©Copyright 2011 Liberty Pumps Inc. All rights reserved
IMPORTANT:
Prior to installation, record Model, Serial Number, and
Code Number from pump nameplate for future reference.
MODEL ________________________
SERIAL ______________________
CODE ______________________
INSTALLATION
DATE _______________________
CSP-237 1/3HP 115V 60Hz
CSP-257 1/3HP 115V 60Hz
CSP-457 1/2HP 115V 60Hz
7000 Apple Tree Avenue
Bergen, NY 14416
Phone: (800) 543-2550
Fax: (585) 494-1839
www.libertypumps.com
Contents
1.) General Information and Safety
Guidelines
2.) Installation
3.) Maintenance and Troubleshooting
Installation Manual 4353000C
Model CSP-237, CSP-257, and CSP-457 Crawl Space Pump
©Copyright 2011 Liberty Pumps Inc. All rights reserved -2- 2
Before installation, read the following instructions carefully. Each Liberty pump is individually factory tested to insure proper
performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service.
Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.
The electrical connections and wiring for a pump installation should only be made by qualified personnel.
This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
Do not bypass grounding wires or remove ground prong from attachment plugs.
Do not use an extension cord.
This pump requires a separate, properly fused and grounded branch circuit. Make sure the power source is properly sized for the
voltage and amperage requirements of the pump, as noted on the nameplate.
The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor level to minimize
possible hazards from flood conditions.
The installation must be in accordance with the National Electric Code and Plumbing Codes as well as all applicable local codes
and ordinances.
Fig. 1 –Typical Residential Installation
This is a recommended installation only.
1. General Information and Safety Guidelines
2. Installation
Figure 1
©Copyright 2011 Liberty Pumps Inc. All rights reserved -3- 3
Application: The CSP-237, CSP-257, and CSP-457 crawl space pumps are designed for use in a crawl space or where pooling water
is occurring. Allowing the water in the pump or discharge line to freeze may cause damage to the pump. In colder regions, the pump
should only be installed indoors or deep enough to be below the frost line.
A. BACKFILL: For in ground installation a hole should excavated as small as possible, leaving at least 8” of diametrical clearance.
Course gravel is recommended for backfill.
B. INLET: The CSP-237, CSP-257, and CSP-457 include a perforated basin for gathering water. Additional inlets may be added with
a hole saw for allowing drain lines or weep tiles.
C. DISCHARGE: When attaching the discharge, place the pump in the basin being careful to keep float from any obstruction or from
hitting the tank wall. The CSP-237, CSP-257, and CSP-457 include a DHK-24 discharge hose kit. A 1-1/2” X 1-1/4” hose adapter
will thread into the pump discharge. The 24’ flexible hose will fit over the barbed fitting of the adapter and should be tightened
down with a hose clamp. The hose will fit through the grommet in the basin cover and can be cut to the required length. Exit the
discharge of water in an area that will drain away from the building and foundation.
D. CHECK VALVE: The CSP-237, CSP-257, and CSP-457 include a threaded check valve for use with the discharge hose. If the
pump is short cycling, then a check valve may be required. This would prevent water from draining back through the discharge
hose into the basin. When using a check valve, the discharge line must be protected from freezing by running the discharge deep
enough below ground level to be beneath the frost line. See figure 1.
E. POWER CORD: The pump power cord is equipped with a grounding conductor and grounding-type 3-prong plug. It should be
connected to a separately fused, grounded, 3-wire grounding-type receptacle of 15-amp capacity with the proper 115V. Make sure
all electrical wiring and connections are in accordance with the National Electric Code and all applicable local codes.
Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.
DO NOT remove the plug or ground prong.
DO NOT use an extension cord.
©Copyright 2011 Liberty Pumps Inc. All rights reserved -4- 4
