manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MagnaFuel
  6. •
  7. Water Pump
  8. •
  9. MagnaFuel Quick Star 300 Series User manual

MagnaFuel Quick Star 300 Series User manual

This manual suits for next models

2

Other MagnaFuel Water Pump manuals

MagnaFuel ProTuner MP-4301 User manual

MagnaFuel

MagnaFuel ProTuner MP-4301 User manual

MagnaFuel Outlaw Series User manual

MagnaFuel

MagnaFuel Outlaw Series User manual

MagnaFuel PRO STAR 500 Series User manual

MagnaFuel

MagnaFuel PRO STAR 500 Series User manual

Popular Water Pump manuals by other brands

Watershed Innovations HYDRAPUMP SMART FLEX Instructional manual

Watershed Innovations

Watershed Innovations HYDRAPUMP SMART FLEX Instructional manual

Graco Modu-Flo AL-5M instructions

Graco

Graco Modu-Flo AL-5M instructions

Messner MultiSystem MPF 3000 operating instructions

Messner

Messner MultiSystem MPF 3000 operating instructions

Xylem Bell & Gossett WEHT0311M Installation, operation and maintenance instructions

Xylem

Xylem Bell & Gossett WEHT0311M Installation, operation and maintenance instructions

WilTec 50739 Operation manual

WilTec

WilTec 50739 Operation manual

Franklin Electric Little Giant 555702 HRK-360S instruction sheet

Franklin Electric

Franklin Electric Little Giant 555702 HRK-360S instruction sheet

Ingersoll-Rand PD02P Series Operator's manual

Ingersoll-Rand

Ingersoll-Rand PD02P Series Operator's manual

VS ZJ Series Operating	 instruction

VS

VS ZJ Series Operating instruction

Flotec FPZS50RP owner's manual

Flotec

Flotec FPZS50RP owner's manual

SKF Lincoln FlowMaster II User and maintenance instructions

SKF

SKF Lincoln FlowMaster II User and maintenance instructions

Xylem Lowara LSB Series Installation, operation and maintenance instructions

Xylem

Xylem Lowara LSB Series Installation, operation and maintenance instructions

Water Duro Pumps DCJ500 Operating & installation instructions

Water

Water Duro Pumps DCJ500 Operating & installation instructions

Action P490 Operating instructions & parts manual

Action

Action P490 Operating instructions & parts manual

Flo King Permacore Reusable Carbon Bag Disassembly. & Cleaning Instructions

Flo King

Flo King Permacore Reusable Carbon Bag Disassembly. & Cleaning Instructions

ARO ARO PD15P-X Operator's manual

ARO

ARO ARO PD15P-X Operator's manual

Pumptec 112V Series Operating instructions and parts manual

Pumptec

Pumptec 112V Series Operating instructions and parts manual

Virax 262070 user manual

Virax

Virax 262070 user manual

Neptun NPHW 5500 operating instructions

Neptun

Neptun NPHW 5500 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

QUICK STAR 300 SERIES
Installation and Operating Instructions
Series Model MP-4601 & MP-4650
Introduction:
The accompanying MagnaFuel fuel pump part# MP-4601 or MP-4650 is designed
for vehicles NOT subject to emission controls. The QUICK STAR 300 series can
be run continuously for up to 1 ½ hours for limited street driving. The MP-4601
and MP-4650 are a precision assembly for maximum performance. The following
instruction should be followed carefully.
Description of Operation:
This pump, like all MagnaFuel pumps, is compatible with all racing gasolines and
alcohol fuels. Fuel additives are not recommended and may void the warranty.
The MP-4601 and MP-4650 have an external by-pass that is adjustable from 25 to
35 psi. They come preset at 25 psi. The QUICK STAR 300 Series has enough
flow capacity to support 950 HP on gasoline or 500 HP on alcohol. All
MagnaFuel pumps require a #8 return line and a #8 vent or rollover valve. Return
line and vent must be above the fuel level. The QUICK STAR 300 series pump is
designed to work with a dead-head style regulator, if a by-pass style regulator is
desired; the by-pass at the pump must be capped or plugged.
Installation:
We suggest installing the MP-4601 and MP-4650 fuel pumps like the plumbing
diagram on the back of this page. The QUICK STAR 300 pump can be mounted
in any position necessary. The pump does not need to be gravity feed and can be
mounted a few inches above the fuel level if necessary. The duel relay is
redundant system and is optional. A single relay or 30 amp fuse is adequate. We
suggest using our flow radiused fitting in all of our products to enhance and
maximize the application.
5015 Galley Rd Colorado Springs CO 80915 (719) 532-1897 (800) 321-7761 Fax (719) 532-1899
Black Wire
To Ground
MP-3008
#10 Bulkheak
MP-3007
#10AN x #10 Straight
Inlet Line
#10 Braided Line
No Sharp Bends
MP-3017
#8AN x #10 Straight
To Regulator
Adjustable By-Pass Valve
To set system pressure:
CW=Higher CWW=Lower
25-30 psi Typical
Black Wire to Ground
MP-4650
Fuel Cell
Clear Foam From
Suction Area
Vent to Atmosphere
#8 or 1/2"
By-Pass Return Line
#8 Braided Line
No Sharp Bends
NOTE: Fittings are not pipe thread. Using pipe fittings will cause damage.
Filter: We recommend the use of a filter with all fuel pumps.
Our Tech Line is (719) 532-1897
2 x #10 Red wires to Main Disconnect/Battery
2 x #18 Orange Wires to Powered Pump On/Off Switch
MP-4650 or MP-4601
Wiring/Plumbing Schematic
Blue Wires
To
Red Wires
MP-1050
Dual Relay Harness
s/N G-0000