Living Earth Contour User manual

Contour Pedicure Line
INSTALLATION MANUAL
1-400-00XX • Rev A • X/X/XX
© Living Earth Crafts 2017, All Rights Reserved
*shown with oponal accessories and/or nishes
Contour LX
Contour

© Copyright 2016
Living Earth Cras®
All rights reserved. is document or any
portion thereof may not be reproduced
in any way, including photocopying or
translation to another language without
the prior written permission from Living
Earth Cras.
Living Earth Cras® is a registered trade-
mark of Earthlite Massage Tables, Inc.
Legal Notice
e information provided in this document is intended
for informational purposes only and is subject to change
without notice. e information provided in this docu-
ment should not be construed as a commitment by
Living Earth Cras®.
Living Earth Cras® assumes no responsibility for the
accuracy or suitability of the information contained in
this document. is document may contain technical
inaccuracies or errors. Living Earth Cras® makes no
expressed or implied warranties of any kind concerning
the information contained in this document, including,
but not limited to, the implied warranties of merchant-
ability and tness for purpose.
Living Earth Cras® shall not be liable for incidental or
consequential damages in connection with or arising out
of the product, performance, or use of this document
and the information and material it describes.
Introduction
Congratulaons on your purchase of the Contour pedicure chair. This manual is designed to be
given to the licensed plumbers, electricians, and any other technicians performing the installaon
of your pedicure chairs.
Installer(s): Please review this manual in detail before beginning installaon, and follow all safety
warnings, labels, and instrucons. If you have quesons, please contact Living Earth Cras at
(800) 872-0560 for US customers, or (760) 597-2155 for internaonal customers. We can also be
reached via e-mail at info@livingearthcras.com
Secon 1: Safety Informaon
Safety Symbols/Warnings
Secon 2: Product Overview
Product Diagram
Product Specicaons
Secon 3: Installaon
Installaon Locaon/Spacing
Electrical & Plumbing
Backow Prevenon
Inial Assembly
Electrical Specicaons
Contact Us
2-3
4
5
6-7
8-9
10-11
12-13
14
back cover
Table of Contents

