LOREN CONTROLS SMART SW User manual

SMART SW
1 - PROGRAMMING DESCRIPTION
2 - INSTALLATION
3 - PROGRAMMING
4 - FUNCTIONS
5- WiFi SERVER COMMANDS
6 - PASSWORD
7 - CLOCK
8 - PARAMETERS
9 - KE FOB
- System operation
- Keyfob registration procedure
- Keyfob cloning procedure
- Battery replacement
10 - CHARACTERISTICS DATA
11 - WARRANT
12 - SWITCH PARAMETERS READ WRITE
13 - ANDROID SMARTPHONE APP SCREEN SEQUENCES

DESCRIPTION
Smart Sw is a versatile device for the home & building automation. It can perform several functions easily
programmable with the dedicated Android App and be remotely controlled by one or more key-fobs with a high degree
of digital protection.
INSTALLATION
Warning! Work on electrical connection only after the supply voltage has been switched off.
Smart Sw enclosure is suitable to be installed inside electrical junction boxes electronic devices or to be fixed on wall.
To access the 10A model terminal blocks remove the 4 screws which hold the 2 orange protection covers.
Terminal blocks connection:
The 2 poles terminal block has to be connected to the power supply (80 - 240V AC) following line and neutral symbols
the 3 pole block is connected to the contacts of a relay (voltage free) the sticker show the connection diagram where
NC indicates the normally CLOSE contact NO indicates the normally open contact and COM indicates the common
contact.
fig 1: 6A switch fig 2: 10A switch
PROGRAMMING
Download and install the Android App “LC Param Manager” for the parameters setting from Google Play Store. (be
sure the phone is equipped with the NFC antenna).
Setting up of switch parameters is done wireless via Near FielCommunication (NFC) technology. When asked by the
App to communicate the phone has to be placed on top of the Smart enclosure where the NFC symbol is.
FUNCTIONS
Smart Sw can perform different functions selectable from the “Set up menu” (accessible via the
“Select Switch Type” button) like:
-Remote Control ON/OFF SWITCH: The switch is turned ON and OFF by keyfob.
-Remote Control ON/OFF TIME SWITCH: Like a timer switch enabled by keyfob turn ON and OFF according to
daily/weekly programmable time charts.
-Remote Control DUTY CYCLE SWITCH: The switch enabled by keyfob turn ON an OFF cyclically according to
programmable duty cycle times.
-Remote Control PULSE SWITCH: The switch enabled by keyfob turn ON briefly (impulses) a certain amount of
times. Duration number and lapse between impulses is programmable by App.
-ON/OFF TIME SWITCH: The switch is always enabled and turn ON and OFF according to daily/weekly
programmable time charts.
WiFi SERVER COMMANDS
The device can be controlled as well as the keyfobs also with an internet browser like Firefox Chrome Opera.
For this purpose it's available the “WiFi server bridge 433” whose detailed description is given on our site.

PASSWORD
It's possible to set a password from the App to block parameter modification and new keyfobs registration. PW setting
can be done from MENU->SET UP MENU->Change password.
N.B. If a new password is to be activated leave empty the textfield “Current Password” if instead the password is to be
deactivated leave empty textfiels “New Password” and “Re-type Password”. If the password is to be changed fill all the
textfields.
CLOCK
To turn ON the switch according to time charts defined using the “Remote Control ON/OFF TIME SWITCH” e
“ON/OFF TIME SWITCH” functions Smat Sw utilize an integrated clock.
The App allow to update date and time of the clock. To do that enter the “Clock Adjust” page (Menu → Daily
schedule\Weekly schedule → Clock Adjust) e press the “Device Time/Date Adjust“ button.
The internal clock is able to retain date and time for more than 24 hours in case of “black out”.
The eventual loss of date and time get signalled whit an alternated red/green led that imply the permanent deactivation
of the switch till a new time update.
PARAMETERS MANAGEABLE B THE APP
PARAMETER Min-Max Valore
iniziale
DESCRIPTION
1COMMAND TYPE 1 - 2 1 Type of command attributed to key-fobs buttons:
1=Toggle (negation of the previous state)
2=Function_key (one button turns ON and another button turns OFF the
switch)
2COMMAND MODE 1 - 2 1 Command mode: 1= single_click: a single push of the button is sufficient
to commute the switch.
2= double_click: the first push shows the state of the switch and a second
push (done while led is active) commute the state of the switch.
3STATE RETENTION 0 - 2 0 State resume after a shut-down
0 = No
1 = Yes only if "MAX ON TIME"=0
2 = Yes with turning off time “MAX ON TIME” reloaded.
4MAX ON TIME 0 - 100000 0 Time after which the switch get automatically turned OFF following an
ON command (0 = infinite).
5MAX ON TIME UM 0 - 2 0 “OFF DELAY” unit of measurement: 0 = sec 1 = min 2 = hours.
6ON TIME DC 0 - 100000 0 Duty Cycle ON time.
7OFF TIME DC 0 - 100000 10 Duty Cycle OFF time.
8DC TIME UM 0 - 2 0 “ON TIME DC” and “OFF TIME DC” unit of measurement;
0 = sec 1 = min 2 = hours.
9CYCLE TIME 0 - 100000 0 “Pulse Switch” cycle duration.
10 CYCLE TIME UM 0 - 2 0 “CYCLE TIME” unit of measurement: 0 = sec 1 = min 2 = hours.
11 IMPULSE NUMBER 0 - 100000 0 Number of impulses (0 = infinite).
12 IMPULSE TIME 1 - 250 1 Impulse duration (s).
13 LED MODE 0 - 5 0 Smart Sw led signalling mode:
0= led always on according to the raly state (ON = red
OFF = green) *
1= led flash to signal a relay state change:
(OFF->ON) = red flash (ON->OFF) = green flash
2 = if configured as “hour switch”:
green led ON when device OFF red led ON when device ON;
else:
green led power ON yellow (red+green) led supply and
relay ON;
3 = green led flash to signal command reception
red led signal relay ON;
4 = green led during signal reception red led during signal
transmission;
5 = leds always OFF.
* When the switch is configured as ON/OFF TIME SWITCH
led signaling is as parameter=0 even if the parameter value is different.
The keyfob led in this case indicate the switch ON/OFF ( green=
disactivated red = activated)
14 DEL POWER ON 0 - 10 1 Relay activation delay after a “power outage” to avoid a simultaneous
activation of too many loads.

