LynTec SS-2 User manual

LOCKED
LOCKED
ON
OFF
OFF
ON
OFF
ON
OFF
ON
ON
OFF
.770" x .535"
POWER AMPS
OUTSIDE
ONLY
OUTSIDE
ONLY
VIDEO SYSTEM
A.C. POWER
Power Amplifiers
ONLY
ONLY
ONLY
PROJECTOR
A.C. POWER
AUTO
MIX
AUTO
MIX
LOWER BOWL
LOWER BOWL
ONLY
LynTec.com LynTec.com LynTec.com LynTec.com LynTec.com
LynTec.com LynTec.com LynTec.com LynTec.com LynTec.com
A partial sample of
custom film legends
Custom switch legends you can print on your laser printer
See http://www.lyntec.com/139-0309_CSLF-1_Film.pdf
SOUND SYSTEM
A.C. POWER
FLASHES DURING SEQUENCING
ON
LynTec.com
SOUND SYSTEM
A.C. POWER
OFF
LynTec.com
Optional Key-Lock Switch
SS-2PL Sequencer Switch is a combination of
a SS-2 Switch Set with a KS-2L Locking Switch,
mounted on a single gang stainless steel wall plate.
Mechanical layout on reverse side.
LynTec
A.C. Sequencing Systems
Wire requirements
Switch set to sequencer: 4 conductors.
Between daisy chained sequencers:
9 conductors, 11 if Power Vouchers are used.
Up to 2500 ft. run: 24 ga.
2,500 to 3,750 ft. run: 22 ga.
To LynTec
PDS, MRTS, MSLC,
SLC, MSP or SP
series sequencer
COM
OFF
PILOT LED +
ON
To FIRST sequencer if daisy chained.
Rear view wiring diagram
1.25" min.
LynTec
one
SS-2 Sequencer Switch Set
Up to 5* additional remote
control locations may be
added to the system with
additional switch sets or with
other momentary switches.
139-0252-13.1 SS-2 insert 7/2/09
NC
NO
C
NC
NO
C
+ –
Rubber
anti-rotation
gasket Maximum
Panel
Thickness: .25"
See reverse side for multiple switch set wiring.
To FIRST sequencer if daisy chained.
To LAST sequencer if daisy chained.
Rock
cap
while
pulling
outward
to
remove.
idec
AL6–M
12v LED idec
AB6–M
shown
unlocked
(active)
Switch Specifications:
SPDT momentary
Contacts: 24v @0.7A
LED: 12v AC/DC@ 10ma.
Vertical mounting
Horizontal mounting
1.00"
1.00"
1.00"
1.00"
1.50"1.50"
.625" dia. hole. (5/8")
Maximum panel
thickness: .250" (1/4")
If mounted vertically, leave this much
space for easy lens cap removal.
Actual size drill templates
SS-2 Switch Set
+
optional KS-2L Locking Switch
with tumbler position label.
.750" x .640" double-D or
.750" dia. hole.
SS-2 Switch Set
ON OFF
0.710"
1.00"
0.930"
1 3
8
For SS-32 Switch Sets see
http://www.lyntec.com/139-0396_SS-32_Insert.pdf