SECTION 1: SAFETY INFORMATION
Safety Symbols ALERT
Indicates a potentially hazardous
situation which could result in
equipment damage and/or injury.
Familiarize yourself with the following Safety &
Warning symbols. They are designed to prevent
damage and injury to you, your clients, and your
new Living Earth Crafts product.
ATTENTION
Consult accompanying documents
CAUTION
Indicates a potentially hazardous
situation which may result in minor or
moderate injury.
DANGER
Indicates an imminently hazardous
situation which will result in serious or
fatal injury - used in extreme conditions.
WARNING
Indicates a potentially hazardous
situation which could result in serious
injury.
Important Information About Safety Instructions
The important safety instructions and warnings in this manual cannot cover all possible problems and conditions
that can occur. Use common sense and caution when installing, operating, or maintaining this appliance.
WARNING - RISK OF ACCIDENTAL INJURY OR DROWNING. DO NOT
USE DRUGS OR ALCOHOL BEFORE OR DURING USE. CHILDREN OR
HANDICAPPED PERSONS SHOULD NOT USE WITHOUT SUPERVISION.
WARNING - RISK OF HYPERTHERMIA AND POSSIBLE DROWNING. WATER
TEMPERATURE IN EXCESS OF 38°C or 100.4°F CAN BE INJURIOUS TO YOUR
HEALTH. CHECK AND ADJUST WATER TEMPERATURE BEFORE USE.
READ AND SAVE THESE INSTRUCTIONS
SECTION 1: SAFETY INFORMATION
INSTALLATION INSTRUCTIONS / GROUNDING INSTRUCTIONS
WARNING - When using electrical products, basic precautions should always
be followed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected
by a ground-fault circuit-interrupter.
2. Grounding is required. The unit should be installed by a quali ed service
representative and grounded.
This product must be grounded. If it should malfunction or break down, grounding provides
a path of least resistance for electric current to reduce the risk of electric shock. This product
is equipped with a cord having an equipment-grounding conductor and grounding plug. The
plug must be plugged into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Improper connection of the equipment-grounding connector can result in a risk of electric shock.
Check with a qualifi ed electrician or serviceman if you are in doubt as to whether the product is
properly grounded. Do not modify the plug provided with the product - if it will not fi t the outlet,
have a proper outlet installed by a qualifi ed electrician.
READ AND SAVE THESE INSTRUCTIONS
23
IMPORTANT SAFETY INSTRUCTIONS - FOR COMMERCIAL USE ONLY
Read all instructions before using the Contour pedicure chair.
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above
the body temperature of 98.6°F or 37°C. The symptoms of hyperthermia include an increase in the internal
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat,
b) Failure to recognize the need to exit the hydromassage bathtub,
c) Unawareness of impending hazard,
d) Fetal damage in pregnant women,
e) Physical inability to exit the hydromassage bathtub, and
f) Unconciousness resulting in the danger of drowning. WARNING - The use of alcohol, drugs, or medication
can greatly increase the risk of fatal hyperthermia.
WARNING - RISK OF ELECTRIC SHOCK - Do not permit electric appliances (such as hair dryers,
lamp, telephone, radio, or television) to be within 5 ft (1.5m) of this unit.
WARNING - RISK OF INJURY - Exercise care when using a foot bath. Use this product for its intended
purpose: a manicure chair and fi ll and drain indoor commercial appliance for foot and ankle hydro massage.
DO NOT use attachments not recommended by manufacturer.
WARNING - MOVABLE PARTS, RISK OF INJURY:
• Keep children away from adjustable seat armrests, tilt back, and seat slide, and footrest.
WARNING - To reduce the risk of burns, fi re, electric shock, or injury to persons:
• Unplug from outlet before putting on or taking off parts.
• Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled
persons. DO NOT leave children alone or allow them to operate the controls. Keep controls out of reach
of children. DO NOT allow children to crawl behind the chair.
• Never use this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or dropped into water. Return the furnishing to a service center for examination
and repair.
• Keep the cord away from heated surfaces.
• Never operate the furnishing with the air openings blocked. Keep the air openings free of lint, hair, etc.
• Never drop or insert any object into any opening.
WARNING
• DO NOT reach for any electrical object that has fallen into the water. Unplug immediately.
• DO NOT drop or insert anything into jet opening.
• DO NOT operate without the complete jet assembly installed or without water fi lled 1 inch above jets.
• DO NOT overfi ll the basin.
• DO NOT stand on or in the basin, or on the foot rest.
• DO NOT leave this appliance unattended when in operation.
• DO NOT use outdoors.
• Keep the electrical cord away from heated surfaces.
• Connect this appliance only to a properly grounded outlet.
• To avoid injury, exercise care when entering or exiting the chair and foot bath.
• Use caution when making positioning adjustments to your chair. Keep all equipment and body parts
away from moving parts while making any adjustments.
• It is important that you clean and disinfect the jets and basin after every use.
• Hydrotherapy should be pleasant and comfortable. Should you or a client experience any pain or
discomfort while using the foot bath, discontinue use immediately and consult a physician.
• You or your clients should consult a physician if diabetic, have poor circulation, if feet or legs are in-
fl amed, have an open wound, or if you have questions about whether you should be using hydro mas-
sage equipment.
• A qualifi ed plumber and electrician are strongly recommended to install your foot bath.
• Make certain that the cord and plug are maintained in good condition and are not allowed to become
damaged while in use. Avoid positioning the cord in the traffi c lane and it is always kept out of the way.
Take this furnishing out of service immediately if the cord or plug becomes damaged in any way.
• Do not attempt to repair. All repairs must be performed by an authorized service representative.
See pages 6-14 for full
installation instructions.

SECTION 2: PRODUCT OVERVIEW
*Measurements may vary due to natural material varia ons.
45
Feature Standard Op onal
Sanijet Pipeless Jets X
Re exology Fiberglass Tub X
Fully Motorized Seat and
Footrest X
Motorized Retractable
Armrest Doors X
Embedded Control Panel X
Power Drain/Discharge
Pump X
Relaxor® Heat & Massage X
Side Trays X
ADA Compliant X
Avonite Standard Op ons Upraded Op ons
Upholstery Naturso ™ Promessa® or
Ultraleather®
Included Features
Product Specications
Overall Width 32.5” (78.7 cm)
Shroud Width 22” (55.8 cm)
Shroud Height 15” (38.1 cm)
Length (armrest doors open) 73” (185.4 cm)
Length (armrest doors closed) 57” (144.8 cm)
Armrest Door Height 29.25” (74.3 cm)
Seat Height 21” (53.3 cm)
Backrest Cushion
Pillow
Armrest Door
Shroud
Drain Handle
Seat Cushion
Sprayer/Fill
Water Fill
Valve
Control Panel
*Chair shown with op onal nishes
SECTION 2: PRODUCT OVERVIEW
Footrest
Light
Tub Basin
Discharge Pump
Button (Optional)
Side Tray
(Optional)

