Rev. 2.1
Littfinski DatenTechnik
br. gelb
14..18V~
Computer
RS232
Schnelles Computer-Interface für den s88-Rück-
meldebus. Ermöglicht 3 Rückmeldestr nge.
High Speed Interface-88
HSI-88
Digital-Profi werden!
Littfinski DatenTechnik (LDT)
www.ldt-infocenter.com
At last connect the s88-feedback modules to the HSI-88 Interface
by using the three 6-pole pin plugs marked LEFT, MIDDLE and
RIGHT.
With the HSI-88 you can build up 3 feedback lines. This will give
the advantage of speeding up the reading of the feedback
modules by three times.
Another advantage is the simple arrangement and installation of
your feedback modules below your model railway track panel.
Start always with connecting the first line on the input marked
as LEFT of the HSI-88. If you want to build a second line connect
it to the input marked as MIDDLE. A third line must be connected
to the input marked as RIGHT accordingly.
Even if you use only some few feedback modules on your model
railway track it is recommended to distribute the feedback
modules to all three inputs (LEFT, MIDDLE, and RIGHT) of the
HSI-88 evenly.
As a result, the feedback-information will be much faster
detected by the HSI-88 and transferred to the PC.
KL1
R1
R7
R8
R11
R3
R9
R10
R6
R4
C8
D3
C3
C4
D2
CD4503
IC3
R2
R5
D1
+
C10
L1
C9
Q1
LM2574
IC2
C1
C5
R12
C2
1 5
96
BL09
BU1
89C52
IC1
LTV847
IC5
CD4503
IC4
Rev. 2.1
gelbbr.
s88 Rueckmeldebus
s88 feedback bus
RS232
Littfinski DatenTechnik
High Speed Interface 88
Computer
HSI-88
14..18V~
RIGHT MIDDLE LEFT
L1 M1 R1
L2 M2 R2
L-Max M-Max R-Max
Adapter:
Adap-HSI-s88-N
braun
brown
gelb
yellow
Vom Modellbahntrafo
From transformer
IN
10
9
11
8
7
6
5
4
3
2
1
12
13
14
15
16
KL6KL5KL4KL3KL2KL1
LittfinskiDatenTechnik(LDT)
ST2ST1
Rückmeldemodul RM-88-N
16- channel feedback module
Rev.1.0
BU1 BU2
s88-N
OUT IN
s88-N
OUT
16 Rückmeldeeing nge für den
s88-Rückmeldebus.
Rückmeldemodul
RM-88-N
s88-N
Digital-Profiwerden!
Littfinski DatenTechnik (LDT)
www.ldt-infocenter.com
IN
10
9
11
8
7
6
5
4
3
2
1
12
13
14
15
16
KL6KL5KL4KL3KL2KL1
LittfinskiDatenTechnik(LDT)
ST2ST1
Rückmeldemodul RM-88-N
16- channel feedback module
Rev.1.0
BU1 BU2
s88-N
OUT IN
s88-N
OUT
16 Rückmeldeeing nge für den
s88-Rückmeldebus.
Rückmeldemodul
RM-88-N
s88-N
Digital-Profiwerden!
Littfinski DatenTechnik (LDT)
www.ldt-infocenter.com
IN
10
9
11
8
7
6
5
4
3
2
1
12
13
14
15
16
KL6KL5KL4KL3KL2KL1
LittfinskiDatenTechnik(LDT)
ST2ST1
Rückmeldemodul RM-88-N
16- channel feedback module
Rev.1.0
BU1 BU2
s88-N
OUT IN
s88-N
OUT
16 Rückmeldeeing nge für den
s88-Rückmeldebus.
Rückmeldemodul
RM-88-N
s88-N
Digital-Profiwerden!
Littfinski DatenTechnik (LDT)
www.ldt-infocenter.com
IN
10
9
11
8
7
6
5
4
3
2
1
12
13
14
15
16
KL6KL5KL4KL3KL2KL1
LittfinskiDatenTechnik(LDT)
ST2ST1
RückmeldemodulR M-88-N
16- c hannel feedback module
Rev.1.0
BU1 BU2
s88-N
OUT IN
s88-N
OUT
16 Rückmeldeeing n ge für den
s88-Rückmeldebus.
Rückmeldemodul
RM-88-N
s88-N
Digital-Profiwerden!
LittfinskiDatenTechnik(LDT)
www.ldt-infocenter.com
IN
10
9
11
8
7
6
5
4
3
2
1
12
13
14
15
16
KL6KL5KL4KL3KL2KL1
LittfinskiDatenTechnik(LDT)
ST2ST1
Rückmeldemodul RM-88-N
16- channel feedback module
Rev.1.0
BU1 BU2
s88-N
OUT IN
s88-N
OUT
16 Rückmeldeeing nge für den
s88-Rückmeldebus.
Rückmeldemodul
RM-88-N
s88-N
Digital-Profiwerden!
LittfinskiDatenTechnik(LDT)
www.ldt-infocenter.com
IN
10
9
11
8
7
6
5
4
3
2
1
12
13
14
15
16
KL6KL5KL4KL3KL2KL1
LittfinskiDatenTechnik(LDT)
ST2ST1
Rückmeldemodul RM-88-N
16- channel feedback module
Rev.1.0
BU1 BU2
s88-N
OUT IN
s88-N
OUT
16 Rückmeldeeing nge für den
s88-Rückmeldebus.
Rückmeldemodul
RM-88-N
s88-N
Digital-Profiwerden!
LittfinskiDatenTechnik(LDT)
www.ldt-infocenter.com
IN
10
9
11
8
7
6
5
4
3
2
1
12
13
14
15
16
KL6KL5KL4KL3KL2KL1
LittfinskiDatenTechnik(LDT)
ST2ST1
RückmeldemodulR M-88-N
16- c hannel feedback module
Rev.1.0
BU1 BU2
s88-N
OUT IN
s88-N
OUT
16 Rückmeldeeing n ge für den
s88-Rückmeldebus.
Rückmeldemodul
RM-88-N
s88-N
Digital-Profiwerden!
LittfinskiDatenTechnik(LDT)
www.ldt-infocenter.com
IN
10
9
11
8
7
6
5
4
3
2
1
12
13
14
15
16
KL6KL5KL4KL3KL2KL1
LittfinskiDatenTechnik(LDT)
ST2ST1
Rückmeldemodul RM-88-N
16- channel feedback module
Rev.1.0
BU1 BU2
s88-N
OUT IN
s88-N
OUT
16 Rückmeldeeing nge für den
s88-Rückmeldebus.
Rückmeldemodul
RM-88-N
s88-N
Digital-Profiwerden!
LittfinskiDatenTechnik(LDT)
www.ldt-infocenter.com
IN
10
9
11
8
7
6
5
4
3
2
1
12
13
14
15
16
KL6KL5KL4KL3KL2KL1
LittfinskiDatenTechnik(LDT)
ST2ST1
RückmeldemodulR M-88-N
16- c hannel feedback module
Rev.1.0
BU1 BU2
s88-N
OUT IN
s88-N
OUT
16 Rückmeldeeing n ge für den
s88-Rückmeldebus.
Rückmeldemodul
RM-88-N
s88-N
Digital-Profiwerden!
LittfinskiDatenTechnik(LDT)
www.ldt-infocenter.com
KL1
s88Rückmeldebus
HighSpeedInterface88
HSI-88
Rev. 2.1
LittfinskiDatenTechnik
br. gelb
14..18V~
Computer
RS232
Schnelles Computer-Interface für den s88-Rück-
meldebus. Ermöglicht 3 Rückmeldestr ng e.
High Speed Interface-88
