Lem Elettronica DSP40PRO+ User manual

WARRANTY YEARS
Total output level max 126dBµV
50dB digital filters on adjacent channels
Single filter selectable mode Standard/Narrow/Wide
Channel to channel conversion
Manual filter level adjustment (1)
Filter frequency OFF-SET adjustment (1)
UHF inputs Lte 700 filter with SAW technology
Dual-stage input amplifiers
Wide band AUX (40... 860MHz) input
DAB filter 174... 230MHz
Automatic Channel search from all inputs
Manual programming from display and APP
DSP40PRO+
LEM USB
AUTO
TUNING
Digital Signal Processor
INPUT
40-860MHz
FM
USB
MATV
OUT
TEST
-30dB
UHF
1
DC
UHF
2
DC
VHF/UHF
3
DC
UHF/DAB
4
DC
DSP40
PRO+
Digital Signal Processor
USER GUIDE
DC15V
DSP 40PRO+
. .
TV Terrestrial programmable amplifier
(1) Function only accessible with smartphone
programming.
RED
COMPLIANT
TECHNICAL SPECIFICATIONS
NUMBER OF INPUTS 61 FM; 2 UHF; 1 VHF/UHF; 1 DAB/UHF ; 1 AUX
INPUTS FREQUENCY RANGE MHz FM (40... 108) AUX (40... 862)
BIII/DAB 170... 240 / UHF 470... 694/862
SINGLE CHANNEL FILTERS 32
NUMBER OF CHANNEL PER FILTERS 1
INPUT LEVEL RANGES dBµV FM 35... 90 - BIII/DAB 40... 110 - UHF 40... 110
FILTERS SELECTIVITY dB >50 (Adjacent channels)
AUTOMATIC CONTROL GAIN RANGE dB 40 dB
VHF/UHF INPUTS AMPLIFIER GAIN 0 / +15 / +30
FM GAIN dB 45 (Adjustable 0... -30dB)
AUX GAIN dB 40 (Adjustable 0... -20dB)
VHF GAIN dB 60
UHF GAIN dB 75
SELECTABLE FILTERS BANDWIDTH AUTO - NARROW/STANDARD/WIDE
OUTPUT LEVEL RANGE dBµV 99... 119
FILTER LEVEL ADJUSTER dB -5... +5 (1dB step)
FILTER OFFSET ADJUSTER KHz -500... +500 (125KHz steps)
UHF ADJUSTABLE SLOPE dB 0... -5
VHF ADJUSTABLE OUTPUT dB 0... 10 (1 dB step)
MAX TOTAL VHF-UHF OUTPUT LEVEL dBμV 126 DIN 45004B
INPUTS REMOTE POWER 12V / 24V 100 mA
RETURN LOSS IN/OUT dB >12
TEST OUTPUT 1 (-30 dB)
AMPLIFIER POWERING 100...240VAC 50/60Hz (External power supply 15VDC / 1,25A)
MAX AMPLIFIER CONSUMPTION W10,50
MAX AMPLIFIER CONSUMPTION + REMOTE POWER W12,50
OPERATING TEMPERATURE °C -5... 50
DIMENSIONS mm 192 x 217 x 37


Installation is only permitted in dry rooms and on a non-ammable surface.
Ensure that there is adequate air circulation.
Product complies with CE marking requirements
Symbol indicating earth terminal
RoHS 2011/65EU compliant product.
Symbol indicating that the supplied mains power supply complies with the safety
requirements for class II devices.
Pursuant to Article 24of Legislative Decree No. 49 of 14 March 2014 “Implementation
of Directive 2012/19/EU on waste electrical and electronic equipment (WEEE)”. The
crossed-out wheelie bin symbol on the equipment or its packaging indicates that
the product at the end of its useful life must be collected separately from other
waste for proper treatment and recycling.
CAUTION To avoid risk of re or electrocution, do not open the mains power supply provided.
WARRANTY YEARS
AUTO
TUNING
The DSP40pro+ amplier is covered by an extended 5-year warranty from the date
of manufacture.
The UHF inputs are protected by SAW technology lters against 5G and 4G Lte
interference.
The DSP40pro+ amplier can also be programmed via a free graphic application
available for Android OS.
The AUTO-TUNING scanning function serves to speed up the programming
procedure by automatically storing DVB-T/T2 Channel’s.
Description of symbols and electrical safety
Product icons description
LEM USB
Package Contents
01 DSP40pro+ programmable amplier
01 Power supply YS25-1501250 (100... 240VAC 50/60Hz 0.5A - 15VDC 1.25A)
08 Dowels 6x30mm with screws 4.5x40mm
01 User Manual