SECTION 3: INSTALLATION
Installation Summary
NOTE: INSTALLER/OWNER BEARS ALL RESPONSIBILITIES TO COMPLY WITH ALL STATE AND
LOCAL CODES FOR PLUMBING AND ELECTRICAL WHEN INSTALLING THIS PRODUCT. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY VOID WARRANTY.
A licensed plumber and electrician must make the ulity connecons to this pedicure chair.
SECTION 3: INSTALLATION
Installation Location
The chosen install locaon must be level. The supporng oor structure must be able to
support the weight of the occupied unit. For the armrest doors to fully open, the base must
be mounted at least 14 inches from the wall, as illustrated below. (All measurements shown
in inches.)
6
Side View
Top View
7
32.50
14.00
59.50
5.50 7.90
Recommended Spacing
Wall
Wall
20”
minimum
20”
minimum
14”
minimum
14”
minimum
Option 1 - Standard
32.5”
22”
Option 2 - With Nail Trays
Wall
Wall
14”
minimum
24”
minimum
24”
minimum
48”
22”
14”
minimum
22.00
32.5”

SECTION 3: INSTALLATION SECTION 3: INSTALLATION
Power Cord
(8 ft long)
Cold Water Connection
(1/2” female pipe thread)
Hot Water Connection
(1/2” female pipe thread)
Drain/Discharge
Pump Connection
(1” female pipe thread)
Option 2 - Plumbed to a Floor Sink
Use this op on if your hot and cold water supply and drain line will be located in a oor
sink underneath the Contour. For this op on, there are several added steps to make the
connec ons:
1. The outer shroud will need to be removed (see instruc ons on page 13).
2. A licensed plumber will need to disconnect the internal connec ons from the manifold and
re-route the pipes as needed.
3. The power cord will need to be released from the strain relief to be plugged into the oor
outlet (if needed).
IMPORTANT: The diagram below shows where the oor sink can be located in RED.
Option 1 - Plumbed to the Wall (Recommended)
Use this op on if your hot and cold water supply and drain line will be coming from the wall,
behind the Contour. For this op on, all the internal plumbing connec ons have already been
made for you. All the plumber will need to do is connect the hot water supply line, cold water
supply line, and the drain line to the rear manifold.
Plumbing/Water Supply
• All plumbing connec ons, including the drain, must conform to all state and local codes.
• Maximum suggested opera ng temperature should not exceed 105°F (41°C), and the
maximum suggested supply water temperature should not exceed 120°F (49°C). State and local
codes may have di erent regula ons - please follow codes if di erent from suggested temperatures.
• Carefully connect the water supply ngs. Shut-o valves are recommended.
Drain Specication
Female 1.5” thread Male 1.25” thread
Male 2” thread
(Unit will ship with this
opening pre-connected to
the twist handle that opens/
closes the drain)
(Unit will ship with this opening capped o - plumbing will need to
be re-congured if using a gravity drain setup.)
(Unit will ship with this
opening pre-connected to an
elbow tting that attaches to
the discharge pump.)
If your drain and supply line loca on(s) do not allow you to use the rear manifold, a licensed
plumber will need to perform any needed re-con gura on. For reference, see the below
measurements of the Contour drain.
8
Wall
Electrical Service
110V/60 Hz or 220V/50 Hz GFCI protected grounded circuit must be used to supply power to
the Contour. Cu ng o the end of the electrical plug to hardwire the spa is NOT recommended,
and can void the warranty. (See page 3 for grounding instruc ons/safety warnings.)
14”
(min)
28.34”8.63”
7.5”
4.0” centerline from
drain
9
Option 3 - Plumbed to the Floor
Use this op on if your hot and cold water supply and drain line will be located in the
oor underneath the Contour. For this op on, there are several added steps to make the
connec ons:
1. The outer shroud will need to be removed (see instruc ons on page 13).
2. A licensed plumber will need to disconnect the internal connec ons from the manifold
and re-route the lines as needed. A 90 degree stop valve will be needed for the hot/cold
supply lines, and a 90 degree elbow will be needed for the drain line. Flexible hoses are highly
recommended for this applica on.
3. The power cord will need to be released from the strain relief to be plugged into the oor
outlet (if needed).
IMPORTANT: The diagram below shows where the connec ons can be located in RED.
The diagram below shows where the connec ons can be located in
3.0”
electronics plate
14.0” 3.0” 6.25”
hose bend
allowance zone
6.0”

