TABLE OF CONTENTS
17 OPERATION
17 Control Panel and Remote Control
18 Removing Condensation Buildup
3 SAFETY INSTRUCTIONS
3 IMPORTANT SAFETY INSTRUCTIONS
8 PRODUCT OVERVIEW
8 Key Parts and Components
9 INSTALLATION
9 Electrical Data
10 Before Installation the Air Conditioner
11 Preparing for Installation
11 Selection of Installation Location
12 Window Vent Panel and Extensions
13 Installation (Vertical)
15 Installation (Horizontal)
19 SMART FUNCTIONS
19 LG ThinQ Application
22 MAINTENANCE
22 Emptying the Water Collection Tank
22 Cleaning the Case
21 Smart Diagnosis
22 Cleaning the Air Filter
23 TROUBLESHOOTING
23 Before Calling for Service
23 Normal Sounds You May Hear
27 WARRANTY
10 Wireless Remote Control
TM
TABLE OF CONTENTS
2

SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always
read and follow all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or injure you and others.
All safety messages will follow the safety alert symbol and either the word WARNING or
CAUTION.
These words mean:
WARNING
You may be killed or seriously injured if you do not follow instructions.
CAUTION
You may be injured or cause damage to the product if you do not follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce
the chance of injury, and tell you what may happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING
injury to persons when using this product, follow basic precautions,
including the following:
INSTALLATION
Before use, the appliance must be properly installed as described in this manual.
Contact the authorized service technician for repair or maintenance of this unit.
Contact the installer for installation of this unit.
SAFETY INSTRUCTIONS EN
3
The following symbols are displayed on units.
This symbol indicates that this appliance uses a flammable refrigerant. If the refrigerant is
is leaked and exposure to an external ignition source, there is a risk of fire.
This symbol indicates that the Operation Manual should be read carefully.
This symbol indicates that a service personnel should be handling this equipment with
reference to the Installation Manual.
This symbol indicates that information is available such as the Operating Manual or
Installation Manual.

When the power cord is to be replaced, replacement work shall be performed by authorized
personnel only using only genuine replacement parts.
and authorized personnel only.
Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.
Always plug into a grounded outlet.
Do not under any circumstances, cut or remove the third (ground) prong from the power cord.
When installing or moving the appliance, be careful not to pinch, crush, or damage the power
cord.
Plug in the power plug properly.
Do not modify or extend the power cord.
Do not start/stop operation by plugging/unplugging the power cord.
If the cord/plug is damaged, have it replaced by an authorized service person using authorized
replacement parts.
Use a dedicated circuit.
Do not disassemble or modify the product.
Adhere to all industry recommended safety procedures including the use of long-sleeved gloves
and safety glasses.
Use care when unpacking and installing. The edges of the product may be sharp.
Disconnect the power cord or circuit breaker before installing or servicing the appliance.
Keep packaging materials out of the reach of children. These materials can pose a suffocation
risk to children.
Store and install the product where it will not be exposed to temperatures below freezing or
Do not install the unit in potentially explosive atmospheres.
exposed to outdoor weather conditions.
other appliance.
OPERATION
Use this appliance only for its intended purpose.
Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled,
or has missing or broken parts, including a damaged cord or plug.
Repair or immediately replace all power cords that have become frayed or otherwise damaged.
Do not use a cord that shows cracks or abrasion damage along its length or at either end.
Do not run cord under carpets or mats where it could be stepped on and damaged.
Keep the cord out from under heavy objects like tables or chairs.
Do not place the power cord near a heat source.
Do not use an adaptor or plug the product into a shared outlet.
Do not tamper with controls.
If you detect a strange sound, a chemical or burning smell, or smoke coming from the appliance,
unplug it immediately, and contact an LG Electronics Customer Information Center.
straight out from the outlet.
Do not grasp the power cord or touch the appliance controls with wet hands.
The air conditioner is not intended for use by young children or invalids without supervision.
Young children should be supervised to ensure that they do not play with the air conditioner.
SAFETY INSTRUCTIONS
4

