Lead MRS4616A User manual

4/8/16E1 over Ethernet aggregation Gateway
1
Contents
Contents........................................................................................1
Preface ..........................................................................................2
Chapter One Overview .................................................................3
1.1 Outlet ..................................................................................3
1.2 Equipment Features ............................................................3
Chapter Two Function Specification ............................................4
2.1 Introduction to Front Panel of the Device...........................4
2.2 Introduction to the rear panel of the equipment..................6
Chapter Three Technical Specifications.......................................7
3.1 Operating Environment.......................................................7
3.2 Power Supply Section.........................................................7
3.3 Mechanical Specifications ..................................................7
3.4 E1 Interface.........................................................................7
3.5 Ethernet Interface................................................................7
Chapter four WEB Setting............................................................8
4.1 WEB Login.........................................................................8
4.2 System configuration..........................................................8
Chapter Five Accessories............................................................15
5.1 Method of making lines....................................................15
5.2 Warranty Card...................................................................17

4/8/16E1 over Ethernet aggregation Gateway
2
Preface
Version Description
Manual version: V1.0
Copyright Notice
The copyright of this manual is reserved to our company, who
retains the final rights of explanation and revision to this manual
and notice. No part of this manual may be photocopied, excerpted,
reproduced, revised, transmitted, translated into other languages, or
used for commercial purpose in full or in part, without the prior
written permission of the Company.
Disclaimer
This manual is made according to currently available information
and subject to change without further notice. Whilst every effort has
been made to ensure the accuracy and reliability of the contents
contained herein, the Company cannot be held liable for any harm
or damage resulting from any omissions, inaccuracies or errors
contained in the manual.
Brief Introduction
This User Manual describes the installation and operation of
Ethernet aggregation Gateway Equipment. Before you use our
device for the first time, please read all the included materials
carefully, and install and operate this series of products in keeping
with items listed in the manual, so as to avoid damaging the device
resulting from malpractice. Thank you for choosing our products.
Environmental Protection
This product complies with the design requirements associated with
environmental protection. The storage, use and disposal of the
product should be conducted in accordance with related national
laws and regulations.
We welcome you to put forward advice and suggestion to
our work, which shall be viewed as the ultimate support to us.

4/8/16E1 over Ethernet aggregation Gateway
3
Chapter One Overview
1.1 Outlet
4/8/16E1 over Ethernet aggregation Gateway is a channelized Ethernet
gateway for interconnecting TDM and packet-based networks. The
Ethernet Gateway aggregates and switches Ethernet traffic into 4, 8 or
16 channelized E1 circuits, each supporting up to 31 Ethernet logical
channels (31 over N*64K). Ethernet traffic over channelized E1 lines
is aggregated and transferred to the packet-switched network via the
unit’s Gigabit Ethernet ports. The encapsulation method support
HDLC/PPP-BCP (RFC3518)/GFP-F.
1.2 Equipment Features
Support 4-port Ethernet electrical interfaces, 2- port Ethernet electrical
interfaces or 2-port fiber interface,16-port E1 channel, and make the
Ethernet data gathering into E1 channel.
Support maximum 2047 bytes and provide 2kBytes MAC address
buffer space
Support the Ethernet VLAN isolation function.
Single E1 channel support HDLC/PPP-BCP (RFC3518)/GFP-F
encapsulation, double E1 channel support GFP encapsulation.
Support E1 frame or un-frame application, and N*64K for framed
mode.
Provide Console, Telnet, WEB and SNMP Management.
Support software and firmware upgrade.
-48VDC/220VAC flexible redundant power inputs.

4/8/16E1 over Ethernet aggregation Gateway
4
Chapter Two Function Specification
2.1 Introduction to Front Panel of the Device
Figure1 E1 120Ω,2TX+2FX
Figure2 E1 120Ω,4TX
Figure3 E1 75Ω,2TX+2FX
Figure4 E1 75Ω,4TX
NOTICE: 8E1, only the first 8-way effective
4E1, only the first 4-way effective
2.1.1 Front Panel Indicators Specification
Ethernet

4/8/16E1 over Ethernet aggregation Gateway
5
There are 9 indicators on the front panel of the device, and their functions
are:
NOTICE: LOS LIGHT 8E1, only the first 8-way effective
4E1, only the first 4-way effective
LED
Name
Colors
Functions
Status
Description
PWR
GREEN
Power
Indication
on
Power supply normal
off
Power off
FB2
GREEN
FB2
Indication
on
Fiber connected
flash
Device transmitting
data.
off
Fiber Disconnected
FB1
GREEN
FB1
Indication
on
Fiber connected
flash
Device transmitting
data.
off
Fiber Disconnected
SYS
YELLOW
System status
flash
System working
on
System abnormal
off
System booting
normally
LOS1~16
RED
1-16 Channels
Alarm
on
Channel loss signal
off
Normal
SPD1~4
GREEN
Ethernet
Speed status
on
100M
off
10M
ACT1~4
YELLOW
Ethernet
Activity
flash
Device transmitting
data.
on
Network is established
off
Disconnected