SECTION 3: INSTALLATION SECTION 3: INSTALLATION
Backow Prevention
DOUBLE CHECK VALVE INFORMATION
American Faucet & Coatings Corporation (PART #19.10.007)
Each Contour comes with a dual backow preventave device pre-installed. This
device ulizes two (2) 15mm check valves that are cered to ANSI/NSF 61 and
ASME A112.18.3 (see detailed specicaon from manufacturer on the next page)
The ASME A112.18.3 standard, in Secon 8.1.1, indicates that “there shall be at
least two backow prevenon devices, in series”. The double check valve shown
below, installed on the tub supply valve, fullls this requirement. The 2 check
valves are installed in series and operate independently, per the standard.The
placement prevents backow into both the hot and cold supply lines.
*see next page for detailed specication and
certication information
DOUBLE CHECK VALVE PLACEMENT
Hot & Cold
Supply Lines
Supply line to
tub ll/sprayer
Double Check
Valve
Backow Prevention
10 11
NOTE: It is mandatory in some states to install addional backow protecon (reverse backow)
on the main hot and cold water supply lines. This requirement is the responsibility of the facility
owner, and cannot be fullled by the individual Contour units.

SECTION 3: INSTALLATION SECTION 3: INSTALLATION
Tools & Hardware Needed
• 1/2” crescent wrench
• 3/16” allen wrench
• 3 shoulder bolts
• 3 hex nuts
• 5 plasc washers
• 6 metal washers
Included: Not Included:
*All pieces required for installaon.
Initial Assembly
1. Attach Seat Back
The Contour seat back is shipped detached in order to minimize shipping costs and
damage. Follow the diagram below to aach each side of the seat back to the frame.
Shoulder
Bolt Metal
Washer Plastic
Washer
Seat back post
Plastic
Washer Metal
Washer
Hex
Nut
1. Place metal washer followed by plasc washer onto the shoulder bolt.
2. Insert the shoulder bolt through the seat back mounng post, then through
the seat back post.
3. Place plasc washer followed by metal washer onto the shoulder bolt.
4. Using the crescent wrench and allen wrench, ghten the shoulder bolt.
5. Repeat for opposite side of the seat back.
Seat back
mounting post
2. Secure Seat Back Tilt Motor
Aer the seat back is aached using the instrucons on the previous page, aach the
seat back motor to the seat back frame.
1. Locate the seat back motor and seat back frame aachment point.
2. Place metal washer onto the shoulder bolt.
3. Insert shoulder bolt through one side of the seat back motor mount, then seat
back frame aachment point, and the other side of the motor mount.
4. Place plasc washer followed by metal washer onto the shoulder bolt.
5. Using the crescent wrench and allen wrench, ghten the shoulder bolt.
Seat back
motor
seat back frame attachment point
Shoulder
Bolt
Metal Washer Plastic
Washer
Metal
Washer
Hex Nut
12 13
3. Remove Shroud (if needed)
1. Push and hold the “Open” buon unl the armrest doors are fully open
2. Remove the screws securing the shroud to the frame, one on each side (located
towards the boom of the shroud)
3. Carefully remove the cap from the drain handle, and remove the screw securing
the handle to the shroud.
4. Carefully pull the shroud o the frame
5. NOTE: If you have a discharge pump, you will need to disconnect the discharge
pump buon wire connector before fully pulling the shroud o.
The shroud will only need to be removed if plumbing reconguraon is needed. See
pages 8-9 to determine if this is needed.

