LG DLGX3071 Series User manual

OWNER’S MANUAL
DRYER
Before beginning installation, read these instructions carefully. This
will simplify installation and ensure that the dryer is installed correctly
and safely. Leave these instructions near the dryer after installation
for future reference.
P/No.: MFL62512898 www.lg.com
ENGLISH ESPAÑOL
DLEX3470* DLGX3471*
DLEX3070* DLGX3071*

2
SPECIAL FEATURES
EASY-TO-USE CONTROL PANEL
Rotate the cycle selector knob to select the desired dry cycle. Add cycle options or adjust settings with the touch of a button.
EASY-ACCESS REVERSIBLE DOOR
The wide-opening door provides easy access for loading and unloading. The door hinge can be reversed to adjust for installation location.
STEAM FUNCTIONS
LG’s steam technology allows you to inject fabrics with a swirling jet of hot steam to refresh clothes, reduce static, and make ironing
easier. Simply select the STEAM FRESH™ cycle, or you can add a Steam option to selected cycles.
FLOW SENSE™ DUCT BLOCKAGE SENSING SYSTEM INDICATOR
The FLOW SENSE™ duct blockage sensing system detects and alerts you to blockages in the ductwork that reduce exhaust flow from the
dryer. Clean exhaust systems increase efficiency and reduce drying times.
SMARTDIAGNOSIS™
Should you experience any technical difficulty with your dryer, it has the capability of transmitting data via your telephone to the
Customer Information Center. The call center agent records the data transmitted from your machine and uses it to analyze the issue,
providing a fast and effective diagnosis (refer to page 43).
SPECIAL FEATURES

3
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
WWARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent
property damage, injury to persons, or death.
Your Safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word DANGER, WARNING, or CAUTION.
These words mean:
WDANGER
You will be killed or seriously injured if you don’t immediately follow instructions.
WWARNING
You can be killed or seriously injured if you don’t follow instructions.
WCAUTION
You may be slightly injured or cause damage to the product if you do not follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if
the instructions are not followed.
t%POPUJOTUBMMBDMPUIFTESZFSXJUIGMFYJCMFQMBTUJDWFOUJOHNBUFSJBMT*GGMFYJCMFNFUBMGPJMUZQFEVDUJTJOTUBMMFEJUNVTUCFPG
BTQFDJGJDUZQFJEFOUJGJFECZUIFBQQMJBODFNBOVGBDUVSFSBTTVJUBCMFGPSVTFXJUIDMPUIFTESZFST'MFYJCMFWFOUJOHNBUFSJBMTBSF
LOPXOUPDPMMBQTFCFFBTJMZDSVTIFEBOEUSBQMJOU5IFTFDPOEJUJPOTXJMMPCTUSVDUDMPUIFTESZFSBJSGMPXBOEJODSFBTFUIFSJTLPG
fire.
t%POPUTUPSFPSVTFHBTPMJOFPSPUIFSGMBNNBCMFWBQPSTBOEMJRVJETJOUIFWJDJOJUZPGUIJTBQQMJBODFPSBOZPUIFSBQQMJBODFT
t*OTUBMMBUJPOBOETFSWJDFNVTUCFQFSGPSNFECZBRVBMJGJFEJOTUBMMFSTFSWJDFBHFODZPSUIFHBTTVQQMJFS
t*OTUBMMUIFDMPUIFTESZFSBDDPSEJOHUPUIFNBOVGBDUVSFSTJOTUSVDUJPOTBOEMPDBMDPEFT
t4BWFUIFTFJOTUSVDUJPOT
8)"550%0*':064.&--("4
%POPUUSZUPMJHIUBNBUDIPSDJHBSFUUFPSUVSOPOBOZHBTPSFMFDUSJDBMBQQMJBODF
%POPUUPVDIBOZFMFDUSJDBMTXJUDIFT%POPUVTFBOZQIPOFJOZPVSCVJMEJOH
$MFBSUIFSPPNCVJMEJOHPSBSFBPGBMMPDDVQBOUT
*NNFEJBUFMZDBMMZPVSHBTTVQQMJFSGSPNBOFJHICPSTQIPOF'PMMPXUIFHBTTVQQMJFSTJOTUSVDUJPOTDBSFGVMMZ
*GZPVDBOOPUSFBDIZPVSHBTTVQQMJFSDBMMUIFGJSFEFQBSUNFOU
WWARNING:This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive
harm.
Wash hands after handling.
W
IMPORTANT SAFETY INSTRUCTIONS

