Leyton SHE-B-250S User manual

12
ATTENTIONS
Read these instructions completely and carefully.
INSTRUCTION MANUAL
SERIES: SHE-B-250S
Dimensions: (mm)
Specifications:
emiTyaleDtupnIdetaR.oNledoM
83
35 19
1500
20
Read the instruction carefully before installation,non-observance of this instruction may cause
damage to the fixture or hurt to human body. The installation must be carried out by a qualified
electrician in accordance with local or national codes.
Cut off the power supply before installation and maintenance !
Keep this instruction manual handy for future use.
Use only in indoor,dry location.Clean the product with a dry cloth.
The luminaire shall be mounted out of arm’s reach. The recommended installation height shall
be at least 2,5 meter (above the ground).”
L x W x H
100-240VAC Max.1A
Rated current
83x35x19mmSHE-B-250S
ta
8s(test location),
30s,1min,3min,5min,10min -20-50°C
PIR Sensor
SHE-B-250S
PIR Sensor
SHE-B-250S
blue blue
PIR Sensor
SHE-B-250S
Master
blue
PIR Sensor
SHE-B-250S
Slave
blue
Choose one of SHE-B-250S as the master and
turn its knob to "test". The indicator light of the
master will flash and turn off.
The indicator light of the slaver starts to flash
synchronously. Then turn the knob of the slaver to
"test" and the indicator light turns off, which means
the match setting completed.
Note: *When the sensor detects ambient light illumination >160lux, the sensor controller shuts off the auto-detect mode.
When the sensor detects ambient light illumination <80lux, the sensor controller starts the auto-detect mode.
1
23
Connect to power, turn the knob to "match" with screw driver, then the blue indicator light turns on.
How to Match 1:
Sensor
(Optinal) Dimensions in mm(inch) Hole opening
diameter(D) Day Light Detection Light Sensitivity*
Sensor 1:
T/SLF5.876.045
Sensor 2:
T/SLF5.876.019
20
Yes 80-160 lux
No
No
60VA AV08AV052AV08AV052
100VA250VA 150VA 250VA 150VA
AC 100V,50/60HZ
AC 240V,50/60HZ
Types of load
Range voltage
Incandescent
lamp/
HV-halogen lamp
Electronic
ballast
Inductance
ballast
Electronic
transformer LED driver
34
Time delay setting
Wiring Diagram:
L
N
AC
L N
Constant Voltage
LED Power Supply
thgiLDELthgiLDELthgiLDEL
SHE-B-250S
L N
Constant Voltage
LED Power Supply
SHE-B-250S
L N
Constant Voltage
LED Power Supply
SHE-B-250S
Wiring Diagram:
SHE-B-250S SHE-B-250S
blue blue
L
N
AC
L N
Constant Voltage
LED Power Supply
thgiLDELthgiLDELthgiLDEL
SHE-B-250S
L N
Constant Voltage
LED Power Supply
SHE-B-250S
L N
Constant Voltage
LED Power Supply
SHE-B-250S
1
How to Match 2:
Connect to power, turn the knob to "match" with screw driver, then the blue indicator light turns on.
2
Remove the plastic covering from controller
battery.
SHE-B-250S
Power on, Set the delay time with screw driver.
The delay time can be set to 8s ("test" location),30s,1min.,3min.,5min.,10min.
The indicator light starts to flash synchronously.
Then turn the knob other SHE-B-250S to "test"
and the indicator light turns off, which means
the match setting completed.
SHE-B-250S
blue
3
KZQ-8YKB
56
TOP VIEW
80°
GOOD SENSITIVITY POOR SENSITIVITY
1(39-3/8″)~2M(78-3/4″)
0.5(19-11/16″)~2.5M(98-7/16″)
SIDE VIEW
This part should be
parallel to the floor
This part should be parallel to the floor
Sensitivity: Highest
Fix position: 1-2m in height
1
2
3
The detection range for the
suspended installation:
Detection area
On/off:
Function
PIR Sensor :
Note: *When the sensor detects ambient light illumination >160lux, the sensor controller shutsoff the auto-detect mode.
When the sensor detects ambient light illumination <80lux, the sensor controller startsthe auto-detect mode.
On/Off8s(test location), 30s,
1min,3min,5min,10min
On/Off8s("test" location), 30s,
1min,3min,5min,10min
On/Off8s("test" location), 30s,
1min,3min,5min,10min
1. Switch on /off fast (<2S) for twice, the sensor controller goes into keeping the light on mode.(The lamp load
flickstwice once power on)
2. Power on again, wait for about 30 seconds, lamp load turnsoff, and the sensor controller goes into
auto-detect mode.

Popular Accessories manuals by other brands

inventum HN138i instruction manual

inventum

inventum HN138i instruction manual

Brüel & Kjaer Vibro AS - 030 instructions

Brüel & Kjaer Vibro

Brüel & Kjaer Vibro AS - 030 instructions

Solid State Logic SSL 2 manual

Solid State Logic

Solid State Logic SSL 2 manual

Favero FULL-ARM-05 user manual

Favero

Favero FULL-ARM-05 user manual

Orno OR-CR-255 quick start guide

Orno

Orno OR-CR-255 quick start guide

Rechner Sensors SW-600-M12/28-S operating instructions

Rechner Sensors

Rechner Sensors SW-600-M12/28-S operating instructions

XLAYER Plus Solar user guide

XLAYER

XLAYER Plus Solar user guide

CHI YUNIQUE 2.0 manual

CHI

CHI YUNIQUE 2.0 manual

MSA General Monitors S4000TH instruction manual

MSA

MSA General Monitors S4000TH instruction manual

river systems ET 12 user manual

river systems

river systems ET 12 user manual

Panasonic HG-C1030 instruction manual

Panasonic

Panasonic HG-C1030 instruction manual

Bogen ZPM-3 installation instructions

Bogen

Bogen ZPM-3 installation instructions

PRESONUS StudioLive 24 owner's manual

PRESONUS

PRESONUS StudioLive 24 owner's manual

Brunswick Sync Preinstallation manual

Brunswick

Brunswick Sync Preinstallation manual

VONMÄHLEN EVERGREEN VM-EVG-01 user manual

VONMÄHLEN

VONMÄHLEN EVERGREEN VM-EVG-01 user manual

Humboldt SmartRock HG-4040 manual

Humboldt

Humboldt SmartRock HG-4040 manual

Aqara T1 quick start guide

Aqara

Aqara T1 quick start guide

Westone TRU owner's manual

Westone

Westone TRU owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.