MEFE 67TB1 User manual

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 1
+617 3283 4536
Free AU 1800 669 006
Operating Manual
Auto Toilet Flush
For top buon type cisterns
CAT 67TB1
Revision 3

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 2
+617 3283 4536
Free AU 1800 669 006
Sensor Appearance and Instrucon:
A. SET UP MODE (le) - Adjust the Half/Low ush cycle me by holding a
magnec wand (part 13) against the right side (D) circular magnec target unl
the desired water release is achieved. Note the speed and distance of ush
motor up/down cycle and adjust accordingly.
B. PRESENCE DETECTION - A computerised Sensor measures the “me-at-the
-toilet” and then acvates a ush motor inside the tank which lis the ush
lever for either a half/low-ush or full/large ush as required.
C. LOW BATTERIES - It will ash when the baery is low, please replace the
baery.
D. MAGNETIC TARGET (half/low ush)
NOTE 1: Aer setup is complete, if the half ush water volume is insucient or
too much (based on personal demand), simply repeat the Set Up Mode instruc-
ons located above at A. The memory model of sensor must be reset aer re-
placing baeries.
NOTE 2: When computerised Sensor starts to measure the “me-at-toilet” the
Sensor presence detecon LED will ash for 10 seconds above (maximum ush
cycle: 10 secs) by standing in front of the Sensor which then acvates a ush
motor inside the tank which lis the ush lever for either a half/low ush or
full/large ush as required.
Specicaons:
Model/Product name CAT 67TB1—auto toilet ush
Power 6x AA baeries
Flush Method Auto-inducon, Two-stage ush (low/large water volume)
Detecon Rang 80cm +/- 10cm
Sensor
Half Flush Timer: 10-60 secs
Full Flush Timer: >60 secs
Maximum Flush Cycle: 10 secs
Applicable toilet tank style Central pressing type toilet ush buon (oval or round appear-
ance with a diameter of 53mm) located in the centre of the tank.

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 3
+617 3283 4536
Free AU 1800 669 006
Precauons:
1. This electronic dual-ush toilet conversion system ts most top buon ushing toilets.
2. The Sensor has the funcon of self-learning, determining whether the sensor distance has at least 100 cm
above to the wall or any obstacles, otherwise it will shorten the detecon to just 40-50cm.
3. Upon powering up the Sensor will automacally detect the distance in 1 min, the Sensor presence detecon
LED will ash, please keep any obstacles or mirrored surfaces out of the detecon beam at least 100cm dur-
ing detecng to prevent false direcon and random ush.
4. The Sensor must not be obstructed by any reectors, such as mirrors, glossy bright objects etc. as they can
cause the distance to reduce to 30cm.
5. Please keep the detecon window clean, any dirt, smudges or water drippings will aect the sensivity of the
sensor.
6. Anyme the baeries (6 standard AA alkaline) are replaced or the Sensor range needs to be recalibrated,
simply repeat reseng. To prevent from false detecon and random ushing, keep any obstacles or mirrored
surfaces out of the detecon beam.
Various Parts:

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 4
+617 3283 4536
Free AU 1800 669 006
Installaon Instrucons:
Applicable to central-pressing type
toilets, the inside ush buon as
shown in gure 1—with low/large
water volume buon or single ush
buon.
Li the toilet tank cover and then ip
to the inside.
Unscrew the xing buon on the tank
cover. (If your toilet or buon style is
dierent from gure above, please
refer to the instrucon manual for
your toilet to remove ush buon.)
Remove the original ush buon and
store somewhere safe.
Put the tank cover back on.
Take out the (10) Depth Ruler and
measure the distance from top of the
Flush Buon hole to top of the inter-
nal buon on the Flush Valve.
Place the (10) Depth Ruler in buon
hole & press downward slowly by
moving the P-Ruler to touch the top
of the internal buon on the Flush
Valve.
Remove the (10) Depth Ruler that has
been measured (Arrows in gure 8
represent total length of (8) blocks to
assemble.)
Take out the (8) Blocks and (9) Spin
Washers.