Installation warnings
- Use only the supplied power supply unit.
- To ensure adequate cooling and ventilation, the DSP40pro+ control unit and power supply unit
must be securely xed to a vertical wall.
- To avoid the risk of re or electrocution, do not expose the products to rain or moisture.
- Products must not come into contact with water or be wetted by liquids.
- Do not place products near heat sources or in places with moisture.
- In the case of installation in a cabinet or recessed compartment, provide adequate ventilation and
observe the minimum distances given in the drawing below.
- Prepare the mains connection in accordance with the regulations in force in the country of installation
and in such a way that the power supply to the control unit can be easily disconnected.
Power supplier
YS25-1501250
100-240VAC
15VDC-1,25A
Input (1) UHF
Input (2) UHF Input (3) VHF/UHF
Input (4) UHF/DAB
MATV output
Earth terminal
Test -30dB
Input (6) AUX
(40... 862MHz)
Input (5) FM
USB type B
LCD display
INPUT
40-860MHz
FM
USB
MATV
OUT
TEST
-30dB
UHF
1
DC
UHF
2
DC
VHF/UHF
3
DC
UHF/DAB
4
DC
DSP40
PRO+
Digital Signal Processor
USER GUIDE
DC15V
DSP 40PRO+
. .
Connections and start-up
1) Proceed with the connection of the coaxial input and output cables equipped with their own earth
terminal block.
2) Close the inputs with 75Ω terminations (code RCS75).
3) Connect the power supply to the mains socket only after all other connections have been made.
4) Always use the test output for connecting measuring instruments.

UHFFM UHF UHF DAB
MATV
Test
INPUT
40-860MHz
FM
USB
MATV
OUT
TEST
-30dB
UHF
1
DC
UHF
2
DC
VHF/UHF
3
DC
UHF/DAB
4
DC
DSP40
PRO+
Digital Signal Processor
USER GUIDE
DC15V
DSP 40PRO+
. .
PSU
UHF
AUX
FM
DVB-S/S2 > DVB-T/T2
Transmodulators
SAT UHF UHF DAB
MATV
Test
INPUT
40-860MHz
FM
USB
MATV
OUT
TEST
-30dB
UHF
1
DC
UHF
2
DC
VHF/UHF
3
DC
UHF/DAB
4
DC
DSP40
PRO+
Digital Signal Processor
USER GUIDE
DC15V
DSP 40PRO+
. .
LNBPOWER
CHANNELOUT SET USB
TUNERLOCK
POWERON
LNBPOWER
CHANNELOUT SET USB
TUNERLOCK
POWERON
LNBPOWER
CHANNELOUT SET USB
TUNERLOCK
POWERON
LNBPOWER
CHANNELOUT SET USB
TUNERLOCK
POWERON
LNBPOWER
CHANNELOUT SET USB
TUNERLOCK
POWERON
LNBPOWER
CHANNELOUT SET USB
TUNERLOCK
POWERON
PSU
Application examples

Description of display use
- To activate the display, briefly press the ⏎ key.
- To access the menus, press and hold the ⏎ key for 3 seconds.
- To make a value in the display editable, position the function selector > using the navigation keys
∇ ∆. Pressing ⏎ will activate the pointer under the data, which can be modified with ∇ ∆ keys. To
confirm the change press ⏎.
Menu browsing
keys
Confirmation
key
Pointer to
scroll figures
Function
selector
Input
channel
Output
channel
21->21S 065
>32->43S
Input
level dBµV
Note: after 3 minutes of inactivity the display switches off but the menu remains open on the last selected
function. To resume press any key
Device Programming
The DSP40pro+ programmable amplifier can be configured in two different ways:
1) using the display and navigation keys integrated into the control unit.
2) using the LEM USB application for Android smart phones, which can be downloaded
free of charge from the Google Play Store.
To return to the main level menu from any sub-menu, simultaneously press the ∇ ∆

