M-system M5SN User manual

MODEL: M5SN
Super-mini Terminal Block Signal Conditioners M5-UNIT
INPUT LOOP POWERED ISOLATOR
Functions & Features
• Input-loop-powered design eliminates need for an output
loop power supply
• 350 Ω output drive
• High-density mounting
• CE marking
25 (.98)
97
(3.82)
41 (1.61)
mm (inch)
MODEL: M5SN-AA[1]
ORDERING INFORMATION
Specify a code from below for [1]
• Code number: M5SN-AA[1]
(e.g. M5SN-AA/Q)
• Specify the specification for option code /Q
(e.g. /C01 )
INPUT
Current
A: 4 – 20 mA DC
OUTPUT
Current
A: 4 – 20 mA DC
[1] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
GENERAL SPECIFICATIONS
Construction: Terminal block
Connection: M3.5 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (black)
Isolation: Input to output
Zero adjustment: -0.5 to +0.5 % (front)
Span adjustment: 98.5 to 101.5 % (front)
INPUT & OUTPUT
• Input 4 – 20 mA DC / Output 4 – 20 mA DC
Equivalent input impedance: 230 Ω plus load resistance
with 20 mA input
Operational range: 3 – 22 mA DC
(Accuracy is assured within 4 – 22 mA)
Load resistance: 350 Ω maximum; min. 50 Ω required for
adequate operation
INPUT CURRENT [mA]
4 12 20
10.0
VOLTAGE [V] ACROSS
INPUT TERMINALS
3.0
approx. 5.6
(load 50Ω)
6.0
12.0
approx. 5.0
8.0
approx. 3.8
approx. 9.6
(load 250Ω)
approx. 4.6
approx. 11.6
(load 350Ω)
INSTALLATION
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 0 to 90 %RH (non-condensing)
Mounting: DIN rail
Weight: 80 g (2.8 oz)
PERFORMANCE in percentage of span
Accuracy: ±0.1 %
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
Response time: Approx. 15 msec. (0 – 90 %)
Load effect: (factory-calibrated with 250 Ω load)
0.015 %/Ω (50 – 150 Ω)
0.003 %/Ω (150 – 350 Ω)
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength:
500 V AC @1 minute (input to output)
2000 V AC @1 minute (input or output to ground)
STANDARDS & APPROVALS
CE conformity:
EMC Directive (2004/108/EC)
EMI EN 61000-6-4: 2007
EMS EN 61000-6-2: 2005
Rugghölzli 2
CH - 5453 Busslingen Tel.+41 (0)56 222 38 18
Fax +41 (0)56 222 10 12 mailbox@sentronic.com
www.sentronic.com
Produkte, Support und Service
SENTRONICAG
MODEL: M5SN
DIMENSIONS unit: mm (inch)
94 (3.70)3 (.12)
25 (.98) 41 (1.61) [3.3 (.13)]
• When mounting, no extra space is needed between units.
DIN RAIL
35mm wide
8–M3.5 SCREW
7.3 (.29)
35.4 (1.39)
1 2
3 4
5 6
7 8
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
+
–
INPUT
3+
–
5
6
7
8
4
1
2
S
OUTPUT
Inverter
Isolation
Load Effect
Compensation
Z
Specifications are subject to change without notice.
Rugghölzli 2
CH - 5453 Busslingen Tel.+41 (0)56 222 38 18
Fax +41 (0)56 222 10 12 mailbox@sentronic.com
www.sentronic.com
Produkte, Support und Service
SENTRONICAG
M5SN
P. 1 / 2EM-2469 Rev.3
INPUT LOOP POWERED ISOLATOR MODEL M5SN
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■ PACKAGE INCLUDES:
Signal conditioner......................................................... (1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the input
signal for safety.
■ ENVIRONMENT
• Indoor use
•When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ven-
tilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 0 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
•Do not install cables (input and output) close to noise
sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
• Install lightning surge protectors for those wires connect-
ed to remote locations. Choose a surge protector with its
maximum surge voltage 40V or less between lines. Rec-
ommended M-System model: MDP-24-1.
■ AND ....
•The unit is designed to function as soon as the input sig-
nal is supplied, however, a warm up for 10 minutes is re-
quired for satisfying complete performance described in
the data sheet.
COMPONENT IDENTIFICATION
INSTALLATION
Set the unit so that its DIN rail adapter is at the bottom.
■ MOUNTING THE UNIT ON A DIN RAIL
A) Hang the upper hook at the rear side of unit on the DIN
rail.
B) Push in the lower in keeping pressing the unit to the
DIN rail.
■ REMOVING THE UNIT
A) Push down the DIN rail adaptor using a minus screw-
driver.
B) Pull out the lower part of the unit.
C) Remove the upper part from the DIN rail.
Terminal Cover
Zero Adj.
Span Adj.
Body
Spec. Marking
A
B
DIN Rail
A
C
B
Spring Loaded
DIN Rail Adaptor
Rugghölzli 2
CH - 5453 Busslingen Tel.+41 (0)56 222 38 18
Fax +41 (0)56 222 10 12 mailbox@sentronic.com
www.sentronic.com
Produkte, Support und Service
SENTRONICAG
M5SN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the con-
nection diagram on the front of the unit.
■ EXTERNAL DIMENSIONS unit: mm (inch)
■ CONNECTION DIAGRAM
94 (3.70)3 (.12)
25 (.98) 41 (1.61) [3.3 (.13)]
• When mounting, no extra space is needed between units.
35.4 (1.39)
DIN RAIL
35mm wide
8–M3.5 SCREW
7.3 (.29)
1 2
3 4
5 6
7 8
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Input: Check current with an ammeter. Be sure that
the connected transmitter allows the M5SN’s load value
[230Ω + output load resistance].
3) Output: Check that output load is within the permis-
sible limit of 50 to 350Ω.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■ HOW TO CALIBRATE THE OUTPUT SIGNAL
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the input signal on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
MAINTENANCE
Regular calibration procedure is explained below:
■ CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
+
–
INPUT 3+
–
5
6
4OUTPUT
Rugghölzli 2
CH - 5453 Busslingen Tel.+41 (0)56 222 38 18
Fax +41 (0)56 222 10 12 mailbox@sentronic.com
www.sentronic.com
Produkte, Support und Service
SENTRONICAG

