WIRE CONNECTIONS AND EQUIPMENT INSTALLATION
Checkallwiresforshortstoeachotherandforgrounds. Connectallwires (EXCEPT117VACCONNECTIONSTOTRANSFORMERS)asshowninthe
connecting diagram FIG. 5 and in accordance with the wiring instructions.Refer to FIG. 6 for dual entrance wiring.
ENTRANCEPANEL(VM-300/4T):
A. Install frame (OF-200 series) into housing (BB-200 series).
B. Connect all wires necessary as shown in connecting diagram FIGURE. 5. Refer to FIGURE. 6 for dual entrance wiring.
C.Connectcoaxialvideocable(RG-59U)tothecameracableconnectoronthebackofthecamera.Connecttheremainingwiresfromthecableconnector
to CN and CP to supply power.
D.Installthefront panels into frame following thedirections included with thedirectory panel.
VIDEO MONITOR (VM-104):
A.Connect allnecessarywires asshowninthe connectingdiagramFIG. 5. RefertoFIG.6 fordualentrance wiring.IH-357andIH-358 housingincludes
four knock-out holes for cable inlet.
B.Mount the VM-104 to theIH-357 andIH-358 ringhousing usingthe adapterplate.
TRANSFORMER(PS-250):
A.Connecttransformer16voltterminalstoPK-314A,terminalsT1andT2.Connecttransformerprimaryto117VACobservingallapplicableelectricalcodes.
SYSTEM CHECK-OUT
Checkentiresystemaccordingtotheoperatinginstructions,turningeachmonitoronindividuallysothatifaproblemexistsitmaybeeasilyidentified.Ifthe
systemdoesnot operate as indicated, referto TroubleShooting section.
OPERATINGINSTRUCTIONS
A. ATENTRANCE PANEL(VM-300/4T Van-Guard ®, or QM-300/2QuantumTM):
1.Momentarily press buttoncorrespondingtodesiredsuite.
2. Reply in a normal voice when spoken to. Reply is hands-free.
3.Whendoorrelease buzzes, enter through door.
B. ATSUITE STATION (VM-104):
1. When call tone is heard, pick up intercom handset.
2. Adjust picture brightness and contrast as necessary using the slide control switches located just below lower right corner of video screen.
3. Identify caller on the video screen and converse with them.
4. The door may be opened by pressing the door release button marked "Door".
Eachmonitorstaysonforapproximately1minutewhencalled. Pictureisdelayedapproximately3to5seconds.Whenthedoorreleaseisactivatedorwhen
a second caller rings another suite, the monitor will shut off.
CallsmayalsobeinitiatedfromtheVM-104bypressingthevideomonitorbuttonmarked "Monitor".Thisactivatesthecameraandmaybeusedtore-initiate
acallthathas beencanceled,ortomonitortheentrancepanel. Themonitorwillstayonforapproximately1 minute.Only1monitoratatimeshould beon
usingvideomonitorbutton.
IfstandbycontrolisswitchedON,redLEDwilllightandmonitorwillremainonstandby,readytooperatewhenanothercallisplacedfromtheentrancepanel.
NOTE:
Performancemayvarywithlargeorsmallinstallations.Ifnovideocontactwiththeentranceisdesiredorifatenantisleavingthesuite,thestandby
switchmay be turned OFF. Audiocommunication willstill operatein thenormal manner.
SYSTEM MAINTENANCE
ENTRANCEPANEL(VM-300/4T):
Directorypanelsareaccessiblebyremovingtheself-tappingmetalscrew(s)locatedinthetopL-channeljustaboveeachmodule.Afterremovingscrews,
lift L-channel away from frame. Panel can now be removed. Apply directory listings as desired and replace panels be reversing the above procedure.
CONTROL UNIT (PK-314A):
EachPK-314A has a 5amp, 3AGfuse as an overloadprotection. Replace this fusewith same type andrating only. If thisfuse continually opens, check
forwrongwiringor equipmentfailure.