TUNING
AUTO MAN
>LTE:5G
THRES:055dB
>DC:12V
DC IN1:OFF
>THRES:055dB
START
>START
EXIT
Automatic Channel Programming
To speed up the programming process, you can use the AUTO-TUNING function. When this
function is activated, the DSP40pro+ amplifier will automatically scan the inputs (1; 2; 3; 4) and
store only DVB-T/T2 signals with a level equal to or higher than the THRES threshold (factory
setting 55dBµV).
TUNING
AUTO MAN
To start the AUTO-TUNING procedure select AUTO and
press ⏎. For best results, you will be asked to confirm some
parameters before starting the scan.
>LTE:5G
THRES:055dB
Select START to start automatic channels scanning. The
duration of the AUTO-TUNING procedure depends on the
number of channels received from the connected antennas.
OUTPUT
>LEV:110dBuV
Once the AUTO-TUNING procedure is complete, the display
will show the total output level calculated according to the
number of channels found in the scan. To confirm and complete
the procedure press the ⏎ key. If you wish to change the value
of the output level, use the ∇ ∆ keys and confirm by pressing
the ⏎ key.
Note:
An output level higher than that obtained
automatically can lead to a degradation
of signal quality.
>DC IN1:OFF
DC IN2:OFF
>DC:12V
DC IN1:OFF
>THRES:055dB
START
>START
EXIT
TUNING
WAIT
Choose 12V or 24V for the remote power supply that will be
provided by the inputs that will be activated in the next step.
Switch on the remote power supply on the inputs that are to
supply an active antenna or an external amplifier.
Selecting 5G will activate the Lte4/5G interference protection
SAW filters and the UHF channel search range will be limited
between E21 and E48. Selecting OFF will disable Lte5G
protection and extend the search to the entire UHF band
(E21... E69).
REMOTE POWER SUPPLY
LTE FILTER ACTIVATION
The 55dBµV factory threshold is optimal for most situations,
but it is possible to change it.
THRES > 55dB= lower search sensitivity
THRES< 55dB= higher search sensitivity
THRESHOLD LEVEL
AUTO-TUNING START
ERROR
OVERCURRENT!
The presence of a short circuit or overload at the
inputs is signalled by the flashing red light.
green POWER LED and the display.

TUNING
AUTO MAN
IN (1) UHF
IN (2) UHF
IN (3) V/UHF
IN (4) UHF
IN (4) DAB
OUTPUT
IN (5) FM
IN (6) AUX
ADVANCED
EXIT
RESET
PASSW:000
>LTE:5G
DC:12V
>BW:MAN
THRES:055dB
>FAST:ON
MONITOR:OFF
>SRNBR:12345
>AMPLI:MID
DC:OFF
>21->21S 065
ADD 1 CH
AMPLI:MID
>ADD 1CH
>AMPLI:MID
DC:OFF
>21->21S 065
ADD 1 CH
AMPLI:MID
>ADD 1CH
>AMPLI:MID
DC:OFF
>21->21S 065
ADD 1 CH
AMPLI:MID
>ADD 1CH
>AMPLI:MID
DC:OFF
>21->21S 065
ADD 1 CH
AMPLI:MID
>ADD 1CH
:ON
>AMPLI:MID
IN (5) FM
>ATTEN:-15dB
IN (6) AUX
>ATTEN:-15dB
LEV:119dBuV
>SLOPE:05dB
SLOPE:05dB
>VHF:-00dB
ARE U SURE?
YES NO
OP
EXECUTED
ARE U SURE?
YES NO
Manual Programming
INPUTS menu
- Remote power supply (0/12/24VDC)
- Input amplifiers (OFF - MID - HIGH)
- Select filters/channels and carry out conversions
- Assign the most suitable filter type (NARROW - STANDARD - WIDE)
- Display the input level of a received signal (Channel)
OUTPUT menu
- Output level
- UHF Slope
- VHF Attenuation
ADVANCED Menu
- Password
- Lte 5G filter
- Filter type management (Automatic or manual)
- THRES function (level threshold)
- FAST function
- MONITOR function
- Serial number

