-8-
C. SMOKE ALARM SETUP TEST
For your safety, the Setup Test with your smoke alarm
is a necessary part of setting up your Lifetone HL™.
This important test will determine if your existing smoke alarms are of the
T3 type that is compatible with your Lifetone HL™.
2. Press and hold the test button on the smoke alarm until the
Lifetone HL™ alarm sounds. At least two smoke alarm T3 cycles
(groups of 3 beeps) are required. You may need as many as six
in a row if there is excessive background noise or your alarms are
distant.
When power was first applied (previous page), your Lifetone HL™ flashed "TEST" on the
screen. You pressed the Test/Silence button and “TEST” stopped flashing for a short time.
Now it is flashing TEST the second time. You are ready to start the setup test. You have
10 minutes to present a recognizable T3 signal to your HL™.
ALWAYS ASK FOR ASSISTANCE WHENEVER YOU ARE UNABLE TO PROPERLY
AND SAFELY ACTIVATE YOUR EXISTING SMOKE ALARMS DURING THE SMOKE
ALARM SETUP TEST. IF YOU HAVE A MONITORED SMOKE OR FIRE ALARM
SYSTEM, CONTACT YOUR SERVICE AND TELL THEM YOU ARE TESTING YOUR
SYSTEM. WHEN YOU ARE FINISHED, CALL THEM AGAIN TO TELL THEM YOUR
TESTS ARE COMPLETED.
3. If the test is successful, your HL™ will sound its alarm, the bed
shaker will vibrate, and "FIRE" will flash on the screen. Press the
red TEST/SILENCE button on the back to silence the alarm.
After a successful test, "12 hr" will flash on the screen. See the
note below, and then go to the next page and set the clock.
NOTE. If you have a First Alert talking alarm model SCO7 or
SCO500 made before October of 2011 (see the back of the alarm
for the date), you must also do a functional test as described in
section G, TESTING YOUR LIFETONE HL™ to ensure that the
emergency signal from that alarm is UL 217-compliant and compatible.
________________________________________________
___________________________________
___________________________________
1. Locate the most distant smoke alarm you want detected. If you
have an interconnected alarm system, use the nearest smoke alarm.
It is recommended you use an alarm that is easy to reach and
activate, avoiding alarms on high ceilings.
___________________________________
If at the end of 10 minutes the test was not
successful, the Lifetone HLAC150 will flash
all segments on the screen, shake the bed
shaker if attached, and sound a chirp every
5 seconds. Unplug the HL™ and take the batteries out. You may try the test again from
step 1 above, but you may have a non-compliant or older non-T3 smoke alarm.
Please refer to section H, UNSUCCESSFUL SMOKE ALARM SETUP TEST.
4. If the set-up test was not successful, use a nearer smoke alarm and try again.
________________________________________________
WARNING! DONOT COVER
ACPOWER
WARNING! DO NOT COVER
ACPO WER
VIBRATING LOW-PITCHED
T3 ALARM
WARNING! DO NOTCOVER
ACPOWER
FLASHING
FLASHING