HSI-88
Digital-Profiwerden!
LittfinskiDatenTechnik (LDT)
www.ldt-infocenter.com
LEFTMIDDLERIGHT
SolderSide
Adap-HSI-s88-N Rev.1.1
LittfinskiDatenTechnik (LDT)
Computer
RS232
Bestellbezeichnung /
Order code:
Kabel Patch 0.5m,
Kabel Patch 1m,
Kabel Patch 2m
oder / or
Kabel Patch 3m
Bestellbezeichnung /
Order code:
Kabel Patch 0.5m,
Kabel Patch 1m,
Kabel Patch 2m
oder / or
Kabel Patch 3m
The above example shows a possible distribution of feedback
modules to the three inputs.
The administration and addressing of the feedback modules will
be supported by your model railway software.
How to register additional feedback modules please consult the
manual of your model railway software.
Standard feedback modules of the s88 feedback system
usually include 16 inputs.
With the HSI-88 up to 31 of those feedback modules (62 of LDT
RM-GB-8-N track occupancy detection modules with 8 inputs)
can be controlled. Max. 31 modules can be connected on each
bus line. The summary of all three lines shall not extend a total
of 31 modules.
All s88-feedback bus compatible feedback modules can be
connected to the interface HSI-88.
Beside the LDT modules RM-88-N and RM-88-N-O for moment-
contacts and the RM-GB-8-N for track occupancy detection even
different types of feedback modules from different manufacturers
can be used.
Different brands and types can be connected to the feed back
lines even if they are mixed.
Further examples for using the HSI-88 and other LDT products
for performing feedback tasks with various kind of contacts can
be downloaded from our Internet Page (www.ldt-infocenter.com)
from the download section.
For the HSI-88-B kit a solid low-priced casing is available under
the part number LDT-01. Further details are available on our
Internet Page.
Communication with the PC:
After switching on the power supply a red LED at the HSI-88 will
indicate ready-to-operate.
The HSI-88 works event driven that means that each feedback
information will be transferred directly to the PC. This saves
considerable PC resources and shortens the reaction time as
the PC does not have to poll feedback information in cycles
(which means delays) but the HSI-88 itself will report each
change to the PC directly and without delay.
During interaction between PC and HSI-88 via the serial port
the red LED will be OFF. As the interaction will be very fast the
LED will show therefore a kind of flickering.
If you want to include the communication with the HSI-88 into
your own written model railway software you can download a
list of complete commands from our LDT-Internet Page
(www.ldt-infocenter.com).
Trouble shooting:
What to do if something is not working as described above?
If you have purchased the interface as a kit please check
carefully all parts and all soldered joints.
Here you will find some descriptions of failures and the causes
respectively how to solve the problem:
1. The rail way software does not recognize the HSI-88.
Feedback information will not be transferred from Interface to the
PC.
•Is the LED of the HSI-88 on after switching the unit on? If
not, check the power supply on clamp KL1.
•Is the LED flickering after starting the rail way software?
Background: after starting the software the PC tries to
contact the registered HSI-88 Interface and the LED should
flicker. Does the LED not flicker it is possible that the COM
port is defective.
Check this by changing the serial ports of the digital
control unit with the port of the Interface HSI-88.
2. After starting the rail way software the LED of the HSI-88
Interface flickers. Nevertheless there will be no connection.
Deactivate the FIFO-Buffer of the connection adjustment for the
COM interface where the HSI-88 is connected to the PC. With
respect to the PC operating system (Win2000, XP, Vista, Win7,
Win8 e.g.) via Working Place, System Control, System and
Device Manager or similar.
Further products from our
Digital-
Professional-Series
:
Adap-HSI-s88-N
Via the 3-fold Adapter is it possible to connect s88-feedback
modules directly via the screened Patch-Kabel to the Interfaces
in accordance to
s88-N
.
RM-88-N / RM-88-N-O
16-fold feedback module with 16 inputs (RM-88-N as Märklin
s88 switching against ground, RM-88-N-O with 16 galvanic
separated opto-coupler inputs) for s88-standard connections
and
s88-N
.
RM-GB-8-N
8-fold feedback module with integrated occupancy detectors
for a current load up to 3 Ampere (peak current 7 Ampere) for
s88-standard connections and
s88-N
.
All products can be supplied as easy to assemble complete kits
as finished modules or as finished module in a case.
Made in Europe by
Littfinski DatenTechnik (LDT)
Bühler electronic GmbH
Ulmenstraße 43
15370 Fredersdorf / Germany
Phone: +49 (0) 33439 / 867-0
Internet: www.ldt-infocenter.com
Subject to technical changes and errors. 07/2019 by LDT
Märklin is a registered trademark.