4/8/16E1 over Ethernet aggregation Gateway
6
2.1.2 The front of panel interface description
There are 4 Ethernet electrical interfaces, 2 Ethernet electrical
interfaces or 2 SFP fiber interface, one Console, 4/8/16 E1 interface
and RESET button on the front of panel.
Ethernet Interface
Use the Ethernet Interface with lights.
Reset
The system is in normal operation, if continuously press the Reset
button more than 3 seconds, the system will restore factory default
configuration and reboot.
E1 Interface
Q9(75Ω), RJ45(120Ω)
Console
The device provides a series of Config commands and CLI for
configuring and managing the device. Local Config via the Console
port.
2.2 Introduction to the rear panel of the equipment
Figure of Rear Panel
2.2.1 Power
Two way power interface, 220VAC and -48VDC. When 220VAC,
POWER link L and RETURN link N, when -48VDC, POWER link "+"
and RETURN "-".

4/8/16E1 over Ethernet aggregation Gateway
7
Chapter Three Technical Specifications
3.1 Operating Environment
The device has a wide range of operating temperature and is able to work
normally and stably in highly adverse environment.
Working Temperature 0℃~+50℃
Storage Temperature -40℃~+70℃
Relative Humidity 10 %~95 %
Atmospheric Pressure 70~106 kpa
The environment should be free from corrosive and solvent gases, dust, and
magnetic interference.
3.2 Power Supply Section
Input Voltage:AC 220V/DC 48V
Voltage Fluctuation:100VAC~240VAC/40VDC~72VDC
Power Consumption:<10 W
3.3 Mechanical Specifications
Appearance dimension: 430mm*203mm*44.5mm
3.4 E1 Interface
Interface Impedance:75Ω,120Ω
Connector Type: Q9(75Ω), RJ45(120Ω).
3.5 Ethernet Interface
Fast Ethernet Speed rate: 10M/100M Auto-negotiation、10M half-Duplex、
10M Full Duplex、100M Half-Duplex, 100M Full Duplex Optional.
Support VLAN and QinQ function
IEEE 802.3u auto-negotiation

4/8/16E1 over Ethernet aggregation Gateway
8
Chapter four WEB Setting
4.1 WEB Login
Use IE browser as an example. Open the web browser, input the
default IP address in the address bar: 192.168.0.168.
As below the login dialog, input the right username and password. The
username and password is all “root”.
4.2 System configuration
4.2.1 System information
Software Version.
Firmware Version.
Running Time.
MAC Address.
System Name.
System Reboot.
4.2.2 Network configuration

4/8/16E1 over Ethernet aggregation Gateway
9
IPAddress: 192.168.0.168.
Net Mask.
Default Gateway.
4.2.3 Password configuration
User can change password on this page and re-login use the new
password.
4.2.4 SNMP configuration

4/8/16E1 over Ethernet aggregation Gateway
10
Test SNMP function in this web page.
4.2.5 Global Configuration
Dot1Q Vlan Enable: Vlan&QinQ function enable.
Admin Vlan: User interface VLAN
QinQ Enable: Double Vlan enable.
QinQ Ether Type: Double Vlan type setup.
E1 QinQ Pvid: Double VLAN value.
Ethernet Isolation
4.2.6 Channel configuration

4/8/16E1 over Ethernet aggregation Gateway
11
E1 can be set to the un-frame or framing under HDLC mode, frame
1~31 timeslot can choice frame mode. Selecting any timeslot or timeslot
interval or their combination through the Time Slot. Every Channel ID
corresponding one E1 under HDLC mode, E1 can't repeat.
4.2.7 Ethernet configuration
Config Mode: Set the work mode of the Ethernet
①auto②half-10③full-10④half-100⑤full-100
Ethernet rate-limiting function ①Egress Rate Limit transmit
②Ingress RateLimit receive:The default configuration is 0.
4.2.8 E1 Test

4/8/16E1 over Ethernet aggregation Gateway
12
Open this web page, set the E1 Index same with self-loop port number,
Pattern Text choice enable and click Config to check the E1 circuit is
normal or not.
4.2.9 Vlan enable
Support 16 vlan tables:
Vlan table will be effective when 'Dot1Q Vlan' function in 'System
Config' page is enabling.
0 delete vlan, management vlan can’t be delete.
If corresponding vlan is deleted, pvid need be reset.
4.2.10 E1 alarm

4/8/16E1 over Ethernet aggregation Gateway
13
This page shows the E1 alarm.
4.2.11 Ethernet Statistics
Ethernet statistics will automatically refresh every 10s.
4.2.12 Channel statistics

4/8/16E1 over Ethernet aggregation Gateway
14
Channel statistics will automatically refresh every 10s.
4.2.13 System update
Update the software and firmware in the page, the software must be
named as *.bin and firmware must be named as *.rbf.
NOTICE:
8E1, WEB page only shows 8 E1 content.
4E1, WEB page only shows 4 E1 content.

