manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Rack & Stand
  8. •
  9. M-system 17BXE-U1 User manual

M-system 17BXE-U1 User manual

Other M-system Rack & Stand manuals

M-system 18KBXH User manual

M-system

M-system 18KBXH User manual

M-system BX-16G-1 User manual

M-system

M-system BX-16G-1 User manual

M-system 18KBXW-Y2 User manual

M-system

M-system 18KBXW-Y2 User manual

M-system MB User manual

M-system

M-system MB User manual

M-system M8BS-4U0 User manual

M-system

M-system M8BS-4U0 User manual

Popular Rack & Stand manuals by other brands

Dynex DX-MP3MT Quick setup guide

Dynex

Dynex DX-MP3MT Quick setup guide

Konig & Meyer 24185 manual

Konig & Meyer

Konig & Meyer 24185 manual

ECG LD 326501 instruction manual

ECG

ECG LD 326501 instruction manual

Philips SB7S19S/00 quick start guide

Philips

Philips SB7S19S/00 quick start guide

Woodline KIT-250 lb instructions

Woodline

Woodline KIT-250 lb instructions

ricoo S1222 installation instructions

ricoo

ricoo S1222 installation instructions

Kanto P301 user manual

Kanto

Kanto P301 user manual

VidaBox VB MNT FFS2 installation guide

VidaBox

VidaBox VB MNT FFS2 installation guide

PROEL PLWIN60C user manual

PROEL

PROEL PLWIN60C user manual

AllMounts PLB-43S instruction manual

AllMounts

AllMounts PLB-43S instruction manual

VMP VH-001 instruction sheet

VMP

VMP VH-001 instruction sheet

Nederman SYSTEM 920/400 instruction manual

Nederman

Nederman SYSTEM 920/400 instruction manual

Glasdon ORBIS POST MOUNTING KIT installation guide

Glasdon

Glasdon ORBIS POST MOUNTING KIT installation guide

Songmics LGR105 manual

Songmics

Songmics LGR105 manual

Grape GM401 user manual

Grape

Grape GM401 user manual

FourStarGroup 11225296 manual

FourStarGroup

FourStarGroup 11225296 manual

CHIEF FLR100 installation instructions

CHIEF

CHIEF FLR100 installation instructions

FEC XDCAM EX PMW-EX30 manual

FEC

FEC XDCAM EX PMW-EX30 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Standard rack......................................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
85 – 132V AC rating: 85 – 132V, 47 – 63 Hz, approx. 100VA
170 – 264V AC rating: 170 – 264V, 47 – 63 Hz, approx. 100VA
24V DC rating: 24V ±10%, approx. 70W
110V DC rating: 85 – 150V, approx. 70W
■GENERAL PRECAUTIONS
• Before you remove the unit from the rack or mount it,
turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the rack inside proper housing and ventilate it.
• Do not install the rack where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
or 23 to 131°F (0 to 50°C or 32 to 122°F for AC power)
with relative humidity within 40 to 85% RH in order to
ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Specifications
(side)
Body
MOUNTING REQUIREMENTS unit: mm (inch)
101.6
(4.00)
*
450 (17.72)
465 (18.31)
4–M5 SCREW ANGLE BRACKET
Observe an appropriate wiring space below.
*
100 (3.94)
for JIS standard
STANDARD RACK
(with Fujitsu FCN type I/O connector) MODEL 17BXE-U1
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2906-A Rev.2 P. 1 / 3
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
153 (6.02)33 (1.30)
2 (.08)
435 (17.13)
● RACK (standard)
*Not provided for 24V DC power.
1 3 1521416
186 (7.32)
● SURFACE (option /W)
465 (18.31)
180 (7.09)
101.6 (4.00)
480 (18.90)
8.2 (.32)
3–M4 POWER
TERMINAL
1
1357911 13 15246810 12 14 16
2
3
POWER UNIT*
CN1
1514 16
■CONNECTION DIAGRAM
1
2
FG
3
CN1 U(+)
V(−)
POWER
■CONNECTOR PIN ASSIGNMENT
Connector type: FCN 40-pin connector
(Fujitsu FCN-364P040-AU)
CN1: Output
PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
ch. 1 +
ch. 2 +
ch. 3 +
ch. 4 +
ch. 5 +
ch. 6 +
ch. 7 +
ch. 8 +
ch. 9 +
ch. 10 +
ch. 11 +
ch. 12 +
ch. 13 +
ch. 14 +
ch. 15 +
ch. 16 +
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
ch. 1 –
ch. 2 –
ch. 3 –
ch. 4 –
ch. 5 –
ch. 6 –
ch. 7 –
ch. 8 –
ch. 9 –
ch. 10 –
ch. 11 –
ch. 12 –
ch. 13 –
ch. 14 –
ch. 15 –
ch. 16 –
A17 – A20, B17 – B20: Unused
17BXE-U1
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2906-A Rev.2 P. 2 / 3
WIRING INSTRUCTIONS
■M4 Screw (power input, power unit)
Torque: 0.8 N∙m
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the power ter-
minals.
3) Installation & environment
MAINTENANCE
Model HDC4-x-R is available as spare part to replace the
AC power unit.
Power units’ standard life is expected for 10 years with
average ambient temperature 35°C (95°F) and 1.0A load.
Contact M-System for use in extremely different conditions.
■HOW TO REPLACE THE POWER UNIT
1) Prepare Power Unit (switching regulator) model HDC4-
x-R.
2) Turn off the power supply connected to the Power Unit.
3) Remove the wire binding and wiring connected to the ter-
minal 1 – 2 and 4 – 5.
4) Loosen and remove the mounting screws A(2 places).
5) Detach the Power Unit from the Rack.
6) Attach the new Power Unit to the Rack and tighten the
screws in reverse order as explained above. The tighten-
ing torque of the mounting screws Ais 0.8 N·m.
A : Mounting screws
1 : 24V DC (+)
2 : 24V DC (–)
3 : FG
4 : AC power (V)
5 : AC power (U)
12345
A A
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
17BXE-U1
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-2906-A Rev.2 P. 3 / 3