If water enters the product, turn off the power at the main circuit, then unplug the product and call
for service.
If the product has been submerged, contact the LG Electronics Customer Information Center for
instructions before resuming use.
Unplug the product when unused for long periods.
Unplug the product before cleaning.
In the event of a gas leak (propane gas, etc.) do not operate this or any other appliance. Open a
window or door to ventilate the area immediately.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning the use of the appliance by a person responsible for
their safety.
To clean the interior, contact the LG Electronics Customer Information Center or dealer.
Using harsh detergents may cause corrosion or damage to the unit.
Do not use solvent-based detergent on the product. Doing so can cause corrosion or damage,
GROUNDING INSTRUCTIONS
The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with
a standard three-slot (grounding) wall power outlet to minimize the hazard of electric shock. The
sure the receptacle is properly grounded. DO NOT CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER PLUG.
- Situations when the appliance will be disconnected occasionally; Because of potential safety
hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an
adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from
most local hardware stores.
The large slot in the adapter must be aligned with the large slot in the receptacle to assure a
proper polarity connection.
Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the
appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded
to make sure the receptacle is properly grounded.
Disconnect the power cord from the adapter, using one hand on each. Otherwise, the adapter
ground terminal might break. Do not use the appliance with a broken adapter plug.
- Situations when the appliance will be disconnected often; Do not use an adapter plug in these
situations. Unplugging the power cord frequently can lead to an eventual breakage of the
ground terminal. The wall power outlet should be replaced by a three-slot (grounding) outlet
instead.
SAFETY INSTRUCTIONS 5EN

CAUTION
To reduce the risk of minor or moderate injury to persons, malfunction, or
damage to the product or property when using this product, follow basic
precautions, including the following:
INSTALLATION
Take care when installing the product that exhaust or condensation does not damage nearby
property.
Follow installation instructions exactly to avoid excessive vibration or water leakage.
OPERATION
This appliance is not intended for use as a precision refrigeration system. Do not use it for special
purposes such as maintaining pets, food, precision machinery, or art objects.
When installing or moving the appliance, be careful not to pinch, crush, or damage the power
cord.
Make sure the air inlet and outlet are free from obstructions.
Use a soft cloth to clean the appliance. Do not use waxes, thinners, or harsh detergents.
Do not step on or place heavy objects on top of the appliance.
Do not drink water drained from the appliance.
are used simultaneously.
Remove the batteries if the remote control is not to be used for an extended period of time.
Never mix different types of batteries, or old and new batteries for the remote control.
consult a doctor.
Do not recharge or disassemble the batteries.
MAINTENANCE
Never use strong cleaning agents or solvents when cleaning the air conditioner or spray water.
Use a smooth cloth.
SAFETY INSTRUCTIONS
6

REFRIGERANT (FOR R32 ONLY)
WARNING
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources (for
CAUTION
associated with older units. Please follow all precautions and advisories.
- Use caution while handling and prevent damage to unit. Do not put any holes into product for
any reason. This can cause damage to product and prevent unit from cooling.
- Maintenance and cleaning of unit should be performed by trained personnel. Failure to properly
clean unit can result in damage to the refrigeration system and or the electrical system.
- Make certain that all the air circulation/ventilation openings are free from obstruction.
-
warranties.
-
water heaters or furnaces. Also keep away from electric heaters. Damaged units should be
repaired before storage.
SAVE THESE INSTRUCTIONS
SAFETY INSTRUCTIONS EN
7

PRODUCT OVERVIEW
temperature, and
using the bottom drain port.
REMOTE CONTROLLER
Key Parts and Components
PRODUCT OVERVIEW
8
6
7
8

INSTALLATION
Electrical Data
Power cord may include a current interrupter
device. TEST and RESET buttons are provided
on the plug case. The device should be tested on
TEST button
and then the RESET button. If the TEST button
does not trip or if the RESET button will not stay
engaged, discontinue use of the air conditioner
for 120 V
Use Wall Receptacle Power Supply
Standard 120 V , 3-wire
grounding receptacle rated
15 A / 120 VAC / 60 Hz
Use 15 A,
time-delay fuse
or 15 A circuit
breaker.
WARNING
This appliance should be installed in
accordance with the National Electrical
Code.
Use of extension cords could cause serious
injury or death.
sihthtiwdrocnoisnetxenaesutonoD- portable air conditioner.
teltuo-itlumrosrotcetorpegrusesutonoD- adapters with this portable air conditioner.
Never push the TEST button during
operation. Doing so can damage the plug.
sihtesremmiro,yfidom,evomertonoD- plug. If this device trips, the cause should
be corrected before further use.
CAUTION
The conductors inside this cord are
surrounded by shields, which monitor
leakage current. These shields are not
grounded. Periodically examine the cord
for any damage. Do not use this product
in the event the shields become exposed.
Avoid shock hazard. This unit cannot be
user-serviced. Do not open the tamper-
resistant sealed portion. All warranties and
performance will be voided. This unit is not
intended to be used as an ON/OFF switch.
RESET
TEST
INSTALLATION 9EN

