Instruction Line Pendant
LITEMATRIX(HK) CO LIMITED Phone:
852 30501787 LiteMatrix reserves the right to make technical and design
changes without prior notice.
Flat A 8/F No.227 Nathan Road Yau Ma Tei Kowloon Hongkong Fax: 852 30506957
Installation of live end 7. Install and then fix the junction box
Power Connection of live end Interconnection
1. During the installation, make sure
the power supply is disconnected. Put
on gloves and operate in dry environ-
ment
For DALI versions 1. Remove the end caps
2. Mark the location of suspension
cord according to table 1.
2. Put connecting device into body
Installation of non-live end
1. Suspension cord installation
For On-off/Wireless versions
3. Ceiling cutout.
3. Fix them
Installation of lamp body
1. Fix the suspension cord
4. Power connection.
4. Install the fixing part
2. Adjust the suspension cord to
maintain horizontal
Power Connection of non-live end
Connect via quick coupling
5. Install suspension cord through A
to B
5. Assemble adjacent luminaires and
fix them together.
ATTENTION:
For safety consideration, during the
installation, make sure the power supply
is disconnected.
Avoid any damage to supply cable.
Su
spension cord should not be longer
than supply cable
Single or continuous line available. The
maximum load current should not
exceed 5A.
6. Connect to power supply(Refer to
Power Connection part)
6. Fix the end caps and suspend.