Each unit is individually factory tested to ensure proper adjustment and operation. If the unit fails to operate properly, carefully re-read
the instructions to see that they have been followed correctly. Routine maintenance is not required on the pump itself, but associated
connections may require occasional attention. The check valve on the discharge should also be checked for freedom of operation at
the same time.
NOTE: Liberty Pumps, Inc. assumes no responsibility for damage or injury due to disassembly beyond float removal in the field.
Disassembly, other than at Liberty Pumps or its authorized service centers, automatically voids warranty.
3 Year Limited Warranty
Liberty Pumps, Inc. warrants that pumps of its manufacture are free from all factory defects in material and workmanship for a period of
3 years from the date of purchase. The date of purchase shall be determined by a dated sales receipt noting the model and serial
number of the pump. The dated sales receipt must accompany the returned pump if the date of return is more than 3 years from the
"CODE" (date of manufacture) number noted on the pump nameplate. The manufacturer's obligation under this Warranty shall be
limited to the repair or replacement of any parts found by the manufacturer to be defective, provided the part or assembly is returned
freight prepaid to the manufacturer or its authorized service center, and provided that none of the following warranty-voiding
characteristics are evident. The manufacturer shall not be liable under this Warranty if the product has not been properly installed; if it
has been disassembled, modified, abused or tampered with; if the electrical cord has been cut, damaged or spliced; if the pump
discharge has been reduced in size; if the pump has been used in water temperatures above the advertised rating, or water containing
sand, lime, cement, gravel or other abrasives; if the product has been used to pump chemicals or hydrocarbons; if a non-submersible
motor has been subjected to excessive moisture; or if the label bearing the serial, model and code number has been removed. Liberty
Pumps, Inc. shall not be liable for any loss, damage or expenses resulting from installation or use of its products, or for consequential
damages, including costs of removal, reinstallation or transportation. There is no other express warranty. All implied warranties,
including those of merchantability and fitness for a particular purpose, are limited to two years from the date of purchase. This
Warranty contains the exclusive remedy of the purchaser, and, where permitted, liability for consequential or incidental damages under
any and all warranties are excluded.
Problem
Cause
Correction
Pump will not turn
on
Blown fuse or other interruption of
power; improper voltage.
Check that the unit is securely plugged in.
Have an electrician check all wiring for proper
connections and adequate capacity.
Defective switch or build-up on tank
wall restricting free movement of
float switch.
Check that float is free to move. If build-up
restricts float, clean and reinstall. If defective,
replace switch.
Pump runs or hums
but does not pump.
Discharge is blocked or restricted.
Check the discharge line for blockage,
including ice if the line passes through or into
cold areas.
Check valve is stuck closed or
installed wrong.
Remove and examine for freedom of
operation and proper installation.
Total lift height has been reached
(see Fig. 2)
Try routing pipe to a lower level. If not
possible, another pumping station may be
required at a level of roughly half the total lift.
Pump impeller is jammed.
*Disassemble the receiver and bottom base
of pump. Remove foreign material.
Reassemble.
Defective switch.
Check that float is free to move. If build-up
restricts float, clean and reinstall. If defective,
replace switch.
Pump does not turn
off
Defective switch or build-up on tank
wall restricting free movement of
float switch.
Check that float is free to move. If build-up
restricts float, clean and reinstall. If defective,
replace switch.
Pump operates
noisily.
Foreign objects in impeller cavity.
*Disassemble the receiver and bottom base
of pump. Remove foreign material.
Reassemble.
Broken impeller
Consult the factory for information regarding
the replacement of impeller.
3. Maintenance and Troubleshooting