Doing so
are
they do
place the appliance near
Before Installation
the Air Conditioner
Wireless Remote Control
Inserting Batteries
If the display screen of the remote control begins
to fade, replace the batteries. Insert AAA (1.5 V)
batteries before using the remote control.
1Remove the cover on the back of the
remote control.
2Insert the new batteries and make sure that
the + and - terminals of the batteries are
installed correctly.
NOTE
New batteries are supplied with the air
conditioner for use in the remote control.
Do not use a rechargeable battery. Make sure
that the battery is new.
In order to prevent discharge, remove the
battery from the remote control if the air
conditioner is not going to be used for an
extended period of time.
Keep the remote control away from extremely
hot or humid places.
To maintain optimal operation of the remote
control, the remote sensor should not be
exposed to direct sunlight.
The remote control will not work properly if the
unit is exposed to direct light or there is any
obstacle between the unit and remote controller.
INSTALLATION
10

50 cm
50 cm
50 cm
NOTE
After installation, the Hose length is approximately
90 cm
or less for best performance.
Optional French Labels
Affix label L and M to Panel A if necessary.
English : Lock/Unlock, Indoor
French : Verrouiller/Déverrouiller, Intérieur
L M
INSTALLATION 11 EN
Basic Installation Materials Supplied
Shape Parts Name
Hose
Base mounting plate
(58 cm, 1 pcs)
Extension mounting
plate (40 cm, 1 pcs)
Extension mounting
plate (58 cm, 1 pcs)
Mounting plate
screws (4 pcs)
Adhesive short foam
weather seals (2 pcs)
Shape Parts Name
Mounting plate insu-
lation (2 pcs)
Window gap insula-
tion (1 pcs)
Fixing clips
(2 pcs)
Security brackets
(2 pcs)
Bracket screws
(2 pcs)
Installation Tools
Shape Parts Name
⊕Driver
Tape ruler, knife
Power drill,
Ø 3 mm drill blade
Shape Parts Name
“No residue”
duct tape
* Installation tools are not included with the product.

12 INSTALLATION
WINDOW VENT PANEL AND EXTENSIONS
The window installation kit allows you to install the air conditioner in most vertical-sliding windows 58 cm to
153 cm wide, or horizontal-sliding windows from 58 cm to 153 cm high.
1. For window openings shorter than 58 cm, trim panel
A to fit the opening.
2. For longer window openings, assemble and adjust
the panels to fit the window opening. Use Mounting
plate screws (included) to fix the panels together at
the proper length.
For window openings from 59.5 cm to 96.5 cm,
use the window vent panel (Panel A) and an
extension panel (Panel B).
For window openings from 99 cm to 114.5 cm,
use the window vent panel (Panel A) and an
extension panel (Panel C).
For window openings from 117 cm to 153 cm,
use the window vent panel (Panel A) and two
extension panels (Panel B and Panel C).
Fig. a Fig. b
Fig. c Fig. d
For an 58 cm window opening, use the window
vent panel (Panel A) by itself.
Window Installation Kit (Includes 1 Window
Vent Panel and 2 Extension Panels)
Panel A (58 cm)
58 cm
58 cm
99 cm – 114.5 cm
117 cm – 153 cm
117 cm – 153 cm
Panel B
Panel B
Panel C
Panel C
99 cm – 114.5 cm
59.5 cm – 96.5 cm
59.5 cm – 96.5 cm
Panel B(40 cm) Panel C (58 cm)
2 Extension Panels
1 Window Vent Panel
Panel
Window open
A B C Fig.
(58 cm) (40 cm) (58 cm)
58 cm
√a
59.5 cm~96.5 cm
√ √ b
99 cm~114.5 cm
√ √ c
117 cm~153 cm
√ √ √ d
INSTALLATION
12
Mounting plate
screws Mounting plate
screws