This manual suits for next models

1

Other LDT Recording Equipment manuals

LDT LS-DEC-NMBS-F User manual

LDT

LDT LS-DEC-NMBS-F User manual

LDT Light@Night User manual

LDT

LDT Light@Night User manual

Popular Recording Equipment manuals by other brands

Thor Broadcast H-16QAM-IP-RF user manual

Thor Broadcast

Thor Broadcast H-16QAM-IP-RF user manual

Kvaser U100P-X1 user guide

Kvaser

Kvaser U100P-X1 user guide

Roland RSS AR-3000R Brochure & specs

Roland

Roland RSS AR-3000R Brochure & specs

Yamaha PLG150-AN Tutorial

Yamaha

Yamaha PLG150-AN Tutorial

Videoswitch Vi305 user manual

Videoswitch

Videoswitch Vi305 user manual

KYOWA PCD-300B Hardware instruction manual

KYOWA

KYOWA PCD-300B Hardware instruction manual

TEXIO LW Series instruction manual

TEXIO

TEXIO LW Series instruction manual

Sony SRW-1 Operation manual

Sony

Sony SRW-1 Operation manual

Alesis Q20 user manual

Alesis

Alesis Q20 user manual

Sencore OmniHub 6 user manual

Sencore

Sencore OmniHub 6 user manual

AudioArts Engineering R-55 Technical manual

AudioArts Engineering

AudioArts Engineering R-55 Technical manual

Erica Synths POLIVOKS-INSPIRED EG Guide to assembly

Erica Synths

Erica Synths POLIVOKS-INSPIRED EG Guide to assembly

Nexo NXAMP 4X4 Service manual

Nexo

Nexo NXAMP 4X4 Service manual

LORD 3DM-GX5-35 manual

LORD

LORD 3DM-GX5-35 manual

Digital Audio Labs LIVEMIX DA-816 user guide

Digital Audio Labs

Digital Audio Labs LIVEMIX DA-816 user guide

AKG DFM 4X4 Quick reference guide

AKG

AKG DFM 4X4 Quick reference guide

Acom PC-100 operating manual

Acom

Acom PC-100 operating manual

epiphan VGADVI Broadcaster Pro user guide

epiphan

epiphan VGADVI Broadcaster Pro user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.