Lennox Hearth Products Elite E260 User manual

1
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
BLOWER KITS
COUNTRY COLLECTION™ WOOD FIREPLACE INSERTS
P/N 506033-36
Rev. NC, 11/2009
HEARTH PRODUCTS
KITS AND ACCESSORIES
KIT CONTENTS
1 ea. Blower Assembly
1 ea. Instruction Sheet
TOOLS NEEDED
5/32 Allen Wrench Or T Handle Wrench
9/16” Socket Wrench
9/16” Open End Wrench
5/16” Open End Wrench
Large Flat Head Screwdriver
FPO
INSTALLATION INSTRUCTIONS FOR INSTALLING BLOWER
KITS FOR USE WITH COUNTRY COLLECTION™ MODELS E260, C260, C310,
C160, CA160, C210 AND CA210 WOOD FIREPLACE INSERTS
WARNINGS
The blower must be plugged directly into a properly
groundedthree-prongreceptacle,120VAC,60Hz,single
phase. Do not cut or remove the grounding prong from
this plug. Do not route power cord under or in front of
appliance.
Installation must be in accordance with National Elec-
trical Code, ANSI/NFPA 70 - latest edition. In Canada,
the current CSA C22-1 Canadian Electrical Code - latest
edition.
DANGER: Disconnect power before servicing blower.
Figure 1 - Kit Contents
GENERAL INFORMATION
This optional blower kit can be installed to improve hot air distribution
throughout the room.
The room air circulation blower kit comes with a
variable speed control (rheostat) and an snap switch which will provide
automatic thermal activation of the blower, when desired (see Blower
Operation on Page 4).
If you encounter any problems, need clarification of these instructions or
are not qualified to properly install this kit, contact your local distributor
or dealer.
Read this instruction sheet in its entirety before beginning the installa-
tion.
ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND
OPERATION MANUAL PROVIDED WITH THE APPLIANCE APPLY TO
THESE INSTRUCTIONS.
SHUT DOWN THE INSERT AND ALLOW IT TO COMPLETELY COOL
BEFORE PROCEEDING.
BLOWER KITS FOR MODELS E260, C260, AND C310
H7912 WLINS-BLWR-B-SS Blower Insert Black
H7913 WLINS-BLWR-G-SS Blower Insert Gold
H7914 WLINS-BLWR-N-SS Blower Insert Nickle
H7915 WLINS-BLWR-BN-SS Blower Insert Brushed Nickle
H7916 WLINS-BLWR-BG-SS Blower Insert Brushed Gold
BLOWER KITS FOR MODELS C160, CA160, C210 AND CA210
Cat. No. Model Description
H7907 WSINS-BLWR-B-SS Blower Insert Black
H7908 WSINS-BLWR-G-SS Blower Insert Gold
H7909 WSINS-BLWR-N-SS Blower Insert Nickle
H7910 WSINS-BLWR-BN-SS Blower Insert Brushed Nickel
H7911 WSINS-BLWR-BG-SS Blower Insert Brushed Gold

2NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 2
INSTALLATION INSTRUCTIONS
Install Blower Assembly
Step 1. Remove the contents from the blower kit.
Step 2. Place grommet with power cord into lower slot on desired side
of insert. See Figure 2.
Step 6. Visually inspect and confirm that the snap switch is flat against
the bottom side of the ash lip.
Step 7. After installing blower, If snap switch height adjustment is nec-
essary, remove blower, and with a 5/16” wrench, loosen snap
switch bracket nuts, and adjust up or down. When complete,
re-tighten bracket nuts and re-install blower.
Step 3. Loosen the two blower mounting bolts below ash lip on both
sides of front of insert, with 9/16” wrench. See Figure 3.
Figure 3
Step 4. Notice the corresponding slots on the rear of blower cage. See
Figure 4.
Figure 4
Step 5. Insert blower under the ash lip making sure that the slots in
the blower housing line up to the left side of bolts. Gently slide
blower housing from left to right over the loosened bolts until
you feel it hit a solid stop and the housing is centered under the
ash lip of the insert. See Figure 5.
Figure 5
Figure 6
Blower Mounting Slot