4
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
WWARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent
property damage, injury to persons, or death.
#"4*$4"'&5:13&$"65*0/4
WWARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
t3FBEBMMJOTUSVDUJPOTCFGPSFVTJOHUIFESZFS
t#FGPSFVTFUIFESZFSNVTUCFQSPQFSMZJOTUBMMFEBTEFTDSJCFEJO
this manual.
t%POPUQMBDFJUFNTFYQPTFEUPDPPLJOHPJMTJOZPVSESZFS Items
contaminated with cooking oils may contribute to a chemical
reaction that could cause a load to catch fire.
t%POPUESZBSUJDMFTUIBUIBWFCFFOQSFWJPVTMZDMFBOFEJOXBTIFE
in, soaked in, or spotted with gasoline, dry-cleaning solvents, or
other flammable or explosive substances as they give off vapors
that could ignite or explode.
t%POPUSFBDIJOUPUIFESZFSJGUIFESVNPSBOZPUIFSQBSUJT
NPWJOH
t%POPUSFQBJSPSSFQMBDFBOZQBSUPGUIFESZFSPSBUUFNQUBOZ
servicing unless specifically recommended in this Owner’s Manual
or in published user-repair instructions that you understand and
have the skills to carry out.
t%POPUUBNQFSXJUIDPOUSPMT
t#FGPSFUIFESZFSJTSFNPWFEGSPNTFSWJDFPSEJTDBSEFESFNPWFUIF
door to the drying compartment.
t%POPUBMMPXDIJMESFOUPQMBZPOPSJOUIFESZFS$MPTFTVQFSWJTJPO
of children is necessary when the dryer is used near children.
t%POPUVTFGBCSJDTPGUFOFSTPSQSPEVDUTUPFMJNJOBUFTUBUJDVOMFTT
recommended by the manufacturer of the fabric softener or
product.
t%POPUVTFIFBUUPESZBSUJDMFTDPOUBJOJOHGPBNSVCCFSPS
TJNJMBSMZUFYUVSFESVCCFSMJLFNBUFSJBMT
t,FFQBSFBBSPVOEUIFFYIBVTUPQFOJOHBOEBEKBDFOUTVSSPVOEJOH
areas free from the accumulation of lint, dust, and dirt.
t5IFJOUFSJPSPGUIFESZFSBOEFYIBVTUWFOUTIPVMECFDMFBOFE
periodically by qualified service personnel.
t%POPUJOTUBMMPSTUPSFUIFESZFSXIFSFJUXJMMCFFYQPTFEUPUIF
weather.
t"MXBZTDIFDLUIFJOTJEFPGUIFESZFSGPSGPSFJHOPCKFDUT
t$MFBOMJOUTDSFFOCFGPSFPSBGUFSFBDIMPBE
t%POPUTUPSFQMBTUJDQBQFSPSDMPUIJOHUIBUNBZCVSOPSNFMU
POUPQPGUIFESZFSEVSJOHPQFSBUJPO
IMPORTANT SAFETY INSTRUCTIONS

5
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
WWARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent
property damage, injury to persons, or death.
(306/%*/(*/4536$5*0/4
WWARNING
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or
service person if you are in doubt that the appliance is properly grounded.
4"'&5:*/4536$5*0/4'03*/45"--"5*0/
WWARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
t1SPQFSMZHSPVOEESZFSUPDPOGPSNXJUIBMMHPWFSOJOHDPEFT
BOEPSEJOBODFT Follow details in the installation instructions.
Electric shock can result if the dryer is not properly grounded.
t#FGPSFVTFUIFESZFSNVTUCFQSPQFSMZJOTUBMMFE as described
in this manual. Electric shock can result if the dryer is not properly
grounded.
t*OTUBMMBOETUPSFUIFESZFSXIFSFJUXJMMOPUCFFYQPTFEUP
UFNQFSBUVSFTCFMPXGSFF[JOHPSFYQPTFEUPUIFXFBUIFS
t"MMSFQBJSTBOETFSWJDJOHNVTUCFQFSGPSNFECZBOBVUIPSJ[FE
TFSWJDFSVOMFTTTQFDJGJDBMMZSFDPNNFOEFEJOUIJT0XOFST
.BOVBM6TFPOMZBVUIPSJ[FEGBDUPSZQBSUTFailure to follow this
warning can cause serious injury, fire, electric shock, or death.
t5PSFEVDFUIFSJTLPGFMFDUSJDTIPDLEPOPUJOTUBMMUIFESZFSJO
IVNJETQBDFT Failure to follow this warning can cause serious
injury, fire, electric shock, or death.
t$POOFDUUPBQSPQFSMZSBUFEQSPUFDUFEBOETJ[FEQPXFS
DJSDVJUUPBWPJEFMFDUSJDBMPWFSMPBEImproper power circuit can
melt, creating electric shock and/or fire hazard.
t3FNPWFBMMQBDLJOHJUFNTBOEEJTQPTFPGBMMTIJQQJOH
NBUFSJBMTQSPQFSMZFailure to do so can result in death, explosion,
fire, or burns.
t1MBDFESZFSBUMFBTUJODIFTBCPWFUIFGMPPSGPSBHBSBHF
JOTUBMMBUJPOFailure to do so can result in death, explosion, fire, or
burns.
t,FFQBMMQBDLBHJOHGSPNDIJMESFO Packaging material can be
dangerous for children. There is a risk of suffocation.
t%POPUJOTUBMMOFBSBOPUIFSTPVSDFPGIFBUTVDIBTBTUPWF
DPPLJOHPWFO Failure to do so can cause deform, smoke and fire.
t%POPUQMBDFDBOEMFTTNPLJOHNBUFSJBMTPSPUIFSGMBNNBCMFT
POUPQPGUIFQSPEVDU Dripping wax, smoke, or fire can result.
t3FNPWFBMMQSPUFDUJWFWJOZMGJMNGSPNUIFQSPEVDUFailure to do
so can cause product damage, smoke or fire.
This appliance must be grounded. In the event of malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current. This
appliance must be equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
Do not modify the plug provided with the appliance. If it will not fit
the outlet, have a proper outlet installed by a qualified electrician.
This appliance must be connected to a grounded metal, permanent
wiring system or an equipment-grounding conductor must be
run with the circuit conductors and connected to the equipment-
grounding terminal or lead on the appliance.
Electric shock can result if the dryer is not properly grounded.
IMPORTANT SAFETY INSTRUCTIONS