Other M-system I/O System manuals

M-system R30US4 User manual

M-system

M-system R30US4 User manual

M-system R3-SV4 User manual

M-system

M-system R3-SV4 User manual

M-system R7D-RS4 User manual

M-system

M-system R7D-RS4 User manual

M-system R3-SV16N User manual

M-system

M-system R3-SV16N User manual

M-system R7F4DC-DAC16D-H User manual

M-system

M-system R7F4DC-DAC16D-H User manual

M-system R7E-EC16B User manual

M-system

M-system R7E-EC16B User manual

M-system R30SVF4 User manual

M-system

M-system R30SVF4 User manual

M-system R7ML-LC2-R User manual

M-system

M-system R7ML-LC2-R User manual

M-system R30PA2 User manual

M-system

M-system R30PA2 User manual

M-system 60C User manual

M-system

M-system 60C User manual

M-system R3-DC64A User manual

M-system

M-system R3-DC64A User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R7ML-SV4 User manual

M-system

M-system R7ML-SV4 User manual

M-system M8BS2-041 User manual

M-system

M-system M8BS2-041 User manual

M-system R7G4HML-6-SVF8N User manual

M-system

M-system R7G4HML-6-SVF8N User manual

M-system M8BS2-042 User manual

M-system

M-system M8BS2-042 User manual

M-system Mini-MW Series User manual

M-system

M-system Mini-MW Series User manual

M-system R7L-TS4 User manual

M-system

M-system R7L-TS4 User manual

M-system R3-RS8B User manual

M-system

M-system R3-RS8B User manual

M-system R3-SV4A User manual

M-system

M-system R3-SV4A User manual

M-system R7C-DA16 User manual

M-system

M-system R7C-DA16 User manual

M-system R3-DA64A User manual

M-system

M-system R3-DA64A User manual

M-system R8 Series User manual

M-system

M-system R8 Series User manual

M-system R7D-PA8 User manual

M-system

M-system R7D-PA8 User manual

Popular I/O System manuals by other brands

ST STM32F103x6 manual

ST

ST STM32F103x6 manual

Leviton A8332 Installation and operation manual

Leviton

Leviton A8332 Installation and operation manual

GHM HONSBERG OMNIPLUS-RRI HONSBERG OMNIPLUS-RRH operating instructions

GHM

GHM HONSBERG OMNIPLUS-RRI HONSBERG OMNIPLUS-RRH operating instructions

Siemens SIMATIC ET 200SP manual

Siemens

Siemens SIMATIC ET 200SP manual

Kieback&Peter FBU410 quick start guide

Kieback&Peter

Kieback&Peter FBU410 quick start guide

Sferalabs IAMU21X user guide

Sferalabs

Sferalabs IAMU21X user guide

Contec RRY-16C(PCI)H user guide

Contec

Contec RRY-16C(PCI)H user guide

Contec CONPROSYS nano CPSN-COM-1PD Reference manual

Contec

Contec CONPROSYS nano CPSN-COM-1PD Reference manual

AutomationDirect Productivity2000 P2-08AD-1 manual

AutomationDirect

AutomationDirect Productivity2000 P2-08AD-1 manual

Contec AI-1204Z-PCI user guide

Contec

Contec AI-1204Z-PCI user guide

Contec CPS-MC341-DS2-111 Reference manual

Contec

Contec CPS-MC341-DS2-111 Reference manual

Control Technologies 2556-A Installation and operation guide

Control Technologies

Control Technologies 2556-A Installation and operation guide

Contec CCU-78F/25M quick start guide

Contec

Contec CCU-78F/25M quick start guide

SIGMA TEK AI 088-1 instruction manual

SIGMA TEK

SIGMA TEK AI 088-1 instruction manual

Contec PIO-16/16L(PC)V quick start guide

Contec

Contec PIO-16/16L(PC)V quick start guide

Contec DIO-3232L-PE user guide

Contec

Contec DIO-3232L-PE user guide

BlueChip AIP-8d user manual

BlueChip

BlueChip AIP-8d user manual

Contec COM-2(PC)F user guide

Contec

Contec COM-2(PC)F user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.