3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Step 9. Re-check snap switch position to ensure good surface con-
tact. Surface contact is critical to the optimal operation of the
switch.
Step 10.Plug the power cord into a grounded 120 VAC receptacle. Do not
route the power cord under the appliance or allow it to come in
contact with any surface of the appliance.
Figure 7
Step 11. INSTRUCTIONS FOR MODEL E260 ONLY -
a. Remove the existing draft rod knob.
b. Install the supplied draft rod extension through the bracket at-
tached to the bottom of the left side hearth plate, making sure
the end without the grooves is toward the insert body. Thread
the coupling nut on the end closest to the insert body and then
thread the coupling nut on the rod from the insert.
c. Locate the blower and blower extensions (see Figure 8). Slide
the blower partially under the hearth plate. Run the blower
cord through the slot in the blower housing extension on the
appropriate side. Slide the left housing extension over the draft
rod on the left side and slide the right housing using the method
described below (the ends without the cord slots attach to the
blower housing). Now slide the blower assembly under the
hearth plate and center it.
Figure 8
Use the adhesive strip on the inside of the side trim pieces. Be sure
to position the side trim pieces exactly as desired then slide the trim
piece out just enough to remove the cover strip on the adhesive and
press the trim piece tightly against the blower and hold for 30 seconds.
Step 8. Tighten bolts. See Figure 7.

4
Printed in U.S.A. © 2009 Lennox Hearth Products
P/N 506033-36 Rev. NC 11/2009
Lennox Hearth Products reserves the right to make changes at any time, without notice, in
design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
1110 West Taft Avenue • Orange, CA 92865
Blower Operation
The blower can be operated manually or automatically (blower will
turn on when the insert is hot and turn off when the insert is cool).
The rocker switch on the control panel allows you to select between
manual operation or automatic operation as follows (see Figure 10):
MANUAL OPERATION: Turn rocker switch to the manual position (up)
and adjust rheostat knob to the desired speed. The blower will have to
be manually turned “OFF” by rotating the rheostat knob counterclock-
wise until it clicks.
AUTO OPERATION: Turn rocker switch to the “AUTO” position and
the rheostat to the ON position (rotate rheostat knob clockwise until it
clicks). When the insert warms up, the blower will automatically turn
on (adjust rheostat knob to the desired speed setting). When the insert
cools down, the blower will automatically turn off.
Rheostat Operation - The highest blower speed is obtained by turning
the rheostat knob clockwise until it clicks “ON”, then rotate towards
“HIGH” to increase blower speed. Rotate the knob clockwise for a
lower speed. To turn off, continue to rotate the knob counterclockwise
until it clicks “OFF.”
Figure 9 - Wiring Schematic
Figure 10 - Blower Controls
Blower Speed Control
Knob (rheostat)
Manual / Auto
Rocker Switch
ROOM AIR
BLOWER
SPEED
CONTROL/OFF
TWO POSITION
SWITCH
MANUAL/TEMPERATURE
AUTO-RESET
TEMPERATURE
SWITCH N/O
POWER CORD
RED
RED
RED
YLW
BLK
WHT
GRN
NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE
N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN
= FEMALE DISCONNECT
= MALE DISCONNECT
= STUD CONNECTION
Blower Operation Guidelines
While in auto operation mode, the blower will turn off and on based on the
temperature of the stove. Auto operation ensures there is sufficient heat
build-up to warm the air being moved by the blower before the blower is
turned on. Likewise, when the stove cools off, the blower is turned off
to prevent circulating cool air. Depending on the size and intensity of the
fire it may be necessary to adjust the fan speed accordingly to ensure un-
interrupted fan operation. For example a small fire may require a slower
fan speed to keep the heat output by the fan consistent. If the blower is
operated in manual mode, it may be necessary to adjust the blower speed
as the fire begins to burn down and the stove is no longer hot enough to
effectively heat the air moved by the blower. If the air coming from the
blower feels cool, one should either decrease the blower speed or stoke
the fire to build up more heat.
Other manuals for Elite E260
1
This manual suits for next models
7
Popular Accessories manuals by other brands

Kogan
Kogan KAPWB20LAPA user manual

LST
LST LAB48 Specification sheet

Somatic Vision
Somatic Vision Alive iFeel User guide supplement

Decagon Devices
Decagon Devices Dielectric Leaf Wetness Sensor Owner's/operator's manual

RADWAG
RADWAG PUE HY10 user manual

American Standard
American Standard Culinair 7412.100.340 Specification sheet