01 SAFETY INFORMATION
WARNING!!!
Carefully read before installing, powering or servicing. Nothing to
do if anything misunderstand! Installation can be done only by a
qualied professional in accordance with relevant local codes.
01.1 Safety instructions
Shut down power before installation or maintenance of equipment or
voltage /data source.
Do not modify, alter, or attempt to service the LeaderLight appliance. Doing
so will void the warranty.
Use only the recommended DC voltage source.
Connect the ground to the bottom of the box!
Electrical connections, service and maintenance can be performed only by
qualied professional.
AC power supply of DC power supply must comply with local regulations.
AC power supply must be protected against overvoltage and short circuits.
-
-
-
-
-
-
-
01.2 Operating restrictions
This product was designed for indoor use only!
If the product has been exposed to drastic temperature uctuation (e.g. after
transportation), do not switch it on immediately. The arising condensation
water might damage your unit. Leave the unit switched off until it has
reached room temperature.
Do not operate the product in humid, dusty or too hot/cold environments.
Before connecting, make sure the product is not damaged, wet, or otherwise
damaged.
Unprofessional operation creates the most damages!
For transport use the original packaging.
-
-
-
-
-
-
Operate only with 24V DC stabilized source!
01.3 Fire protection
Follow all safety restrictions.
Device never cover – the minimum space around the vents must be at least
100mm (4 in.).
Allowed maximum ambient temperature is 40°C (104°F).
-
-
-
02 PRODUCT SPECIFICATION
02.1 Technical specication
Power connection: DC24V max. 10W
Output: 8x analog output 1-10V DC, max. 100mA
Control data: Protocol USITT DMX-512 or RS 423/232 LL dened protocol
Ambient temp. (Ta): 0°C ÷ +40°C
Net weight: 0,36 kg
Dimensions LxWxH: 107mm x 105,4mm x 73,5mm
Installation: standard DIN installation TS35 – 6DIN
02.2 Product description
Indication of control LEDs (LED power- green,LED data - yellow)
LED Indication Status
LED Power blinking - 2Hz O.K. - device is working correct
LED Data not lit No DMX signal
LED Data blinking - 4Hz O.K. - Connected the correct DMX signal
LED Data fast blinking ERROR - incorrect digital signal
LED Power &
LED Data
alternating
blinking function AutoTest
03 INSTALLATION
03.1 Unpacking
Unpack carefully.
This is electronic equipment and should be handled carefully.
Damaged delivered package or if are any mechanical parts broken – it must
be claim immediately by the transport company. Photo pictures as evidence
are valuable for future claim.
-
-
-
03.2 Physical installation
Loading capacity of bearing area has to be at least 10 times the weight of all
device clusters.
-
03.3 Connection
Respect all SAFETY INFORMATION 01!
Connect the ground (earth) to the bottom of the module!
LL ANA8 device may be operated only with 24V DC stabilized source.
In the case of connecting the power supply with more than a prescribed
voltage you can suffer a dangerous electric shock, inict damage equipment
or re.
Shut down power supply from all devices before installation of LL ANA8 to
end devices.
-
-
-
-
-
75,4
107 73,5
105,4
Leader Light s.r.o.
M.Gorkeho 33
SK-052 01 Spisska Nova Ves
Slovakia
www.leaderlight.eu
USER MANUAL
LL ANA8 - Analog module
LL08 400
COMPLIMENTS ON YOUR PURCHASE!
All dimensions are in millimeters
Package includes:
LL ANA8- 1 pc.
User manual- 1 pc.
Additional items needed:
Data and power cables-
24V DC power supply-
Content:
01 SAFETY INFORMATION
01.1 Safety instructions
01.2 Operating restrictions
01.3 Fire protection
02 PRODUCT SPECIFICATION
02.1 Technical specication
02.2 Product description
03 INSTALLATION
03.1 Unpacking
03.2 Physical installation
03.3 Connection
03.4 Installation factors
03.5 DMX channels
04 MAINTENANCE AND SERVICE
ENVIRONMENTAL PROTECTION
Do not throw away the appliance with the normal household waste at the end of
its life, but hand it in at an ofcial collection point for recycling. By doing this, you
help to preserve the environment.
Control data
6pin line conector
DC 24V
power
DIP
settings
8x analog output
4x 6pin line conector
Rotating DIP
Control
LEDs
“100“
OUT1 OUT2
+-
+v
+-
+v
OUT3 OUT4
+-
+v
+-
+v
OUT5 OUT6
+-
+v
+-
+v
OUT7 OUT8
+-
+v
+-
+v
LL ANA8
Made in EU
Leader Light s.r.o. Slovakia, 2010
www.leaderlight.eu
[email protected]
D- D+ D- D+ 1 2 3 4 x100 x10 x1 +24V D
A
T
A
P
O
W
E
R
POWER
INPUT
DMX 512
RS 423/232
DIP CHANNELS
MODE & ADDRESS
S/N
DC 24V INPUT, Tmax:40°C
300mA MAX for EACH OUTPUT
0V
“10“ “1“
Wiring diagram LL ANA8 module
If you have any question please, contact [email protected]
Feature LL ANA8:
LL ANA8 is addressable analog output module. The device is designed primary
to control the electronic ballasts with Input 1-10V
03.5 DMX channels
These informations are subject to change, latest data are on: www.leaderlight.eu
Mode1:
Channel 1 = Analog output 1
Channel 2 = Analog output 2
Channel 3 = Analog output 3
Channel 4 = Analog output 4
Channel 5 = Analog output 5
Channel 6 = Analog output 6
Channel 7 = Analog output 7
Channel 8 = Analog output 8
Analog output = 1-10V DC
Feature DipBCD ( rotary switch RS1 - “100”, RS2 - “10”, RS3 - “1”):
DipBCD = 000 = DMX address 001
DipBCD = 001 – 512 = DMX address 001 – 512
DipBCD = 9xx = AutoTest: Fade-Over
DipBCD = 8xx = AutoTest: all channels on 50%
DipBCD = 7xx = AutoTest: all channels on 100%
DipBCD = 6xx = Service Test: all channels at 0,10,20 ,..., 90% by
DipBCD RS3 - “1”
Feature Dip ( switch Dip1, Dip2, Dip3, Dip4 ):
Dip1 = Zap = if the command RSX is not present more than 7s, all
channels are set on 100%
Dip2 = Zap = without function
Dip3 = Zap = without function
Dip4 = On = activation protocol RSX3b (only if power is switched on)
Description of RSX3b protocol is in a separate annex.
03.4 Installation Factors
For any indoor and outdoor installation inside the installation box must
be add +100mm to each side and must be add ventilation modul.
For outdoor installation must be add heating modul, if the outdoor
temperature is less then 0°C any time!
-
-
04 MAINTENANCE AND SERVICE
Before any maintenance is necessary to carefully read all SAFETY
INFORMATION 01!
Damages caused by inadequate cleaning or maintenance are not covered by warranty.
Requires periodic cleaning (dust, dirt ,...)
Procedure for maintenance:
Unplug mains before maintenance and at least 10 minutes cool off.
Appliance do not illegal open or demount.
Clean-up dust only from outer surface. Use vacuum or dumpy duster (warm
water)
Before reinstalling make sure everything is intact and dry– no wet parts!
Service:
Customer service provided by the manufacturer.
-
-
-
-
-
-
-
-
Edition: A - 2010
©MMX - Leader Light – All right reserved
Cable:
CY 1.5, CYKY 3x 1.5
FTP 4X2XAWG24 Cat 5e
to control unit
to the next module
bus data
RS 423/232
stabilized
supply
230V/24VDC
FTP 4X2XAWG24 Cat 5eFTP 4X2XAWG24 Cat 5e
CY 1.5, CYKY 3x 1.5
L
OUT1 OUT2
+-
+v
+-
+v
OUT3 OUT4
+-
+v
+-
+v
OUT5 OUT6
+-
+v
+-
+v
OUT7 OUT8
+-
+v
+-
+v
LL ANA8
Made in EU
Leader Light s.r.o. Slovakia, 2010
www.leaderlight.eu
[email protected]
D- D+ D- D+ 1 2 3 4 x100 x10 x1 +24V D
A
T
A
P
O
W
E
R
POWER
INPUT
DMX 512
RS 423/232
DIP CHANNELS
MODE & ADDRESS
S/N
DC 24V INPUT, Tmax:40°C
MAX 100mA for EACH OUTPUT
0V
dimmable
electronic ballast
+
-
+
-
+24V
150ohm/5W
Output 1-10V, max. 100mA
for general use

