LG SteamDryer DLEX6001V User manual

OWNER’S MANUAL
TOUCH SCREEN DRYER
DLEX6001W
DLGX6002W
DLEX6001V
DLGX6002V
Before beginning installation, read these instructions carefully. This will
simplify installation and ensure that the dryer is installed correctly and
safely. Leave these instructions near the dryer after installation for
future reference.
P/No. : MFL62512858 www.lg.com
ENGLISH ESPAÑOL

2
SPECIAL FEATURE
TOUCH SCREEN LCD DISPLAY
The full color touch screen LCD control displays all cycle, setting, progress and control information.
Selections, navigation and adjustments are made by touching the icons on the screen for the desired actions.
SMART THINQ
SMART DIAGNOSIS™ - Should you experience technical difficulty, your appliance has the capability of transmitting data by phone to the
Customer Information Center to diagnosis the problem.
SMART ACCESS - Monitor your cycle operation so you know how much time is left in the cycle. You can even shut the machine off if you
need to.
SMART ADAPT - Download new and special cycles that are not included with the machine.
Smart Grid - Smart appliances can communicate with local utility companies that are equipped with Smart Grid equipment.
SMART MESSAGE - When the cycle is complete or the appliance has problems, you have the option of receiving push notifications on your
smart phone. (Refer to the modem manual for detailed information on Smart ThinQ.)
LARGE CAPACITY STAINLESS STEEL DRUM
The ultra-large stainless steel drum offers superior durability.
EASY-ACCESS REVERSIBLE DOOR
The wide-opening, see-through glass door provides easy access for loading and unloading. Door swing can be reversed to adjust for
installation location.
STEAM FUNCTIONS
LG’s steam technology allows you to inject fabrics with a swirling jet of hot steam to refresh clothes, reduce static, and make ironing
easier. Simply select the STEAMFRESH™ cycle, or you can add a steam option to selected cycles.
SPECIAL FEATURES
Protocol P154
Sanitization Performance of
Residential Clothes dryer
C
E
R
T
I
F
I
E
D
D
E
S
I
G
N
NOTE
Only LG USBs will work with your LG appliance.

3
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
WWARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to
prevent property damage, injury to persons, death.
Your Safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word DANGER, WARNING or CAUTION.
These words mean:
WDANGER
You will be killed or seriously injured if you don’t immediately follow instructions.
WWARNING
You can be killed or seriously injured if you don’t follow instructions.
WCAUTION
You may be slightly injured or cause damage to the product if you do not follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if
the instructions are not followed.
t%POPUJOTUBMMBDMPUIFTESZFSXJUIGMFYJCMFQMBTUJDWFOUJOHNBUFSJBMT*GGMFYJCMFNFUBMGPJMUZQFEVDUJTJOTUBMMFEJUNVTUCFPG
a specific type identified by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are
known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of
fire.
t%POPUTUPSFPSVTFHBTPMJOFPSPUIFSGMBNNBCMFWBQPSTBOEMJRVJETJOUIFWJDJOJUZPGUIJTBQQMJBODFPSBOZPUIFSBQQMJBODFT
t*OTUBMMBUJPOBOETFSWJDFNVTUCFQFSGPSNFECZBRVBMJGJFEJOTUBMMFSTFSWJDFBHFODZPSUIFHBTTVQQMJFS
t*OTUBMMUIFDMPUIFTESZFSBDDPSEJOHUPUIFNBOVGBDUVSFSTJOTUSVDUJPOTBOEMPDBMDPEFT
t4BWFUIFTFJOTUSVDUJPOT
8)"550%0*':064.&--("4
%POPUUSZUPMJHIUBNBUDIPSDJHBSFUUFPSUVSOPOBOZHBTPSFMFDUSJDBMBQQMJBODF
%POPUUPVDIBOZFMFDUSJDBMTXJUDIFT%POPUVTFBOZQIPOFJOZPVSCVJMEJOH
3. Clear the room, building, or area of all occupants.
*NNFEJBUFMZDBMMZPVSHBTTVQQMJFSGSPNBOFJHICPSTQIPOF'PMMPXUIFHBTTVQQMJFSTJOTUSVDUJPOTDBSFGVMMZ
*GZPVDBOOPUSFBDIZPVSHBTTVQQMJFSDBMMUIFGJSFEFQBSUNFOU
W
IMPORTANT SAFETY INSTRUCTIONS

