Lenze ESV112N02SFC User manual

SMVector Additional I/O Module
Installation and Operation Manual

This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used
in conjunction with the SMVector Operating Instructions (Document SV01) that shipped with the drive. These
documents should be read in their entirety as they contain important technical data and describe the installation
and operation of the drive.
NOTE
To use the I/O Module with SMVector drives rated at 0.33 to 10 HP (0.25 to 7.5 kW) requires
that the drive has software version 3.0 or higher. The software version can be found in
the SMVector drive diagnostic parameter P501. To use the I/O Module options the value
displayed in P501 must be 3.00 or higher.
SMVector drives rated at 15 HP (11.0 kW) and higher all support the I/O options models so
there is no need to verify the value in P501.
© 2008 Lenze AC Tech Corporation
No part of this documentation may be copied or made available to third parties without the explicit written approval
of Lenze AC Tech Corporation. All information given in this documentation has been carefully selected and tested
for compliance with the hardware and software described. Nevertheless, discrepancies cannot be ruled out. Lenze
AC Tech does not accept any responsibility nor liability for damages that may occur. Any necessary corrections will
be implemented in subsequent editions.
About These Instructions

i ALSV01B
Contents
1 Safety Information .............................................................................................................1
1.1 Warnings, Cautions and Notes ..............................................................................1
1.1.1 General ....................................................................................................1
1.1.2 Application ...............................................................................................1
1.1.3 Installation ...............................................................................................1
1.1.4 Electrical Connection ................................................................................2
1.1.5 Operation .................................................................................................2
2 Introduction .......................................................................................................................3
2.1 Module Overview ..................................................................................................3
2.2 Module Specification ............................................................................................3
2.3 Module Identification Label ...................................................................................3
3 Installation ........................................................................................................................4
3.1 Mechanical Installation .........................................................................................4
3.2 Module Terminal Block .........................................................................................5
3.3 Electrical Installation .............................................................................................6
3.3.1 Terminal Description ................................................................................6
3.3.2 Module Wiring ..........................................................................................6
4 Commissioning .................................................................................................................7
4.1 Network Parameters (P400) ..................................................................................7
4.2 Additional I/O Module Parameters .........................................................................8
4.3 Display .................................................................................................................10

1 ALSV01B
Safety Information
1 Safety Information
1.1 Warnings, Cautions and Notes
1.1.1 General
Some parts of Lenze controllers (frequency inverters, servo inverters, DC controllers) can be live, moving
and rotating. Some surfaces can be hot.
Non-authorized removal of the required cover, inappropriate use, and incorrect installation or operation
creates the risk of severe injury to personnel or damage to equipment.
All operations concerning transport, installation, and commissioning as well as maintenance must be
carried out by qualified, skilled personnel (IEC 364 and CENELEC HD 384 or DIN VDE 0100 and IEC report
664 or DIN VDE0110 and national regulations for the prevention of accidents must be observed).
According to this basic safety information, qualified skilled personnel are persons who are familiar with
the installation, assembly, commissioning, and operation of the product and who have the qualifications
necessary for their occupation.
1.1.2 Application
Drive controllers are components designed for installation in electrical systems or machinery. They are
not to be used as appliances. They are intended exclusively for professional and commercial purposes
according to EN 61000-3-2. The documentation includes information on compliance with EN 61000-3-2.
When installing the drive controllers in machines, commissioning (i.e. the starting of operation as directed)
is prohibited until it is proven that the machine complies with the regulations of the EC Directive 2006/42/
EC (Machinery Directive); EN 60204 must be observed.
Commissioning (i.e. starting drive as directed) is only allowed when there is compliance to the EMC
Directive (2004/108/EC).
The drive controllers meet the requirements of the Low Voltage Directive 2006/95/EC. The harmonised
standards of the series EN 50178/DIN VDE 0160 apply to the controllers.
The availability of controllers is restricted according to EN 61800-3. These products can cause
radio interference in residential areas. In the case of radio interference, special measures may be
necessary for drive controllers.
1.1.3 Installation
Ensure proper handling and avoid excessive mechanical stress. Do not bend any components and do not
change any insulation distances during transport or handling. Do not touch any electronic components
and contacts. Controllers contain electrostatically sensitive components, which can easily be damaged by
inappropriate handling. Do not damage or destroy any electrical components since this might endanger
your health! When installing the drive ensure optimal airflow by observing all clearance distances in the
drive's user manual. Do not expose the drive to excessive: vibration, temperature, humidity, sunlight, dust,
pollutants, corrosive chemicals or other hazardous environments.