LynTec
Model SS-2PL
Locking Swich Set.
(Optional)
When sequencers
are daisy-chained avoid using
these test switches.
Use the first ON test switch
and the last OFF test switch
to avoid confusing operation.
ON
V+ V- OFF
First
First
Last
Last
Sequencer
Board (Bottom)
Sequencer
Board (Top)
OFF
139-0202-11.2 SLC Hookup 3/30/04
See http://www.lyntec.com/139-0202_SLC_Hookup.pdf for latest version.
Blue
Red
White
Green
Blue
Red
White
Green
LynTec
Power Voucher
™
Power Voucher
™
Power Voucher
™
Multiple Sequencer Hookup Diagram
For SLC & SP LynTec Power Sequencers (no longer in production)
Showing Low-Voltage Remote ON/OFF Control
and Daisy-Chain Wiring
PILOT
LED
(green)
Parallel connect additional SS-2 switch
sets for multiple remote control locations.
4 conductors, 22 ga., 5,000 ft. max.
Maximum number of switch sets:
SLC's & SP's support 6 switch sets.
PDS-8's support 3 switch sets.
LynTec
Model PV-110
Power Verification Module
(Optional)
+–
Rear connections
NO
C
NC
NO
C
Yellow
Com Hold Borrow
One set of the
ON
and
OFF
switches shown below are supplied
unmounted as a SS-2 Switch Set with
each LynTec sequencer cabinet.
Mount in 5/8" dia. round holes in panels up
to 1/4" thick.
LynTec
8401 Melrose Drive • Lenexa, KS 66214 U.S.A.
Voice 800-724-4047 or 913-529-2233 • Fax 888-722-4157 or 913-529-4157
www.LynTec.com
C
NC
1
3
OSLO
8
Lock
switch
shown in
unlocked
position
C
Cage clamp
terminal blocks.
Press white lever
back to insert
stripped wire.
Ye l l o w
LynTec
Pilot Com CarryCom Busy
Hold Borrow Pilot Com CarryCom Busy
V+ V- OFFCom
Pilot
ON
PilotON
LynTec
Optional Power Vouchers verify all circuits
are hot and no circuit breakers are tripped.
ON light won't stay lit at end of ON
sequence if any ac circuit fails.
Test button
Test button
Install Jumper in LAST sequencer
board only if POWER VOUCHERs
are not installed.
0.625"
0.750"
1.000"
1.000"
0.625"
KS-2L
Lock
Switch
SS-2
ON
Switch
SS-2
OFF
Switch
Switch layout for field
constructed panel mounting.
1/4" max. panel thickness.
Daisy-Chain wiring:
10 conductors max.
(Worst case with multiple switch set locations and
Power Vouchers™ )
See http://www.lyntec.com/139-0252.pdf
for multi-panel daisy chain connections.
For multiple control points
add SS-2's or SS-2PL's.
Parallel connect lines.
P
P
P
P
P
P

KS-2L
Lock
Switch
SS-2
ON
Switch
SS-2
OFF
Switch
146-0231-08 3/25/05
0.625"
0.750"
0.625"
1.000"
1.000"
Switch layout for field
constructed panel mounting.
1/4" max. panel thickness.
0.640"
NOT in PDS series
See daisy-chain
connections below
for wiring between
PDS’s or multiple cabinets.
LynTec Model SS-2PL
Locking Swich Set.
(Optional)
ON
FIRST
FIRST
LAST
LAST
Sequencer
Board (Bottom)
Sequencer
Board (Top)
Parallel connect additional SS-2 switch
sets for multiple remote control locations.
4 conductors, 24 ga., 5,000 ft. loop max.
Maximum number of switch sets:
All LynTec sequencers support 6 switch sets.
+ –
connections,
rear view
NO C
NC
NO
C
One set of the
ON
and
OFF
switches shown below are supplied
unmounted as a SS-2 Switch Set with
each LynTec sequencer cabinet.
Mount in 5/8" dia. round holes in panels up
to 1/4" thick.
LynTec
Lenexa, KS (Central time zone) U.S.A.
Voice 800-724-4047 or 913-529-2233
Fax 888-722-4157 or 913-529-4157
www.LynTec.com
NC
3
OSLO
8
Lock
switch
shown in
unlocked
position
Hold Borrow Pilot Com CarryCom Busy
+5v
Logic Kill
V+ V– OFF
Com
Pilot
ON
Low voltage control wire: 24 gauge minimum, 5,000 ft. loop max.
Test button
Install Jumper in LAST sequencer
board only if POWER VOUCHERs
are not installed.
Hold Pilot Com CarryCom Busy
+5v
Logic Kill
V+ V– OFFCom
Pilot
ON
OFF
Test button
PILOT
LED
(green)
+
+
+
+
Borrow
Multiple Sequencer Hookup Diagram
For LynTec MSLC and MSP MODULAR and PDS series Power Sequencing Products
Showing Low-Voltage Remote ON/OFF Control and Daisy-Chain Wiring
For single sequencer board hookup connect OFF switch normally open to OFF.
1
See next page for enlarged daisy-chain hookup
Com
V-
OFF
Carry
Busy
Kill
Com
V-
OFF
Carry
Busy
Kill
OFF
Com
V+
V-
Com
Pilot
Borrow
ON
Hold
Kill
Com
Pilot
Borrow
ON
Hold
Kill
ON
Com
Pilot
+5v
Logic
Com
Kill
Cabinet A
Sequencer
boards 1 & 2.
Cabinet B
Sequencer
boards 3, 4 & 5.
Cabinet C
Sequencer
boards 6 & 7.
TOP
BOARD
FIRST BOTTOM
BOARD
BOTTOM
BOARD
BOTTOM
BOARD
LAST
TOP
BOARD
TOP
BOARD
C
NO
C
NO ON
OFF
Lock
C
NO
C
NO
ON
OFF Lock
Fire Alarm
N.O. contact.
Closure kills all
sequenced power.
Opening resumes
ON sequence.
Daisy-chain
connections
within a
cabinet are
made via
Cascade
Connector.
A typical three panel, daisy-chained, system with two locking control locations.
Connect
V+ to V–
on LAST
sequencer
if Power
Vouchers
are not
used.
ON
LED
+
–
ON
LED
+
–
To touch panel.
(mimics Pilot output)
1
8
3
Kill — Fire alarm shutdown
External contact closure lights the red Kill LEDs and
kills all sequenced power.
Contact opening restarts the ON sequence.
For multiple control points
add SS-2's or SS-2PL's.
Parallel connect lines.
P
OFF
Busy
Kill Carry
Com
24v
AC
V–
Hold
Com Kill
ON
Pilot
+5v CMOS Logic output.
Mimics Pilot LED.
3.3KΩsource impedance.
(For touch panel drive)
When sequencers are
daisy-chained avoid using
these test switches.
Use the first ON
ON
test switch
and the last OFF
OFF
test switch
to avoid confusing operation.
Borrow
24v
AC
N/C N/C
Cascade
Connector
(4 pin)
Power & Kill
Connector
(4 pin)
Cascade
Connector
(4 pin)
Power & Kill
Connector
(4 pin)
Cage clamp terminal blocks.
Press white levers back with
small straight-blade screwdriver
to insert stripped wires.
P
P
P
P
P
139-0252-13.2 SS-2/SS-2PL Insert 7/2/09
See http://www.lyntec.com/139-0252.pdf for latest version.
Custom switch legends you
can print on your laserprinter
See http://www.lyntec.com/139-0309_CSLF-1_Film.pdf
To isolate the Hurry-Off and Kill functions, unplug left
Power & Kill Connector and move to the left one step,
mis-mating to eliminate the board-to-board Kill connection.
These expansion terminals
on the bottom board are only used
for daisy-chain connections when
more than one cabinet is used.
These expansion terminals
on the top or middle boards are NOT used
when the cascade connectors are used to
daisy-chain boards within a cabinet.
To run each sequencer board as a separate
system, remove the right Cascade Connector.
Connect ON, Pilot, Com & OFF to switch set.
1
8
3
For SS-32 Switch Sets see
http://www.lyntec.com/139-0396_SS-32_Insert.pdf

