INTRODUCTION
Model TLSP is a two-way talk/listen vandal resistant speaker/microphone, designed for correctional facilities or
areas of high vandalism. When functioning as part of a Louroe Audio Monitoring System, Model TLSP provides
two-way talk/listen capabilities between the remote area (jail cells, etc) and the Louroe Base Station. The unit
consists of an electret condenser microphone and a 3” speaker fitted to a special tone path and mounted to an
11 gauge stainless steel face plate. The tone path positioning protects the microphone and speaker from
vandalism. Included with Model TLSP is a 6”x6”x4” back box and security hardware.
Model TLSP-F is for flush mounting to a ceiling or wall
Model TLSP-S is for surface mounting to a ceiling or wall
MODEL TLSP-F/TLSP-S
SPEAKER/MICROPHONE
INSTALLATION AND OPERATING INSTRUCTIONS
TLSP-F Faceplate is 7”x7”
TLSP-S Faceplate is 6”x6”
Back Box for both units is 6”x6”x4”
6955 VALJEAN AVE, VAN NUYS, CA 91406
PH: (818)994-6498 / FAX: (818)994-6458
/ www.louroe.com[email protected]
®
Page 1 of 4
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
website: www.louroe.com e-mail: [email protected]
(818)
®
tlsp_inst_3/15
MODEL TLSP-F MODEL TLSP-S
CONNECTING MODEL TLSP-F / TLSP-W TO A LOUROE BASE STATION
The following procedure pertains to all Louroe Base Stations with
talkback
After wiring connections are made at Model TLSP, run recommended 4 conductor cable to the Louroe Base Station and
connect as follows. Connections are located at rear panel of the base station.
1) RED wire (12Vdc) goes to terminal “A” of Base Station (zone 1)
2) BLACK wire (Audio Output) goes to terminal “B” of Base Station (zone 1)
3) BARE wire (ground) goes to terminal “C” of Base Station (zone 1)
4) GREEN speaker wire goes to “TB” (talkback) terminal of Base Station (zone 1)
5) WHITE speaker wire goes to “G” (ground) terminal of Base Station (zone 1)
Repeat same procedure for the remaining zones
Microphone Connections
Located behind the speaker portion of TLSP is a PC board with a small terminal block marked A, B, C.
Using shielded portion of recommended wiring: 1) RED wire goes to terminal A (12 Vdc supply)
2) Black wire goes to terminal B (audio output)
3) Bare wire (drain) goes to terminal C (ground)
Speaker Connections
Mounted next to speaker is a 70V transformer with two lead wires GREEN (positive) and WHITE (ground). Using wire
nuts, connect these two wires to the unshielded GREEN and WHITE cables of recommended wiring (West Penn 356 or
equivalent)
MICROPHONE AND SPEAKER
WIRING CONNECTIONS FOR TLSP MICROPHONE AND SPEAKER
Page 2 of 4
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
website: www.louroe.com e-mail: [email protected]
(818)
®
INSTALLATION AND OPERATING INSTRUCTIONS
tlsp_inst_3/15
SPECIFICATIONS (Model TLSP-F and TLSP-S)
Output of microphone (Mic)
Frequency Response (Mic)
Current Drain (mic)
Speaker
Line Level (0 dB, 600W@ 1KW)
40 Hz to 15 kHz
10 mA
3”, 2W w/ 70V transformer
Faceplate (TLSP-S) Vandal Resistant
Stainless Steel
Faceplate (TLSP-F)
Backbox
Weight
Shipping Weight
6”L x 6”W
7”L x 7”W
6”H x 6”W x 4”D
4 lbs
7 lbs
REAR OF TLSP SPEAKER/MICROPHONE
WIRING DIAGRAM FOR MODEL TLSP-F / TLSP-S
SPEAKER/MICROPHONE
Terminal Block Identification
Microphone
A - 12Vdc (red)
B - Audio Output (black)
C - Ground (bare)
Green wire (positive)
White wire (negative)
are speaker connections
NOTE: WHEN USING CABLE FROM OTHER
MANUFACTURERS, COLOR CODE
MAY VARY
TO LOUROE
BASE STATION
REFER TO PAGE 1
DIAGRAM OR TO THE SPECIFIC
BASE STATION INSTALLATION
INSTRUCTIONS FOR CONNECTIONS
GREEN
WHITE
WIRE NUT
GREEN
SPEAKER WIRE (POSITIVE) WHITE
SPEAKER WIRE (NEGATIVE)
A
B
C
TRANSFORMER (70V)
RED
BLACK
BARE
WIRING REQUIREMENTS
4 Conductor consisting of:
+
2 Conductor shielded, 20 gauge
with 22 gauge drain (microphone
connection)
+
2 Conductor unshielded, 18 gauge
(speaker connection)
All in the same jacket
West Penn 356 or equivalent
Page 3 of 4
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
website: www.louroe.com e-mail: [email protected]
(818)
®
INSTALLATION AND OPERATING INSTRUCTIONS
tlsp_inst_3/15
MANUFACTURED
IN THE
IMPORTANT NOTICE
When this equipment is used as part of an
audio monitoring system, the law requires
that the public be given notice of AUDIO
MONITORING ON THE PREMISES. A
decal notice is included with each
microphone shipped.
Federal Law References:
Federal Regulations, US Code, Title 18.
Crime and Criminal Procedure, Sec 2510.
Page 4 of 4
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
website: www.louroe.com e-mail: [email protected]
(818)
®
WARRANTY
LOUROE ELECTRONICS warrants that at the time of shipment products manufactured by LOUROE ELECTRONICS to be free of defects in material and workmanship.
Should a defect appear within one year (12 months) from date of shipment, LOUROE ELECTRONICS will, at its sole discretion, repair or replace the defective equipment.
This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS .
This warranty does not extend to any Louroe product that has been subjected to improper or incorrect installation, misuse, accident, or in violation of installation
instructions provided by LOUROE ELECTRONICS.
Returned shipments to LOUROE ELECTRONICS shall be at customer’s expense. LOUROE ELECTRONICS will return the equipment prepaid via best way.
®
®
®
®
®
®
AUDIO
MONITORING
On
These Premises
®
INSTALLATION AND OPERATING INSTRUCTIONS
tlsp_inst_3/15

