manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. I/O System
  8. •
  9. M-system R3-TS4 User manual

M-system R3-TS4 User manual

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8362 Rev.5 P. 1 / 4
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Thermocouple input module (body + 4 CJC sensors)........(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■HOT SWAPPABLE MODULES
• Replacing the module does not affect other modules on
the same base. Thus, the module can be replaced while
the power is ON. However, replacing multiple modules
at once may greatly change live voltage levels. We highly
recommend to replace them one by one.
■GENERAL PRECAUTIONS
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
THERMOCOUPLE INPUT MODULE
(4 points, isolated) MODEL R3-TS4
R3-TS4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8362 Rev.5 P. 2 / 4
COMPONENT IDENTIFICATION
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
ON
8
7
6
5
4
3
2
1
SW1SW2
ON
8
7
6
5
4
3
2
1
SW3
ON
4
3
2
1
■FRONT VIEW ■SIDE VIEW
ERR LED
RUN LED
Conv.
Rate
Temp.
Unit
Input 2 (SW1)
or
Input 4 (SW2)
T/C
Input 1 (SW1)
or
Input 3 (SW2)
Burnout
Functions
■STATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with burnout;
Green in normal operating conditions.
■SIDE DIP SW
(*) Factory setting
• Thermocouple Type: SW1, SW2
INPUT 1 (SW1) INPUT 2 (SW1)
T/CINPUT 3 (SW2) INPUT 4 (SW2)
12345678
OFF OFF OFF OFF OFF OFF OFF OFF
K (CA) (*)
ON
OFF OFF OFF
ON
OFF OFF OFF
E (CRC)
OFF
ON
OFF OFF OFF
ON
OFF OFF
J (IC)
ON ON
OFF OFF
ON ON
OFF OFF
T (CC)
OFF OFF
ON
OFF OFF OFF
ON
OFF
B (RH)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
R
OFF
ON ON
OFF OFF
ON ON
OFF
S
ON ON ON
OFF
ON ON ON
OFF
C (WRe 5-26)
OFF OFF OFF
ON
OFF OFF OFF
ON N
ON
OFF OFF
ON ON
OFF OFF
ON U
OFF
ON
OFF
ON
OFF
ON
OFF
ON L
ON ON
OFF
ON ON ON
OFF
ON P (Platinel II)
OFF OFF
ON ON
OFF OFF
ON ON (PR)
• Burnout: SW3-1
SW3-1 BURNOUT
OFF Upscale (*)
ON Downscale
• Temperature Unit: SW3-2, 3-3
SW3-2 SW3-3 TEMP. UNIT
OFF OFF °C (*)
ON OFF °F
OFF ON K (Absolute Temp)
• Conversion Rate: SW3-4
SW3-4 CONV. RATE
OFF 250 msec. (*)
ON 1 sec.
R3-TS4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8362 Rev.5 P. 3 / 4
PC CONFIGURATOR
With configurator software, settings shown below are available.
Refer to the software manual of R3CON for detailed operation.
■CHANNEL INDIVIDUAL SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Zero Scale -32000 to +32000 0
Full Scale -32000 to +32000 10000
Zero Adjust -320.00 to +320.00 0.00
Full Adjust -32000 to +32000 1.0000
Zero Base Depends on sensor type 0.00
Full Base Depends on sensor type 0.00
Unused 0: Enable
1: Disable
0: Enable
■CHANNEL BATCH SETTING
PARAMETER AVAILABLE RANGE DEFAULT SETTING
Limit (V0.10 or higher) No check mark: Limits to the scaling values equivalent
to -15 % to +115 %.
Check-marked: Limits within Zero Scale to Full Scale.
No check mark
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
1
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
130 (5.12)
27.5 (1.08) 109 (4.29) POSITIONING
GUIDE
TERMINAL
COVER
20–M3
SCREW
6.2
(.24)
R3-TS4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-8362 Rev.5 P. 4 / 4
■CONNECTION DIAGRAM
*For dual redundant communication.
+
–
T/C
comp. wire
1
2
12
+
–
INPUT 1
CJC
SENSOR
+
–
T/C
comp. wire
3
4
14
+
–
INPUT 2
CJC
SENSOR
+
–
T/C
comp. wire
6
7
17
+
–
INPUT 3
CJC
SENSOR
+
–
T/C
comp. wire
8
9
19
+
–
INPUT 4
CJC
SENSOR
BUS CONNECTOR
INTERNAL POWER
INTERNAL BUS A
INTERNAL BUS B*
• Unused Input Channels
(Choose K (CA) thermocouple for unused channels.)
Unused channels left open are equal to the burnout, which
turns the red ERR LED on and sets a burnout ag at the
PLC or the host device.
Unused channels can be specied and set so on the
PC
Congurator Software (model: R3CON) without needing to
short at the eld terminals.
1
2
INPUT 1
3
4
INPUT 2
6
7
INPUT 3
8
9
INPUT 4
12 14 17 19
CJC
SENSOR
Short
Close across the unused input terminals as shown below.
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.3 – 0.75 mm2
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd., Nichifu Co., Ltd.
12max
6max
3max 4min
3.2 dia.
(mm)