4
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
WWARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to
prevent property damage, injury to persons, death.
#"4*$4"'&5:13&$"65*0/4
WWARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the
GPMMPXJOH
$"-*'03/*"4"'&%3*/,*/(8"5&3"/%509*$&/'03$&.&/5"$5
This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects, or other
reproductive harm and requires businesses to warn customers of potential exposure to such substances.
Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde, and soot, caused
primarily by the incomplete combustion of natural gas or LP fuels.
Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be minimized further by properly
venting the dryer to the outdoors.
4"'&5:*/4536$5*0/4'0345&".'6/$5*0/4
WWARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the
GPMMPXJOH
t3FBEBMMJOTUSVDUJPOTCFGPSFVTJOHUIFESZFS
tBefore use, the dryer must be properly installed as described
in this manual.
t%POPUQMBDFJUFNTFYQPTFEUPDPPLJOHPJMTJOZPVSESZFSItems
contaminated with cooking oils may contribute to a chemical
reaction that could cause a load to catch fire.
t%POPUESZBSUJDMFTUIBUIBWFCFFOQSFWJPVTMZDMFBOFEJO
washed in, soaked in, or spotted with gasoline, dry-cleaning
solvents, or other flammable or explosive substances as they
give off vapors that could ignite or explode.
t%POPUSFBDIJOUPUIFESZFSJGUIFESVNPSBOZPUIFSQBSUJT
moving.
t%POPUSFQBJSPSSFQMBDFBOZQBSUPGUIFESZFSPSBUUFNQUBOZ
TFSWJDJOHVOMFTTTQFDJGJDBMMZSFDPNNFOEFEJOUIJT6TFBOE
$BSF(VJEFPSJOQVCMJTIFEVTFSSFQBJSJOTUSVDUJPOTUIBUZPV
understand and have the skills to carry out.
t%POPUUBNQFSXJUIDPOUSPMT
tBefore the dryer is removed from service or discarded, remove
the door to the drying compartment.
t%POPUBMMPXDIJMESFOUPQMBZPOPSJOUIFESZFS Close
supervision of children is necessary when the dryer is used near
children.
t%POPUVTFGBCSJDTPGUFOFSTPSQSPEVDUTUPFMJNJOBUFTUBUJD
unless recommended by the manufacturer of the fabric
softener or product.
t%POPUVTFIFBUUPESZBSUJDMFTDPOUBJOJOHGPBNSVCCFSPS
similarly textured rubber-like materials.
t,FFQBSFBBSPVOEUIFFYIBVTUPQFOJOHBOEBEKBDFOU
surrounding areas free from the accumulation of lint, dust,
and dirt.
tThe interior of the dryer and exhaust vent should be cleaned
QFSJPEJDBMMZCZRVBMJGJFETFSWJDFQFSTPOOFM
t%POPUJOTUBMMPSTUPSFUIFESZFSXIFSFJUXJMMCFFYQPTFEUP
the weather.
tAlways check the inside of the dryer for foreign objects.
tClean lint screen before or after each load.
t%POPUTUPSFQMBTUJDQBQFSPSDMPUIJOHUIBUNBZCVSOPSNFMU
on top of the dryer during operation.
IMPORTANT SAFETY INSTRUCTIONS
t%POPUPQFOUIFESZFSEPPSEVSJOHTUFBNDZDMFTFailure to
follow these instructions can result in a burn hazard.
t%POPUESZBSUJDMFTUIBUIBWFCFFOQSFWJPVTMZDMFBOFEJO
washed in, soaked in, or spotted with gasoline, dry-cleaning
solvents, or other flammable or explosive substances as they
give off vapors that could ignite or explode. Failure to follow
UIFTFJOTUSVDUJPOTDBOSFTVMUJOGJSFPSEFBUI%POPUGJMMUIF
steam feeder with gasoline, dry-cleaning solvents, or other
flammable or explosive substances. Failure to follow these
instructions can result in fire or death.
t%POPUUPVDIUIFTUFBNOP[[MFJOUIFESVNEVSJOHPSBGUFSUIF
steam cycle. Failure to follow these instructions can result in a
burn hazard.
t%POPUGJMMUIFTUFBNGFFEFSXJUIIPUXBUFSPWFS¡'¡$
Failure to follow these instructions can result in a burn hazard.

5
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
WWARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to
prevent property damage, injury to persons, death.
(306/%*/(*/4536$5*0/4
WWARNING
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or
service person if you are in doubt that the appliance is properly grounded.
4"'&5:*/4536$5*0/4'03*/45"--"5*0/
WWARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
t1SPQFSMZHSPVOEESZFSUPDPOGPSNXJUIBMMHPWFSOJOHDPEFT
and ordinances. Follow details in the installation instructions.
Electric shock can result if the dryer is not properly grounded.
tBefore use, the dryer must be properly installed as described
in this manual. Electric shock can result if the dryer is not properly
grounded.
t*OTUBMMBOETUPSFUIFESZFSXIFSFJUXJMMOPUCFFYQPTFEUP
temperatures below freezing or exposed to the weather.
tAll repairs and servicing must be performed by an authorized
TFSWJDFSVOMFTTTQFDJGJDBMMZSFDPNNFOEFEJOUIJT0XOFST
(VJEF6TFPOMZBVUIPSJ[FEGBDUPSZQBSUTFailure to follow this
warning can cause serious injury, fire, electric shock, or death.
tTo reduce the risk of electric shock, do not install the dryer in
humid spaces. Failure to follow this warning can cause serious
injury, fire, electric shock, or death.
tConnect to a properly rated, protected, and sized power
circuit to avoid electrical overload. Improper power circuit can
melt, creating electric shock and/or fire hazard.
t3FNPWFBMMQBDLJOHJUFNTBOEEJTQPTFPGBMMTIJQQJOH
materials properly. Failure to do so can result in death, explosion,
fire, or burns.
t1MBDFESZFSBUMFBTUJODIFTBCPWFUIFGMPPSGPSBHBSBHF
installation. Failure to do so can result in death, explosion, fire, or
burns.
t,FFQBMMQBDLBHJOHGSPNDIJMESFO Packaging material can be
dangerous for children. There is a risk of suffocation.
t%POPUJOTUBMMOFBSBOPUIFSTPVSDFPGIFBUTVDIBTBTUPWF
cooking oven. Failure to do so can cause deform, smoke and fire.
t%POPUQMBDFDBOEMFTTNPLJOHNBUFSJBMTPSPUIFSGMBNNBCMFT
on top of the product. Dripping wax, smoke, or fire can result.
t3FNPWFBMMQSPUFDUJWFWJOZMGJMNGSPNUIFQSPEVDUFailure to do
so can cause product damage, smoke or fire.
This appliance must be grounded. In the event of malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current. This
appliance must be equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
Do not modify the plug provided with the appliance. If it will not fit
the outlet, have a proper outlet installed by a qualified electrician.
This appliance must be connected to a grounded metal, permanent
wiring system or an equipment-grounding conductor must be
run with the circuit conductors and connected to the equipment-
grounding terminal or lead on the appliance.
Electric shock can result if the dryer is not properly grounded.
IMPORTANT SAFETY INSTRUCTIONS