139-0252-13.3 Daisy Chain Hookup 7/2/09
Com
V-
OFF
Carry
Busy
Kill
Com
V-
OFF
Carry
Busy
Kill
OFF
Com
V+
V-
Com
Pilot
Borrow
ON
Hold
Kill
Com
Pilot
Borrow
ON
Hold
Kill
ON
Com
Pilot
+5v
Logic
Com
Kill
Cabinet A
Sequencer
boards 1 & 2.
Cabinet B
Sequencer
boards 3, 4 & 5.
Cabinet C
Sequencer
boards 6 & 7.
TOP
BOARD
FIRST
BOTTOM
BOARD BOTTOM
BOARD
BOTTOM
BOARD
LAST
TOP
BOARD
TOP
BOARD
C
NO
C
NO ON
OFF
OFF
Lock
C
NO
C
NO
ON
OFF
OFF
Lock
Fire Alarm
N.O. contact.
Closure kills all
sequenced power.
Opening resumes
ON sequence.
Daisy-chain
connections
within a
cabinet are
made via
Cascade
Connector
jumper plug.
Connect
V+ to V–
ONLY on LAST
sequencer if
Power Vouchers
are not used.
Remove factory
installed V+ to V–
jumpers from the
bottom board of each
daisy-chained cabinet.
V+ to V–
contact-closure keeps
ON led lit at the end of
the on sequence.
ON
LED
+
–
ON
LED
+
–
To touch panel.
(mimics Pilot output)
Wire Requirements for Remote Controls
Basic system ON/OFF Control from one panel only....4 conductors
Basic + Kill Add Kill function ....................................6 conductors
2 conductors to Kill control location
Remote control at both ends ............................................9 conductors
Kill, Remote control both ends, full power verification .....11 conductors
Low voltage control wire: 24 gauge minimum, 5,000 ft. loop max.
C
N
O
ON
O
N
LED
+
–
C
C
C
N
O
ON
+
–
O
N
LED
C
1
8
3
1
8
3
For Timing Diagram and Logic levels
See http://www.lyntec.com/139-0266_Seq_Timing.pdf
A typical LynTec three panel,
daisy-chained system
with two locking control locations.