This manual suits for next models

2

Other Liberty Pumps Water Pump manuals

Liberty Pumps 441 User manual

Liberty Pumps

Liberty Pumps 441 User manual

Liberty Pumps HT450 Series User manual

Liberty Pumps

Liberty Pumps HT450 Series User manual

Liberty Pumps 250 User manual

Liberty Pumps

Liberty Pumps 250 User manual

Liberty Pumps 230 Series User manual

Liberty Pumps

Liberty Pumps 230 Series User manual

Liberty Pumps CSP Series User manual

Liberty Pumps

Liberty Pumps CSP Series User manual

Liberty Pumps SumpJet SJ10 User manual

Liberty Pumps

Liberty Pumps SumpJet SJ10 User manual

Liberty Pumps Pro370 Series User manual

Liberty Pumps

Liberty Pumps Pro370 Series User manual

Liberty Pumps Omnivore XLSG200 Series User manual

Liberty Pumps

Liberty Pumps Omnivore XLSG200 Series User manual

Liberty Pumps Pro380 Series User manual

Liberty Pumps

Liberty Pumps Pro380 Series User manual

Liberty Pumps ProVore PDC Series User manual

Liberty Pumps

Liberty Pumps ProVore PDC Series User manual

Liberty Pumps Pro370 Series User manual

Liberty Pumps

Liberty Pumps Pro370 Series User manual

Liberty Pumps PRG102M-3E User manual

Liberty Pumps

Liberty Pumps PRG102M-3E User manual

Liberty Pumps 406 User manual

Liberty Pumps

Liberty Pumps 406 User manual

Liberty Pumps ProVore PDC-115 User manual

Liberty Pumps

Liberty Pumps ProVore PDC-115 User manual

Liberty Pumps Omnivore RE Series User manual

Liberty Pumps

Liberty Pumps Omnivore RE Series User manual

Liberty Pumps Builder S30 Series User manual

Liberty Pumps

Liberty Pumps Builder S30 Series User manual

Liberty Pumps SPAC-237 User manual

Liberty Pumps

Liberty Pumps SPAC-237 User manual

Liberty Pumps PC Series User manual

Liberty Pumps

Liberty Pumps PC Series User manual

Liberty Pumps EPS User manual

Liberty Pumps

Liberty Pumps EPS User manual

Liberty Pumps HT450 Series User manual

Liberty Pumps

Liberty Pumps HT450 Series User manual

Liberty Pumps LCU-N Series User manual

Liberty Pumps

Liberty Pumps LCU-N Series User manual

Liberty Pumps 331 User manual

Liberty Pumps

Liberty Pumps 331 User manual

Liberty Pumps 404 User manual

Liberty Pumps

Liberty Pumps 404 User manual

Liberty Pumps Sump Pump Combo PC237-441 User manual

Liberty Pumps

Liberty Pumps Sump Pump Combo PC237-441 User manual

Popular Water Pump manuals by other brands

Watershed Innovations HYDRAPUMP SMART FLEX Instructional manual

Watershed Innovations

Watershed Innovations HYDRAPUMP SMART FLEX Instructional manual

Graco Modu-Flo AL-5M instructions

Graco

Graco Modu-Flo AL-5M instructions

Messner MultiSystem MPF 3000 operating instructions

Messner

Messner MultiSystem MPF 3000 operating instructions

Xylem Bell & Gossett WEHT0311M Installation, operation and maintenance instructions

Xylem

Xylem Bell & Gossett WEHT0311M Installation, operation and maintenance instructions

WilTec 50739 Operation manual

WilTec

WilTec 50739 Operation manual

Franklin Electric Little Giant 555702 HRK-360S instruction sheet

Franklin Electric

Franklin Electric Little Giant 555702 HRK-360S instruction sheet

Ingersoll-Rand PD02P Series Operator's manual

Ingersoll-Rand

Ingersoll-Rand PD02P Series Operator's manual

VS ZJ Series Operating	 instruction

VS

VS ZJ Series Operating instruction

Flotec FPZS50RP owner's manual

Flotec

Flotec FPZS50RP owner's manual

SKF Lincoln FlowMaster II User and maintenance instructions

SKF

SKF Lincoln FlowMaster II User and maintenance instructions

Xylem Lowara LSB Series Installation, operation and maintenance instructions

Xylem

Xylem Lowara LSB Series Installation, operation and maintenance instructions

Water Duro Pumps DCJ500 Operating & installation instructions

Water

Water Duro Pumps DCJ500 Operating & installation instructions

Action P490 Operating instructions & parts manual

Action

Action P490 Operating instructions & parts manual

Flo King Permacore Reusable Carbon Bag Disassembly. & Cleaning Instructions

Flo King

Flo King Permacore Reusable Carbon Bag Disassembly. & Cleaning Instructions

ARO ARO PD15P-X Operator's manual

ARO

ARO ARO PD15P-X Operator's manual

Pumptec 112V Series Operating instructions and parts manual

Pumptec

Pumptec 112V Series Operating instructions and parts manual

Virax 262070 user manual

Virax

Virax 262070 user manual

Neptun NPHW 5500 operating instructions

Neptun

Neptun NPHW 5500 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.