6
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
WWARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent
property damage, injury to persons, or death.
4"'&5:*/4536$5*0/4'03*/45"--"5*0/
WWARNING
To reduce the risk of injury to persons, follow all industry recommended safety procedures including the use of long sleeved gloves and
safety glasses. Failure to follow all of the safety warnings in this manual could result in property damage, injury to persons, or death.
Exhaust/Ducting:
4"'&5:*/4536$5*0/4'0345&".'6/$5*0/4
WWARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
t%POPUPQFOUIFESZFSEPPSEVSJOHTUFBNDZDMFT Failure to
follow these instructions can result in a burn hazard.
t%POPUESZBSUJDMFTUIBUIBWFCFFOQSFWJPVTMZDMFBOFEJO
XBTIFEJOTPBLFEJOPSTQPUUFEXJUIHBTPMJOFESZDMFBOJOH
TPMWFOUTPSPUIFSGMBNNBCMFPSFYQMPTJWFTVCTUBODFTBTUIFZ
HJWFPGGWBQPSTUIBUDPVMEJHOJUFPSFYQMPEF Failure to follow
these instructions can result in fire or death.
t%POPUGJMMUIFTUFBNGFFEFSXJUIHBTPMJOFESZDMFBOJOH
TPMWFOUTPSPUIFSGMBNNBCMFPSFYQMPTJWFTVCTUBODFT Failure
to follow these instructions can result in fire or death.
t%POPUUPVDIUIFTUFBNOP[[MFJOUIFESVNEVSJOHPSBGUFSUIF
TUFBNDZDMF Failure to follow these instructions can result in a
burn hazard.
t%POPUGJMMUIFTUFBNGFFEFSXJUIIPUXBUFSPWFS'$
Failure to follow these instructions can result in a burn hazard.
t(BTESZFST.645CFFYIBVTUFEUPUIFPVUTJEF Failure to follow
these instructions can result in fire or death.
t5IFESZFSFYIBVTUTZTUFNNVTUCFFYIBVTUFEUPUIFPVUTJEFPG
UIFEXFMMJOH*GUIFESZFSJTOPUFYIBVTUFEPVUEPPSTTPNFGJOF
MJOUBOEMBSHFBNPVOUTPGNPJTUVSFXJMMCFFYQFMMFEJOUPUIF
MBVOESZBSFB. An accumulation of lint in any area of the home can
create a health and fire hazard.
t6TFPOMZSJHJENFUBMPSGMFYJCMFNFUBMJODIEJBNFUFS
EVDUXPSLJOTJEFUIFESZFSDBCJOFUPSGPSFYIBVTUJOHUPUIF
PVUTJEF6TFPGQMBTUJDPSPUIFSDPNCVTUJCMFEVDUXPSLDBO
DBVTFBGJSF Punctured ductwork can cause a fire if it collapses or
becomes otherwise restricted in use or during installation.
t%VDUXPSLJTOPUQSPWJEFEXJUIUIFESZFSBOEZPVTIPVME
PCUBJOUIFOFDFTTBSZEVDUXPSLMPDBMMZ5IFFOEDBQTIPVME
IBWFIJOHFEEBNQFSTUPQSFWFOUCBDLESBGUXIFOUIFESZFSJT
not in use. Failure to follow these instructions can result in fire or
death.
t5IFFYIBVTUEVDUNVTUCFJODIFTDNJOEJBNFUFSXJUI
OPPCTUSVDUJPOT5IFFYIBVTUEVDUTIPVMECFLFQUBTTIPSUBT
QPTTJCMF.BLFTVSFUPDMFBOBOZPMEEVDUTCFGPSFJOTUBMMJOH
ZPVSOFXESZFS Failure to follow these instructions can result in
fire or death.
t3JHJEPSTFNJSJHJENFUBMEVDUJOHJTSFDPNNFOEFEGPSVTF
CFUXFFOUIFESZFSBOEUIFXBMM*OTQFDJBMJOTUBMMBUJPOT
XIFOJUJTJNQPTTJCMFUPNBLFBDPOOFDUJPOXJUIUIFBCPWF
SFDPNNFOEBUJPOTB6-MJTUFEGMFYJCMFNFUBMUSBOTJUJPOEVDU
NBZCFVTFECFUXFFOUIFESZFSBOEXBMMDPOOFDUJPOPOMZ
5IFVTFPGUIJTEVDUJOHXJMMBGGFDUESZJOHUJNF Failure to follow
these instructions can result in fire or death.
t%0/05VTFTIFFUNFUBMTDSFXTPSPUIFSGBTUFOFSTXIJDI
FYUFOEJOUPUIFEVDUUIBUDPVMEDBUDIMJOUBOESFEVDFUIF
FGGJDJFODZPGUIFFYIBVTUTZTUFN Secure all joints with duct tape.
For complete details, follow the Installation Instructions. Failure to
follow these instructions can result in fire or death.
IMPORTANT SAFETY INSTRUCTIONS

7
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
WWARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent
property damage, injury to persons, or death.
4"'&5:*/4536$5*0/4'03$0//&$5*/(&-&$53*$*5:
WWARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
4"7&5)&4&*/4536$5*0/4
t%POPUVOEFSBOZDJSDVNTUBODFTDVUPSSFNPWFUIFHSPVOE
QSPOHGSPNUIFQPXFSDPSETo prevent injury to persons or
damage to the dryer, the electrical power cord must be plugged
into a properly grounded outlet.
t'PSQFSTPOBMTBGFUZUIJTESZFSNVTUCFQSPQFSMZHSPVOEFE
Failure to do so can result in electric shock or injury.
t3FGFSUPUIFJOTUBMMBUJPOJOTUSVDUJPOTJOUIJTNBOVBMGPSTQFDJGJD
FMFDUSJDBMSFRVJSFNFOUTGPSZPVSNPEFM Failure to follow these
instructions can create an electric shock hazard and/or a fire
hazard.
t5IJTESZFSNVTUCFQMVHHFEJOUPBQSPQFSMZHSPVOEFEPVUMFU
&MFDUSJDTIPDLDBOSFTVMUJGUIFESZFSJTOPUQSPQFSMZHSPVOEFE
)BWFUIFXBMMPVUMFUBOEDJSDVJUDIFDLFECZBRVBMJGJFE
FMFDUSJDJBOUPNBLFTVSFUIFPVUMFUJTQSPQFSMZHSPVOEFE
Failure to follow these instructions can create an electric shock
hazard and/or a fire hazard.
t5IFESZFSTIPVMEBMXBZTCFQMVHHFEJOUPJUTPXOJOEJWJEVBM
FMFDUSJDBMPVUMFUXIJDIIBTBWPMUBHFSBUJOHUIBUNBUDIFT
UIFSBUJOHQMBUFThis provides sparkling performance and also
prevents overloading house wiring circuits which could cause a
fire hazard from overheated wires.
t/FWFSVOQMVHZPVSESZFSCZQVMMJOHPOUIFQPXFSDPSE"MXBZT
HSJQQMVHGJSNMZBOEQVMMTUSBJHIUPVUGSPNUIFPVUMFUThe
power cord can be damaged, resulting in a risk of fire and electric
shock.
t3FQBJSPSSFQMBDFJNNFEJBUFMZBMMQPXFSDPSETUIBUIBWF
CFDPNFGSBZFEPSPUIFSXJTFEBNBHFE%POPUVTFBDPSEUIBU
TIPXTDSBDLTPSBCSBTJPOEBNBHFBMPOHJUTMFOHUIPSBUFJUIFS
end. The power cord can melt, creating an electric shock and/or
fire hazard.
t8IFOJOTUBMMJOHPSNPWJOHUIFESZFSCFDBSFGVMOPUUPQJODI
DSVTIPSEBNBHFUIFQPXFSDPSEThis will prevent injury and
prevent damage to the dryer from fire and electric shock.
IMPORTANT SAFETY INSTRUCTIONS