4/8/16E1 over Ethernet aggregation Gateway
15
Chapter Five Accessories
5.1 Method of making lines
5.1.1 How to make E1 connecting cable
75ΩLine Making Method: 120ΩLine Making Method:
Connection between core and The pins are arranged as follows:
core and between skin and skin;
No connection between skin and core
5.1.2 Making of Console Interface Connecting Cable
5.1.3Making of Ethernet Interface Connecting Cable
Ethernet interface Connecting Cable adopts twisted pair line with its specific
making methods divided into two international standards, which are
EIA/TIA568A and EIA/TIA568B. Position the tail of crystal head
downward (i.e. the flat side upward), determine the lines with figures as 1 2
3 4 5 6 7 8 from left to right, and the distributions of each line are as
follows:
(EIA/TIA568A standard)
(EIA/TIA568B standard)
Pin
No.
Connection signal
Sequence of
twisted pair line
Pin
No.
Connection
signal
Sequence of
twisted pair
lines
1(+), 2(-) pins are input pins
4(+), 5(-) pins are output pins
Pin3 is output pin(TXD)
Pin6 is input pin (RXD)
4, 5 pins are GND
pins(GND)
1, 2, 3, 4, 5, 6, 7, 8

4/8/16E1 over Ethernet aggregation Gateway
16
1
TX+(transmission)
White and green
1
1
TX+(transmi
ssion)
White and
orange
2
TX-(transmission)
Green
2
TX-(transmis
sion)
orange
3
RX+(receive)
White and
orange
3
RX+(receive
)
White and
green
4
Not to be used
Blue
4
Not to be
used
Blue
5
Not to be used
White and blue
5
Not to be
used
White and
blue
6
RX-(receive)
Orange
6
RX-(receive)
Green
7
Not to be used
White and
brown
7
Not to be
used
White and
brown
8
Not to be used
Brown
8
Not to be
used
Brown
RJ-45 twisted pair line is specified as follows:
1)1, 2 used to send; 3, 6 used to receive; 4, 5,7, 8 are bi-directional lines.
2)1, 2 must be pair twisted; 3, 6 pair twisted; 4, 5 pair twisted; 7, 8 pair
twisted.
Making of straight-through line: both heads are connected as per T568B line
sequence standard. Making method of crossover line: one head is connected
as per T568A line sequence while the other head is connected as per T568B
line sequence. The follows are specific connection conditions:
1) The device is connected with PC and router: straight-through line shall be
adopted with the same connecting method on both ends of network line.
2) The device is concatenated with switch (or HUB): crossover line shall be
adopted with different connecting method on both ends of network line.

4/8/16E1 over Ethernet aggregation Gateway
17
5.2 Warranty Card
Our company is committed to provide users with the following terms:
1. Warranty service
1) Within the charge free warranty term (within 12 months
since the purchase of the product), damaged parts can be
exchanged free of charge and maintenance charges will be
free in the conditions that the device is considered to be
malfunctioned in normal service by our company.
2) Within the charged warranty term (more than 12 months
and within 36 months since the purchase of the product),
damaged parts will be charged for corresponding cost
with free maintenance service in the conditions that the
device is considered to be malfunctioned in normal
service by our company.
2. Users can not enjoy warranty service with the following cases and
corresponding cost of damaged parts replacing and maintenance
service will be charged
(1)Exceed 36 months since the purchase of the product
(2)Can’t provide certificate of purchasing date, and serial
No. of product shows that ex-works term has exceeded 36
months;
(3)Include but not limit to the abnormal service conditions
such as violent knocking, extrusion, drop, liquid
immersion that cause damages;
(4)Fragile label on the device is damaged;
(5)User disassembles this product himself
(6)Force majeure that leads to product damage, such as
earthquake, flooding and lightening stroke;
3. The newly installed parts after maintenance will be repaired free of
charge within 12 months since the installation date.
4. When malfunction occurs, users can choose to send it to our
company to receive maintenance service or to post it to
maintenance points of our company all over the country to be
repaired.
5. Our company does not undertake any responsibilities for losses
caused by abnormal operation; for losses really caused by
product itself, including but not limited to all direct or indirect
losses due to data loss, our company will only undertake
responsibilities within the selling price of products.

4/8/16E1 over Ethernet aggregation Gateway
18
Repair and Maintenance Record
Product Name: Ethernet aggregation Gateway
Device No.:
Maintenance date
No. of Service Bill
1
2
3
4
5
This manual suits for next models
2
Table of contents
Popular Gateway manuals by other brands

ZyXEL Communications
ZyXEL Communications P-792H Declaration of conformity

LG-Ericsson
LG-Ericsson iPECS SBG-1000 user manual

hilscher
hilscher netNode Hardware Description Installation Instructions

Sunricher
Sunricher SR-GW-TDA manual

Lierda
Lierda LSD4WN-2332XGW1 user manual

RTA
RTA 460BSUS-NNA4 Product user guide