Litelink MIDI-2101 Series User manual

WARRANTY
All fiber optic transmission systems, products and accessories
manufactured by Liteway, Inc. and it’s subsidiaries are fully tested
prior to shipment and are warranted against defective materials
and workmanship for a period of five full years from the date of the
original shipment. Should a problem occur, a Return Material
Authorization Number (RMA) must be obtained from Liteway Inc.
at (516) 931-2800 and the item returned to Liteway, Inc. 166
Haverford Road, Hicksville, NY 11801, USA, prepaid. Liteway Inc.
will then, at its option repair or replace the defective item.
Liteway, Inc. maximum liability under this warranty is limited to the
cost of the defective item only. No contingent liabilities of any kind
are either assumed or implied.
Any items returned to Liteway, Inc. that have been misused,
abused, damaged, modified, connected or adjusted in any way
contrary to the instructions furnished by Liteway, Inc. or repaired
by unauthorized personnel will not be covered by this warranty.
Any non-warranty repairs required will be quoted at the current
rate for such services.
Important Notices
CAUTION ! AVOID DIRECT EXPOSURE TO BEAM.
All -7,-8, and -9 Models use laser diodes. These solid-state laser diodes
are located in the optical ports of these units. Laser diodes produce
invisible radiation that may be harmful to human eyes. Never look
directly into the optical port of any fiber optic unit designed to operate
with single-mode optical fiber.
NOT FOR LIFE SUPPORT SYSTEMS
Liteway, Inc. does not authorize or warrant any of its products or
accessories for use in critical life support systems or applications of any
kind.
© Copyright 2017 Liteway, Inc. 125480 Rev D
OPERATING INSTRUCTIONS
Fiber Optic MIDI
Transmission System
Models;
MIDI-2101-x Transmitter
MIDI-2201-x Receiver
The MIDI-2101/2201 system consists of
the MIDI-2101 transmitter and MIDI-2201
receiver. This system will transmit all
standard MIDI 1.0 data signals over
beyond the specified 50 foot (15 meter)
limit without signal loss or interference
between the two MIDI units.
Technical Specifications
Bandwidth DC – 1.0 Mb/s (Includes 31.25 Kbaud)
Protocol supported MIDI 1.0 (all formats)
Rise / Fall Time Less than 100 nanoseconds
Bit-error Rate 1 x 10-9 (worse case)
Signal Connectors 5 pin 180° DIN
Input Isolation Optical Isolation 10 KV/us
Output Drive 25mA maximum (5 times MIDI 1.0)
Operating Wavelength 850 (-1), 1300 (-3,-7), 1550 (-9)
Optical Output -15 dBm typical
Optical Loss Budget 0 – 10 dB
Optical Connectors Multimode fiber models (-1, -3) ST/PC,
Single-mode fiber models (-7,-9) FC/PC
Temperature Range -35º to +75ºC
Power Requirements 11-24 VAC/DC @160 mA
Physical Size (mm) 5.0”(127)L x 1.0” (25.4)W x 3.0”(7)D
All specifications measured with 1Km of 62.5u multimode fiber.
All specifications are subject to change without prior notice.
!

Installation Instructions
The diagrams below show the location of the connectors for the MIDI-
2101 and the MIDI-2201. For proper operation, the units should
always be connected as shown.
MIDI-2101 Transmitter Considerations
The MIDI IN connector on this unit should be connected to the
standard MIDI signal to be transmitted over the fiber optic cable via a
standard 5 position 180° DIN connector cable. If a MIDI Thru output
signal is required, it may be obtained from the MIDI OUT connector
on the unit.
MIDI-2201 Receiver Considerations
The MIDI OUT connector on this unit should be connected to any
device that should receive the MIDI signal being transmitted over the
fiber optic cable. A standard 5 position 180° DIN connector cable
should be used
MIDI-2101/2201 Transmitter/Receiver Considerations
When the MIDI-2101 and MIDI 2201 units are connected with fiber
optic cable the result is a one-way transmission system. MIDI signals
applied to the MIDI IN connector of the MIDI-2101 transmitter will
appear at the MIDI OUT connector on the MIDI-2201
Note that you must
connect the Tx port
of one unit to the Rx
port of the other unit
with the appropriate
size fiber optic cable
125480 Rev D
Power Terminal Block Connections
Pin Function
1 Alarm output for use with optional Alarm Sensing Unit
ALM-1000. No other connections should be made to this
terminal.
2 +11 to 24 DC or AC Volts input
3 AC or DC return (Common to Housing)
Be certain to check all connections, settings and voltages before
applying power
Indicator Lights
Indicator Lights when
Pwr Proper power is present.
Alrm There is no valid fiber optic connection between
the units.
Tx, Rx A MIDI data signal is being transmitted or received.
At low data rates these indicators may blink with
data.
Link A valid fiber optic connection exists between the
two MIDI units connected together. If the Link light
is not on MIDI data will not be transmitted
Fiber Optic Cable
Rd
Td
This manual suits for next models
1
Table of contents
Other Litelink Receiver manuals