8
TABLE OF CONTENTS
2SPECIAL FEATURES
3IMPORTANT SAFETY INSTRUCTIONS
3 WHAT TO DO IF YOU SMELL GAS
4 BASIC SAFETY PRECAUTIONS
5 GROUNDING INSTRUCTIONS
5 SAFETY INSTRUCTIONS FOR INSTALLATION
6 SAFETY INSTRUCTIONS FOR STEAM FUNCTIONS
7 SAFETY INSTRUCTIONS FOR CONNECTING
ELECTRICITY
9
INTRODUCING YOUR DRYER
9 Parts
9 Accessories
10 Control Panel Features
11 Display
12 INSTALLATION INSTRUCTIONS
12 Preview Installation Order
13 Installation Location Requirements
13 Clearances
14 Installation with Optional Pedestal Base or Stacking
Kit
15 Leveling the Dryer
16 Reversing the Door
18 Installing the Side Vent Kit
19 Venting the Dryer
21 Connecting Gas Dryers
23 Connecting Electric Dryers
28 Special Requirements for Manufactured or Mobile
Homes
28 Final Installation Check
29 Installation Test (Exhaust Check)
31 HOW TO USE
31 Operating the Dryer
32 Cycle Guide
33 Sorting Load
33 Loading the Dryer
33 Check the Lint Filter before Every Load
34 Cycle Setting Buttons
35 Special Functions
36 Custom Program
36 Steam Functions
38 Steam Cycle Guide
39 MAINTENANCE
39 Regular Cleaning
40 TROUBLESHOOTING
40 Before Calling for Service
42 SPECIFICATIONS
43 USING SMARTDIAGNOSISTM
44 OPTIONAL ACCESSORIES
44 Stacking Kit Installation
TABLE OF CONTENTS

9
ENGLISH
INTRODUCING YOUR DRYER
INTRODUCING YOUR DRYER
PART AND ACCESSORIES
Parts
NOTE
t$POUBDU-($VTUPNFS4FSWJDFJGBOZBDDFTTPSJFTBSFNJTTJOH
t'PSZPVSTBGFUZBOEGPSFYUFOEFEQSPEVDUMJGFVTFPOMZBVUIPSJ[FEDPNQPOFOUT5IFNBOVGBDUVSFSJTOPUSFTQPOTJCMFGPSQSPEVDU
malfunction or accidents caused by the use of separately purchased unauthorized components or parts.
t5IFJNBHFTJOUIJTNBOVBMNBZCFEJGGFSFOUGSPNUIFBDUVBMDPNQPOFOUTBOEBDDFTTPSJFTBOEBSFTVCKFDUUPDIBOHFCZUIFNBOVGBDUVSFS
without prior notice for product improvement purposes.
Accessories
1FEFTUBM
TPMETFQBSBUFMZ
4UBDLJOHLJU
TPMETFQBSBUFMZ
*ODMVEFEBDDFTTPSJFT
%SZJOHSBDL
0QUJPOBMBDDFTTPSJFT
Power Cord
Location
(Gas Models)
Gas
Connection
Location
(Gas Models)
Exhaust Duct
Outlet
Terminal Block
Access Panel
(Electric
Models)
Control panel
Leveling feet
Lint filter
Reversible
door

10 INTRODUCING YOUR DRYER
Control panel features
Following are instructions for starting and using your new dryer. Please refer to specific sections of
this manual for more detailed information.
WWARNING:To reduce the risk of fire, electric shock, or injury to persons, read this entire manual,
including the Important Safety Instructions, before operating this dryer.
Button %FTDSJQUJPO
108&30/0''#6550/
ü
- Press to turn the dryer ON. Press again to turn the dryer OFF.
/05& Pressing the ON/OFF button during a cycle will cancel that cycle and any load settings will be lost.
$:$-&4&-&$503,/0#
ü
- Turn this knob to select the desired cycle. Once the desired cycle has been selected, the standard presets
will be shown in the display. On MANUAL DRY cycles, these settings can be adjusted using the cycle setting
buttons anytime before starting the cycle.
45"351"64ᦖ/
ü
- Press this button to START the selected cycle. If the dryer is running, use this button to PAUSE the cycle
without losing the current settings.
/05&If you do not press the START/PAUSE button to resume a cycle within 4 minutes, the dryer turns off
automatically.
.03&5*.&-&445*.ᦖ/4
ü
- To adjust the drying time, use these buttons with MANUAL DRY, TIME DRY, and STEAM FRESH™ cycles, as
well as the REDUCE STATIC and EASY IRON options. Press the MORE TIME button to increase the selected
manual cycle time by a minute; press LESS TIME to decrease the cycle time by a minute.
$:$-&4&55*/(#6550/4
ü
- Use these buttons to select the desired cycle settings for the selected cycle. The current settings are shown
in the display. Press the button for that option to view and select other settings.
015*0/#6550/4
ü
- The OPTION buttons allow you to select additional cycle options. Not all settings are available for all cycles.
Refer to the CYCLE GUIDE section of the manual.
45&".'6/$5*0/4
ü
- LG’s steam technology allows you to inject fabrics with a swirling jet of hot steam to refresh clothes, reduce
static, and make ironing easier. Simply select the steam fresh™ cycle, or you can add a STEAM option to
selected cycles.
Operation
LED DisplayCycle Selector Knob
Power Button Start/Pause
Button Dry Level
Button Temp.
Control
Button
Time Dry
Button Signal
Button

