Service Bulletin
Electric Range
Bulletin Number: 0ETO20110061
*3) Solution:
3/3
*4) SVC Bulletin History:
Prior Bulletins: Bulletin number: Date: Content: M/S:
1.
c. Verify the vent trim is installed properly:
- Vent trim: Location No 5527, P/no MJZ41753801
The vent trim should be properly assembled on the front bottom of the oven. In addition,
check the angle between the vent trim and the front bottom of oven (the angle should be
50˚). The angle can be checked by measuring distance between the vent trim and the
bottom. If the distance is shorter than 0.31inch(8mm) or there is no vent trim installed,
the temperature at the electric components (such as thermostat) will overheat during
operation.
Metal trim
Angle:
50˚
Distance:
0.31inch(8mm)
*Thermostat
Description Loc/No. P/No Location Remark
Thermostat 5116 6930W1A003X Upper/Single
Cavity_Up LWD3081ST,LWD3010ST,LSWD305ST
LWS3081ST,LWS3010ST,LSWS305ST
Thermostat 5117 EBG51439301 Upper/Single
Cavity_Lo LWD3081ST,LWD3010ST,LSWD305ST
LWS3081ST,LWS3010ST,LSWS305ST
Thermostat 5118 6930W1A003D Lower Cavity_Lo LWD3081ST,LWD3010ST,LSWD305ST
Thermostat 5119 EBG51439302 Lower Cavity_Up LWD3081ST,LWD3010ST,LSWD305ST