CONNECT 10 SOFTWARE
Connect 10 software versions have different menus, wordings, etc. so
there may be some variations to the instructions below.
SETUP 1:
SETUP 2:
1. In the Connect 10, go to Installation Setup & Enter your PIN.
2. In Setup, under Heater, go to Is a Genus Heater installed? Select No.
3. Under "Use Connect temperature sensing?" Select Yes.
4. In the Channels setup select the Channel that will control power to this
module. (Generally Channel 8).
1. In the Connect 10, go to Installation Setup & Enter your PIN.
2. In Setup, under Heater, go to Temperature Control.
3. Select Display and control (Genus and Connect Inbuilt), then click Next.
4. Under Choose primary heater type: select your primary heater.
5. Under Choose secondary heater type: select your secondary heater,
then click Next.
6. Click through the menu and make necessary changes, and name your
heater/s.
7. In the Channels setup select the Channel that will control power to this
module. (Generally Channel 8).
FINAL CHECKING
1. Auto Relay is plugged into the assigned output Channel set above.
(usually aux 8).
2. 2 core low-voltage cable is connected to 5 & 6 terminals in heat pump.
3. Loop connector in 5 & 6 Terminal is removed.
4. Heat pump is set to max temperature.
This work must be done by a qualified, experienced person.
IMPORTANT REMINDER