LYSON W5014 User manual

The following manual encompasses the devices bearing the following codes:
W5014
Manual
1. The general safety principles for device operation
1.1. Operational principles
1.2. Electrical safety
1.3. Operational safety
2. Characteristics of the device
2.1. Device description
2.2. Controller handling
2.3. Error codes
2.4. Device technical parameters
3. Device storage
4. Maintenance and cleaning
5. Recycling
6. Guarantee

1. GENERAL SAFETY PRINCIPLES FOR
DEVICE OPERATION
Prior to device usage initiation, refer to the following
manual and act according the guidelines contained
therein. The manufacturer shall not be held
accountable for any damages caused by improper
usage of the device or its improper handling
.
1.1. Operational principles
1. The incubator is intended for raising queen bees.
2. Prior to the first usage, the Incubator shall be
washed and located in the place of operation.
1.2. Electrical safety
1. Power supply electric installation must be
equipped with RCD with nominal tripping current In
below 30 mA. Functioning of overcurrent circuit
breaker must be checked periodically.
2. Check the nominal voltage of the device and the
power source for compliance.
3. If the power supply cable gets damaged and it
must be replaced, this will be performed by a
guarantor or a specialist service centre or a qualified
person in order to avoid any danger. Do not use the
incubator when the power supply cable or a
connecting cable are damaged!
4. Prior to connecting the device to the mains, make
sure that the controller is off. The switch on the
controlling panel (A –fig. 2) should be in “0” position.
5. While connecting to the mains, be careful. Hands
must be dry! The floor on which the device is placed
must be dry too!
6. Do not displace the incubator while in operation.
7. Protect the controller against humidity (also during
the storage).
8. It is forbidden to pull the power supply cable. The
power supply cable must be kept away from any heat
sources, sharp edges and its proper state must be
secured.
1.3. Operational safety
1. The following equipment is not intended to be used
by persons with limited physical, sensory or mental
capabilities (including children) or persons
inexperienced or unfamiliar with that type of
equipment unless the usage occurs undersupervision
or in line with the equipment operating manual
provided by safety supervising persons. Make sure
that children do not play with the incubator
2. In case of any damage t the incubator, in order to
avoid any danger the repair must be performed by a
qualified person or a specialist service centre only.
3. It is forbidden to perform any maintenance works
or repairs while the device is connected to the mains!.
4. The device must not be stored nor switched on at
the temperature below 0º C. The incubator must not
be activated with the ambient temperature below 5ºC
5. Prior to the incubator activation, in case when it
has been transported from a room with a lower
temperature to a room with a higher temperature,
wait until the device has reached the ambient
temperature.
It is forbidden to make repair when the device is in
operation
It is forbidden to remove the shields while the device
is in operation.
2. Device characteristics
The Incubator has been equipped with an advanced
IC-01 controller which supervises the internal
temperature and humidity. It controls the air flow,
filling an internal tank with water. It is made of
stainless steel with insulated walls.
2.1 Device description
Figure 1
A B C D E F G

Description of the incubator:
A- distilled water tank - 4L.
B-water level indicator
C-air holes
D-controller
E-incubator chamber
F-transparent door to control the raising process
G-incubator door
Figure 2
A B C D E
Description of the controller:
A-main switch 0-1
B-controlling panel
C-power supply cable
D-5A fuse holder
E-Bluetooth communication outlet
2.2 Handing the controller
ŁYSOŃ IC-0x 0.1
. . . . . . .
2 3 4 5
1
ELEMENT
DESCRIPTION
1 –display
After activation –displays
sequentially: manufacturer’s name,
device type and software version
1. Main screen –basic screen
selected by default once the device
has been activated. Screen
description below.
2. The screen to set the setpoint
temperature –the displays shows
the temperature measured (upper
line) and the setpoint temperature
(lower line).
3. The screen to set the setpoint
humidity –the display shows the
humidity measured (upper line) and
the setpoint humidity (lower line).
4. The screen for operating
statistics –the displays shows the
minimal and maximum values of
temperature and humidity registered
(since the control supply activation).
Reset of the values registered shall
occur after pressing the „plus” or
„minus” buttons
5. Service screen for TH sensor
temperature readouts calibration
–the display shows the temperature
measured including the calibration
(upper line) and the calibration
value (lower line)
6. Service screen for humidity
readouts calibration –the display
shows the humidity measured
including the calibration (upper
line) and the calibration value
(lower line)
7. Service screen for temperature
regulator tuning –the display
shows the value of Kp parameter –
tuning of the temperature regulator.
In case when the setpoint
temperature has not been achieved
or when reaching the temperature
lasts too long, the value of the
parameter must be increased.
Respectively, when there are

