LG DLGX5102V User manual

Lifds Good
Please read this manual carefully before operating
your dryer and retain it for future reference.
DLEX5101W
DLEX5101V DLGX5102W
DLGX5102V
P/No. MFL62512805 www°lge°com

INTRODUCTION
iMPORTANT SAFETY INSTRUCTIONS
What to Do if You Smell Gas .................................. 3
Basic Safety Precautions ....................................... 4
California Safe Drinking Water And Toxic
Enforcement Act .................................................... 4
Grounding Instructions ........................................... 5
Safety Instructions for Installation .......................... 5
Safety Instructions for Steam Functions ................ 6
Safety Instructions for Connecting Electricity ....... 7
PARTS AND FEATURES
Special Features ..................................................... 8
Key Parts and Components ................................... 9
INSTALLATION INSTRUCTIONS
Installation Location Requirements ...................... 10
Clearances ........................................................... 10
Leveling the Dryer ................................................ 11
Reversing the Door ............................................... 12
Changing the Dryer Vent Location ....................... 13
Venting the Dryer .................................................. 14
Connecting Gas Dryers ........................................ 16
Connecting Electric Dryers ................................... 18
Special Requirements for Manufactured
or Mobile Homes .................................................. 23
Final Installation Check ....................................... 23
Flow Check (Duct Condition Test) ........................ 24
HOW TO USE
Control Panel Features ................................... 25
Operating The Dryer ...................................... 26
Cycle Guide .................................................. 27
Sorting Loads............................................... 28
Loading the Dryer .......................................... 28
Check The Lint Filter Before Every Load ............ 28
The Display ................................................... 29
Cycle Setting Buttons ..................................... 30
Cycle Option Buttons ..................................... 31
Custom Program ........................................... 31
Steam Functions ........................................... 32
Steam Cycle Guide ........................................ 34
USER MAINTENANCE INSTRUCTIONS
Regular Cleaning .................................................. 35
TROUBLESHOOTING
Before Calling for Service ..................................... 36
SPECIFICATIONS
Key Dimensions And Specifications ..................... 38
WARRANTY ...................................................39
2
f_ THANKYOU!
Congratulations on your purchase
and welcome to the LG family. Your
new LG Dryer combines the most
advanced drying sensor technology
with simple operation and high
efficiency.
Follow the operating and care
instructions in this manual and your
dryer will provide many years of
reliable service.

iMPORTANTSAFETYiNSTRUCTiONS
READ ALL iNSTRUCTiONS BSFORE USE
followed to minimize the risk of fire or explosion, electric shock, or to prevent
property damage, personal injury, or loss of life.
Your Safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read
and obey all safety messages.
This isthe safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word DANGER or WARNING.
These words mean:
_:)A_G_::_." You can be killed or seriously injured if you don't immediately follow instructions.
_WARN|NG: You can be killed or seriously injured ifyou don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of
injury, and tell you what can happen if the instructions are not followed.
Do not install aclothes dryer with
flexible plastic venting materials. If
flexible metal (foil type) duct is in-
stalled, it must be of a specific type
identified by the appliance manufac=
turer as suitable for use with clothes
dryers. Flexible venting materials are
known to collapse, be easily crushed,
and trap lint. These conditions will
obstruct clothes dryer airflow and
increase the risk of fire.
•Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this appliance or any other
appliances.
•Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier.
,, Install the clothes dryer according to
the manufacturer's instructions and
local codes.
= Save these instructions.
WHAT TO DO IF YOU SMELL GAS:
1. Do not try to light a match or cigarette,
or turn on any gas or electrical
appliance.
2. Do not touch any electrical switches.
Do not use any phone in your building.
3. Clear the room, building, or area of all
occupants.
4. Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions carefully.
5. If you cannot reach your gas
supplier, call the fire department.
5

IMPORTANTSAFETYiNSTRUCTiONS
READ ALL iNSTRUCTiONS BSFORE USE
WARNING For your safety,the information in this manual must be
followed to minimize the risk of fire or explosion, electric shock, or to prevent
property damage, personal injury, or loss of life.
BASIC SAFETY PRECAUTIONS
WARNING=
appliance, follow basic precautions, including the following:
•Read all instructions before using the dryer.
•Before use, the dryer must be properly installed
as described in this manual.
•Do not place items exposed to cooking oils in
your dryer. Items contaminated with cooking
oils may contribute to a chemical reaction that
could cause a load to catch fire.
Do not dry articles that have been previously
cleaned in, washed in, soaked in, or spotted
with gasoline, dry-cleaning solvents, or other
flammable or explosive substances as they give
off vapors that could ignite or explode.
•Do not reach intothe dryer if the drum or any
other part is moving.
Do not repair or replace any part of the dryer
or attempt any servicing unless specifically
recommended in this Use and Care Guide or
in published user-repair instructions that you
understand and have the skills to carry out.
•Do not tamper with controls.
Before the dryer is removed from service or
discarded, remove the door to the drying
compartment.
To reduce the risk of fire, electric shock, or personal injury when using this
Do not allow children to play on or in the dryer.
Close supervision of children is necessary when
the dryer is used near children.
Do not use fabric softeners or products to
eliminate static unless recommended by the
manufacturer of the fabric softener or product.
Do not use heat to dry articles containing
foam rubber or similarly textured rubber-like
materials.
Keep area around the exhaust opening and
adjacent surrounding areas free from the
accumulation of lint, dust, and dirt.
The interior of the dryer and exhaust vent
should be cleaned periodically by qualified
service personnel.
Do not install or store the dryer where it will be
exposed to the weather.
Always check the inside of the dryer for foreign
objects.
Clean lint screen before or after each load.
CALIFORNIA SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT
This act requires the Governor of California to publish a list of substances known to the state to cause
cancer, birth defects, or other reproductive harm and requires businesses to warn customers of potential
exposure to such substances.
Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide,
formaldehyde, and soot, caused primarily by the incomplete combustion of natural gas or LP fuels.
Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be
minimized further by properly venting the dryer to the outdoors.
4