6
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
WWARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to
prevent property damage, injury to persons, death.
4"'&5:*/4536$5*0/4'03*/45"--"5*0/
WWARNING
To reduce the risk of injury to persons, follow all industry recommended safety procedures including the use of long sleeved gloves and
safety glasses. Failure to follow all of the safety warnings in this manual could result in property damage, injury to persons or death.
Exhaust/Ducting:
t(BTESZFST.645CFFYIBVTUFEUPUIFPVUTJEF Failure to follow
these instructions can result in fire or death.
tThe dryer exhaust system must be exhausted to the outside of
UIFEXFMMJOH*GUIFESZFSJTOPUFYIBVTUFEPVUEPPSTTPNFGJOF
lint and large amounts of moisture will be expelled into the
laundry area. An accumulation of lint in any area of the home can
create a health and fire hazard.
t6TFPOMZSJHJENFUBMPSGMFYJCMFNFUBMJODIEJBNFUFS
ductwork inside the dryer cabinet or for exhausting to the
PVUTJEF6TFPGQMBTUJDPSPUIFSDPNCVTUJCMFEVDUXPSLDBO
cause a fire. Punctured ductwork can cause a fire if it collapses or
becomes otherwise restricted in use or during installation.
t%VDUXPSLJTOPUQSPWJEFEXJUIUIFESZFSBOEZPVTIPVME
obtain the necessary ductwork locally. The end cap should
have hinged dampers to prevent backdraft when the dryer is
not in use. Failure to follow these instructions can result in fire or
death.
t5IFFYIBVTUEVDUNVTUCFJODIFTDNJOEJBNFUFSXJUI
no obstructions. The exhaust duct should be kept as short as
QPTTJCMF.BLFTVSFUPDMFBOBOZPMEEVDUTCFGPSFJOTUBMMJOH
your new dryer. Failure to follow these instructions can result in
fire or death.
t3JHJEPSTFNJSJHJENFUBMEVDUJOHJTSFDPNNFOEFEGPSVTF
CFUXFFOUIFESZFSBOEUIFXBMM*OTQFDJBMJOTUBMMBUJPOT
when it is impossible to make a connection with the above
SFDPNNFOEBUJPOTB6-MJTUFEGMFYJCMFNFUBMUSBOTJUJPOEVDU
may be used between the dryer and wall connection only.
The use of this ducting will affect drying time. Failure to follow
these instructions can result in fire or death.
t%0/05VTFTIFFUNFUBMTDSFXTPSPUIFSGBTUFOFSTXIJDI
extend into the duct that could catch lint and reduce the
efficiency of the exhaust system. Secure all joints with duct tape.
For complete details, follow the Installation Instructions. Failure to
follow these instructions can result in fire or death.
IMPORTANT SAFETY INSTRUCTIONS

7
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
WWARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to
prevent property damage, injury to persons, death.
4"'&5:*/4536$5*0/4'03$0//&$5*/(&-&$53*$*5:
WWARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
4"7&5)&4&*/4536$5*0/4
t%POPUVOEFSBOZDJSDVNTUBODFTDVUPSSFNPWFUIFHSPVOE
prong from the power cord. To prevent injury to persons or
damage to the dryer, the electrical power cord must be plugged
into a properly grounded outlet.
tFor personal safety, this dryer must be properly grounded.
Failure to do so can result in electric shock or injury.
t3FGFSUPUIFJOTUBMMBUJPOJOTUSVDUJPOTJOUIJTNBOVBMGPSTQFDJGJD
FMFDUSJDBMSFRVJSFNFOUTGPSZPVSNPEFM Failure to follow these
instructions can create an electric shock hazard and/or a fire
hazard.
tThis dryer must be plugged into a properly grounded outlet.
&MFDUSJDTIPDLDBOSFTVMUJGUIFESZFSJTOPUQSPQFSMZHSPVOEFE
)BWFUIFXBMMPVUMFUBOEDJSDVJUDIFDLFECZBRVBMJGJFE
electrician to make sure the outlet is properly grounded.
Failure to follow these instructions can create an electric shock
hazard and/or a fire hazard.
tThe dryer should always be plugged into its own individual
electrical outlet which has a voltage rating that matches
the rating plate. This provides the best performance and also
prevents overloading house wiring circuits which could cause a
fire hazard from overheated wires.
t/FWFSVOQMVHZPVSESZFSCZQVMMJOHPOUIFQPXFSDPSE"MXBZT
grip plug firmly and pull straight out from the outlet. The
power cord can be damaged, resulting in a risk of fire and electric
shock.
t3FQBJSPSSFQMBDFJNNFEJBUFMZBMMQPXFSDPSETUIBUIBWF
CFDPNFGSBZFEPSPUIFSXJTFEBNBHFE%POPUVTFBDPSEUIBU
shows cracks or abrasion damage along its length or at either
end. The power cord can melt, creating an electric shock and/or
fire hazard.
tWhen installing or moving the dryer, be careful not to pinch,
crush, or damage the power cord. This will prevent injury and
prevent damage to the dryer from fire and electric shock.
IMPORTANT SAFETY INSTRUCTIONS

8
TABLE OF CONTENTS
2SPECIAL FEATURES
3IMPORTANT SAFETY INSTRUCTIONS
3 WHAT TO DO IF YOU SMELL GAS
4 BASIC SAFETY PRECAUTIONS
4 CALIFORNIA SAFE DRINKING WATER AND TOXIC
ENFORCEMENT ACT
4 SAFETY INSTRUCTIONS FOR STEAM
FUNCTIONS
5 GROUNDING INSTRUCTIONS
5 SAFETY INSTRUCTIONS FOR INSTALLATION
7 SAFETY INSTRUCTIONS FOR CONNECTING
ELECTRICITY
9
PARTS AND FEATURES
9 COMPONENTS
10 LCD SCREEN INTROCUTION
11 CYCLE INFORMATION SCREENS
12 INSTALLATION INSTRUCTIONS
12 PREVIEW INSTALLATION ORDER
13 INSTALLATION LOCATION REQUIREMENTS
13 CLEARANCES
14 LEVELING THE DRYER
15 REVERSING THE DOOR
16 CHANGING THE DRYER VENT LOCATION
17 VENTING THE DRYER
19 CONNECTING GAS DRYERS
21 CONNECTING ELECTRIC DRYERS
26 SPECIAL REQUIREMENTS FOR MANUFACTURED
OR MOBILE HOMES
26 FINAL INSTALLATION CHECK
27 INSTALLATION TEST(EXHAUST CHECK)
29 HOW TO USE
29 BASIC OPERATION
30 CYCLE GUIDE
32 SORTING LOAD
32 LOADING THE DRYER
32 CHECK THE LINT FILTER BEFORE EVERY LOAD
33 CYCLE SETTINGS BUTTONS
34 TIME AND STATUS SCREEN
35 MENU OPTIONS BUTTONS AND SCREENS
37 CYCLE OPTIONS AND SPECIAL FEATURES
38 FILLNG THE STEAM FEEDER
40 SMART APPLIANCE CONNECTIVITY
40 SMART THINQ OPERATION
41 CONNECTIVITY OVERVIEW
- PROFILE SETUP(ID AND PASSWORD SETUP)
42 CONNECTIVITY SETUP
- WI-FI SETUP
- PRODUCT REGISTRATION
- ZIGBEE
- SMART GRID
43 SMART THINQ
- SMART ADAPT
- CYCLE DOWNLOAD USING WI-FI OR USB
- UPLOADING CYCLE TO THE USB DRIVE
44 SOFTWARE UPDATE
44 LG SMART APPLIANCE APPLICATION FOR
SMART PHONES
- SMART DIAGNOSIS™
- SMART ACCESS
- SMART ADAPT
- SMART MANAGER
45 MAINTENANCE
45 REGULAR CLEANING
46 TROUBLESHOOTING GUIDE
46 BEFORE CALLING FOR SEVICE
47 SPECIFICATIONS
48 SMART DIAGNOSIS™ SYSTEM
49 OPEN SOURCE SOFTWARE NOTICE
50 WARRANTY
TABLE OF CONTENTS