ALSV01B 2
Safety Information
1.1.4 Electrical Connection
When working on live drive controllers, applicable national regulations for the prevention of accidents (e.g.
VBG 4) must be observed.
The electrical installation must be carried out in accordance with the appropriate regulations (e.g.
cable cross-sections, fuses, PE connection). Additional information can be obtained from the regulatory
documentation.
The regulatory documentation contains information about installation in compliance with EMC (shielding,
grounding, filters and cables). These notes must also be observed for CE-marked controllers.
The manufacturer of the system or machine is responsible for compliance with the required limit values
demanded by EMC legislation.
1.1.5 Operation
Systems including controllers must be equipped with additional monitoring and protection devices according
to the corresponding standards (e.g. technical equipment, regulations for prevention of accidents, etc.).
You are allowed to adapt the controller to your application as described in the documentation.
DANGER!
• After the controller has been disconnected from the supply voltage, do not touch the live
components and power connection until the capacitors have discharged. Please observe
the corresponding notes on the controller.
• Do not continuously cycle input power to the controller more than once every three minutes.
• Close all protective covers and doors during operation.
WARNING!
Network control permits automatic starting and stopping of the inverter drive. The system design
must incorporate adequate protection to prevent personnel from accessing moving equipment
while power is applied to the drive system.
Table 1: Pictographs used in these instructions
Pictograph Signal word Meaning Consequences if ignored
DANGER! Warning of Hazardous Electrical
Voltage.
Reference to an imminent danger
that may result in death or serious
personal injury if the corresponding
measures are not taken.
WARNING! Impending or possible danger
for persons
Death or injury
STOP! Possible damage to equipment Damage to drive system or its
surroundings
NOTE Useful tip: If observed, it will
make using the drive easier

3 ALSV01B
Introduction
2 Introduction
This manual provides installation and operational data specific to the Additional I/O Module for the SMVector
series inverters. This manual is a supplement (not a substitution for) the standard SMVector - Frequency
Inverter Operating Instructions (document number SV01).
This document assumes that the reader has a working knowledge of the standard SMVector Frequency
Inverter and has familiarity with the programming and operation of the SMVector Frequency Inverter. Please
consult the SMVector - Frequency Inverter Operating Instructions (SV01) for more details.
2.1 Module Overview
The Additional I/O Module is available in two configurations (ESVZAL0, ESVZAL1) for use with the SMVector
Frequency Inverter. The modules are intended to supplement the standard I/O functions available in the
SMVector inverter.
The I/O module fits into the SMVector inverter terminal cover. This allows for easy field installation and
does not add to the overall size of the SMVector inverter.
SMVector inverters that are fitted with an additional I/O module option will no longer have the capability of
accommodating an optional communication module.
2.2 Module Specification
• P/N ESVZAL0: 1 programmable form C relay output.
• P/N ESVZAL1: 1 programmable form C relay output and 2 programmable digital inputs.
2.3 Module Identification Label
Figure 1 illustrates the labels on the SMV Additional I/O Module. The SMVector Additional I/O Module is
identifiable by:
• Label affixed to side of the module.
• Part Number ESVZALx on module label.
A: Module Type
B: Model Number
C: Lenze Order Number
D: Firmware Revision
E: Hardware Revision
SMV I/O
TYPE: ESVZAL1
ID-NO: 12345678
ESVZAL1-000XX1A10
A
B
C
D
E
Left-hand Label:
Module Data
Right-hand Label:
Ratings & Certifications
LISTED
Additional I/O ONLY
S/N: 123456789
Figure 1: Additional I/O Module Label

ALSV01B 4
Installation
3 Installation
3.1 Mechanical Installation
1. Ensure that for safety reasons the AC supply has been disconnected before opening the terminal
cover.
2. Insert the Additional I/O module in the terminal cover and securely “click” into position as illustrated
in Figure 2.
3. Wire the cables to the connector provided and plug the connector into the option module.
4. Align terminal cover for re-fitting, connect the module umbilical cord to the drive then close the cover
and secure, as shown in Figure 3.
13G 13F 21 20 19
7mm
<_ 2.8 mm²
(12-22 AWG)
0.5 Nm/ 4.5 lb-in
13G 13F 21 20 19
7mm
<_ 2.8 mm²
(12-22 AWG)
0.5 Nm/ 4.5 lb-in
Red wire and black wire
are present in the ESVZAL1
module. They are not
present in the ESVZAL0
module. Refer to wiring
instructions below.
Figure 2a: NEMA 1 (IP31) Installation Figure 2b: NEMA 4X (IP65) Installation
The ESVZAL1 I/O Option Module
contains 1 red wire and 1 black wire
that must be wired into the standard
SMVector Inverter terminal strip.
Connect the black wire to terminal #2.
Connect the red wire to terminal #11.
Refer to adjacent diagram.
1 2 5 6 25 411 13A 13B 13C 14 30 16 17
Black and Red wires from ESVZAL1 Module
Terminal Strip of Standard SMVector Inverter
Figure 2c: Wiring the ESVZAL1 I/O Module