Popular I/O System manuals by other brands

National Instruments Isolated Analog Input Modules SCC-AI01 user guide

National Instruments

National Instruments Isolated Analog Input Modules SCC-AI01 user guide

M-system R7HL-PA4E instruction manual

M-system

M-system R7HL-PA4E instruction manual

DMP Electronics 1154 installation guide

DMP Electronics

DMP Electronics 1154 installation guide

Advantech ADAM-6100EI Series user manual

Advantech

Advantech ADAM-6100EI Series user manual

Burkert FieldConnect ME64 operating instructions

Burkert

Burkert FieldConnect ME64 operating instructions

STW TCGi Quick Start Guide for Starting Up

STW

STW TCGi Quick Start Guide for Starting Up

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

WAGO 750-344 manual

WAGO

WAGO 750-344 manual

Fluke 2638A Calibration manual

Fluke

Fluke 2638A Calibration manual

Portwell WEBS-5491 user manual

Portwell

Portwell WEBS-5491 user manual

Measurement Computing PCI-DAS4020/12 user guide

Measurement Computing

Measurement Computing PCI-DAS4020/12 user guide

Regin ADD:IO manual

Regin

Regin ADD:IO manual

Siemens SIMATIC ET 200SP DI 8x24VDC ST manual

Siemens

Siemens SIMATIC ET 200SP DI 8x24VDC ST manual

Festo CPX-E-4IOL manual

Festo

Festo CPX-E-4IOL manual

Siemens SIMATIC ET 200S operating instructions

Siemens

Siemens SIMATIC ET 200S operating instructions

EverFocus EPRO NVR Series user manual

EverFocus

EverFocus EPRO NVR Series user manual

Yottacontrol A-1019 quick start guide

Yottacontrol

Yottacontrol A-1019 quick start guide

Advantech WISE-4610 Series user manual

Advantech

Advantech WISE-4610 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.