Other M-system I/O System manuals

M-system R7D-YS2A User manual

M-system

M-system R7D-YS2A User manual

M-system M8BS2-041 User manual

M-system

M-system M8BS2-041 User manual

M-system R7ML-RS4 User manual

M-system

M-system R7ML-RS4 User manual

M-system R3-PC16A User manual

M-system

M-system R3-PC16A User manual

M-system R30SVF4 User manual

M-system

M-system R30SVF4 User manual

M-system R8-SS4N User manual

M-system

M-system R8-SS4N User manual

M-system R3-SV4C User manual

M-system

M-system R3-SV4C User manual

M-system R7F4HEIP-DAC16C User manual

M-system

M-system R7F4HEIP-DAC16C User manual

M-system Devicenet R7F4DD-DAC16C-C User manual

M-system

M-system Devicenet R7F4DD-DAC16C-C User manual

M-system R7C-EA16 User manual

M-system

M-system R7C-EA16 User manual

M-system R3-SV8N User manual

M-system

M-system R3-SV8N User manual

M-system R7ML-SV4 User manual

M-system

M-system R7ML-SV4 User manual

M-system R3-RS4 User manual

M-system

M-system R3-RS4 User manual

M-system R7E-PA8 User manual

M-system

M-system R7E-PA8 User manual

M-system R7E-PA8 User manual

M-system

M-system R7E-PA8 User manual

M-system R7C-EC16B User manual

M-system

M-system R7C-EC16B User manual

M-system R5T-PA2 User manual

M-system

M-system R5T-PA2 User manual

M-system R3-TS8 User manual

M-system

M-system R3-TS8 User manual

M-system R7HL-PA4E User manual

M-system

M-system R7HL-PA4E User manual

M-system R7F4DC-DA16A-J User manual

M-system

M-system R7F4DC-DA16A-J User manual

M-system M5SN User manual

M-system

M-system M5SN User manual

M-system R7I4DML3-DC32A User manual

M-system

M-system R7I4DML3-DC32A User manual

M-system R3Y-RS8 User manual

M-system

M-system R3Y-RS8 User manual

M-system R3S-RS4A User manual

M-system

M-system R3S-RS4A User manual

Popular I/O System manuals by other brands

Nittan NAM-AS3 Installation & technical manual

Nittan

Nittan NAM-AS3 Installation & technical manual

Mitsubishi Electric NZ2GF2S-60MD4 user manual

Mitsubishi Electric

Mitsubishi Electric NZ2GF2S-60MD4 user manual

Bosch Rexroth Inline Series Configuring and Installing

Bosch

Bosch Rexroth Inline Series Configuring and Installing

GMI TBE-D5001-TRI Series instruction manual

GMI

GMI TBE-D5001-TRI Series instruction manual

Moxa Technologies ioLogik E1261H user manual

Moxa Technologies

Moxa Technologies ioLogik E1261H user manual

Omron CQM1 Operation manual

Omron

Omron CQM1 Operation manual

National Instruments PXIe-4480 Getting started guide

National Instruments

National Instruments PXIe-4480 Getting started guide

Pickering 40-412 user manual

Pickering

Pickering 40-412 user manual

National Instruments USB-9265 USER GUIDE AND SPECIFICATIONS

National Instruments

National Instruments USB-9265 USER GUIDE AND SPECIFICATIONS

Mitsubishi FX2N-4AD-TC user guide

Mitsubishi

Mitsubishi FX2N-4AD-TC user guide

Emerson 3AODO8 Field installation guide

Emerson

Emerson 3AODO8 Field installation guide

Digital Equipment pdp11 RSX-11M Reference manual

Digital Equipment

Digital Equipment pdp11 RSX-11M Reference manual

Advantech USB-4751 user manual

Advantech

Advantech USB-4751 user manual

Phoenix Contact IB IL SYS PRO UM E user manual

Phoenix Contact

Phoenix Contact IB IL SYS PRO UM E user manual

National Instruments SCC-PWR01 user guide

National Instruments

National Instruments SCC-PWR01 user guide

Motorola MOSCAD-M RTU Hardware manual

Motorola

Motorola MOSCAD-M RTU Hardware manual

ABB Remote I/O RIO600 Installation and commissioning manual

ABB

ABB Remote I/O RIO600 Installation and commissioning manual

WAGO I/O SYSTEM 750 manual

WAGO

WAGO I/O SYSTEM 750 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.