9
ENGLISH
PARTS AND FEATURES
PARTS AND FEATURES
Components
INCLUDED ACCESSORIES
Terminal Block
Access Panel
(Electric Models)
Gas Connection
Location
(Gas Models)
Exhaust Duct
Outlet
Power Cord
Location
(Gas Models)
Leveling
Feet
Control
panel
Reversible
door
Front-Mount Lint
Filter
Drying Rack
NOTE
t$POUBDU-($VTUPNFS4FSWJDFBUJO$BOBEBJGBOZBDDFTTPSJFTBSFNJTTJOH
t'PSZPVSTBGFUZBOEGPSFYUFOEFEQSPEVDUMJGFVTFPOMZBVUIPSJ[FEDPNQPOFOUT5IFNBOVGBDUVSFSJTOPUSFTQPOTJCMFGPSQSPEVDU
malfunction or accidents caused by the use of separately purchased unauthorized components or parts.
t5IFJNBHFTJOUIJTHVJEFNBZCFEJGGFSFOUGSPNUIFBDUVBMDPNQPOFOUTBOEBDDFTTPSJFTBOEBSFTVCKFDUUPDIBOHFCZUIFNBOVGBDUVSFS
without prior notice for product improvement purposes.
USB, Wi-Fi for Smart Functions.
Wi-Fi DongleUSB Memory

10 PARTS AND FEATURES
LCD SCREEN INTRODUCTION
HOME/CYCLE SCREEN(S)
The full color LCD touch screen controls are operated by
touching the icons or various areas of the screen as described
in this Owner’s Manual. Touching the icons or buttons changes
the displayed information or navigates among the different
screens. In some cases, special popup screens will be displayed
to confirm your choices or to give you certain information
about the operation or function. Operating guides and other
information are also available on the GUIDE screen. The HOME
screen will dim after four minutes of inactivity. Touch the screen
to brighten the screen, view the display, make additional
changes or operate the dryer. If no icons are touched after the
screen is reactivated, or if the screen remains dimmed for one
minute when a cycle is not running, the control will shut off and
all settings will be lost.
A
D
B
F
C
E
108&3ŷ0/0''Ÿ#6550/
Touch to turn the dryer ON or OFF. Touching the
POWER button during a cycle will cancel that cycle and
any dry settings will be lost. The lid will unlock after a
brief pause.
A.&/6015*0/#6550/4
These buttons will take you to special feature and
settings screens.
D
$:$-&4
The CYCLE screens display cycle names and icons; the
default cycle is Cotton/Normal. Touch the left or right
arrows to scroll through the cycle screens. There are four
screens that will display up to six cycles at a time. Saved
custom cycles will display on the Custom Cycle screen.
The opening screen can be changed from the standard
cycles to the Custom Cycles screen using the Default Cycle
button in the setup screen.
B48*1
You can swipe the screen to navigate though the cycle
screens.
E
45"351"64ᦖ/
Touch this button to start the selected cycle. If the dryer
is running, use this button to pause the cycle without
losing the current settings. Cotton/Normal is the default
cycle. Touching the Start/Pause button without selecting
a cycle will cause this cycle to run immediately.
C45"564*$0/4
Displays the status of various systems and features.
F

11
ENGLISH
CYCLE INFORMATION SCREENS
Selecting a cycle will display the cycle information screen. The
cycle information screen allows you to view or modify the cycle
settings and options of the selected
cycle either before or while paused during the cycle.
4&-&$5&%$:$-&
Displays the icon and name of the selected cycle.
A
#"$,#6550/
Touch this button to return to the previous screen.
D
&455*.&3&."*/*/(
Displays the estimated time remaining in the cycle. This
time will change if settings are modified or if options are
added
B
$:$-&4&55*/(4
Use the arrow keys to adjust the default Dry Level,
Temperature and Dry Time of the cycle. The bar
to the left of each indicator shows the number of
adjustments available.
E
4"7&$:$-&
After modifying a cycle setting, you have the option of
saving it as a custom cycle and adding it to the cycle
screens.
C
$:$-&015*0/4
Add available options to the cycle. Not all options are
available with every cycle. The options that are not
available will be dimmed.
F
"%%*5*0/"-*/'03."5*0/
This area displays extra information for certain cycles
and options. Dry time is shown for timed cycles, and
the number of garments setting is shown for steam
cycles and options. The plus (+) and minus (-) buttons
are used for adjusting the settings. Refer to the steam
or timed dry sections of the manual for allowable
settings.
G
D
A
B
G
E
F
C
PARTS AND FEATURES

12
INSTALLATION INSTRUCTIONS
Preview installation order
Checking and choosing
the proper location
Leveling the dryer
Connecting Electric Dryers
(Electric Dryer Type)
Venting the Dryer
Plugging in the power
cord and grounding
Connecting Gas Dryers
(Gas Dryer Type)
Duct check test
(Refer to page 27.)
INSTALLATION INSTRUCTIONS
120V 240V
Test run