To Kill line (all connected within each
cabinet by Power & Kill jumpers) or to
all Kill lines requiring a common kill
function if not daisy-chained.
NC
What to specify or order
For ZipOff switch order ZOS-5K. (services up to 5 Kill equipped boards)
Includes switch with ZipOff film legend and flip up security cover.
Switch mounts in 5/8" round hole in panels up to 3/16" thick.
ZOS-5K Contractor C.O.D. price: $40.
Delivery: Stock.
139-0256-04.1 3/25/04
See
http://www.lyntec.com/139-0256.pdf
for latest version.
Built-in Kill, Hurry-Off and ZipOff (PANIC) switch option
for
MSLC and MSP and PDS-8EK series AC SEQUENCING SYSTEMS
What the functions do
Kill — EMERGENCY SHUTDOWN
Provides an
IMMEDIATE
shut down method for the
sound system at the command of a fire alarm,
emergency announcement system, or ZipOff switch.
Optional ZipOff switch, ZOS-5K
Provides a full AC Power shutdown within 250 milli-
seconds after the ZipOff button is pushed.
In case of a runaway oscillation or other unexpected
signal which could damage the loudspeakers if
sustained...
Lift the protective cover and press the ZipOff button...
it latches down and lights red.The AC power se-
quencing system immediately zips off.
Press again to unlatch... the light goes out and the
sequencer restarts to repower the system.
or
Use the new Hurry-Off function at any OFF switch.
Hurry-Off
The MS-12 Modular & PDS-8EK Sequencing boards
have a new Hurry-Off function. If you
hold down
any
OFF switch for two seconds, a "Kill without restore"
function is triggered.The system shuts down within 250
milliseconds and doesn't restart until you give it a new
ON command. Kinda like a DSP undo command.
How they work
All LynTec sequencing systems have the ZipOff load
shedding feature.The older SLC, SP and PDS-8's
implemented it by interrupting 24v ac power.
The newer Modular sequencers, the MSLC and MSP
series and the PDS-8EK, load shed when power fails,
but also have a Kill function that is triggered by ground-
ing the Kill line.
The red Kill LED, adjacent to the Kill terminal on the
board, lights and Zip-Off is immediate.The kill line is a
low current line. Long control wiring may be used without
concern for loop resistances up to 32Ω. (22 gauge, up to
a 1,000 ft. run [2,000 ft. loop] or a 680 ft. run of 24 ga).
The ON/OFF
latching
pilot relay remembers that the
sequencer was ON. When the Kill line is opened, the
ON sequence repeats, bringing the AC power back on.
For the Modular series control boards the ZipOff switch
connects the Kill line to common, through the Zip-Off
switch's LED, initiating the Kill function.
LynTec.com
SOUND SYSTEM
A.C. POWER
ZipOff
Push to SHUT DOWN.
Push AGAIN to restart sequence.
120-6012-03
±LED
±LED
NO
C
ZOS-5K
ZipOff
Switch
NC
NO
CPush to latch
Push to unlatch
Wiring pictorial
on reverse side
To
Common
SHUNT R(for more than 5 boards)
Normally open fire alarm
contact. Close to turnoff
all sequenced circuit
breakers (Kill).Open to
resume power-up
sequence.
For multiple ZipOff
switches connect in
parallel across Kill and
Common.
MULTI-BOARD SHUNT R
The Kill line is an 11 ma. current source from each MS-12 Modular
Sequencer or PDS-8 EK board
A voltage sensor on the Kill line determines the Kill threshold.
The Kill line has an open circuit voltage of 28 volts which must be pulled
down to less than 10.5 volts to generate a Kill function. Grounding the Kill
line to Common will always kill the system instantly.This current source may
also be used to light the Zip-Off switch's, red LED.
The red ZipOff LED only requires 10 ma. For systems where multiple-board
system's Kill lines are paralleled, a 9 v.voltage regulator chip is installed in
the ZOS-5K which will automatically shunt the excess source current of up
to 5 boards. For more than 5 boards an additional resistor must be used in
parallel with the ZipOff switch LED.To prevent damage due to overheating
the voltage regulator chip, the resistor should be installed as shown with
full
length leads
to get the heat source away from the switch.
Total Number Shunt Resistor
of boards required
1-5........................ none
6 .................... 820Ω, 1/4w
7 .................... 430Ω, 1/4w
8 .................... 270Ω, 1/2w
9 .................... 200Ω, 1/2w
10 ................... 150Ω, 1/2w
11 .................... 150Ω, 1w
12 .................... 120Ω, 1w
13 .................... 100Ω, 1w
14 ..................... 92Ω, 1w
15 ..................... 82Ω, 1w
16............... 75Ω, 2w
17............... 68Ω, 2w
18............... 62Ω, 2w
19............... 56Ω, 2w
20............... 56Ω, 2w
21............... 51Ω, 2w
22............... 47Ω, 2w
23............... 47Ω, 2w
24............... 43Ω, 2w
25............... 39Ω, 2w
9v voltage
regulator
☛
www.LynTec.com
8401 Melrose Drive • Lenexa, KS 66214 • Voice 800-724-4047 or 913-529-2233 • Fax 888-722-4157 or 913-529-4157