TUNING
AUTO MAN
To start manual programming, select MAN using the ∇ key and
press ⏎.
IN (1) UHF
Press ∇ to position function switch > to ADD 1CH and
press ⏎. To select the channel number use the ∇ ∆ keys;
to confirm that the output channel is the same as the input
channel press ⏎ twice.
To enable remote feed from input (1) press ⏎ and use the ∇
∆ keys to select ON / OFF and confirm by pressing ⏎ again.
Press ∇ to set function switch > to AMPLI and press ⏎ and
use the ∇ ∆ keys to select OFF/MID/HIGH confirm by pressing
⏎ again.
>DC:OFF
IN (1) UHF
>AMPLI:MID
DC:OFF
>21->21S 065
ADD 1 CH
INGRESSO (1) UHF
TELEALIMENTAZIONE
INPUT AMPLIFIER
CHANNEL FILTER
To set input parameters (1) press ⏎.
The 12/24V selection can be found in the ADVANCED menu
INPUT SIGNAL LEVEL AMPLIFIER
Higher than 85dBµV OFF
Between 55dBµV and 85dBµV MID
Less than 55dBµV HIGH
AMPLI:MID
>ADD 1CH
>21->34S 065
ADD 1 CH
Menu description
To convert a Channel to a different channel from the one
received as input, place the pointer .... under the output filter
and select the channel number using the ∇ ∆ keys, press ⏎
to confirm.
Channel CONVERSION
LTE 5G FILTER INPUT CH. OUTPUT CH.
ON E21÷E48 E21÷E69
OFF E21÷E69 E21÷E69
LTE 5G filter management in ADVANCED menu
>21->21S 065
ADD 1 CH

IN (2) UHF
INPUT (2) UHF
To set the input parameters (2) press ⏎ and access the
menu. For programming, follow the instructions described
for INPUT (1) UHF.
IN (3) V/UHF
INPUT (3) VHF/UHF
To set input (3) parameters, press ⏎ to access the menu.
For programming, follow the instructions described for
INPUT (1) UHF
OVERLAPPING FILTERS
The overlapping of two or more filters with the same output
channel is indicated by the symbol *.
23->23S*065
>23->23S*065
IN (4) UHF
INPUT (4) UHF To set input (4) parameters, press ⏎ to access the menu.
For programming, follow the instructions described for
INPUT (1) UHF
IN (4) DAB
INPUT (4) DAB To activate the input filter for the DAB band select ON. The
DAB filter has its own amplifier that can be set to three levels.
:ON
>AMPLI:MID
AMPLIFIER GAIN
OFF -8 dB
MID 0 dB
HIGH +15 dB
Note: Activating the DAB filter does not exclude the possibility of process UHF channels from the
same input so COMBO DAB-UHF antennas can be used.
CH DELETED Select a channel filter or conversion and press ⏎ for 5
seconds to delete.
DELETE FILTER
FILTER DESCRIPTION USE SUGGESTION
NNarrow Adjacent
SStandard Not-adjacent
WWide Not-adjacent low quality
>21->21S 065
ADD 1 CH
FILTER BANDWITDH
To manually assign a filter bandwidth press ⏎ again and use the ∇ ∆
keys to choose the most suitable filter.
Note: The presence of the letter Aindicates that automatic filter
management has been selected in the ADVANCED menu. To
change it to manual access the ADVANCED menu and select
BW: MAN.
LTE 5G FILTER INPUT CH. OUPUT CH.
ON E5÷E13/E21÷E48 E5÷E13/E21÷E69
OFF E5÷E13/E21÷E69 E5÷E13/E21÷E69
LTE 5G filter management in ADVANCED menu

OUTPUT
Press ∇ to select the OUTPUT menu and confirm with ⏎ to
access the amplifier output level setup.
To set the output level, press ⏎ and use the ∇ ∆ keys to change
the numerical value. To confirm, press ⏎ again.
OUTPUT LEVEL
To correct the slope of the output, set the pointer > to
SLOPE and press ⏎, use the ∇ ∆ keys to change the value
and press ⏎ to confirm.
SLOPE
OUTPUT
>LEV:119dBuV
LEV:119dBuV
>SLOPE:05dB
SLOPE:05dB
>VHF:-00dB
To change the VHF level output, select VHF and press ⏎; use
the ∇ ∆ keys to change the value and press ⏎ to conrm.
VHF OUTPUT LEVEL
IN (5) FM
INPUT (5) FM
Input (5) is dedicated to the FM radio band. To adjust the input
attenuation press ⏎ and use the ∇ ∆ keys to set the desired
level.
IN (5) FM
>ATTEN:-15dB
IN (6) AUX
INPUT (6) AUX
Input (6) is wideband from 40 to 860Mhz and is ideal for
amplifying signals generated by A/V modulators or
DVB- S/S2 > DVB-T/T2 transmodulation systems. To adjust
the input attenuation press ⏎ and use the ∇ ∆ keys to set
the desired level.
IN (6) AUX
>ATTEN:-15dB
To return to the main level menu from any submenu, press and hold the ∇ ∆