13
ENGLISH
INSTALLATION INSTRUCTIONS
Installation location requirements
WWARNING
3FBEBMMJOTUBMMBUJPOJOTUSVDUJPOTDPNQMFUFMZCFGPSFJOTUBMMJOHBOEPQFSBUJOHZPVSESZFSIt is important that you review this entire
manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust
requirements are provided on the following pages.
%POPUPQFSBUFZPVSESZFSBUUFNQFSBUVSFTCFMPX¡'¡$"UMPXFSUFNQFSBUVSFTUIFESZFSNJHIUOPUTIVUPGGBUUIFFOEPGBOBVUPNBUJD
cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be exposed to water and/or
weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or
sleeping quarters. Contact your local building inspector.
Clearances
INSTALLATION SPACING FOR RECESSED AREA OR CLOSET INSTALLATION
5IFGPMMPXJOHTQBDJOHEJNFOTJPOTBSFSFDPNNFOEFEGPSUIJTESZFS5IJTESZFSIBTCFFOUFTUFEGPSTQBDJOHPGJODIFTDNDMFBSBODFPO
the sides and rear. Recommended spacing should be considered for the following reasons:
t"MPDBUJPOUIBUBMMPXTGPSQSPQFSFYIBVTUJOTUBMMBUJPO"HBTESZFS
must be exhausted to the outdoors. See 7FOUJOH3FRVJSFNFOUT.
t"HSPVOEFEFMFDUSJDBMPVUMFUMPDBUFEXJUIJOGUDNPGFJUIFS
side of the dryer. See &MFDUSJDBM3FRVJSFNFOUT.
t"TUVSEZGMPPSUPTVQQPSUUIFUPUBMESZFSXFJHIUPGMCT
kg). The combined weight of a companion appliance should also
be considered.
tNo other fuel-burning appliance can be installed in the same
closet as a dryer.
t"EEJUJPOBMTQBDJOHTIPVMECFDPOTJEFSFEGPSFBTFPGJOTUBMMBUJPO
and servicing.
t"EEJUJPOBMDMFBSBODFTNJHIUCFSFRVJSFEGPSXBMMEPPSBOEGMPPS
moldings.
t"EEJUJPOBMTQBDJOHTIPVMECFDPOTJEFSFEPOBMMTJEFTPGUIFESZFS
to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
t$PNQBOJPOBQQMJBODFTQBDJOHTIPVMEBMTPCFDPOTJEFSFE
Closet Door Vent
Requirements
21 1/4"
(54 cm)
28 15/16"
(73.4 cm) 4"
(10 cm)
1"
(2.5 cm)
1"
(2.5 cm)
27"
(68.6 cm)
4"
(10 cm)
50 1/4"
(127.5 cm)
NOTE
There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of vibration from one to the
other. Too much vibration, it could cause them to make noise or touch each other causing paint damage and making even more noise.
NOTE
t"MFWFMGMPPSXJUIBNBYJNVNTMPQFPGJODIDNVOEFSFOUJSFESZFS*GTMPQFJTHSFBUFSUIBOJODIDNJOTUBMMUIF&YUFOEFE
Dryer Feet Kit. Clothes may not tumble properly, and automatic sensor cycles may not operate correctly if dryer is not level.
t'PSBHBSBHFJOTUBMMBUJPOZPVXJMMOFFEUPQMBDFUIFESZFSBUMFBTUJODIFTDNBCPWFUIFGMPPS*GVTJOHBQFEFTUBMZPVXJMMOFFE
JODIFTDNUPUIFCPUUPNPGUIFESZFS

14 INSTALLATION INSTRUCTIONS
Clearance (Cont.)
RECOMMENDED INSTALLATION SPACING FOR CABINET INSTALLATION
tFor cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required.
*Required spacing
**For side or bottom venting,
JODIFTDNTQBDJOHJTBMMPXFE
29"
(73.7 cm)
7"* (17.8 cm)
5"**
(12.7 cm)
1"**
(2.5 cm)
7"* (17.8 cm)
1"
(2.5 cm)
1"
(2.5 cm)
27"
(68.6 cm)
Leveling the dryer
WWARNING
t5PSFEVDFUIFSJTLPGJOKVSZUPQFSTPOTBEIFSFUPBMMJOEVTUSZ
recommended safety procedures including the use of
long sleeved gloves and safety glasses. Failure to follow this
warning can cause serious injury or death.
t5IFBQQMJBODFTBSFIFBWZ5XPPSNPSFQFPQMFBSFSFRVJSFE
when installing the dryer. Failure to follow this warning can
cause serious injury or death.
To ensure that the dryer provides optimal drying performance,
it must be level. To minimize vibration, noise, and unwanted
movement, the floor must be a perfectly level, solid surface.
1PTJUJPOUIFESZFSJOUIFGJOBMMPDBUJPO1MBDFBMFWFMBDSPTTUIF
top of the dryer.
t"MMGPVSMFWFMJOHGFFUNVTUSFTUTPMJEMZPOUIFGMPPS(FOUMZQVTI
on the top corners of the dryer to make sure that the dryer does
not rock from corner to corner.
If you are installing the dryer on the optional pedestal, you must
use the leveling feet on the pedestal to level the dryer. The dryer
leveling feet should be fully retracted.
6TFBOBEKVTUBCMFXSFODIUPUVSOUIFMFWFMJOHGFFU5VSO
clockwise to raise the dryer or counterclockwise to lower it.
Raise or lower the leveling feet until dryer is level from side to
side and front to back.
.BLFTVSFUIBUBMMMFWFMJOHGFFUBSFJOGJSNDPOUBDUXJUIUIFGMPPS
Level
Leveling Feet
NOTE
Adjust the leveling feet only as far as necessary to level the
dryer. Extending the leveling feet more than necessary can
cause the dryer to vibrate.