11
ENGLISH
Display
The display shows the settings, estimated time remaining, options, and status messages for your
dryer. When the dryer is turned on, the light in the display will illuminate.
INTRODUCING YOUR DRYER
%JTQMBZBOE*DPOT %FTDSJQUJPO
&45*."5&%5*.&3&."*/*/(
ü
- When the START/PAUSE button is pressed, the dryer will display the estimated (SENSOR DRY) or set time
(TIME DRY) remaining, and begin tumbling.
/05& The cycle time on SENSOR DRY cycles may fluctuate as the dryer recalculates drying time for optimal
results
$:$-&$0.1-&5*0/*/%*$"5038*5)$)&$,'*-5&33&.*/%&3
ü
5IJTQPSUJPOPGUIFEJTQMBZTIPXTXIJDITUBHFPGUIFESZJOHDZDMFJTDVSSFOUMZVOEFSXBZ$)&$,'*-5&3
DRYING, or COOLING).
$)*-%-0$,*/%*$"503
ü
8IFO$)*-%-0$,JTTFUUIF$)*-%-0$,JOEJDBUPSXJMMBQQFBSBOEBMMCVUUPOTBSFEJTBCMFEFYDFQUUIF
POWER button. This prevents children from changing settings while the dryer is operating
$)&$,'*-5&33&.*/%&3
ü
5IFEJTQMBZXJMMTIPX$)&$,'*-5&3XIFOUIFESZFSJTUVSOFEPOBTBSFNJOEFSUPDIFDLUIFGJMUFS*UUVSOTPGG
when the START/PAUSE button is pressed.
$6450.130(3".
ü
- If you have a special combination of settings that you use frequently, you can save these settings as a
CUSTOM PROGRAM.
'-084&/4&%6$5#-0$,"(&4&/4*/(4:45&.*/%*$"503
ü
- The FLOW SENSE™ duct blockage sensing system detects and alerts you to blockages in the ductwork that
reduce exhaust flow from the dryer. This improves operating efficiency and helps minimize service calls,
saving your money.

12 INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
Preview installation order
Checking and choosing
the proper location
Leveling the dryer Venting the Dryer
Plugging in the power
cord and grounding
Connecting gas dryers
(Gas dryer type)
Installation test
(Refer to page 29.)
Test run
120V 240V
Connecting electric dryers
(Electric dryer type)
Press and hold

13
ENGLISH
INSTALLATION INSTRUCTIONS
Installation location requirements
WWARNING
3FBEBMMJOTUBMMBUJPOJOTUSVDUJPOTDPNQMFUFMZCFGPSFJOTUBMMJOHBOEPQFSBUJOHZPVSESZFSIt is important that you review this entire
manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust
requirements are provided on the following pages.
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic
cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be exposed to water and/or
weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or
sleeping quarters. Contact your local building inspector.
Clearances
INSTALLATION SPACING FOR RECESSED AREA OR CLOSET INSTALLATION
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0 inches (0 cm) clearance on
the sides and rear. Recommended spacing should be considered for the following reasons:
t"MPDBUJPOUIBUBMMPXTGPSQSPQFSFYIBVTUJOTUBMMBUJPO"HBTESZFS
must be exhausted to the outdoors. See 7FOUJOHUIFESZFS.
t"HSPVOEFEFMFDUSJDBMPVUMFUMPDBUFEXJUIJOGUDNPGFJUIFS
side of the dryer. See $POOFDUJOHFMFDUSJDESZFST.
t"TUVSEZGMPPSUPTVQQPSUUIFUPUBMESZFSXFJHIUPGMCT
kg). The combined weight of a companion appliance should also
be considered.
tNo other fuel-burning appliance can be installed in the same area
as a dryer.
t"EEJUJPOBMTQBDJOHTIPVMECFDPOTJEFSFEGPSFBTFPGJOTUBMMBUJPO
and servicing.
t"EEJUJPOBMDMFBSBODFTNJHIUCFSFRVJSFEGPSXBMMEPPSBOEGMPPS
moldings.
t"EEJUJPOBMTQBDJOHTIPVMECFDPOTJEFSFEPOBMMTJEFTPGUIFESZFS
to reduce noise transfer.
For closet installation with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
t$PNQBOJPOBQQMJBODFTQBDJOHTIPVMEBMTPCFDPOTJEFSFE
24 in.2*
(155 cm2)
18" min.*
(45.7 cm)
1"*
(2.5 cm)
30"
(76.1 cm)
30"
(76.1 cm)
5"**
(12.7 cm)
48 in.2*
(310 cm2)
14" max.*
(35.6 cm)
3"*
(7.6 cm)
3"*
(7.6 cm)
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm)
1"*
(2.5 cm)
5"**
(12.7 cm)
14" max.*
(35.6 cm)
18" min.*
(45.7 cm)
0"
(0 cm)
39"
(99.1 cm)
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm)
NOTE
There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of vibration from one to the
other. Too much vibration, it could cause them to make noise or touch each other causing paint damage and making even more
noise.
NOTE
t"MFWFMGMPPSXJUIBNBYJNVNTMPQFPGJODIDNVOEFSFOUJSFESZFS$MPUIFTNBZOPUUVNCMFQSPQFSMZBOEBVUPNBUJDTFOTPS
cycles may not operate correctly if dryer is not level.
t'PSBHBSBHFJOTUBMMBUJPOZPVXJMMOFFEUPQMBDFUIFESZFSBUMFBTUJODIFTDNBCPWFUIFGMPPS*GVTJOHBQFEFTUBMZPVXJMMOFFE
JODIFTDNUPUIFCPUUPNPGUIFESZFS