13
INSTALLATION
INSTALLATION 13 EN
* If the screw fixing holes do not match, use a power
drill to drill the holes (3 mm) in the outer mounting
plate in accordance with the inner screw holes.
* Refer to the <Positioning Vent Hose> to adjust the hose
outlet position.
Fit the chassis fixing clips at both ends of the
mounting plate.
Secure the mounting plate screws in the mounting
holes on both sides of the mounting plate.
<Small Windows>
After adjusting the length of the mounting plate to the chassis
height, insert the clip into the window sill.
INSTALLATION (VERTICAL)
1 Inserting Panel Assembly
2 Connecting Vent Hose
Insert the hose into the groove in the insertion direction.
Push the hose in the assembling direction to assemble
with the mounting plate.
Inserting direction
Assembling
direction

14 INSTALLATION
INSTALLATION
14
!
Cut the mounting plate insulation to the chassis
length and insert it on both sides of the mounting plate.
Cut the window gap insulation to the window length
and insert it into the window gap.
Be sure to install the window fixing bracket to prevent
the window from opening outside.
CAUTION
Move the mounting plate to the end of the chassis, close the
window and secure it with the security bracket.
3 Attaching Foam Weather Seals
4 Positioning Vent Hose
For best results, keep the vent hose as short and straight as possible. However, shape the diffuser end of the vent hose into
an inverted U shape just inside the window to allow any rain or condensation to drain out the window.
Minimum
<Best positioning> <inverted U shape> <Correct Installation Position>
50 cm
50 cm
40 cm

INSTALLATION 15 EN
INSTALLATION (HORIZONTAL)
1 Attaching Foam Weather Seals
• NOTE : Take care not to block drain holes in the exterior sill. If necessary,
cut slots in the foam seal to allow any moisture to drain out the window sill drains.
2 Inserting Panel Assembly
3 Sealing Gap between Sashes
Tip: For a tighter seal, use “no residue” duct tape to seal the gap between the sashes.
Measure and cut the included window gap insulation to fit the window opening. Stuff it between the window sashes to
prevent air and insects from getting into the room.
Bracket screws
Security
brackets
Insert the panel assembly in the bottom sash channel as in step 2. Use care when installing the assembly, which will
now fit very tightly in the opening.
Close the sash tightly against the top of the panel assembly. For a tighter seal, use “no residue” duct tape (not
included) to seal any gaps around the installed panel assembly.
• If needed, install the included security bracket with a bracket screws.
Cut the mounting plate insulation to the chassis length and insert it on both sides of the
mounting plate.
(Attaching the foam weather seals to the panel assembly rather than the window sash and
frame makes for easier cleanup when removing the panel assembly.)
Adhesive short foam
weather seals
Adhesive short foam
weather seals
Mounting plate insulation
Indoor
Interlor
Mounting
plate insulation
Mounting
plate insulation
Indoor
Interlor
Base mounting
plate Extension
panel

INSTALLATION
16
4 Connecting Vent Hose
5 Positioning Vent Hose
Align the tabs on the diffuser end of the vent hose to the slots in the panel assembly opening. Insert the diffuser and push it in
the Lock direction to assemble with the mounting plate.
• If disconnected, reconnect the other end of the vent hose to the product by inserting the vent hose into the product with
the mounting ring facing out. If the hose doesn’t snap into place, rotate it slightly so the 2 lines at the front align.
For best results, keep the vent hose as short and straight as possible. However, shape the diffuser end of the vent hose into
an inverted U shape just inside the window to allow any rain or condensation to drain out the window.
Window gap insulation Mounting ring (2) UnLock
lock
(1) Insert
Minimum
<Best positioning> <inverted U shape> <Correct Installation Position>
50 cm
50 cm
40 cm