This manual suits for next models

1

Popular Intercom System manuals by other brands

Akuvox R20B Series Admin guide

Akuvox

Akuvox R20B Series Admin guide

merten U.motion MEG6910-0034 Installation and configuration instructions

merten

merten U.motion MEG6910-0034 Installation and configuration instructions

RTS RMS300 Technical data

RTS

RTS RMS300 Technical data

Cabletech URZ0321 user manual

Cabletech

Cabletech URZ0321 user manual

KOCOM KDP-601AM Manual for operation and installation

KOCOM

KOCOM KDP-601AM Manual for operation and installation

Akuvox R29 Series Admin guide

Akuvox

Akuvox R29 Series Admin guide

KOCOM KAL-S302 manual

KOCOM

KOCOM KAL-S302 manual

galmar SV-701 manual

galmar

galmar SV-701 manual

Comelit 8461V Technical manual

Comelit

Comelit 8461V Technical manual

Vimar ELVOX 7559 manual

Vimar

Vimar ELVOX 7559 manual

Carus ARGOS CAE3 02-IP-015 Series Product information

Carus

Carus ARGOS CAE3 02-IP-015 Series Product information

SSS Siedle MOCT 711 Series operating instructions

SSS Siedle

SSS Siedle MOCT 711 Series operating instructions

MiTEC MIC-120 Series User instruction

MiTEC

MiTEC MIC-120 Series User instruction

Commax DP-4VHP user manual

Commax

Commax DP-4VHP user manual

Panasonic VL-WD619 Getting started

Panasonic

Panasonic VL-WD619 Getting started

Vimar Elvox 40920.P1 user manual

Vimar

Vimar Elvox 40920.P1 user manual

Elite Security Products Aperta APWIFIDSBP manual

Elite Security Products

Elite Security Products Aperta APWIFIDSBP manual

Anchor PortaCom COM-40FC Specifications

Anchor

Anchor PortaCom COM-40FC Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.