14 INSTALLATION INSTRUCTIONS
Installation with optional pedestal base or stacking kit
RECOMMENDED INSTALLATION SPACING FOR CABINET INSTALLATION
tFor cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required.
*Required spacing
**For side or bottom venting,
JODIFTDNTQBDJOHJTBMMPXFE
CLOSET VENTILATION REQUIREMENTS
Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup in the closet. One upper vent opening
XJUIBNJOJNVNPQFOJOHPGTRJODNNVTUCFJOTUBMMFEOPMPXFSUIBOGFFUBCPWFUIFGMPPS0OFMPXFSWFOUPQFOJOHXJUIB
NJOJNVNPQFOJOHPGTRJODN) must be installed no more than one foot above the floor. One example shown uses vent grilles in
the door.
RECOMMENDED INSTALLATION SPACING FOR RECESSED OR CLOSET INSTALLATION, WITH STACKED WASHER AND DRYER
tThe dimensions shown are for the recommended spacing.
*Required spacing
**For side or bottom venting,
JODIFTDNTQBDJOHJTBMMPXFE
30"
(76.1 cm)
5"**
(12.7 cm)
1"**
(2.5 cm)
1"
(2.5 cm)
1"
(2.5 cm)
27"
(68.6 cm)
9"**
(22.9 cm)
7"* (17.8 cm) 7"* (17.8 cm)
1"* (2.5 cm) 5 "**
(14 cm)
1/2
77
1/2
"
(196.8 cm)

15
ENGLISH
Leveling the dryer
WWARNING
t5PSFEVDFUIFSJTLPGJOKVSZUPQFSTPOTBEIFSFUPBMMJOEVTUSZ
SFDPNNFOEFETBGFUZQSPDFEVSFTJODMVEJOHUIFVTFPG
MPOHTMFFWFEHMPWFTBOETBGFUZHMBTTFTFailure to follow this
warning can cause serious injury or death.
t5IFBQQMJBODFTBSFIFBWZ5XPPSNPSFQFPQMFBSFSFRVJSFE
XIFOJOTUBMMJOHUIFESZFSFailure to follow this warning can
cause serious injury or death.
To ensure that the dryer provides optimal drying performance,
it must be level. To minimize vibration, noise, and unwanted
movement, the floor must be a perfectly level, solid surface.
1PTJUJPOUIFESZFSJOUIFGJOBMMPDBUJPO1MBDFBMFWFMBDSPTTUIF
top of the dryer.
t"MMGPVSMFWFMJOHGFFUNVTUSFTUTPMJEMZPOUIFGMPPS(FOUMZQVTI
on the top corners of the dryer to make sure that the dryer does
not rock from corner to corner.
If you are installing the dryer on the optional pedestal, you must
use the leveling feet on the pedestal to level the dryer. The dryer
leveling feet should be fully retracted.
6TFBOBEKVTUBCMFXSFODIUPUVSOUIFMFWFMJOHGFFU5VSO
clockwise to raise the dryer or counterclockwise to lower it.
Raise or lower the leveling feet until dryer is level from side to
side and front to back.
Make sure that all 4 leveling feet are in firm contact with the floor.
Level
Leveling Feet
INSTALLATION INSTRUCTIONS
NOTE
Adjust the leveling feet only as far as necessary to level the
dryer. Extending the leveling feet more than necessary can
cause the dryer to vibrate.

16
0QFOUIFEPPSUPSFWFSTF
$IFDLTDSFXTUPSFNPWF-FGU3JHIU
3. Remove four dummy screws by driver.
Reversing the door
4. Remove two screws and disassembly latch.
)PMEPOUIFIJOHFXIJMFSFNPWFTDSFXTPGIJOHFUPQSFWFOU
door dropping).
3FNPWFEPPSGSPNDBCJOFUDPWFS
Hinge
Dummy
Screw
Open Door
Remove
Door
Hinge Screw
Latch Screw
INSTALLATION INSTRUCTIONS
WWARNING
t5PBWPJEEBNBHFUPUIFESZFSPSUIFEPPSTVQQPSUUIF
EPPSXJUIBTUPPMPSCPYUIBUGJUTVOEFSUIFEPPSPSIBWF
BOBTTJTUBOUTVQQPSUUIFXFJHIUPGUIFEPPS
t"MXBZTSFWFSTFUIFEPPS#&'03&TUBDLJOHUIFESZFSPOUPQ
PGUIFXBTIFS
t"WPJEESPQQJOHUIFEPPSUPBWPJEEBNBHFUPUIFEPPSPS
UIFGMPPS
THE DRYER DOOR IS VERY LARGE AND HEAVY. Failure to follow
the instructions below can result in damage to the dryer,
property damage or injury to persons.