15
ENGLISH
INSTALLATION INSTRUCTIONS
WWARNING
t
To avoid damage to the dryer or the door, support the door with a stool
or box that fits under the door, or have an assistant support the weight of
the door.
t
Avoid dropping the door to avoid damage to the door or the floor.
THE DRYER DOOR IS VERY LARGE AND HEAVY. Failure to follow
the instructions below can result in damage to the dryer,
property damage or injury to persons.
0QFOUIFEPPSBOESFNPWFUIFUXPQMBTUJDIPMFDBQTPOUIF
catch side by gently prying up with a flat blade screwdriver.
4BWFUIFTFGPSTUFQ
8IJMFTVQQPSUJOHUIFEPPSSFNPWFUIFTDSFXTUXPGSPN
each hinge. Set the door aside face down on a protected
surface to prevent damage to the door or the work surface.
8JUIUIFEPPSPOBQSPUFDUFETVSGBDFSFNPWFUIFTDSFXT
on each side of the door and lift off the inner door frame
using a flat blade screwdriver. Remove the latch hook and
blank and move them to the opposite side.
Reversing the door
3FNPWFUIFTDSFXTTFDVSJOHUIFIJOHFTUPUIFEPPSGSBNF
Remove the two plastic cover caps. Reinstall the hinges
and cover caps on the opposite sides from which they were
removed.
8JUIUIFIJOHFTBOEDPWFSDBQTJOUIFOFXMPDBUJPOTSFNPVOU
the inner door frame onto the outer door frame with the screws
SFNPWFEJOTUFQBCPWF
3FJOTUBMMUIFEPPSXJUIUIFTDSFXTGSPNTUFQ
5FTUUIFTXJOHPGUIFEPPSUPNBLFTVSFUIFIJOHFTBOEMBUDIBSF
properly aligned and that the door closes and latches correctly.
Hole cap
Hinge Screw
inner door frame
latch hook
Hinge
assembly
Cover cap
Swing Door

16
Changing the dryer vent location
WWARNING
t6TFBIFBWZNFUBMWFOU
t%POPUVTFQMBTUJDPSUIJOGPJMEVDU
t$MFBOPMEEVDUTCFGPSFJOTUBMMJOHUIJTESZFS
t5PSFEVDFUIFSJTLPGQFSTPOBMJOKVSZBEIFSFUPBMMJOEVTUSZ
recommended safety procedures including the use of long
sleeved gloves and safety glasses.
t'BJMVSFUPGPMMPXBMMPGUIFTBGFUZXBSOJOHTJOUIJTNBOVBMDPVME
result in property damage, Injury to person or death.
Your new dryer is shipped to vent to the rear.
It can also be configured to vent to the bottom or side (right-side
venting is not available on gas models).
An adapter kit, part number &&-#, may be purchased
from your LG retailer. This kit contains the necessary duct
components to change the dryer vent location.
3FNPWFUIFSFBSFYIBVTUEVDUSFUBJOJOHTDSFX1VMMPVUUIF
exhaust duct.
OPTION 1: SIDE VENTING
1SFTTUIFUBCTPOUIFLOPDLPVUBOEDBSFGVMMZSFNPWFUIF
knockout for the desired vent opening (right-side venting is
not available on gas models). Press the adapter duct onto the
blower housing and secure to the base of the dryer as shown.
1SFBTTFNCMFBJODIFTDNFMCPXUPUIFOFYUJODIFT
DNEVDUTFDUJPOBOETFDVSFBMMKPJOUTXJUIEVDUUBQF#F
sure that the male end of the elbow faces AWAY from the dryer.
Insert the elbow/duct assembly through the side opening and
press it onto the adapter duct. Secure in place with duct tape.
#FTVSFUIBUUIFNBMFFOEPGUIFEVDUQSPUSVEFTJODIFT
cm) to connect the remaining ductwork.
Attach cover plate to the back of the dryer with included screw.
OPTION 2: BOTTOM VENTING
1SFTTUIFBEBQUFSEVDUPOUPUIFCMPXFSIPVTJOHBOETFDVSFUP
the base of the dryer as shown.
*OTFSUUIFJODIFTDNFMCPXUISPVHIUIFSFBSPQFOJOH
and press it onto the adapter duct. Be sure that the male end of
the elbow faces down through hole in the bottom of the dryer.
Secure in place with duct tape.
Attach the cover plate to the back of the dryer with included
screw.
Rear
Exhaust Duct
Retaining
Screw
11/2"
(3.8 cm)
Elbow
Cover
Plate
Elbow
Cover
Plate
Knockout
Bracket
Adapter
Duct
Bracket
Adapter
Duct
INSTALLATION INSTRUCTIONS

17
ENGLISH
Venting the dryer
WWARNING
To reduce the risk of fire, electric shock, or personal injury when using this appliance, follow basic precautions, including the following:
t%POPUDSVTIPSDPMMBQTFEVDUXPSL Failure to follow these
instructions can result in fire or death.
t%POPUBMMPXEVDUXPSLUPSFTUPOPSDPOUBDUTIBSQPCKFDUT
Failure to follow these instructions can result in fire or death.
t*GDPOOFDUJOHUPFYJTUJOHEVDUXPSLNBLFTVSFJUJTTVJUBCMF
and clean before installing the dryer. Failure to follow these
instructions can result in fire or death.
tVenting must conform to local building codes. Failure to follow
these instructions can result in fire or death.
t(BTESZFST.645FYIBVTUUPUIFPVUEPPST
Failure to follow these instructions can result in fire or death.
t6TFPOMZJODIDNSJHJEPSGMFYJCMFNFUBMEVDUXPSL
inside the dryer cabinet and for venting outside. Failure to
follow these instructions can result in fire or death.
tTo reduce the risk of fire, combustion, or accumulation of
DPNCVTUJCMFHBTFT%0/05FYIBVTUESZFSBJSJOUPBOFODMPTFE
and unventilated area, such as an attic, wall, ceiling, crawl
space, chimney, gas vent, or concealed space of a building.
Failure to follow these instructions can result in fire or death.
t5PSFEVDFUIFSJTLPGGJSF%0/05FYIBVTUUIFESZFSXJUI
plastic or thin foil ducting.
Failure to follow these instructions can result in fire or death.
t5IFFYIBVTUEVDUNVTUCFJODIFTDNJOEJBNFUFSXJUI
no obstructions. The exhaust duct should be kept as short as
QPTTJCMF.BLFTVSFUPDMFBOBOZPMEEVDUTCFGPSFJOTUBMMJOH
your new dryer. Failure to follow these instructions can result in
fire or death.
t3JHJEPSTFNJSJHJENFUBMEVDUJOHJTSFDPNNFOEFEGPSVTF
CFUXFFOUIFESZFSBOEUIFXBMM*OTQFDJBMJOTUBMMBUJPOT
when it is impossible to make a connection with the above
SFDPNNFOEBUJPOTB6-MJTUFEGMFYJCMFNFUBMUSBOTJUJPOEVDU
may be used between the dryer and wall connection only.
The use of this ducting will affect drying time. Failure to follow
these instructions can result in fire or death.
t%0/05VTFTIFFUNFUBMTDSFXTPSPUIFSGBTUFOFSTXIJDI
extend into the duct that could catch lint and reduce the
efficiency of the exhaust system. Secure all joints with duct
tape. Failure to follow these instructions can result in fire or death.
tTo maximize operating results, please observe the duct length
limitations noted in the chart next page. Failure to follow these
instructions can result in fire or death.
t%VDUXPSLJTOPUQSPWJEFEXJUIUIFESZFS:PVTIPVMEPCUBJO
the necessary ductwork locally. The end cap should have
hinged dampers to prevent backdraft when the dryer is not in
use. Failure to follow these instructions can result in fire or death.
t5IF5PUBMMFOHUIPGGMFYJCMFNFUBMEVDUTIBMMOPUFYDFFEGU
N
t*O$BOBEBUIBUPOMZUIPTFGPJMUZQFGMFYJCMFEVDUTJGBOZ
specifically identified for use with the appliance by the
manufacturer shall be used. In the United States, that only those
foil-type flexible ducts, if any, specifically identified for use with
the appliance by the manufacturer and that comply with the
0VUMJOFGPS$MPUIFT%SZFS5SBOTJUJPO%VDU4VCKFDU"TIBMMCF
used.
INSTALLATION INSTRUCTIONS