5 ALSV01B
Installation
Figure 3: Re-Installing the Terminal Cover
3.2 Module Terminal Block
Table 2 identifies the terminals and describes the function of each. Figure 4 illustrates the Additional I/O 5
pole 5mm pluggable connector.
Table 2: Additional I/O Terminals
Terminal Function Description
19 Relay N.O.
20 Relay Common
21 Relay N.C.
13F Digital Input Available only on ESVZAL1
13G Digital Input Available only on ESVZAL1
13G
13F
212019
Figure 4: Additional I/O Connector

ALSV01B 6
Installation
3.3 Electrical Installation
3.3.1 Terminal Description
Table 3 contains each terminal's electrical specification and any parameter description associated with
that terminal.
Table 3: Additional I/O Module Specifications
Terminal Function Description
19 Relay N.O. Relay output configurable with P441, P144
AC 250 V / 3 A 17 DC 24 V / 2 A … 240 V / 0.22 A, non-inductive
20 Relay Common
21 Relay N.C.
13F Digital Input 13F configurable with P426
13G configurable with P427
Input Impedance = 4.3 kohm
The assertion level of Terminals 13F and 13G will match the assertion level of
the standard SMVector digital inputs 13A, 13B, 13C, etc…
Refer to the description of P120 and Terminal #4 in the SMVector - Frequency
Inverter Operating Instructions (SV01)
13G Digital Input
NOTE
For ESVZAL0:
Control and communications terminals provide reinforced insulation when the drive is connected to a power system
rated up to 300V between phase to ground (PE) and the applied voltage on terminals 19, 20 and 21 is less than 250
VAC between phase and ground (PE)
For ESVZAL1:
Control and communications terminals provide reinforced insulation when the drive is connected to a power system
rated up to 300V between phase to ground (PE) and the applied voltage on terminals 19, 20 and 21 is less than 150
VAC between phase and ground (PE)
Control and communications terminals provide basic insulation when the drive is connected to a power system
rated up to 300V between phase to ground (PE) and the applied voltage on terminals 19, 20 and 21 is less than 250
VAC between phase and ground (PE).
3.3.2 Module Wiring
Figure 5 illustrates the wiring of the ESVZAL0 and ESVZAL1 modules.
19 20
21
19 20
21
13F
13G
To SMVector Control
Terminal Strip TB#4
Figure 5a: ESVZAL0 Figure 5b: ESVZAL1
NOTE
To assert terminals 13F and 13G with external power
sources, refer to section 3.2.3 of the SMVector
Operating Instructions (SV01)

7 ALSV01B
Commissioning
4 Commissioning
4.1 Network Parameters (P400)
Code Possible Settings IMPORTANT
No. Name Default Selection
4Network Protocol 0 Not Active This parameter setting is based upon the
network or I/O module that is installed.
1 Remote Keypad
2 Modbus RTU
3 CANopen
4 DeviceNet
5 Ethernet
6 Profibus
7 Lecom-B
8 I/O Module
4Module Type Installed 0 0 No Module Installed Module type format: 0xAABC; Drive Display:
AA.B.C
AA = Module Type
B = Major revision
C = minor revision
1 Basic I/O (0x0100, 1.0.0)
2 RS485/Rem. Keypad (0x0200, 2.0.0)
3 CANopen (0x0300, 3.0.0)
11 PROFIBUS (0x1100, 11.0.0)
12 Ethernet (0x1200, 12.0.0)
40 Module Status 0 0 Not Initialized
1 Initialization: Module to EPM
2 Initialization: EPM to Module
3 Online
4 Failed Initialization Error
5 Time-out Error
6 Initialization Failed Module type mismatch P401
7 Initialization Error Protocol selection mismatch P400
40 Module Reset 0 0 No Action Returns module parameters 401…499 to the
default values shown in the manual
1 Reset parameters to default values
40 Module Timeout Action 0 0 No Fault Action to be taken in the event of a Module/
Drive Time-out.
Time is fixed at 200ms
STOP is by the method selected in P111.
1 STOP (see P111)
2 Quick Stop
3 Fault (F_ntF)
40 Current Network Fault 0 No Fault
1 F.nF1 NetIdle Mode
2 F.nF2 Loss of Ethernet I/O connection
3 F.nF3 Network Fault
4 F.nF4 Explicit Message Timeout
5 F.nF5 Overall Network Timeout
6 F.nF6 Overall Explicit Timeout
7 F.nF7 Overall I/O Message Timeout
40 Proprietary Manufacturer specific
40 … 9Module Specific Parameters Refer to the Communications Reference Guide
specific to the network or I/O module installed.
NOTE
Set P400 = 8 for the SMVector drive to communicate with the additional I/O module.