15 TX POWER 1 - 5 5 Switch RF transmission power level
(1=+2 dB 2=+5 dB 3=+8 dB 4=+13 dB 5=+20 dB).
16 KEYS POWER 1 - 3 3 Key-fob RF transmission power level
(1=+5 dB 2=+10 dB 3=+12 dB).
17 PROG CHANNEL 1 - 30 30 Programmed radio channel
18 CHAN SEL MODE 0 - 2 0 Radio channel selection:
0= standard channel
1= channel selected from “PROG CHANNEL” parameter.
2= channel randomly selected between those available
19 CMD REPEAT TIMES 0 - 2 0 Command repetition without a received reply (0 = don't repeat)
20 ADDRESS BYTE 3 - 8 3 Address byte number
21 SECURITY BYTE 6 - 16 6 Security byte number
22 MAX COHERENCE ERR 1 - 20 3 Highest number of incoherent commands in the assigned time window
23 WINDOW COUNT ERR 1 - 2880 1 Incoherent commands counting time window (min)
24 INHIBIT TIME 0 - 3600 10 Inhibition time after incoherent errors threshold crossing (sec)
25 KEY COPY ENABLE 0 - 2 1 Enabling of keyfob button cloning
0= disabled
1= buttons can be cloned but “clones” are not allowed to be cloned
2= buttons can be cloned and also “clones” are allowed to be cloned.
KE FOB
The pocket sized keyfob has two buttons and three colours (green/red/yellow) signalling led.
Before being used it must first be registered to it's “slave” Smart Sw device.
Registration procedure attribute to the single button a code to control the “slave device”.
The procedure therefore has to be repeated for every button which we want to relate with a Smart Sw.
System operation
Keyfob buttons can perform in two different modes according to the value attributed to “COMMAND MODE”
parameter. With COMMAND MODE=1 a single push of a button make the state of the switch change and the led
colour show the new state (green=ON e red=OFF). With COMMAND MODE=2 a single push of a shows present state
of the Smart Sw (green=ON e red=OFF) to change present state the button has to be pressed a second time while the
led indicating present state is still on.
The ON/OFF action can be managed by two buttons (one to activate and the other to deactivate the Smart Sw) if
parameter “COMMAND TYPE” = 2 or by just one button if parameter “COMMAND TYPE”=1.
Please note. Changing Smart Switch parameters can imply the generation of a new digital security key so the
impossibility to command the switch with previous registered keyfobs.
In that case the App notify the operator with a warning of the consequent loss of communication with previous keyfobs
and waits for confirmation.
There is no limit to the buttons associable with a Smart Switch keyfobs can also be registered and command different
Smart Sw. Every single button though can command one single device.
Keyfob registration procedure
To register a new keyfob start the App and push the “Start NFC Connection” then put in contact your phone antenna
with the top surface of the control unit where the NFC symbol is. After a few moments device records will appear on
the screen together with buttons to access the general settings menu. To proceed push the “Device Re istration” button
and again put in contact your phone with the NFC symbol on the sticker now the control unit LED begin to blink
yellow for a few seconds allowing registration of a new keyfob button which is achieved by pushing the button for
about 3 seconds.
Registration is confirmed by the key-fob with a series of 4 green blinks. If the key-fob was previously registered to
another Smart Sw it's necessary to erase the previous registration before attempting a new registration.
Please note If when pushing the button it immediately emits a single yellow blink it means that the button was already
registered and to be registered again the previous registration need to be erased.
To do that you need to push the button for about 10 seconds until the green LED start to blink release the button and
push it again for about 10 seconds until the red LED blinks briefly.
Button is erased if when pushing it a yellow blink appears after about 3 seconds.
Keyfob cloning procedure

