manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LITEMATRIX
  6. •
  7. Light Fixture
  8. •
  9. LITEMATRIX Line L65AG Series User manual

LITEMATRIX Line L65AG Series User manual

This manual suits for next models

9

Popular Light Fixture manuals by other brands

Veko Magnus manual

Veko

Veko Magnus manual

Cooper Lighting Halo L10538 specification

Cooper Lighting

Cooper Lighting Halo L10538 specification

Emos CLASSIC ZY1431T manual

Emos

Emos CLASSIC ZY1431T manual

Westinghouse Outdoor Lighting Fixture owner's manual

Westinghouse

Westinghouse Outdoor Lighting Fixture owner's manual

Hedler C 12 silent Operation manual

Hedler

Hedler C 12 silent Operation manual

Blizzard Lighting Puck: CSI manual 

Blizzard Lighting

Blizzard Lighting Puck: CSI manual 

Energetic Lighting ELYSL-5004 Series installation instructions

Energetic Lighting

Energetic Lighting ELYSL-5004 Series installation instructions

Lightmaxx Shaft 5R user manual

Lightmaxx

Lightmaxx Shaft 5R user manual

Triarch 31083 Assembly instructions

Triarch

Triarch 31083 Assembly instructions

Philips 32614 Series user manual

Philips

Philips 32614 Series user manual

IKEA TIVED Assembly instructions

IKEA

IKEA TIVED Assembly instructions

Lightolier LP200 specification

Lightolier

Lightolier LP200 specification

Chauvet Professional ROGUE R1 BEAM WASH user manual

Chauvet Professional

Chauvet Professional ROGUE R1 BEAM WASH user manual

Martin MAC 250 Krypton user manual

Martin

Martin MAC 250 Krypton user manual

Cooper Lighting Halo L3232E Specification sheet

Cooper Lighting

Cooper Lighting Halo L3232E Specification sheet

Stageline ODW-2410RGBW instruction manual

Stageline

Stageline ODW-2410RGBW instruction manual

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier Lytespan 83ED17S specification

Lightolier

Lightolier Lytespan 83ED17S specification

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Instruction Line Pendant
LITEMATRIX(HK) CO LIMITED Phone:
852 30501787 LiteMatrix reserves the right to make technical and design
changes without prior notice.
Flat A 8/F No.227 Nathan Road Yau Ma Tei Kowloon Hongkong Fax: 852 30506957
www.litematrixlighting.com E-mail: [email protected] 2017.10 1 / 3
L65AG
L65AG DI
Instruction of installation:
—Read the instructions carefully before installation and commissioning.
—The safety of the device can only be guaranteed on condition that to be respected the following instructions, both stages of installatio
n and use therefore it is highly
recommended to keep them.
—When installing, always observe the national installation and accident prevention regulations.
—Installation and commissioning may only be carried out by authorized specialists.
—The device cannot be in any case modified or forced, any modification might jeopardize the safety system making it dangerous. LiteMatrix declines a
ny responsibility
on modified products
FOR INDOOR USE ONLY!
ATTENTION: For suspension mounting. Luminaire not suitable for being covered with heavy staffs or thermally insulating materials.
Table 1-Parameters
L A H Mass Finish Color of
reflector
mm mm mm kg
LAG-565
565 80-100 Max.
2000
2.6 White/
Black
White/
Silver
LAG-565-DI 2.8
LAG-1125
1125 80-100 Max.
2000
5.0 White/
Black
White/
Silver
LAG-1125-DI 5.2
LAG-1685
1685 80-100 Max.
2000
7.8 White/
Black
White/
Silver
LAG-1685-DI 8.0
LAG-2245
2245 80-100 Max.
2000
10.4 White/
Black
White/
Silver
LAG-2245-DI 10.8
-Lateral air space under EN 60598: The lateral distance between the surface of
the luminaire and any parts of the building must be no less than 50mm.
-Please DO NOT exceed the rated load-bearing of ceilings.
-Recommended mounting and using environment: Ta=25℃.
Instruction Line Pendant
LITEMATRIX(HK) CO LIMITED Phone:
852 30501787 LiteMatrix reserves the right to make technical and design
changes without prior notice.
Flat A 8/F No.227 Nathan Road Yau Ma Tei Kowloon Hongkong Fax: 852 30506957
www.litematrixlighting.com E-mail: [email protected] 2017.10 2 / 3
Installation of live end 7. Install and then fix the junction box
Power Connection of live end Interconnection
1. During the installation, make sure
the power supply is disconnected. Put
on gloves and operate in dry environ-
ment
For DALI versions 1. Remove the end caps
2. Mark the location of suspension
cord according to table 1.
2. Put connecting device into body
Installation of non-live end
1. Suspension cord installation
For On-off/Wireless versions
3. Ceiling cutout.
3. Fix them
Installation of lamp body
1. Fix the suspension cord
4. Power connection.
4. Install the fixing part
2. Adjust the suspension cord to
maintain horizontal
Power Connection of non-live end
Connect via quick coupling
5. Install suspension cord through A
to B
5. Assemble adjacent luminaires and
fix them together.
ATTENTION:
For safety consideration, during the
installation, make sure the power supply
is disconnected.
Avoid any damage to supply cable.
Su
spension cord should not be longer
than supply cable
Single or continuous line available. The
maximum load current should not
exceed 5A.
6. Connect to power supply(Refer to
Power Connection part)
6. Fix the end caps and suspend.
Instruction Line Pendant
LITEMATRIX(HK) CO LIMITED Phone:
852 30501787 LiteMatrix reserves the right to make technical and design
changes without prior notice.
Flat A 8/F No.227 Nathan Road Yau Ma Tei Kowloon Hongkong Fax: 852 30506957
www.litematrixlighting.com E-mail: [email protected] 2017.10 3 / 3
Reflector change
Reflectors are fixed by magnet force
and convenient to be removed or
installed by hand. Black or silver
available.
Cleaning
Always clean carefully using a soft
cloth and a commercially available, ph-
neutral, alcohol-free, non-abrasive
cleaning agent.
Disposal
In accordance with EU Directive
WEEE
(Waste Electrical and Electronic
Equipment), luminaires must not be
disposed of with other household
waste. At the end of their life,
luminaires must be taken to the
appropriate local facility available for
the disposal
or recycling of electronic
products.