noticeable temperature over-
regulations, the parameter shall be
lowered.
8. Service screen for the
calibration of T1 additional
sensor temperature readouts. The
display shows the temperature
measured including the calibration
(upper line) and the calibration
value (lower line)
2 –“-“ button for
value lowering
Main screen (1) –pressing the
button will switch off the lighting of
the incubator chamber.
Statistics screen (4) –pressing the
button will reset the statistics for the
measurements of the temperature
and humidity.
Other screens –pressing the button
will decrease the value of the
modified parameter.
3 –„+„ button
for value
increasing
Main screen (1) –pressing the
button will switch on the lighting of
the incubator chamber.
Statistics screen (4) –pressing the
button will reset the statistics for the
measurements of the temperature
and humidity.
Other screens –pressing the button
will increase the value of the
modified parameter.
4 –button „<>”
screen switching
Pressing the button shortly will
switch between the controller
screens.
5 –button
„ON/OFF”
Pressing the button alternately for a
short time will activate (ON) and
deactivate (OFF) the climate
controlling inside the incubator.
In the deactivated state (OFF), the
regulator acts as a typical
hytherograph completed by the
registration system for min and max
values. Additionally, in the
deactivated state it is possible to
switch on and off the cabin lighting,
switch between the screens, reset
the operating statistics and to
modify the parameters displayed.
In the activated state (ON), apart
from all the operations typical for
OFF state, the controller
additionally :
•based on the TH sensor
readout, maintains the
setpoint temperature by
regulating the power
supply to the main heater.
•based on the TH sensor
readout, maintains the
setpoint humidity
•based on the T1 sensor
readout, maintains the
setpoint temperature by
regulating the power
supply to an additional
heater
•regulates the water level
inside the humidifier
system
•detects and signals
emergency and warning
states
26.5 C
43%
T D W
1 2 3 4
6 8 9 10
7
5
ELEMENT
DESCRIPTIONS
1 –temperature
indication
The field shows the value of the
temperature measured.
2 –signalling of
T1 sensor damage
Displayed sign together with a
periodical sound signal indicate
the damage to an additional sensor
(T1). Switching off the controller
resets the failure signalling.
3 –signalling of
open door
Displayed sign together with a
periodical sound signal indicate
timeout of door opening. Closing
the door resets the signal
4 –signalling a
failure in the
water filling
system of a
humidifier
Displayed sign together with a
periodical sound signal indicate
the timeout for water filling in a
humidifier. The signal may be
triggered by:
•water shortage
•damage/suspension of a
float switch

•damage to a solenoid
valve that controls the
filling
•stopping the liquid flow
from a tank to a
humidifier
Defect signalling is accompanied
by cutting off the power supply to
the humidifier heater. Switching
off the controller resets the failure
signalling.
5 –signalling the
activation of cli
mate controlling
inside the
incubator
Displayed sign signals
deactivation of temperature and
humidity controlling inside the
incubator (incubator operation
deactivating)
6 –humidity
indication
The field indicates the value of the
humidity measured. In case of
humidity sensor failure, the sign „-
„ is displayed as the value readout.
Failure signal is accompanied by a
periodical sound signal.
7 –signalling of
activating for a
solenoid valve of
humidifier water
filling
The displayed sign indicates the
activating of a solenoid valve that
fills in the water tank of air
humidifier.
8 –signalling the
activation of the
incubator
chamber lighting
The displayed sign signals
switching on the incubator
chamber lighting.
9 –signalling the
activation of the
air humidifier
system.
The displayed sign signals the
activation of air humidifier inside
the incubator chamber.
10 –signalling
the activation of
the air humidifier
activation.
The displayed sign signals energy
supply to the temperature main
heater inside the incubator
chamber
.
2.3 Error codes
ERROR
ERROR DESCRIPTION
100
Internal failure of the controlling computer.
200
Damaged or blocked “-“ button .
201
Damaged or blocked “+” button.
202
Damaged or blocked „<>„ button - 4.
203
Damaged or blocked „ON/OFF„ button.
300
Damaged sensor of temperature
measurement for TH composite sensor.
301
Temperature indication of TH composite
sensor outsider the permissible range.
302
Temperature regulation error –damaged
heaters power supply path.
2.4 Device technical parameters
-power supply 230V/5A
-capacity 300 queen bee’s cells
-external dimension: width. x depth. x height.-
900x500x750mm.
-shelf dimension: width. x depth. x height. –
560x370x130mm.
-power consumption 480W
-advanced IC-01 controller
-LED lighting for the incubator chamber
-4 l tank for distilled water
The recommended air temperature in the
room where the incubator works should be
20-30°C.
3. Device storage
After termination of operation, the device must
be washed and dried thoroughly
Prior to the incubator’s start-up. in case when it
has been transferred from a room with a lower
ambient temperature to a room with a higher
one . one must wait until the device has reached
the ambient temperature.
The device is to be stored in dry rooms with the
temperature above 0º C.
The incubator must not be switched on with the
ambient temperature below 5 degrees C.
Before every season. an additional technical
inspection must be performed and in case when
any defects have been detected, a service
centre must be contacted
4. Maintenance and cleaning
Prior to the maintenance, unplug from the mains!
While washing, be careful not to damp the controller
(it can be covered with a water-resistant material).
While washing take precautions not to damp the
internal heating elements. Dry the incubator carefully
after washing.
Before every season. an additional technical
inspection must be performed and in case when any
defects have been detected, a service centre must
be contacted

5. Recycling
Worn-out product must be removed as waste only
within selective waste collection organised by the
Network of Communal Electric and Electronic Waste
Collecting Points. A customer is entitled to return the
used equipment to the electrical equipment distributor
network. at least free of charge and directly. if the
device to be returned is of proper type and serves the
same purpose as the newly purchased device
6. Guarantee
Product purchased from “Łysoń’ company are
encompassed by the manufacturer’s guarantee.
The guarantee duration equals 2 years .
A receipt or a VAT invoice is issued for each product
purchased.
Details on the guarantee terms available
on www.lyson.com.pl