OPERATION
Control Panel and Remote Control
Remote Control
1
2
610
3
4
7
5
Power ( )
Press to turn the air conditioner ON or OFF
Auto
Swing
.
Incl. auto.
Vit. vent.
Annuler
Diagnostic (5s)
Minuteur Veille
°C ↔ °F (5s)
1 2 3 9 4 5
7 6
8
OPERATION 17 EN
3
4
Sleep Mode
This mode keeps operating noise to a
minimum and turns the air conditioner off
after a set time. The timer can be set from
1 to 12 hours.
Fan Speed
NOTE
2Operation Mode
Press the Mode button to cycle between
3 types of air conditioner operation:
Cool / Dry / Fan.
Cool - This mode is ideal on hot days to
cool and dehumidify the room quickly. Use
the buttons to set the desired
room temperature and use the Fan Speed
button to set the desired fan circulation
speed.
Fan - In this mode the fan circulates
air but the compressor does not run. Use
the Fan Speed button to set fan speed to
w. In this mode, you cannot
adjust the set temperature.
Dry - This mode is ideal for rainy and
damp days to dehumidify the room rather
removed from the room by the combination
of compressor operation and the fan speed
off once the set temperature is reached.
Fan speed cannot be adjusted in mode.
5Auto Swing
Press Sleep button of remote controller
can be switched between degrees
NOTE
To set the brightness on the control
panel, press Mode button on the control
s
This function adjusts the direction of the
air flow vertically. Press Auto Swing
button repeatedly and select the desired
direction.
In the Sleep Mode, the setting temperature
increases by 2 °F after 30 minutes and
The setting temperature increases up to
4 °F from the preset temperature.
additional 2 °F after another 30 minutes
for a more comfortable sleep.
1

6
Clean Filter
The Clean Filter LED lights up to notify you
press Sleep button on
the control panel for 3 seconds to turn off
the Clean Filter light.
NOTE
control panel, not the remote control.
This feature is a reminder to clean the air
filter for more efficient operation. The LED
light turns on after 250 hours of operation.
7Temperature Control
To adjust the desired room temperature in
Cool or Dry mode. The desired room
temperature can be set between 60˚F-86˚F
(16 °C–30 °C). Press or arrows to
increase or decrease temperature setting.
10 Clear
Cancel Sleep and Timer settings.
NOTE
Auto Restart: In case of turning off the air
conditioner due to power failure, your unit will
resume its last operation several minutes after
power is restored.
Delay ON/OFF Timer
Delay ON - When the air conditioner is off,
set it to automatically turn on from 1 to 24
hours later, at its previous mode and fan
settings.
Delay OFF - When the air conditioner is on,
set it to automatically turn off from 1 to 24
hours later.
NOTE
NOTE
8
9
Wi-Fi
Press and button together on the
control panel for 3 seconds, the tempera-
ture display can be switched between
degrees Fahrenheit (ºF) and degrees
Celsius (ºC).
Enables connection of the air conditioner
to the home Wi-Fi.
To connect Wi-Fi, press the Fan Speed
button on the control panel for 3 seconds.
NOTE
Press the Clear button on remote controller
for 5 seconds, the Smart Diagnosis function
works.
Each press of the Timer button advances
the timer by 1 hour. After the last press of
the Delay OFF Timer the display returns to
the temperature setting.
1
2
3
Turn on the product, set it to Cool mode
and let it run for at least 10 seconds.
Press and hold the Auto Swing button for
3 seconds until On appears in the display.
NOTE
The condensation fan is now turned on.
When the appliance is turned off, Co
appears in the display and the fan will
continue to run for 10 minutes. The
appliance will then shut down as normal.
Some functions cannot be used while this option
is turned on.
This option must be set using the control panel,
not the remote control.
and hold the Auto Swing button for 3
seconds until OF appears in the display.
Turning Condensation Fan Off
1When the product is powered ON, press
2The condensation fan is now turned off.
The appliance will shut down immediately
when it is turned off.
Removing Condensation
Buildup
Condensation can build up inside the unit when
the Cool and Dry modes are used. The fan can
be set to run for a short period after the product
is turned off to help keep the inside of the
appliance dry. This option is off by default.
Turning Condensation Fan On
OPERATION
18