ON
LynTec.com
OFF
0.930"
0.710"
1.000"
NC
NO
C
NC
NO
C
+–
ONOFF
COM
OFF
PILOT LED +
ON
To FIRST sequencer if daisy chained.
.625" dia. hole. (5/8")
Maximum panel thickness: .188" (3/16")
139-0256-04.2 3/25/04
Wiring pictorial - Rear view
idec
AL6–M
idec
AB6–M
Wire requirements
Switch set to sequencer: 4 conductors.
Between daisy chained Modular sequencers:
9 conductors, 11 if Power Vouchers are used.
Up to 5,000 ft run: 22 ga.,
5,000 to 7500 ft. run: 20 ga.
7,500 to 10,000 ft. run: 18 ga.
See other side for ZipOff wire sizing.
Optional Key-Lock Switch
(see SS-2PL Sequencer Switch
with Locking Switch on single gang
stainless steel wall plate)
12v LED
Rubber
anti-rotation
gasket
Press to SHUT DOWN.
Push AGAIN to restart sequence.
1.000"
0.930"
1.171"
NC
NO
C
+–
ZipOff
Flip-up
security
cover
To PDS-8 EK series or
MSLC, MSP series sequencer
GREEN
lit when
ON
RED
lit when
Zipped Off
RED
not illuminated
LynTec.com
LynTec.com
FLASHES DURING SEQUENCING
ON
LynTec.com
OFF Press to SHUT DOWN.
Push AGAIN to restart sequence.
LynTec.com
LynTec.com
To FIRST sequencer if daisy chained.
To LAST sequencer if daisy chained.
To Kill on Modular or PDS-8EK
sequencer board.
See other side for wire sizing
requirements.
(Max. loop resistance: 32).
LynTec
for Modular A.C. Sequencing Systems, models MSLC, MSP & PDS-8EK.
ON, OFF and ZipOff switch mounting & wiring
SS-2
Switch Set
1 set supplied with
each sequencing
system.
Optional
ZOS-5K
ZipOff Switch
includes flip-up security cover
ZipOff
ZipOff
Film
Legends
For older PDS-8E series or
SLC, SP series sequencers
see
http://www.lyntec.com/139-0137_ZOS-1.pdf
SHUNT R
LynTec
ZOS-5K
146-0259-00
SOUND SYSTEM
A.C. POWER
SOUND SYSTEM
A.C. POWER
SOUND SYSTEM
A.C. POWER
SOUND SYSTEM
A.C. POWER SOUND SYSTEM
A.C. POWER SOUND SYSTEM
A.C. POWER
FLASHES DURING SEQUENCING
Voltage regulator
chip for 1 to 5
sequencer boards.
SHUNT Resistor
required for more than 5
sequencer boards.
See reverse side.
Leave full leads on resistor
to keep heat away from
switch body.
Voltage regulator
chip for 1 to 5
sequencer boards.
Table of contents
Popular Switch manuals by other brands

Comtech EF Data
Comtech EF Data CRS-170A Installation and operation manual

Planet
Planet GSD-800S datasheet

Aube Technologies
Aube Technologies TI035 user manual

Avaya
Avaya 3500 series Getting started

Datacom
Datacom DM4270 installation guide

Extreme Networks
Extreme Networks Summit WM100 installation instructions