ADVANCED
ADVANCED SETTINGS
PASSW:000
>LTE:5G
Press ⏎ and use the ∇ ∆ keys to enable or disable the Lte5G
SAW filters, press ⏎ to confirm.
LTE:5G
>DC:12V
To set the DC voltage press ⏎ and use the ∇ ∆ keys to select
12V or 24V voltage confirm by pressing ⏎.
DC:12V
>BW:MAN
Select PASSW, press ⏎ and use the ∇ ∆ keys to choose the
numerical value of the first digit on the right and confirm with
⏎. For the next two digits, repeat the operation and press ⏎
to confirm.
DC:12V
>BW:AUTO
The THRES value determines the sensitivity of the
AUTO- TUNING scan and the intervention threshold of the
MONITOR function.
Lte 5G FILTER
REMOTE POWERING
PROTECTION PASSWORD
THRESHOLD LEVEL
PASSW:000
>LTE:OFF
BW:AUTO
>THRES:055dB
ADVANCED
>PASSW:000
Code 0 0 0 equals no password protection
The selected remote supply voltage will be the same for all inputs.
FILTERS BANDWIDTH
In MAN (manual) mode three different filters (N - S - W) will be
selectable in the INPUT menus. If AUTO is set, the filters will
be assigned automatically.
Activation of the FAST function reduces the adjusting time of
the CAG (automatic gain control). This function is useful in the
presence of unstable channels with sudden changes in their
level.
FAST FUNCTION
THRES:055dB
>FAST:ON
Lte 5G FILTER INPUT CHANNELS
ON E21÷E48
OFF E21÷E69

The number series to the right of SRNBR represents the serial
number of the product.
MONITOR:OFF
>SRNBR:12345
To end the programming procedures select EXIT pressing ⏎
and select with ∇ ∆ YES press ⏎ to confirm. If you wish to
continue programming select NO and confirm with ⏎.
EXIT
RESET
If you wish to delete all settings and restore the control unit
to factory state, select YES and confirm ⏎. The display
will show the message OP EXECUTED to confirm the
successful cancellation operation.
ARE U SURE?
YES NO
OP
EXECUTED
RESET
SERIAL NUMBER
EXIT
Activation of the MONITOR function, a continuous cyclic
check of all the programmed filters, disabling those that are
not affected by the transmission of a channel. The switch-
off threshold is set by the THRES value described in the
THRESHOLD LEVEL function.
MONITOR FUNCTION
FAST:OFF
>MONITOR:OFF
ARE U SURE?
YES NO
To return to the main level menu from any submenu, press and hold the ∇ ∆

Requirements
The DSP40pro+ can also be programmed by the LEM USB App available for Android
smartphones, which can be downloaded free of charge from the Google Play portal.
To check whether your device’s USB port supports OTG (On The Go) mode, please refer to the
user manuals of your smartphone/tablet, failing which you can check OTG compatibility with a
free APP called USB OTG Checker that can be downloaded from the Google Play portal.
A USB-OTG cable or adapter is required to connect and programme the DSP40pro+
Android SmartPhone Programming
Note: the channel manual level adjustment functions LEVEL ADJ and offset FREQ ADJ are
accessible only on the LEM USB APP.
Setup
1 Power up the control unit and wait for the LCD display to show DSP40 PRO+.
2 Connect the USB port of your Android device with the USB-B port integrated in the DSP40pro+
control unit using the appropriate USB-OTG cable.
3 If the connection procedure was successfully completed, the LEM USB application will start
automatically allowing all programming operations.
GET IT ON
GET IT ON
LEM USB


Label with serial and tracking data
Model Serial # Manuf.
Week
Manuf.
Year
HW
Rel.
FW
Rel.
LEM ELETTRONICA srl
Table of contents
Other Lem Elettronica Signal Processor manuals