17
ENGLISH
Reversing the door (cont.)
Move door to left side and insert a hinge to hinge hole.
)PMEPOIJOHFXIJMFTDSFXEPXOBIJOHF
(to prevent door dropping).
3. Insert latch to right side and install screws.
4. Screw down four dummy screws right side.
5. Check that the door closes and latches properly.
Latch
Screw
Hinge Screw
Hinge
Dummy
Screw
Swing Door
Hinge hole
INSTALLATION INSTRUCTIONS
WWARNING
t5PBWPJEEBNBHFUPUIFESZFSPSUIFEPPSTVQQPSUUIF
EPPSXJUIBTUPPMPSCPYUIBUGJUTVOEFSUIFEPPSPSIBWF
BOBTTJTUBOUTVQQPSUUIFXFJHIUPGUIFEPPS
t"MXBZTSFWFSTFUIFEPPS#&'03&TUBDLJOHUIFESZFSPOUPQ
PGUIFXBTIFS
t"WPJEESPQQJOHUIFEPPSUPBWPJEEBNBHFUPUIFEPPSPS
UIFGMPPS
THE DRYER DOOR IS VERY LARGE AND HEAVY. Failure to follow
the instructions below can result in damage to the dryer,
property damage or injury to persons.

18 INSTALLATION INSTRUCTIONS
Installing the side vent kit
Your new dryer is shipped to vent to the rear.
It can also be configured to vent to the bottom or side
(right-side venting is not available on gas models).
An adapter kit, part number &&-#, may be purchased
from your LG retailer. This kit contains the necessary duct
components to change the dryer vent location.
3FNPWFUIFSFBSFYIBVTUEVDUSFUBJOJOHTDSFX1VMMPVUUIF
exhaust duct.
OPTION 1: SIDE VENTING
1SFTTUIFUBCTPOUIFLOPDLPVUBOEDBSFGVMMZSFNPWFUIF
knockout for the desired vent opening (right-side venting is
not available on gas models). Press the adapter duct onto the
blower housing and secure to the base of the dryer as shown.
1SFBTTFNCMFBJODIFTDNFMCPXUPUIFOFYUJODIFT
DNEVDUTFDUJPOBOETFDVSFBMMKPJOUTXJUIEVDUUBQF#F
sure that the male end of the elbow faces AWAY from the dryer.
Insert the elbow/duct assembly through the side opening and
press it onto the adapter duct. Secure in place with duct tape.
#FTVSFUIBUUIFNBMFFOEPGUIFEVDUQSPUSVEFTJODIFT
cm) to connect the remaining ductwork.
Attach cover plate to the back of the dryer with included screw.
OPTION 2: BOTTOM VENTING
1SFTTUIFBEBQUFSEVDUPOUPUIFCMPXFSIPVTJOHBOETFDVSFUP
the base of the dryer as shown.
*OTFSUUIFJODIFTDNFMCPXUISPVHIUIFSFBSPQFOJOH
BOEQSFTTJUPOUPUIFBEBQUFSEVDU#FTVSFUIBUUIFNBMFFOEPG
the elbow faces down through hole in the bottom of the dryer.
Secure in place with duct tape.
Attach the cover plate to the back of the dryer with included
screw.
Rear
Exhaust Duct
Retaining
Screw
11/2"
(3.8 cm)
Elbow
Cover
Plate
Elbow
Cover
Plate
,OPDLPVU
#SBDLFU
Adapter
Duct
#SBDLFU
Adapter
Duct
WWARNING
t6TFBIFBWZNFUBMWFOU
t%POPUVTFQMBTUJDPSUIJOGPJMEVDU
t$MFBOPMEEVDUTCFGPSFJOTUBMMJOHUIJTESZFS
t5PSFEVDFUIFSJTLPGJOKVSZUPQFSTPOTBEIFSFUPBMM
JOEVTUSZSFDPNNFOEFETBGFUZQSPDFEVSFTJODMVEJOHUIF
VTFPGMPOHTMFFWFEHMPWFTBOETBGFUZHMBTTFT
t'BJMVSFUPGPMMPXBMMPGUIFTBGFUZXBSOJOHTJOUIJTNBOVBMDPVME
result in property damage, injury to persons, or death.