iMPORTANTSAFETYiNSTRUCTiONS
READ ALL iNSTRUCTiONS BSFORE USE
,WARNING For your safety,the information in this manual must be
followed to minimize the risk of fire or explosion, electric shock, or to prevent
property damage, personal injury, or loss of life.
GROUNDING iNSTRUCTiONS
This appliance must be grounded. In the event
of malfunction or breakdown, grounding will
reduce the risk of electric shock by providing
a path of least resistance for electric current.
This appliance must be equipped with a cord
having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances.
WARNING-Improper
connection of the equipment=grounding
conductor can result in a risk of electric shock.
Check with a qualified electrician or service
person if you are in doubt as to whether the
appliance is properly grounded.
Do not modify the plug provided with the
appliance. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
This appliance must be connected to a grounded
metal, permanent wiring system or an equipment-
grounding conductor must be run with the circuit
conductors and connected to the equipment-
grounding terminal or lead on the appliance.
Electrical shock can result if the dryer is not
properly grounded.
SAFETY iNSTRUCTiONS FOR iNSTALLATiON
WARNING: To reduce the risk of fire, electric shock, or personal injury when using this
appliance, follow basic precautions, including the following:
• Properly ground dryer to conform with all
governing codes and ordinances. Follow
details in the installation instructions. Electrical
shock can result if the dryer is not properly
grounded.
•Before use, the dryer must be properly
installed as described in this manual.
Electrical shock can result if the dryer is not
properly grounded.
•install and store the dryer where it will not be
exposed to temperatures below freezing or
exposed to the weather.
•All repairs and servicing must be performed
by an authorized servicer unless specifically
recommended in this Owner's Guide. Use
only authorized factory parts. Failure to follow
this warning can cause serious injury, fire,
electrical shock, or death.
• To reduce the risk of electric shock, do not
install the dryer in humid spaces. Failure to
follow this warning can cause serious injury, fire,
electrical shock, or death.
,Connect to a properly rated, protected,
and sized power circuit to avoid electrical
overload, improper power circuit can melt,
creating electrical shock and/or fire hazard.
Remove all packing items and dispose of all
shipping materials properly. Failure to do so
can result in death, explosion, fire, or burns.
Place dryer at least 18 inches above the floor
for a garage installation. Failure to do so can
result in death, explosion, fire, or burns.
Keep all packaging from children. Packaging
material can be dangerous for children. There is
a risk of suffocation.
Do not install nearby heat item. Such a stove,
oven or heater. Failure to do so can cause
malfunction, smoke, or fire.
Do not place candle and cigarettes on top of
the product. Failure to do so can cause them to
melt, smoke, or catch fire.
•Remove all protective vinyl film from the
product. Failure to do so can cause them to
melt, smoke, or catch fire. 5

I PORTANTSAFETYiNSTRUcTiONS
READ ALL iNSTRUCTiONS BSFORE USE
,WARNING For your safety,the information in this manual must be
followed to minimize the risk of fire or explosion, electric shock, or to prevent
property damage, personal injury, or loss of life.
SAFETY iNSTRUCTiONS FOR iNSTALLATiON
Exhaust/Ducting:
, Gas dryers MUST be exhausted to the
outside. Failure to follow these instructions
can result in fire or death.
• The dryer exhaust system must be exhausted
to the outside of the dwelling, if the dryer is
not exhausted outdoors, some fine lint and
large amounts of moisture will be expelled
into the laundry area. An accumulation of
lint in any area of the home can create a health
and fire hazard.
•Use only rigid metal or flexible metal 4=inch
diameter ductwork inside the dryer cabinet
or for exhausting to the outside. Use of
plastic or other combustible ductwork can
cause a fire. Punctured ductwork can cause
a fire if itcollapses or becomes otherwise
restricted in use or during installation.
•Ductwork is not provided with the dryer, and
you should obtain the necessary ductwork
locally. The end cap should have hinged
dampers to prevent backdraft when the dryer
is not in use. Failure to follow these instructions
can result in fire or death.
, The exhaust duct must be 4 inches (10.2
cm) in diameter with no obstructions. The
exhaust duct should be kept as short as
possible. Make sure to clean any old ducts
before installing your new dryer. Failure to
follow these instructions can result in fire or
death.
•Rigid or semi =rigid metal ducting is
recommended for use between the
dryer and the wall. in special installations
when it is impossible to make a connection
with the above recommendations, a UL=
listed flexible metal transition duct may be
used between the dryer and wall connection
only. The use of this ducting will affect drying
time. Failure to follow these instructions can
result in fire or death.
, DO NOT use sheet metal screws or other
fasteners which extend into the duct that
could catch lint and reduce the efficiency
of the exhaust system. Secure all joints with
duct tape. For complete details, follow the
Installation Instructions. Failure to follow these
instructions can result in fire or death.
SAFETY INSTRUCTIONS FOR STEAM FUNCTIONS
WARNING: to reduce the risk of fire, electric shock, or personal injury when using this
appliance, follow basic precautions, including the following:
Do not open the dryer door during steam
cycles. Failure to follow these instructions can
result in a burn hazard.
Do not dry articles that have been previously
cleaned in, washed in, soaked in, or spotted
with gasoline, dry=cleaning solvents, or other
flammable or explosive substances as they
give off vapors that could ignite or explode.
Failure to follow these instructions can result in
fire or death.
•Do not fill the steam feeder with gasoline,
dry=cleaning solvents, or other flammable or
explosive substances. Failure to follow these
instructions can result in fire or death.
Do not touch the steam nozzle in the drum
during or after the steam cycle. Failure to
follow these instructions can result in a burn
hazard.
•Do not fill the steam feeder with hot water
(over 86°F/30°C). Failure to follow these
instructions can result in a burn hazard.
6