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 5
+617 3283 4536
Free AU 1800 669 006
Installaon Instrucons:
Please assemble the (8) Blocks and (9)
Spin Washers together according to
length that was measured by (10)
Depth Ruler. Note: (8) Blocks come in
dierent sizes, use as necessary, align
to notch at top.
Completed Assembly
Remove the (7) Fixing Gasket by un-
screwing an-clockwise, and take
down (6) Oval or Round Washer to-
gether along with (7) Fixing Gasket
from (5) Flush Motor.
Install the (5) Flush Motor onto the
tank cover and ensure power cable is
facing the wall.
Reghten (6) Oval or Round Washer
and (7) Fixing Gasket in order by turn-
ing clockwise.
The assembly (8) Blocks should be
vercally inserted into the centre of
the (5) Flush Motor hole.
Replace the tank cover gently and
check if boom of assembly (8) Blocks
on (5) Flush Motor, just touch the top
of the internal buon. Appropriately
readjust the (8) Blocks. If tank cover is
plasc, use the (12) Transparent Sck-
ers on all sides between tank cover
and tank body to prevent cover liing.
Pull out the (13) installaon scker,
tear o the small scker on inside of
the doed box and paste it around
the toilet used as sign of warning.
Align the boom edge of (13) installa-
on demonstraon scker to the top
edge of toilet lid, and ax to the wall.

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 6
+617 3283 4536
Free AU 1800 669 006
Installaon Instrucons:
Remove the (4) Back plate and align
with the groove in the middle of (13)
Install scker. Ax to the wall using
your preferred method, then peel o
the (13) Install scker from wall.
Remove the (1) sensor from its wall
plate by sliding upward and o. Re-
move the (2) baery cover with small
Philips screwdriver.
Place 6 x AA baeries in and check
that the silicone gasket inside the
baery compartment is not out of
place and is in good condion.
Reinstall the (3) screws of (2) baery
cover and replace the sensor back on
the wall.
Hide the power cable in the (11) deco-
rator cover and hook the groove of
back plate with claw on the (11) deco-
rator cover.
Aer installaon if you feel the (11)
decorave cover is too long, cut the
horizontal groves on the (11) decora-
tor cover to the required length.

MEFE—Mitchell Engineering Food Equipment Pty Ltd
23 Storie Street Clontarf QLD 4019 Australia
www.mefe.com.au | [email protected]
Page 7
+617 3283 4536
Free AU 1800 669 006
Trouble Shoong:
Issue Possible Cause Soluon
Replace baery
indicator ashes
Lack of Power Replace the baeries
Body Failure Take out baeries rst, wait for 30 minutes then reload the
machine, let the sensor automacally set again.
Inducon / Power
indicator no icker,
no acon
Body Failure Take out baeries rst, wait for 30 minutes then reload the
machine, let the sensor automacally set again.
Incomplete during the inial automac
seng process
Insucient power or incorrect baery
polarity installaon
Please replace the baery.
Please check if the posive and negave baeries are in-
stalled correctly.
The baery is not covered Please pay aenon to whether the baery cover is stuck or
not closed.
Fixed obstacles (such as toilet paper) with-
in 10cm of the front of the sensor
Please remove the obstacles and keep the distance of 130cm
or more. The system will automacally reset and return to
normal aer 30 minutes.
The sensor detects obstacles or reecve
objects (mirrors, walls, boards, cabinets or
various xtures)
Please remove obstacles mirrors or reecve objects and
keep a distance of at least 130cm
Sensing / Power
indicator blinks
connuously
The sensor is placed too low and is
blocked by the toilet cover.
Please adjust the sensor posion so that the sensor window
exceeds the top edge of the toilet lid.
When the system is automacally set, it
senses someone or a dynamic object.
Take out baeries rst, wait for 30 minutes, then reload it, let
the sensor automacally set again, make sure there is no ob-
ject within 130 cm in front of the sensor.
Sensor surface has stains Please be careful to avoid scratching, so as not to aect the
infrared sensing distance.
The toilet in which the sensor is installed is
less than 130 cm from the wall.
A toilet with a minimum of 130 cm or more from the wall in
front of the sensor can be used.
Bad Baery Please replace the baery
Baery Life is too
short Lack of power Please replace the baery (use the lithium or alkaline baery
produced within half a year to maintain the best use me).
Not sensing or
need to be very
close
Sensing window surface with stains or
water droplets
Gently wipe the sensor window to avoid scratching, so as not
to aect the sensing window
There is an obstacle in front of the sensor
when it is automacally set for the rst
me.
Take out the baery rst, wait for 30 minutes, then re-load it,
let the sensor automacally set again , make sure there are
no obstacles within 130cm of sensor.
Table of contents