SECTION 3: INSTALLATION
14
Electrical Specications
15
Spec North America Europe/Asia
Input Voltage 120 VAC 220 VAC
Input Frequency 60 Hz 50 Hz
Total Consumpon
- All Opons 10.5 Amps Max 5.7 Amps Max
Consumpon -
Standard Contour 7.5 Amps Max 4.1 Amps Max
Consumpon -
Relaxor Addional 3 Amps (Max) Addional 1.6 Amps (Max)
Discharge Pump Specication
Motor Design Single-phase synchronous motor
Flow Rate (120V) 24 l/min at 0, 1 bar
Flow Rate (220V) 20 l/min at 0, 1 bar
Duty Cycle Connuous
Power Consumpon See electrical specicaon (next page)
Sanijet® Jet System Specication
Motor Design Single speed, electronic spherical DC motor with magnec rotor
impeller
Motor Materials Thermoplasc jet, motor, and case assembly; stainless steel rotor
impeller
Safety Features Safety shuto sensor, dry-run/thermal overload protecon
Power Consumpon See electrical specicaon (next page)
Warranty Information
Living Earth Cras (LEC) oers an industry best warranty against defects in materials, design,
and workmanship, to the original owner, as follows:
• Frame - lifeme warranty*
• Foam and upholstery covering - warranted for three (3) years
• Motors, controls, electronics - warranted for two (2) years, including parts and labor
• Accessories and opons - warranted for one (1) year, unless otherwise noted
LEC may repair or replace defecve components at our discreon. LEC will return the warranted
product, standard shipping pre-paid, to customers in the connental US. Internaonal customers
are responsible for any applicable dues and taxes, as well as all shipping charges inbound and
outbound. Normal wear and tear, and costs associated with maintenance procedures, and
damage caused by accident, misuse, improper maintenance, harsh operang environments or
neglect (which includes tears in the upholstery and damage caused by harsh chemical-based
cleaners) are not covered under this warranty. All warranes are limited to repair or replacement,
at LEC’s discreon, unless otherwise stated.
*Lifeme warranty applies to the original owner or for 5 years aer the model is disconnued,
or 5 years for private label chairs.
Does the Contour have backow prevenon?
Yes - see pages 10-11 for backow prevenon details.
Do I sll have to install backow prevenon on my main water supply line?
This is enrely dependent on your local and/or state codes. A licensed plumber with knowledge of
your local and/or state codes can answer this queson for you.
Do we need to install a p-trap?
Check with the licensed plumber performing the install. It is dependent on your drain locaon.
Can you provide a leer to my city inspector stang my electrical and/or plumbing setup is
acceptable?
Unfortunately not. In this document, we have provided all the informaon that a licensed plumber
and electrician would need to perform the proper install that adheres to local and state codes. Living
Earth Cras does not have knowledge of all local and state codes and therefore is not qualied to
advise on individual setup quesons. If an inspector has quesons about how your plumbing and/
or electrical is being set up, you will need to contact your plumber and/or electrician.
Does the Contour have GFI/GFCI built in?
There are no GFI/GFCIs built in to the system - we require a GFCI protected grounded circuit to
supply power to the Contour.
Frequently Asked Questions

Notes
16 17

Contact Us
Living Earth Crafts
3210 Executive Ridge
Vista, CA. 92081
(800) 358-8292
(760) 597-2155 Int’l
(866) 449-8872 fax
Hours of operation:
Monday - Friday
8:00 a.m. to 5 p.m. PST
Saturday - Sunday
Closed
Visit us online at: livingearthcrafts.com
Read our blog at: livingearthcrafts.com/blog
Join us on Facebook®
This manual suits for next models
1
Table of contents
Other Living Earth Indoor Furnishing manuals
Popular Indoor Furnishing manuals by other brands

Atlantic Furniture
Atlantic Furniture Mission Printer Stand With Shelf AH10224 Assembly instructions

Walker Edison
Walker Edison W52CLA3D Assembly instructions

Hatco
Hatco FTBX Series Installation and operating manual

Triarch
Triarch 31553 Assembly instructions

Kvik
Kvik P15675 Assembly instructions

Altair
Altair WILDY 546048-BO-GW-NM manual