18 INSTALLATION INSTRUCTIONS
Venting the dryer (cont.)
ROUTING AND CONNECTING DUCTWORK
Ductwork
8"--$"15:1&
/6.#&30'¡
&-#084
."9*.6.-&/(5)0'
ű*/$)%*".&5&33*(*%
.&5"-%6$5
GUN
GUN
GUN
GUN
GUN
GUN
GUN
GUN
GUN
GUN
4"
(10.2 cm)
Recommended
Use Only for Short
Run Installations
4"
(10.2 cm)
21/2"
(6.35 cm)
*/$033&$57&/5*/(
$033&$57&/5*/(
NOTE
%FEVDUGUNGPSFBDIBEEJUJPOBMFMCPX*UJTOPU
SFDPNNFOEFEUPVTFNPSFUIBOGPVS¡FMCPXT
NOTE
Follow the guidelines below to maximize drying performance
and reduce lint buildup and condensation in the ductwork.
Ductwork and fittings are NOT included and must be
purchased separately.
t6TFJODIDNEJBNFUFSSJHJEPSTFNJSJHJENFUBM
ductwork.
t5IFFYIBVTUEVDUSVOTIPVMECFBTTIPSUBTQPTTJCMF
t6TFBTGFXFMCPXKPJOUTBTQPTTJCMF
t5IFNBMFFOEPGFBDITFDUJPOPGFYIBVTUEVDUNVTUQPJOU
away from the dryer.
t6TFEVDUUBQFPOBMMEVDUKPJOUT
t*OTVMBUFEVDUXPSLUIBUSVOTUISPVHIVOIFBUFEBSFBTJOPSEFS
to reduce condensation and lint buildup on duct surfaces.
t'BJMVSFUPFYIBVTUUIFESZFSDPSSFDUMZXJMMWPJEUIFESZFST
warranty.

19
ENGLISH
Connecting gas dryers
WWARNING
To reduce the risk of fire, electric shock, or personal injury when using this appliance, follow basic precautions, including the following:
Electrical Requirements for Gas Models Only
WWARNING
To reduce the risk of fire, electric shock, or personal injury when using this appliance, follow basic precautions, including the following:
t%POPUVOEFSBOZDJSDVNTUBODFTDVUPSSFNPWFUIFUIJSE
HSPVOEQSPOHGSPNUIFQPXFSDPSEFailure to follow this
warning can result in fire, explosion, or death.
tFor personal safety, this dryer must be properly grounded.
Failure to follow this warning can result in fire, explosion, or death.
t5IFQPXFSDPSEPGUIJTESZFSJTFRVJQQFEXJUIBQSPOH
HSPVOEJOHQMVHXIJDINBUFTXJUIBTUBOEBSEQSPOH
HSPVOEJOHXBMMPVUMFUUPNJOJNJ[FUIFQPTTJCJMJUZPGFMFDUSJD
shock hazard from this appliance. Failure to follow this warning
can result in fire, explosion, or death.
t5IJTESZFSNVTUCFQMVHHFEJOUPB)[7"$HSPVOEFE
outlet protected by a 15-ampere fuse or circuit breaker. Failure
to follow this warning can result in fire, explosion, or death.
tWhere a standard 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced with
a properly grounded 3-prong wall outlet. Failure to follow this
warning can result in fire, explosion, or death.
t(BTTVQQMZSFRVJSFNFOUT
As shipped from the factory, this dryer is configured for use
XJUIOBUVSBMHBT*UDBOCFDPOWFSUFEGPSVTFXJUI-1-JRVFGJFE
1SPQBOFHBT(BTQSFTTVSFNVTUOPUFYDFFEJODIFTPG
water column.
t"RVBMJGJFETFSWJDFPSHBTDPNQBOZUFDIOJDJBONVTUDPOOFDU
the dryer to the gas service.
Failure to do so can result in fire, explosion, or death.
t*TPMBUFUIFESZFSGSPNUIFHBTTVQQMZTZTUFNCZDMPTJOHJUT
individual manual shutoff valve during any pressure testing
of the gas supply. Failure to do so can result in fire, explosion, or
death.
t4VQQMZMJOFSFRVJSFNFOUT
Your laundry room must have a rigid gas supply line to your
ESZFS*OUIF6OJUFE4UBUFTBOJOEJWJEVBMNBOVBMTIVUPGGWBMWF
.645CFJOTUBMMFEXJUIJOBUMFBTUGUNPGUIFESZFSJO
BDDPSEBODFXJUIUIF/BUJPOBM'VFM(BT$PEF"/4*;PS
$BOBEJBOHBTJOTUBMMBUJPODPEF$4"#"1cľJODI/15
pipe plug must be installed. Failure to do so can result in fire,
explosion, or death
t*GVTJOHBSJHJEQJQFUIFSJHJEQJQFTIPVMECFJODI*14
*GBDDFQUBCMFVOEFSMPDBMDPEFTBOEPSEJOBODFTBOEXIFO
acceptable to your gas supplier, 3⁄8 - inch approved tubing
NBZCFVTFEXIFSFMFOHUITBSFMFTTUIBOGUN-BSHFS
UVCJOHTIPVMECFVTFEGPSMFOHUITJOFYDFTTPGGUN
Failure to do so can result in fire, explosion, or death.
tConnect the dryer to the type of gas shown on the nameplate.
Failure to do so can result in fire, explosion, or death.
tTo prevent contamination of the gas valve, purge the gas
supply of air and sediment before connecting the gas supply
to the dryer. Before tightening the connection between the
gas supply and the dryer, purge remaining air until the odor
of gas is detected. Failure to do so can result in fire, explosion, or
death.
t%0/05VTFBOPQFOGMBNFUPJOTQFDUGPSHBTMFBLT6TFB
noncorrosive leak-detection fluid. Failure to do so can result in
fire, explosion, or death.
t6TFPOMZBOFX"("PS$4"DFSUJGJFEHBTTVQQMZMJOFXJUI
flexible stainless steel connectors. Failure to do so can result in
fire, explosion, or death.
tSecurely tighten all gas connections. Failure to do so can result
in fire, explosion, or death.
t%0/05BUUFNQUBOZEJTBTTFNCMZPGUIFESZFSBOZ
EJTBTTFNCMZSFRVJSFTUIFBUUFOUJPOBOEUPPMTPGBOBVUIPSJ[FE
BOERVBMJGJFETFSWJDFQFSTPOPSDPNQBOZ Failure to do so can
result in fire, explosion, or death.
t6TFBQJQFKPJOUDPNQPVOEUIBUJTJOTPMVCMFJO-JRVFGJFE
1FUSPMFVN-1HBTPOBMMQJQFUISFBETFailure to do so can
result in fire, explosion, or death.
INSTALLATION INSTRUCTIONS