19
ENGLISH
Venting the dryer
WWARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
t%POPUDSVTIPSDPMMBQTFEVDUXPSL Failure to follow these
instructions can result in fire or death.
t%POPUBMMPXEVDUXPSLUPSFTUPOPSDPOUBDUTIBSQPCKFDUT
Failure to follow these instructions can result in fire or death.
t*GDPOOFDUJOHUPFYJTUJOHEVDUXPSLNBLFTVSFJUJTTVJUBCMF
BOEDMFBOCFGPSFJOTUBMMJOHUIFESZFS Failure to follow these
instructions can result in fire or death.
t7FOUJOHNVTUDPOGPSNUPMPDBMCVJMEJOHDPEFT Failure to follow
these instructions can result in fire or death.
t(BTESZFST.645FYIBVTUUPUIFPVUEPPST
Failure to follow these instructions can result in fire or death.
t6TFPOMZJODIDNSJHJEPSGMFYJCMFNFUBMEVDUXPSL
JOTJEFUIFESZFSDBCJOFUBOEGPSWFOUJOHPVUTJEFFailure to
follow these instructions can result in fire or death.
t5PSFEVDFUIFSJTLPGGJSFDPNCVTUJPOPSBDDVNVMBUJPOPG
DPNCVTUJCMFHBTFT%0/05FYIBVTUESZFSBJSJOUPBOFODMPTFE
BOEVOWFOUJMBUFEBSFBTVDIBTBOBUUJDXBMMDFJMJOHDSBXM
TQBDFDIJNOFZHBTWFOUPSDPODFBMFETQBDFPGBCVJMEJOH
Failure to follow these instructions can result in fire or death.
t5PSFEVDFUIFSJTLPGGJSF%0/05FYIBVTUUIFESZFSXJUI
QMBTUJDPSUIJOGPJMEVDUJOH
Failure to follow these instructions can result in fire or death.
t5IFFYIBVTUEVDUNVTUCFJODIFTDNJOEJBNFUFSXJUI
OPPCTUSVDUJPOT5IFFYIBVTUEVDUTIPVMECFLFQUBTTIPSUBT
QPTTJCMF.BLFTVSFUPDMFBOBOZPMEEVDUTCFGPSFJOTUBMMJOH
ZPVSOFXESZFS Failure to follow these instructions can result in
fire or death.
t3JHJEPSTFNJSJHJENFUBMEVDUJOHJTSFDPNNFOEFEGPSVTF
CFUXFFOUIFESZFSBOEUIFXBMM*OTQFDJBMJOTUBMMBUJPOT
XIFOJUJTJNQPTTJCMFUPNBLFBDPOOFDUJPOXJUIUIFBCPWF
SFDPNNFOEBUJPOTB6-MJTUFEGMFYJCMFNFUBMUSBOTJUJPOEVDU
NBZCFVTFECFUXFFOUIFESZFSBOEXBMMDPOOFDUJPOPOMZ
5IFVTFPGUIJTEVDUJOHXJMMBGGFDUESZJOHUJNF Failure to follow
these instructions can result in fire or death.
t%0/05VTFTIFFUNFUBMTDSFXTPSPUIFSGBTUFOFSTXIJDI
FYUFOEJOUPUIFEVDUUIBUDPVMEDBUDIMJOUBOESFEVDFUIF
FGGJDJFODZPGUIFFYIBVTUTZTUFN4FDVSFBMMKPJOUTXJUIEVDU
tape. Failure to follow these instructions can result in fire or death.
t5PNBYJNJ[FPQFSBUJOHSFTVMUTQMFBTFPCTFSWFUIFEVDUMFOHUI
MJNJUBUJPOTOPUFEJOUIFDIBSUOFYUQBHF Failure to follow these
instructions can result in fire or death.
t%VDUXPSLJTOPUQSPWJEFEXJUIUIFESZFS:PVTIPVMEPCUBJO
UIFOFDFTTBSZEVDUXPSLMPDBMMZ5IFFOEDBQTIPVMEIBWF
IJOHFEEBNQFSTUPQSFWFOUCBDLESBGUXIFOUIFESZFSJTOPUJO
use. Failure to follow these instructions can result in fire or death.
t5IF5PUBMMFOHUIPGGMFYJCMFNFUBMEVDUTIBMMOPUFYDFFEGU
N
t*O$BOBEBUIBUPOMZUIPTFGPJMUZQFGMFYJCMFEVDUTJGBOZ
TQFDJGJDBMMZJEFOUJGJFEGPSVTFXJUIUIFBQQMJBODFCZUIF
NBOVGBDUVSFSTIBMMCFVTFEIn the United States, that only those
foil-type flexible ducts, if any, specifically identified for use with
the appliance by the manufacturer and that comply with the
0VUMJOFGPS$MPUIFT%SZFS5SBOTJUJPO%VDU4VCKFDU"TIBMMCF
used.
INSTALLATION INSTRUCTIONS

20 INSTALLATION INSTRUCTIONS
Venting the dryer (cont.)
%FEVDUGUNGPSFBDIBEEJUJPOBMFMCPX*UJTOPUSFDPNNFOEFE
UPVTFNPSFUIBOGPVS¡FMCPXT
ROUTING AND CONNECTING DUCTWORK
Follow the guidelines below to maximize drying performance and
reduce lint buildup and condensation in the ductwork.
Ductwork and fittings are NOT included and must be purchased
separately.
t6TFJODIDNEJBNFUFSSJHJEPSTFNJSJHJENFUBMEVDUXPSL
t5IFFYIBVTUEVDUSVOTIPVMECFBTTIPSUBTQPTTJCMF
t6TFBTGFXFMCPXKPJOUTBTQPTTJCMF
t5IFNBMFFOEPGFBDITFDUJPOPGFYIBVTUEVDUNVTUQPJOUBXBZGSPN
the dryer.
t6TFEVDUUBQFPOBMMEVDUKPJOUT
t*OTVMBUFEVDUXPSLUIBUSVOTUISPVHIVOIFBUFEBSFBTJOPSEFSUP
reduce condensation and lint buildup on duct surfaces.
t'BJMVSFUPFYIBVTUUIFESZFSDPSSFDUMZXJMMWPJEUIFESZFSTXBSSBOUZ
Ductwork
8"--$"15:1&
0
3
4
0
3
4
/6.#&30'¡
&-#084
."9*.6.-&/(5)0'
ű*/$)%*".&5&33*(*%
.&5"-%6$5
GUN
GUN
GUN
GUN
GUN
GUN
GUN
GUN
GUN
GUN
4"
(10.2 cm)
Recommended
Use only for short
run installations
4"
(10.2 cm)
21/2"
(6.35 cm)
*/$033&$57&/5*/(
$033&$57&/5*/(
NOTE
NOTE
This manual suits for next models
3
Table of contents
Languages:
Other LG Dryer manuals

LG
LG DLE3401 Series User manual

LG
LG DLEX8500 Series User manual

LG
LG RC90V9 V2W Series User manual

LG
LG DLEX5175 Series User manual

LG
LG DLEX9000 Series User manual

LG
LG DL 340 Series User manual

LG
LG DLE4970 Series User manual

LG
LG RC8003C User manual

LG
LG DLGX7801 E Series User manual

LG
LG DT21WS User manual
Popular Dryer manuals by other brands

Siemens
Siemens WT47W580AU Installation and operating instructions

Electrolux
Electrolux T4900CR installation manual

Samsung
Samsung DV45H6300 Series user manual

Miele
Miele TKB 350 WP operating instructions

Bosch
Bosch WTW85T9SSN Installation and operating instructions

ARTHUR MARTIN
ARTHUR MARTIN AW6C4824CB user manual