If a button has been registered with parameter “KEY COPY ENABLE”=1 it is possible to clone that button to another
keyfob by pressing the button for about 10 s until the keyfob yellow led starts to blink keeping the button pressed now
press the button that need to become a clone until it's relative green led blinks briefly confirming the occurred clonation.
The button so obtained cannot be used to do other clonation. If pushed for about 10 seconds the cloned button generate
a green led blink instead of a yellow blink.
If the original button has been registered with parameter “KEY COPY ENABLE”=2 then also its clones can be
themselves cloned.
Battery replacement
Key-fob is powered by a CR2032 battery type. For the replacement the screws on the enclosure have to be removed.
Then open the shell enclosure using a small flat blade screwdriver and remove the PCB contained inside the shell. Push
the battery out of the battery older and insert a new one respecting the battery polarity. Reposition the PCB in the half
shell which has 2 pins making sure the battery side face down close the shell and screw the 2 previously removed
screws.
CHARACTERISTICS DATA
SMART SW
Power supply 80 — 240 VAC 50/60Hz
Power drain (with relay ON) ~ 0 15 W ( ~ 0 6W)
Parameters read/write Port NFC prot. IEC 14443 Type B
Enclosure dimensions 29x45x115 mm
Weight ~ 80 gr.
Enclosure protection IP54
Relay current ratings 240 VAC / 10A ; 30VDC / 10A
Date and time retention in case of “black out” >24 ore
Operating temperature -10 — +50°C
KEY-FPOB
Number of buttons 2- 4
Shell dimensions 56 8x44x14 5mm
Operating frequency shell ISM 433 MHz
Transmitted signal power < 10dBmW
Shell protection IP65
Battery type CR2032
Battery life * > 5 years
Radio range 20 / 50 m
Operating temperature -10 — +50°C
* life et calculated for 10 commands per day
WARRANT
The warranty period of 2 years start on day of purchase.
Warranty doesn't cover damages caused by:
- wrong installation
- failure to observe these instructions
- tampering modifications or reparation attempt
- wrong use
- failure to observe safety regulation in force

- majeure force (e.g. over-voltages fire etc.)
Warranty does not include direct or indirect damages due to device defects or costs derived from installation or removal
labour.
In case of malfunction will be our liberty to choose if to replace fix or refund the cost of the device.
SWITCH PARAMETERS READ WRITE WITH SMARTPHONE
To obtain a connection between smatrphone and control unit take the following steps:
1- Make sure the control unit is connected to AC power source (led on).
2- Start the dedicated Android application downloadable at http://www.lorencontrols.eu
3- Push the ”Start NFC Connection” button under the “Loren Controls” logo.
4- Like asked by message on the screen place the phone on top of the Smart Sw enclosure where the NFC symbol is.
5- If the connection is activated another screen will appear showing Software/Hardware data and 2 buttons.
The first button “SET UP MENU“ access the parameter setting menu and the second button
“DEVICE REGISTRATION“ start the sensor registration procedure (check next paragraph to see phone screenshots)
If connection fail an error message appears.
6- To proceed with the parameter read/write or a new key-fob registration push the dedicated button and place the phone
on the Smart Sw enclosure like described above.
ANDROID SMARTPHONE APP SCREEN SEQUENCES
Shown below are some screenshots of the app dedicated to the management of parameters.
The device is supplied with a set of default values.
Parameter modification is allowed only within relative range if the inserted parameter is out of range it is
automatically brought back to its previous value.
Under every screenshot it's “button press path” is specified. When not used the App closes itself after a pre-set time.

“First ima e of the App” Start NFC Connection Start NFC Connection > SET_UP MENU
Start NFC Connection > SET UP MENU
> Select S itch Type
Start NFC Connection > SET UP MENU
> Parameters settings Start NFC Connection > SET UP MENU
> Daily schedule

Start NFC Connection >SET UP MENU
> eekly schedule Start NFC Connection > SET UP MENU
> Daily schedule > Clock Adjust
Start NFC Connection > SET UP MENU
> Change Pass ord
Start NFC Connection > SET UP MENU
> Security settings
Start NFC Connection > SET UP MENU
> Radio settings
Table of contents
Popular Home Automation manuals by other brands

netelec
netelec HUB15B-PIR user manuel

urmet domus
urmet domus Bitron Home 902010/21 Quick start manual

inohom
inohom Nova Panel H10 Technical manual

GILBARCO VEEDER-ROOT
GILBARCO VEEDER-ROOT PA0306 installation instructions

RADEMACHER
RADEMACHER RolloTron Basis 1100 Translation of the Original Operating and Assembly Manual

Buhler
Buhler MAYV Series operating instructions