“Almost” Everything You Need To Know…
To GetItRunning… andKeep ItRunning
FILTERPUMPOPERATION
NOTE: Some systems utilize a timer to control filter pump run
time. If a timer is present, follow instructions below:
TOSTOPTHEHEATER
Select: OFF via the MODE selector. This method of shut down
preserves the controller settings; an interruption of water flow–
such as when a pump timer is in control–will also stop heat
pumpoperation.
1. Verify Electrical Power is Present at Heater:
3. To Begin Heating:
–
GETTING STARTED
–
These instructions are intended for local control of a
heat pump, independent of an external controller.
OWNERS: if your installation includes an external controller, con-
tact your installing dealer, and/or the controller manufacturer, for
operational instructions.
2. Set the Heater Controls:
A. Make certain the heater has electrical power connected; the
controllerdisplayshouldbeilluminated.
B. If the display is blank, be certain the electrical breaker, and
heater disconnect, are switched to ON.
C. For now, leavethewatercirculationpumpOFF.
OWNER- If heater is connected to a Call-Flex controller, also
see: “Call-Flex Programming,” located within the “Owner Level
Programming”sectionoftheheatermanual.
INSTALLER-Is heater connectedtoan external controller?Ifso,
setupprogrammingisnecessary.See:“ControlsConfiguration,”
located within the “Level-2 Programming” section of the heater
manual.
(Setting SPA, continued) An illuminated SPAindicator light,
located on the left side of the display, will confirm the SPA
control has been selected. Use the UP / DOWN arrow keys
to set the desired water temperature for the SPA. If heating
only a POOL, using the DOWN arrow key, lower the SPA
temperature until OFF is displayed.
The heat pump controls are now set to maintain the desired
watertemperatureforthePOOLand/or SPA.
E.
F.
Theuser/ownersettingscanbe completedwithoutwater flow-
ing. Once the heater has electrical power connected, with
water not flowing,thedisplayshouldreadFLO.
PresstheMODEbuttonuntiltheHEAT (HEA)indicationdis-
plays.
Using the POOL/ SPAselector key, select the POOLmode.
An illuminated POOL indicator light, located on the left side
ofthedisplay, will confirmthePOOLcontrolhasbeenselect-
ed. If heating only a spa, using the DOWN arrow key, lower
the POOL temperature until OFF is displayed; then proceed
toStep-“E.”
If heating a pool, use the UP / DOWN arrow keys to set the
desiredwatertemperatureforthePOOLwater.
If the heat pump will be used to heat a spa, use the POOL/
SPA selector key to select SPA.
A.
B.
C.
D.
E.
Verify MODE is set to: HEAT(HEA); then, depending on the
bodyofwatertobe heated, use thePOOL/SPAselectorkey
to choose either POOL or SPA.
Positionexternalwatervalvesappropriatelyto flow water to-
and-fromthebodyofwater and through the heater.
Start the water pump; the fan will start...Within 4-minutes,
depending on the status of the controller’s internal time de-
lay, heating will begin.The water will be brought to tempera-
tureandmaintainedper the settingdeterminedpreviouslyin:
“SettheHeaterControls.”
Inoperation,whenever the actual(displayed)watertempera-
turefallsbelowthedesiredsetpoint,theunit will begin heat-
ing.
A.
B.
C.
D.
NOTE: Theheatercanonly operatewiththefilter pump running.
Itmaybe necessary,during coolerweather,to extendthepump’s
daily run time. This will enable the heater to keep up with in-
creased heat losses.
The filter pump will need to run continuously until the water
hasreacheddesiredtemperature.Ifatimercontrolsyourfil-
terpump,itwill be necessarytooverridethe timer toallowfor
temporary,continuous operation.
Oncethedesired watertemperaturehasbeen obtained(usu-
ally1-to-4days),resetthepumptimerfornormaloperation.
NORMALUSAGE
Aftertheheatpumphas been running forsometime,watermay
be seen around the unit. This is condensation produced as a
normalby-productoftransferringheatfrom the air to the poolor
spa.Quantitiesof6-8gallons per hour arenotuncommonwhen
the humidity is high. Water from heater seems excessive? See
“Water Coming From Heat Pump” later in this guide.
VERY IMPORTANT NOTE!! Waterchemistry…Yourheat pump
hasbeenengineeredfordurabilityandreliability;however,pro-
longed exposure to unbalanced water chemistry will result in
prematurefailureandservice requirements.
Keep chlorine in the 1-3 PPM range- If bromine is being used,
2.0 to 4.0 PPM.; pH between 7.4 and 7.6; Alkalinity, 80-100
PPM;hardness125PPM (or more).Exactneedswilldepend on
the type of pool surface; check with your pool service expert.
Seeownersmanualfor additional information.
MAINTENANCE &WINTERIZING
Your heat pump should be serviced annually by aqualifiedpool
heatpumpspecialist.Ifyourheatpumpislocatedonthebeach
or a sea wall, where salt spray and sand gets in or on the unit,
morefrequentmaintenancewillbenecessary.ContactCustomer
Supportfordetails (727-823-5642).
Provideproperairflowtothe heat pump. Keepthesidesandtop
oftheheatpumpfreeofobstructions.
ControlIrrigation:wherewells areusedforirrigation,water qual-
ity can be poor. Heat pump components can be damaged by
wellwater;regardlessofwaterquality, itisrecommendedsprin-
klers be directed away from the heat pump.
Drainage...aspreviouslystated,your heat pump,undervarious
conditions, will produce large quantities of condensation. Keep
the drain holes, located at the base of the heat pump, free of
grassandweeds.
If your heater is located under trees, leaves may fall and accu-
mulatein thebottomoftheheatpump.Accumulateddebrisshould
beremovedbyaqualified technician.
VERY IMPORTANT NOTE!! In areas where hard freeze condi-
tions occur, proper winterizing of the heat pump is critical. For
detailed instructions on winterizing, refer to “Winterizing” in the
heatermanualoratwww.aquacal.com.
Inareaswherelightfreezingconditionsoccur–lastinglessthan
four(4)hours–keep thewaterpump operating.Flowingwater will
not freeze under limited, light freeze conditions.