20
Connecting gas dryers (cont.)
WWARNING
To reduce the risk of fire, electric shock, or personal injury when
using this appliance, follow basic precautions, including the
following:
t*OTUBMMBUJPOBOETFSWJDFNVTUCFQFSGPSNFECZBRVBMJGJFE
installer, service agency, or the gas supplier. Failure to do so
can result in fire, explosion, or death.
t6TFPOMZBOFXTUBJOMFTTTUFFMGMFYJCMFDPOOFDUPSBOEBOFX
"("DFSUJGJFEDPOOFDUPS Failure to do so can result in fire,
explosion, or death.
t"HBTTIVUPGGWBMWFNVTUCFJOTUBMMFEXJUIJOGUNPG
the dryer. Failure to do so can result in fire, explosion, or death.
t5IFESZFSJTDPOGJHVSFEGPS/BUVSBM(BTXIFOTIJQQFEGSPN
UIFGBDUPSZ.BLFTVSFUIBUUIFESZFSJTFRVJQQFEXJUIUIF
DPSSFDUCVSOFSPSJGJDFGPSUIFUZQFPGHBTCFJOHVTFE/BUVSBM
(BTPS-JRVFGJFE1FUSPMFVN Failure to do so can result in fire,
explosion, or death.
t*GOFDFTTBSZUIFDPSSFDUPSJGJDFGPSUIF-1PSJGJDFLJUPSEFS
QBSUOVNCFS&&-%TIPVMECFJOTUBMMFECZB
RVBMJGJFEUFDIOJDJBOBOEUIFDIBOHFTIPVMECFOPUFEPOUIF
dryer. Failure to do so can result in fire, explosion, or death.
tAll connections must be in accordance with local codes and
regulations. Failure to do so can result in fire, explosion, or
death.
t(BTESZFST.645FYIBVTUUPUIFPVUEPPST Failure to do so can
result in fire, explosion, or death.
Connecting the Gas Supply
.BLFTVSFUIBUUIFHBTTVQQMZUPUIFMBVOESZSPPNJTUVSOFE
OFF. Confirm that the type of gas available in your laundry room
is appropriate for the dryer. The dryer is prepared for Natural
Gas with a ⁄8 - inch NPT gas connection.
3FNPWFUIFTIJQQJOHDBQGSPNUIFHBTDPOOFDUJPOBUUIFCBDL
of the dryer. Be careful not to damage the threads of the gas
connector when removing the shipping cap.
$POOFDUUIFESZFSUPZPVSMBVOESZSPPNTHBTTVQQMZVTJOHB
new flexible stainless steel connector with a ⁄8 - inch NPT fitting.
4FDVSFMZUJHIUFOBMMDPOOFDUJPOTCFUXFFOUIFESZFSBOEZPVS
laundry room’s gas supply. Turn on your laundry room’s gas
supply and check all pipe connections (both internal and
external) for gas leaks with a noncorrosive leak-detection fluid.
Electrical Connection
High-Altitude Installations
The BTU rating of this dryer is AGA-certified for elevations below
GFFU
*GZPVSHBTESZFSJTCFJOHJOTUBMMFEBUBOFMFWBUJPOBCPWF
feet, it must be derated by a qualified technician or gas supplier.
Plug dryer into a 7"$
Hz HSPVOEFEQSPOHPVUMFU
w/15(BT
Connection Gas Supply
Shutoff Valve
w/151JQF
Plug
AGA/CSA-Certified
Stainless Steel Flexible
Connector
INSTALLATION INSTRUCTIONS
Other manuals for SteamDryer DLEX6001V
1
This manual suits for next models
3
Table of contents
Languages:
Other LG Dryer manuals

LG
LG DLE2516W User manual

LG
LG DLGX9501W User manual

LG
LG RC8066 Series User manual

LG
LG DLGX8101 Series User manual

LG
LG RC8066 Series User manual

LG
LG DLEX4200 Series User manual

LG
LG Steam Dryer DLEX2801W Instruction Manual

LG
LG DF22RV2S User manual

LG
LG SteamDryer DLEX5101 User manual

LG
LG DLE6100W User manual