iMPORTANTSAFETYiNSTRUCTiONS
READ ALL INSTRUCTIONS BEFORE USE
WARNING For your safety,the information in this manual must be
followed to minimize the risk of fire or explosion, electric shock, or to prevent
property damage, personal injury, or loss of life.
SAFETY iNSTRUCTiONS FOR CONNECTING ELECTRiCiTY
AWARNING: To reduce the risk of fire, electric shock, or personal injury when using this
appliance, follow basic precautions, including the following:
, Do not, under any circumstances, cut or
remove the ground prong from the power
cord. To prevent personal injury or damage to
the dryer, the electrical power cord must be
plugged into a properly grounded outlet.
, For personal safety, this dryer must be
properly grounded. Failure to do so can result
in electrical shock or injury.
•Refer to the installation instructions in this
manual for specific electrical requirements
for your model. Failure to follow these
instructions can create an electrical shock
hazard and/or a fire hazard.
• This dryer must be plugged into a properly
grounded outlet. Electrical shock can result if
the dryer is not properly grounded. Have the
wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly
grounded. Failure to follow these instructions
can create an electrical shock hazard and/or a
fire hazard.
• The dryer should always be plugged into
its own individual electrical outlet which
has a voltage rating that matches the rating
plate. This provides the best performance
and also prevents overloading house wiring
circuits which could cause a fire hazard from
overheated wires.
,Never unplug your dryer by pulling on the
power cord. Always grip plug firmly and pull
straight out from the outlet. The power cord
can be damaged, resulting in a risk of fire and
electrical shock.
•Repair or replace immediately all power
cords that have become frayed or otherwise
damaged. Do not use a cord that shows
cracks or abrasion damage along its length
or at either end. The power cord can melt,
creating electrical shock and/or fire hazard.
•When installing or moving the dryer, be
careful not to pinch, crush, or damage
the power cord. This will prevent injury and
prevent damage to the dryer from fire and
electrical shock.
SAVE THESE INSTRUCTIONS
7

PARTSANDFEATURES
SPECIAL FEATURES
O EASY-TO-USE CONTROL PANEL
Rotate the cycle selector knob to select the
desired dry cycle. Add cycle options or adjust
settings at the touch of a button.
_) EASY-ACCESS REVERSIBLE DOOR
Wide-opening door provides easy access for
loading and unloading. Door swing can be
reversed to adjust for installation location.
4{_ ULTRA-CAPACITY STAINLESS STEEL DRUM
WITH DRUM LIGHT
The ultra-large stainless steel drum offers
superior durability. The drum is equipped with a
light that illuminates when the dryer door is open
and turns off when the door is closed.
@STEAM FUNCTIONS
LG's steam technology allows you to inject
fabrics with a swirling jet of hot steam to refresh
clothes, reduce static, and make ironing easier.
Simply select the STEAMFRESH TMcycle, or you
can add a steam option to selected cycles.
FLOW SENSE TM DUCT BLOCKAGE SENSING
SYSTEM INDICATOR
The FLOW SENSF mduct blockage sensing
system detects and alerts you to blockages in
the ductwork that reduce exhaust flow from the
dryer. Clean exhaust systems increase efficiency
and reduce drying times. Protocol P154
Sanitization Performance of
Residential Clothes dryer
8

PARTSANDFEATURES
KEY PARTS AND COMPONENTS
In addition to the special features and
components outlined in the Special Features
section, there are several other important
components that are referenced in this manual.
OFRONT-MOUNT LINT FILTER
Front-mounted lint filter allows for easy access
and cleaning after every load.
LEVELING FEET
Four leveling feet (two in the front, and two in the back)
adjust to improve dryer stability on uneven floors,
ODRYING RACK
Usethe dryingrack with the RACKDRYcycleto safelydry
such itemsassweaters,delicatesand gym shoeswithout
tumbling or overheating.
Terminal Block
Access Panel Power Cord Location
(Electric 'Gas Models)
O
Included Accessories
Drying Rack , 7_;_,
Gas Exhaust Duct
Connection
Location Outlet
(Gas Models)
Rear of Dryer
9

INSTAllATION INSTRUCTIONS
iMPORTANT: Follow the operating and care instructions in this
manual and your dryer will provide many years of reliable service.
It is important that you review this entire manual before installing and using your dryer. Detailed instructions
concerning electrical connections, gas connections, and exhaust requirements are provided on the
following pages.
INSTALLATION LOCATION REOUIREMENTS
[] A location that allows for proper exhaust installation. [] A level floor with a maximum slope of 1 inch (2.5 cm)
A gas dryer must be exhausted to the outdoors. See
Venting Requirements.
[] A grounded electrical outlet located within 2 ft.
(61 cm) of either side of the dryer. See Electrical
Requirements.
[] A sturdy floor to support the total dryer weight of 200
Ibs (90.7 kg). The combined weight of a companion
appliance should also be considered.
[]
under entire dryer. If slope is greater than 1 inch (2.5
cm), install Extended Dryer Feet Kit. Clothes may not
tumble properly, and automatic sensor cycles may not
operate correctly if dryer is not level.
For a garage installation, you will need to place the dryer
at least 18 inches (46 cm) above the floor. If using a
pedestal, you will need 18 inches (46 cm) to the bottom
of the dryer.
Do not operate your dryer at temperatures below 45° F (7° C). At lower temperatures, the dryer might not shut off at the
end of an automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile
homes or sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.
CLEARANCES
_,._14"max.*.,
(35.6cm)
211/4"
(54cm)
457/16"
(iq5.3cm)
1"-_11_ 27"m_l _ 1"
(2.54 ore) (68.6 cm) (2.54 cm)
3"
(7.6 cm)
48 in.2
(310 cm2)
24in.2
(155cm2)
iO
I _ I
I_ 281%6" _ 1_5 ....
(73.4cm) (12.7 cm) 3" Closet Door Vent
_. 50 1/4" (7.6 cm) Requirements
_._ (127.5cm) /
installation spacing for recessed area or closet installation
The following spacing dimensions are recommended [] Additional spacing should be considered on all sides of
for this dryer. This dryer has been tested for spacing
of 0 inches (0 cm) clearance on the sides and rear.
Recommended spacing should be considered for the
following reasons:
[] Additional spacing should be considered for ease of
installation and servicing.
[] Additional clearances might be required for wall, door
and floor moldings.
[]
the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be
considered.
Suggestion: There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer
of vibration from one to the other. Too much vibration could cause them to make noise or touch each other, causing
paint damage and making even more noise.
10

INSTALLATIONINSTRU€TIONS
cLEARANcES (cont.)
IMPORTANT:If you are installing your dryer using an optional pedestal base or stacking kit,
please refer to Optional Accessories in this manual or to the instructions for your pedestal or
stacking kit before proceeding with the installation.
Recommended installation spacing for cabinet installation
[] For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet
are required.
(17,8 cm) 7"*(17,8cm) *Required spacing
**For side or bottom venting, 2" (5.1 cm)
spacing is allowed.
-T
olo
i
2815/ld_ 1'q,-I I_ 29/32"4 I_F 1"
(12.7cm) (73.4 cm)(2.5 cm) (2.54 cm) (68.6 cm) (2.54 cm)
LEVELINGTHE DRYER
WARNING To reducethe riskofpersonalinjury,adheretoallindustryrecommended safetyprocedures
includingtheuseoflongsleevedglovesandsafetyglasses.Failuretofollowallofthesafetywarningsinthis
manualcouldresultinpropertydamage,personalinjuryordeath.
To ensure that the dryer provides optimal drying
performance, it must be level. To minimize
vibration, noise, and unwanted movement, the
floor must be a level, solid surface.
NOTE: Adjust the leveling feet only as far as
necessary to level the dryer. Extending the
leveling feet more than necessary can cause
the dryer to vibrate.
Leveling Feet J
Position the dryer in the final location. Place
a level across the top of the dryer.
• All four leveling feet must rest solidly on the
floor. Gently push on the top corners of the
dryer to make sure that the dryer does not
rock from corner to corner.
Use an adjustable wrench to turn the leveling
feet. Turn clockwise to raise the dryer or
counterclockwise to lower it. Raise or lower
the leveling feet until dryer is level from
side to side and front to back.
Make sure that all 4 leveling feet are in firm
contact with the floor. 11

INSTALLATIONINSTRUCTIONS
REVERSING THE DOOR
................ _I 7 _
Open the door and remove the two plastic
hole caps on the catch side by gently prying
up with a flat blade screwdriver. Save these
for step 6.
Remove the 4 screws securing the hinges to
the door frame. Remove the two plastic cover
caps. Reinstall the hinges and cover caps on the
opposite sides from which they were removed.
rmm
r! H\_ !
! ,
--I I-- !
,J
With the hinges and cover caps in the new
locations, remount the inner door frame
onto the outer door frame with the screws
removed in step 3 above.
While supporting the door, remove the 4
screws, two from each hinge. Set the door
aside face down on a protected surface to
prevent damage to the door or the work
surface.
With the door on a protected surface,
remove the 12 screws on each side of the
door and lift off the inner door frame using
a flat blade screwdriver. Remove the latch
hook and blank and move them to the
opposite side.
Reinstall the door with the screws from step
1,2.
Test the swing of the door to make sure the
hinges and latch are properly aligned and that
the door closes and latches correctly.
12

INSTAllATION INSTRUCTIONS
cHANGiNG THE DRYER VENT LOcATiON
WARNING
= Use a heavy metal vent.
=Donot useplasticor thinfoil duct.
Cleanold ducts beforeinstallingthis dryer.
Protectyour handsandarms fromsharpedgeswhen
working insidethecabinet.
Toreducethe riskof personalinjury,adhereto all industry
recommendedsafetyproceduresincludingthe useof long
sleevedgloves andsafety glasses.Failureto follow all of
thesafety warningsinthis manualcould resultin property
damage,personalinjuryor death.
Your new dryer isshipped to vent to the rear.
It can also be configured to vent to the bottom or side
(right-side venting is not available on gas models).
An adapter kit, part number 383EEL9001B,
may be purchased from your LG retailer.This kit
contains the necessary duct components to change
the dryer vent location.
OPTION 1: Side venting
Adapter
Press the tabs on the knockout and carefully
remove the knockout for the desired vent opening
(right-side venting is not available on gas models).
Press the adapter duct onto the blower housing
and secure to the base of the dryer as shown.
Plate
Elbow
11/2"
(3.8 cm)
Preassemble a 4-inch (10 cm) elbow to the next
4-inch (10 cm) duct section, and secure all joints
with duct tape. Be sure that the male end of the
elbow faces AWAYfrom the dryer.
insert the elbow/duct assembly through the side
opening and press it onto the adapter duct.
Secure in place with duct tape.
Be sure that the male end of the duct protrudes
11/2inches (3.8cm) to connect the remaining
ductwork.
Attach cover plate to the back of the dryer with
included screw.
Retaining
Screw
Rear
Exhaust Duct
...... J
Remove the rear exhaust duct retaining
screw. Pull out the exhaust duct.
OPTION 2: BOttOm venting
Adapter
Bracket
Press the adapter duct onto the blower
housing and secure to the base of the dryer
as shown.
Plate
,ji
insert the 4-inch (10 cm) elbow through the
rear opening and press it onto the adapter
duct. Be sure that the male end of the elbow
faces down through hole in the bottom of the
dryer. Secure in place with duct tape.
Attach the cover plate to the back of the
dryer with included screw.
15

INSTALLATIONINSTRUCTIONS
VENTING THE DRYER
WARN|NG: To reduce the risk of fire, electric shock, or personal injury when using this
appliance, follow basic precautions, including the following:
•Do not crush or collapse ductwork. Failure
to follow these instructions can result in fire
or death.
•Do not allow ductwork to rest on or
contact sharp objects. Failure to follow these
instructions can result in fire or death.
•If connecting to existing ductwork, make
sure it is suitable and clean before installing
the dryer. Failure to follow these instructions
can result in fire or death.
• Venting must conform to local building
codes. Failure to follow these instructions can
result in fire or death.
Gas dryers MUST exhaust to the outdoors.
Failure to follow these instructions can result
in fire or death.
• Use only 4=inch {10.2 cm} rigid or flexible
metal ductwork inside the dryer cabinet and
for venting outside. Failure to follow these
instructions can result in fire or death.
, To reduce the risk of fire, combustion, or
accumulation of combustible gases, DO
NOT exhaust dryer air into an enclosed and
unventilated area, such as an attic, wall,
ceiling, crawl space, chimney, gas vent, or
concealed space of a building. Failure to
follow these instructions can result in fire
or death.
• To reduce the risk of fire, DO NOT exhaust
the dryer with plastic or thin foil ducting.
Failure to follow these instructions can result
in fire or death.
• The exhaust duct must be 4 inches (10.2
cm} in diameter with no obstructions. The
exhaust duct should be kept as short as
possible. Make sure to clean any old ducts
before installing your new dryer. Failure to
follow these instructions can result in fire or
death.
,Rigid or semirigid metal ducting is
recommended for use between the dryer
and the wall. in special installations when
it is impossible to make a connection with
the above recommendations, a UL=listed
flexible metal transition duct may be used
between the dryer and wall connection only.
The use of this ducting will affect drying
time. Failure to follow these instructions can
result in fire or death.
DO NOT use sheet metal screws or other
fasteners which extend into the duct that
could catch lint and reduce the efficiency
of the exhaust system. Secure all joints
with duct tape. Failure to follow these
instructions can result in fire or death.
• To maximize operating results, please
observe the duct length limitations noted in
the chart on page 15. Failure to follow these
instructions can result in fire or death.
Ductwork is not provided with the dryer.
You should obtain the necessary ductwork
locally. The end cap should have hinged
dampers to prevent backdraft when the
dryer is not in use. Failure to follow these
instructions can result in fire or death.
• The Total length of flexible metal duct shall
not exceed 8 ft. (2.4m)
• in Canada, that only those foil-type flexible
ducts, if any, specifically identified for use
with the appliance by the manufacturer
shall be used. In the United States, that only
those foil-type flexible ducts, if any, specifically
identified for use with the appliance by the
manufacturer and that comply with the outline
for Clothes Dryer Transition Duct, Subject
2158A, shall be used.
14

INSTAllATION INSTRU€TIONS
VENTING THE DRYER (cont.)
DuCtwork
Recommended
(10.2 cm) (10.2 ore)
Use Only for Short
Run Installations
(6.35 cm)
0
1
2
3
4
0
1
2
3
4
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (13.7 m)
36 ft. (11.0 m)
28ft._
55 ft. (16.8 m)
47 ft. (13.7 m)
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)
NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended to use more than four 90° elbows.
ROuting and Connecting Ductwork
Follow the guidelines below to maximize drying
performance and reduce lint buildup and
condensation in the ductwork,
NOTE: Ductwork and fittings are NOT included
and must be purchased separately.
• Use 4-inch (10,2 cm) diameter rigid or semirigid
metal ductwork,
• The exhaust duct run should be as short as
possible,
• Use as few elbow joints as possible.
• The male end of each section of exhaust duct
must point away from the dryer.
• Use duct tape on all duct joints,
• Insulate ductwork that runs through unheated
areas in order to reduce condensation and lint
buildup on duct surfaces.
iMPORTANT: Failure to exhaust the dryer
correctly will void the dryer's warranty.
Correct Venting
incorrect Venting
15

INSTALLATIONINSTRUCTIONS
cONNEcTiNG GAS DRYERS
_W_ILRN|NG -u To reduce the risk of fire, electric shock, or personal injury when using this
appliance, follow basic precautions, including the following:
, Gas supply requirements:
As shipped from the factory, this dryer is
configured for use with natural gas. it can be
converted for use with LP {Liquefied Propane)
gas. Gas pressure must not exceed 13 inches
of water column.
, A qualified service or gas company technician
must connect the dryer to the gas service.
Failure to do so can result in fire, explosion,
or death.
Isolate the dryer from the gas supply system
by closing its individual manual shutoff valve
during any pressure testing of the gas supply.
Failure to do so can result in fire, explosion,
or death.
. Supply line requirements:
Your laundry room must have a rigid gas
supply line to your dryer, in the United States,
an individual manual shutoff valve MUST be
installed within at least 6 ft. (1.8 m) of the dryer,
in accordance with the National Fuel Gas Code
ANSI Z223.1 or Canadian gas installation code
CSA B149.1. A 1/8- inch NPT pipe plug must
be installed. Failure to do so can result in fire,
explosion, or death
. If using a rigid pipe, the rigid pipe should be
1/2- inch IPS. if acceptable under local codes
and ordinances and when acceptable to your
gas supplier, 3/8- inch approved tubing may be
used where lengths are less than 20 ft.
(6.1 m). Larger tubing should be used for
lengths in excess of 20 ft. (6.1 m). Failure to do
so can result in fire, explosion, or death.
Connect the dryer to the type of gas shown on
the nameplate. Failure to do so can result in fire,
explosion, or death.
, To prevent contamination of the gas valve,
purge the gas supply of air and sediment
before connecting the gas supply to the dryer.
Before tightening the connection between the
gas supply and the dryer, purge remaining air
until the odor of gas is detected. Failure to do
so can result in fire, explosion, or death.
DO NOT use an open flame to inspect for gas
leaks. Use a noncorrosive leak-detection fluid.
Failure to do so can result in fire, explosion, or
death.
, Use only anew AGA- or CSA-certified gas
supply line with flexible stainless steel
connectors. Failure to do so can result in fire,
explosion, or death.
* Securely tighten all gas connections. Failure
to do so can result in fire, explosion, or death.
. Use Teflon ®tape or a pipe-joint compound that
is insoluble in Liquefied Petroleum {LP) gas on
all pipe threads. Failure to do so can result in fire,
explosion, or death.
DO NOT attempt any disassembly of the dryer;
any disassembly requires the attention and
tools of an authorized and qualified service
person or company. Failure to do so can result
in fire, explosion, or death.
Electrical Requirements for Gas MOdelS Only
WARN|N6: To reduce the risk of fire, electric shock, or personal injury when using this
appliance, follow basic precautions, including the following:
, Do not, under any circumstances, cut or
remove the third {ground) prong from the power
cord. Failure to follow this warning can result in
fire, explosion, or death.
For personal safety, this dryer must be properly
grounded. Failure to follow this warning can result
in fire, explosion, or death.
The power cord of this dryer is equipped with
a 3-prong {grounding) plug which mates with
a standard 3-prong {grounding) wall outlet
to minimize the possibility of electric shock
hazard from this appliance. Failure to follow this
warning can result in fire, explosion, or death.
•This dryer must be plugged into a
20-amp, 120 VAC. grounded outlet protected by
a15-ampere fuse or circuit breaker. Failure to
follow this warning can result in fire, explosion,
or death.
•Where a standard 2-prong wall outlet is
encountered, it is your personal responsibility
and obligation to have it replaced with a
properly grounded 3-prong wall outlet. Failure
to follow this warning can result in fire, explosion,
or death.
16

INSTALLATIONINSTRUCTIONS
CONNECTING GAS DRYERS (cont.)
WARNING:
appliance, follow basic precautions, including the following:
•installation and service must be performed
by a qualified installer, service agency, or the
gas supplier. Failure to do so can result in fire,
explosion, or death.
•Use only a new stainless steel flexible
connector and a new AGA=certified
connector. Failure to do so can result in fire,
explosion, or death.
• A gas shutoff valve must be installed within
6 ft. (1.8 m) of the dryer. Failure to do so can
result in fire, explosion, or death.
•The dryer is configured for Natural Gas when
shipped from the factory. Make sure that the
dryer is equipped with the correct burner
orifice for the type of gas being used (Natural
Gas or Liquefied Petroleum). Failure to do so
can result in fire, explosion, or death.
To reduce the risk of fire, electric shock, or personal injury when using this
If necessary, the correct orifice (for the
LP conversion kit order part number
4948EL4002B) should be installed by a
qualified technician and the change should
be noted on the dryer. Failure to do so can
result in fire, explosion, or death.
All connections must be in accordance with
local codes and regulations. Failure to do so
can result in fire, explosion, or death.
Gas dryers MUST exhaust to the outdoors.
Failure to do so can result in fire, explosion,
or death.
Connecting the Gas Supply
O Make sure that the gas supply to the laundry
room is turned OrE Confirm that the type
of gas available in your laundry room is
appropriate for the dryer. The dryer is
prepared for Natural Gas with a %- inch NPT
gas connection.
O Remove the shipping cap from the gas
connection at the back of the dryer. Be
careful not to damage the threads of the gas
connector when removing the shipping cap.
Connect the dryer to your laundry room's gas
supply using a new flexible stainless steel
connector with a % - inch NPT fitting.
_1 Securely tighten all connections between the
dryer and your laundry room's gas supply.
Turn on your laundry room's gas supply and
check all pipe connections (both internal and
external) for gas leaks with a noncorrosive
leak-detection fluid.
Electrical Connection
Plug dryer into a
120=VAC, 60-Hz.
grounded 3-prong
outlet.
Stainless Steel
Flexible Connector
J
Hig#-Altitude Installations
The BTU rating of this dryer is AGA-certified for
elevations below 10,000 feet.
If your gas dryer is being installed at an elevation
above 10,000 feet, it must be derated by a
qualified technician or gas supplier.
17

INSTALLATIONINSTRU€TIONS
cONNEcTiNG ELEcTRic DRYERS
_WARN|_I_G -= To help prevent fire, electric shock, serious injury, or death, the wiring and
grounding must conform to the latest edition of the National Electrical Code, ANSI/NFPA 70 and all
applicable local regulations. Please contact a qualified electrician to check your home's wiring and
fuses to ensure that your home has adequate electrical power to operate the dryer.
Electrical Requirements for Electric MOdelS Only
WARN|NG: To reduce the risk of fire, electric shock, or personal injury when using this
appliance, follow basic precautions, including the following:
•This dryer must be connected to a grounded
metal, permanent wiring system, or an
equipment=grounding conductor must
be run with the circuit conductors and
connected to the equipment=grounding
terminal or lead on the dryer. Failure to do
so can result in fire, explosion, or death.
•The dryer has its own terminal block that
must be connected to a separate 240 VAC,
60 Hertz, single=phase circuit, fused at 30
amperes (the circuit must be fused on both
sides of the line). ELECTRICAL SERVICE
FOR THE DRYER SHOULD BE OF THE
MAXIMUM RATE VOLTAGE LISTED ON THE
NAMEPLATE. DO NOT CONNECT DRYER TO
110=, 115=, OR 120=VOLT CIRCUIT. Heating
elements are available for field installation
in dryers which are to be connected to an
electrical service of a different voltage than
that listed on the rating plate. Failure to follow
these instructions can result in fire, explosion,
or death.
if branch circuit to dryer is 15 ft. (4.5 m)
or less in length, use UL (Underwriters
Laboratories) listed No. 10 AWG wire
(copper wire only), or as required by local
codes. If over 15 ft. (4.50 m), use UL=listed
No.=8 AWG wire (copper wire only), or as
required by local codes. Allow sufficient
slack in wiring so dryer can be moved from
its normal location when necessary. Failure
to do so can result in fire, explosion, or death.
The power cord (pigtail) connection between
wall receptacle and dryer terminal block
IS NOT supplied with dryer. Type of pigtail
and gauge of wire must conform to local
codes and with instructions on the following
pages. Failure to follow these instructions can
result in fire, explosion, or death.
A 4-wire connection is required for all mobile
and manufactured home installations, as
well as all new construction after January
1, 1996. A 4=wire connection must be used
where local codes do not permit grounding
through the neutral wire. Failure to do so can
result in fire, explosion, or death.
_WAR_I_I_|NG= = To reduce the risk of fire, electric shock, or personal injury when using this
appliance, follow basic precautions, including the following:
•Do not modify the plug and internal wire
provided with the dryer.
•The dryer should be connected to a 4-hole
outlet.
•if it does not fit the outlet, a proper outlet will
need to be installed by a qualified electrician.
Special Electrical Requirements for Mobile or Manufactured Homes
_I_W_I_R_!I_ | _I!_G --" TOreduce the risk of fire, electric shock, or personal injury when using this
appliance, follow basic precautions, including the following:
=Any installation in a manufactured or mobile
home must comply with the Manufactured
Home Construction and Safety Standards
Title 24 CFR, Part 32-80 or Standard CAN/
CSAOZ240 MH and local codes and ordinances.
•A 4-wire connection is required for all mobile
and manufactured home installations, as well
as all new construction after January 1, 1996.
Failure to do so can result in fire, explosion,
or death.
18

INSTAllATIONINSTRU€TIONS
cONNEcTiNG ELEcTRic DRYERS {cont.)
USA ONLY
WARN|NG:
=Connect the power cord to the terminal block. Each colored wire should be connected
to same color screw. Wire color indicated on manual is connected to the same color
screw in block. Failure to follow these instructions may result in a short or overload.
=Grounding through the neutral conductor is prohibited for: (1) new branch-circuit
installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local
codes prohibit grounding through the neutral conductor.
Four-wire Connection for Electric Dryers: Power Cord
• A 4-wire connection is required for all mobile
and manufactured home installations, as well
as all new construction after January 1, 1996.
A UL-listed strain relief is required.
Use a 30-amp, 240V, UL=listed power cord
with #10 AWG=minimurn copper conductor
and closed loop or forked terminals with
upturned ends.
Terminal
Block
UL-Listed
Strain Relief
UL-Listed
4-Wire
Power Cord
Remove the terminal block access cover
on the upper back of the dryer. Install a
UL-Iisted strain relief into the power cord
through-hole; then thread a UL-Iisted, 30A,
240V, 4-wire, #10 AWG=minirnurn copper
conductor power cord through the
strain relief.
Transfer the dryer's ground wire from behind
the green ground screw to the center screw
of the terminal block. Attach the two hot
leads of the power cord to the outer terminal
block screws. Attach the white neutral wire
to the center terminal block screw. Attach the
power cord ground wire to the green ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover.
19

INSTALLATIONINSTRU€TIONS
cONNEcTiNG ELEcTRic DRYERS {cont.)
USA ONLY
WARN|NG:
• Connect the power cord to the terminal block. Each colored wire should be connected to
same color screw. Wire color indicated on manual is connected to the same color screw
in block. Failure to follow these instructions may result in a short or overload.
• Grounding through the neutral conductor is prohibited for: (1) new branch-circuit
installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes
prohibit grounding through the neutral conductor.
Four-wire Connection for Electric Dryers: Direct wire
•A 4-wire connection is required for all mobile
and manufactured home installations, as well
as all new construction after January 1, 1996.
•A UL-listed strain relief is required.
•Use UL-Iisted 4-wire #10 AWG=minirnurn
copper conductor cable.
•Allow at least 5 ft. (1.5 m) length to allow for
removal and reinstallation of the dryer.
5 II
(12.7 cm)
Ground Wire
Remove 5 inches (12.7 cm) of the outer
covering from the wire. Remove 5 inches
of insulation from the ground wire. Cut off
approximately 11/2inches (3.8 cm) from the
other three wires and strip 1 inch (2.5 cm)
insulation from each wire. Bend the ends of
the three shorter wires into a hook shape.
Terminal
Block
UL-Listed
Strain Relief
Ground Screw
.............. (White) Hot
(Red)
Ground
Wire
Transfer the dryer's ground wire from behind
the green ground screw to the center screw
of the terminal block. Attach the two hot
leads of the power cable to the outer terminal
block screws. Attach the white neutral wire
to the center terminal block screw. Attach the
power cable ground wire to the green ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover.
UL-Listed
4-Wire
Power Cord
Remove the terminal block access cover
on the upper back of the dryer. Install a
UL-listed strain relief into the power cord
opening; then thread the power cable
prepared in Step 1 through the strain relief.
2O
Other manuals for DLGX5102V
1
This manual suits for next models
3
Table of contents
Languages:
Other LG Dryer manuals

LG
LG DLG4902 Series User manual

LG
LG SteamDryer DLGX2502W Instruction Manual

LG
LG DLEX4500 Series User manual

LG
LG DLE3733S User manual

LG
LG RC9011G2 User manual

LG
LG DLE2140 Series User manual

LG
LG DlG1502 series User manual

LG
LG RN1329AD5 User manual

LG
LG DLEC855W User manual

LG
LG SteamDryer DLGX2651R User manual
Popular Dryer manuals by other brands

Power
Power PW-70-3 instruction manual

Hotpoint Ariston
Hotpoint Ariston Aqualtis AQCF851BUEU Service information

Kenmore
Kenmore Dryer user guide

Dexter Laundry
Dexter Laundry T-80 Operators manual installation & operation instructions

Samsung
Samsung DVG52M8650V user manual

Hyco
Hyco BLADE Product instruction manual