SMART FUNCTIONS 19 EN
SMART FUNCTIONS
LG ThinQ Application
This feature is only available on models with the or
ThinQ logo.
The LG ThinQ application allows you to communicate
with the appliance using a smartphone.
LG ThinQ Application Features
Communicate with the appliance from a smartphone
using the convenient smart features.
Smart DiagnosisTM
If you experience a problem while using the appliance,
this smart diagnosis feature will help you diagnose the
problem.
Settings
Allows you to set various options on the appliance and
in the application.
NOTE
•If you change your wireless router, internet service
provider, or password, delete the registered appliance
from the LG ThinQ application and register it again.
•The application is subject to change for appliance
improvement purposes without notice to users.
•Functions may vary by model.
Before Using LG ThinQ Application
1 Check the distance between the appliance and the
wireless router (Wi-Fi network).
•If the distance between the appliance and the
wireless router is too far, the signal strength
becomes weak. It may take a long time to register
or installation may fail.
2 Turn off the Mobile data or Cellular Data on your
smartphone.
3 Connect your smartphone to the wireless router.
NOTE
•To verify the Wi-Fi connection, check that icon on
the control panel is lit.
•The appliance supports 2.4 GHz Wi-Fi networks
only. To check your network frequency, contact your
Internet service provider or refer to your wireless
router manual.
•LG ThinQ is not responsible for any network
connection problems or any faults, malfunctions, or
errors caused by network connection.
•If the appliance is having trouble connecting to the
Wi-Fi network, it may be too far from the router.
Purchase a Wi-Fi repeater (range extender) to
improve the Wi-Fi signal strength.
•The Wi-Fi connection may not connect or may
be interrupted because of the home network
environment.
•The network connection may not work properly
depending on the Internet service provider.
•The surrounding wireless environment can make the
wireless network service run slowly.

Wireless LAN Module Specifications
Frequency
Range 2412 to 2462 MHz
Output
Power
(Max)
Industry Canada Statement (For
transmitter module contained in
this product)
1) This device may not cause interference.
2) This device must accept any interference, including
interference that may cause undesired operation
of the device.
IC Radiation Exposure Statement
This equipment complies with IC radiation
exposure limits set forth for an uncontrolled
environment. This equipment should be installed
and operated with a minimum distance of 20 cm
(7.8 inches) between the antenna and your body.
•
THE MANUFACTURER IS NOT RESPONSIBLE
FOR ANY RADIO OR TV INTERFERENCE
CAUSED BY UNAUTHORIZED MODIFICATIONS
TO THIS EQUIPMENT. SUCH MODIFICATIONS
COULD VOID THE USER’S AUTHORITY TO
OPERATE THE EQUIPMENT.
NOTE
This device contains licence-exempt transmitter(s)/
receiver(s) that comply with Innovation, Science and
Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two
conditions:
SMART FUNCTIONS
20
<30 dBm
•
The appliance cannot be registered due to problems
with the wireless signal transmission. Unplug the
appliance and wait about a minute before trying
again.
•
If the firewall on your wireless router is enabled,
disable the firewall or add an exception to it.
•
The wireless network name (SSID) should be a
combination of English letters and numbers. (Do not
use special characters.)
•
Smartphone user interface (UI) may vary depending
on the mobile operating system (OS) and the
manufacturer .
•
If the security protocol of the router is set to
WEP
,
you may fail to set up the network. Please change it
to other security protocols (
WPA2
is recommended)
and register the product again.
Installing the LG ThinQ Application
Search for the
LG ThinQ
application from the Google
Play Store or Apple App Store on a smartphone. Follow
instructions to download and install the application.
Open Source Software Notice
Information
To obtain the source code under GPL, LGPL, MPL, and
other open source licenses, that is contained in this
product, please visit http://opensource.lge.com.
In addition to the source code, all referred license terms,
warranty disclaimers and copyright notices are available
for download.
LG Electronics will also provide open source code
to you on CD-ROM for a charge covering the cost
of performing such distribution (such as the cost of
media, shipping, and handling) upon email request to
three years after our last shipment of this product. This
offer is valid to anyone in receipt of this information.
Other manuals for LP1419IVSM
5
Table of contents
Other LG Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

CLIMAVENETA
CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea
Midea EWK06CW5 user manual

Pioneer
Pioneer FAB Series installation manual

SPT
SPT WA-1511S user manual

Mitsubishi Electric
Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual